Danby DPAC7099 User Manual

Owner’s Use and Care Guide
Guide de soin d’utiliser-et
Model • Modèle
DPAC 7099
PORTABLE AIR CONDITIONER
Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
CLIMATISEUR PORTATIF
Danby Products Ltd, PO Box 1778, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc, PO Box 669, Findlay, Ohio USA 45839-0669
Version 1.11.08 JF
CAUTION: Read and follow all safety rules and operating instructions before first use
of this product.
MISE EN GARDE : Veuillez lire attentivement les consignes de sécurité et les directives
d'utilisation avant l'utilisation initiale de ce produit.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE: If the unit changes
ownership, be sure this manual accompanies the unit.
CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE: En cas de revente du
l’unité, ce manuel doit être inclus avec l’appareil.
UNIT SPECIFICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
PART IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
IMPORTANT SAFETY INFORMATION
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Energy Saving Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Window Kit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
OPERATION
Features of the Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Draining Excess Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Air Conditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1
TABLE OF CONTENTS
Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.
Your Danby Portable Air-Conditioner is a multi-functional room air-exchanging, air-processing appliance, designed to offer you the functions of; Air Conditioning, Dehumidifying, and Independent Fan. Each individual mode is featured with “oscillating” air swing capabilities. This unit can be conveniently moved from room to room within your home and set up in just minutes. Imagine the convenience of 4 Season Home Comfort at your fingertips, anywhere, anytime.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on the rear panel of the unit.
Model Number:
Serial Number:
Date of Purchase:
This information will be necessary if your unit requires servicing and/or for
general inquiries. To contact a Customer Service Representative, call Danby
TOLL FREE: 1-800-26- (1-
800-263-2629)
2
Unit Specifications Model Number DPAC7099 Voltage/Frequency 115V-60Hz Noise Level 50 dB Fan Speeds 3 Airflow CFM High / Medium / Low 282 / 252 / 222 Cooling Capacity 7000BTU Refrigerant R410A Unit Weight 24.5 kg (53.9 lbs) Dimensions (inches) W x H x D 17
1
/3”x 12”x 27 1/6 Dimensions (mm) W x H x D 440 x 305 x 690 Remote Control Yes Time of Day Clock No Auto-Timer Yes
NOTE: Continuing research results in steady improvement. Therefore, this information and these specifications are subject to change without notice.
WELCOME
UNIT SPECIFICATIONS
READ ALL SAFETY INFORMATION BEFORE USING
1) Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2) This appliance draws 7.0 nameplate amps under Cooling Mode and may be used in any properly wired, general purpose 15 amp household grounded receptacle.
3) For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician.
WARNING: Improper connection of the
grounding plug can result in risk of Fire, Electric Shock, and/or injury to Persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is proplery grounded.
4) DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS WITH THIS UNIT. If it is necessary to use an extension cord with this unit, use an approved “air conditioner” extension cord only (available at most local hardware stores).
5) To avoid the possibility of personal injury, always disconnect the power supply to the unit before installing and/or servicing.
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
7.0 18 AWG- American Wire Gauge
*Based on copper wire at 105°C temperature rating.
TABLE 2
Receptacle and Fuse Types Rated Volts 125 Amps 15 Wall Outlet
Fuse Size 15 Time Delay Fuse Plug Type
(or Circuit Breaker)
3
Castors
On/Off Switch
Air Outlet
Handles
Air Outlet (Heat Exhaust)
Power Supply Cord
Water Outlet drain
Air Intake
(condenser)
Air Filter
Water outlet for continuous drain
Air Intake (Evaporator)
Air Filter
PART IDENTIFICATION
IMPORTANT SAFETY INFORMATION
ELECTRICAL
SPECIFICATIONS
CAUTION: Do not leave this
unit unattended in a space where people or animals cannot react to a failed unit are located. A failed unit can cause extreme overheating or death in such an enclosed, unattended space.
The power cord supplied with this air conditioner contains a device that senses damage to the power cord. To test if your power cord is working properly, you must do the following:
Your Danby appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater
efficiency.
1) Select a thermostat setting that suits your comfort needs and leave at that chosen setting.
2) The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times.
3) Use drapes, curtains or shades to keep direct sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow around the unit.
4) Start your air conditioner before the outdoor air becomes hot and uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room. Use of the automatic start/stop programmable TIMER feature can be a major asset in this regard if utilized to the fullest extent.
5) When outdoor temperatures are cool enough, turn the air conditioner off and use the FAN MODE. This circulates indoor air, providing some cooling comfort while utilizing less electricity.
NOTE: The power cord supplied with this air conditioner contains a current leakage detection device designed to reduce the risk of fire. In the event the power supply cord is damaged, it cannot be repaired and must be replaced with a new cord from the product manufacturer.
• Under no circumstances should this device be used to turn the unit on or off.
• The “RESET” button must always be pushed in (engaged) for correct operation.
• The power supply cord must be replaced if it fails to reset when the “TEST” button is pushed in.
1) Connect the power supply cord to an electrical outlet.
2) The power supply cord has two buttons located on the head of the plug. One button is marked “TEST”, and the other is marked “RESET”. Press the “TEST” button; you will hear a click as the “RESET” button pops out.
3) Press the “RESET” button; you will hear a click as the button engages.
4) The power supply cord is now energized and supplying electricity to the air conditioner (on some products this is also indicated by a light on the plug head).
4
IMPORTANT SAFETY INFORMATION
POWER SUPPLY
CORD
ENERGY-SAVING
TIPS
Air Conditioning Mode ONLY
Your window kit has been designed to fit most standard “vertical”/”horizontal” windows up to a maximum height of 80” (203cm). For vertical window applications, multi lock positions are provided on the edge of each slider section to secure each sliding section together.
1) Select a suitable location, making sure you have access to an electrical outlet.
2) Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the
exhaust opening and twist to lock into position.
3) Install the adjustable Window Slider Kit as required (see Fig. 3a & 3b).
4) Install the opposite end of the flexible exhaust hose into the window exhaust adapter.
5) Install the window exhaust adapter into the opening in the slider section, making sure the
window slider sections are secure.
6) Plug the unit into a 115V/60Hz grounded electrical outlet.
Window Slider Kit: Min.: 28
1
/3(67.5cm)
Max.: 80” (203cm)
Window Slider Kit: Min.: 28
1
/3(72cm)
Max.: 80” (203cm)
5
Horizontal Window
Vertical Window
There should be at least 11.8” (30cm) clearance between the unit and any other objects or building structures, and should be installed on a level surface. The unit does not have to be vented outside during Dehumidifying or Fan Only mode operation.
Flexible Exhaust Hose (13cm), Exhaust nozzle connector (Fix to unit)
(1pc).....................................................1/set
Adjustable window door slider kit (3 pcs)..... from
28 1/
3”(72cm) up to 80” (203cm)
Fixture..... (1 pcs)
Screws......(8 pcs)
NOTE: The exhaust/window kit must be installed
at all times when the unit is operating under AIR CONDITIONING mode.
ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.
Back of Window Pane
Tube Adapters
Fig. 2
Instructions for Assembling the Window Adapter Kit- Fig. 2
1) Insert tube adapters through the back of the
window panel.
2) Secure each tube adapter with four screws through the front of the window panel.
3) Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensions in place.
Fig. 3a
Fig. 3b
INSTALLATION
WINDOW
KIT
FIG 1. INSTALLATION ACCESSORIES
Fig. 1
6
LCD Display
Water Full Indicator
ON/OFF Switch
EMERGENCY ON/OFF Switch
• This switch is used when unit needs to be temporarily switched on/off.
• Pressing the emergency will turn on the unit. The running mode and fan speed mode will be set automatically.
• Pressing the emergency button again will stop the unit.
Note: When the unit is on, remember to lift up the air outlet flap.
WATER FULL INDICATOR
• When illuminated, signifies condensed water inside the unit can’t be discharged and the condensation water level has reached full water level.
• The unit stops operating when this indicator flashes. After discharging the water, press the POWER button to restart the unit. The operating mode will be that which was in operation before water full indicator illumination.
• LED light colour is RED
LCD DISPLAY
Cooling Mode Dehumidify Mode Fan only Mode
Auto Mode High Fan Speed
Medium Fan Speed
Low Fan Speed
Display set temperature
Display timer setting of auto switch
On/Off
Mode Control
The Mode Control has 4 settings:
• Cool • Dehumidify • Fan • Auto
The settings are adjusted by the Mode Control button
Fan Speed Control
The Fan Speed Control has 4 settings:
• Auto (Cool only) • High • Medium • Low
Temp. Set Controls
Press “ ” or “ ” to set temperature. The setting ranges from 16°C (61°F) to 32°C (89°F).
Note: When choosing Auto, Dehumidify or Fan Mode, temperature setting button is invalid.
OPERATION- Features of the Control Panel
Loading...
+ 16 hidden pages