Brocade Network Advisor User Manual

5 (1)

53-1003157-01

®

11 July 2014

Brocade Network Advisor

Installation and Migration Guide

Supporting Network Advisor 12.3.0

© 2014, Brocade Communications Systems, Inc. All Rights Reserved.

Brocade, the B-wing symbol, Brocade Assurance, ADX, AnyIO, DCX, Fabric OS, FastIron, HyperEdge, ICX, MLX, MyBrocade, NetIron, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and The Effortless Network and the On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and in other countries. Other brands and product names mentioned may be trademarks of others.

Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.

The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it.

The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.

Brocade Communications Systems, Incorporated

Corporate and Latin American Headquarters

Asia-Pacific Headquarters

 

Brocade Communications Systems, Inc.

Brocade Communications Systems China HK, Ltd.

130 Holger Way

No. 1 Guanghua Road

 

 

San Jose, CA 95134

Chao Yang District

 

 

Tel: 1-408-333-8000

Units 2718 and 2818

 

 

Fax: 1-408-333-8101

Beijing 100020, China

 

 

E-mail: info@brocade.com

Tel: +8610 6588 8888

 

 

 

Fax: +8610 6588 9999

 

 

 

E-mail: china-info@brocade.com

 

European Headquarters

Asia-Pacific Headquarters

 

Brocade Communications Switzerland Sàrl

Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)

Centre Swissair

Citic Plaza

 

 

Tour B - 4ème étage

No. 233 Tian He Road North

 

29, Route de l'Aéroport

Unit 1308 – 13th Floor

 

 

Case Postale 105

Guangzhou, China

 

 

CH-1215 Genève 15

Tel: +8620 3891 2000

 

 

Switzerland

Fax: +8620 3891 2111

 

 

Tel: +41 22 799 5640

E-mail: china-info@brocade.com

 

Fax: +41 22 799 5641

 

 

 

 

E-mail: emea-info@brocade.com

 

 

 

 

Document History

 

 

 

 

 

 

 

 

 

Title

 

Publication number

Summary of changes

Date

 

 

 

 

Brocade Network Advisor Installation and Migration Guide

53-1002570-01

New document

August 2012

 

 

 

 

Brocade Network Advisor Installation and Migration Guide

53-1002699-01

Update for 12.0

December 2012

 

 

 

 

Brocade Network Advisor Installation and Migration Guide

53-1002950-01

Update for 12.1

July 2013

 

 

 

 

Brocade Network Advisor Installation and Migration Guide

53-1003059-01

Update for 12.2.0

February 2014

 

 

 

 

Brocade Network Advisor Installation and Migration Guide

53-1003157-01

Update for 12.3.0

July 2014

 

 

 

 

 

Contents

About This Document

In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . viii Fabric OS hardware and software support . . . . . . . . . . . . . . . . viii IronWare OS hardware and software support . . . . . . . . . . . . . . . xi Network OS hardware and software support. . . . . . . . . . . . . . . xiv

What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Key terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi

Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii

Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii Brocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii Other industry resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii

Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix

Chapter 1

Installation

 

 

System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

 

Server and client operating system requirements . . . . . . . . . . .

2

 

Memory requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

 

Operating system cache requirements . . . . . . . . . . . . . . . . . . . .

5

 

Disk space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

 

Browser requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

 

Client and server system requirements . . . . . . . . . . . . . . . . . . . .

7

 

Downloading the software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Pre-installation requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Additional pre-installation requirements for UNIX systems. . . . . 9

Installing the application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Mapping the loopback address to the local host . . . . . . . . . . . 11

Headless installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Additional pre-installation requirements for UNIX systems (headless installation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Performing a headless installation on Windows

and UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Troubleshooting the Linux headless installation . . . . . . . . . . .13

Brocade Network Advisor Installation and Migration Guide

iii

53-1003157-01

 

Client-only installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Installing the client-only application . . . . . . . . . . . . . . . . . . . . . . 14

Chapter 2

Network Advisor Configuration

 

 

Configuring Network Advisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Accessing the Network Advisor interfaces . . . . . . . . . . . . . . . . . . . .22 Logging into a server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Launching a remote client. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Launching the SMC on Windows . . . . . . . . . . . . . . . . . . . . . . . . 24 Launching the SMC on Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Launching the SMIA Configuration Tool . . . . . . . . . . . . . . . . . . . 24 Launching the SMIA Configuration Tool remote client . . . . . . . 24

Syslog troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Finding the process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Stopping the process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Installing the ODBC driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Installing the ODBC driver on Windows systems . . . . . . . . . . . .26 Installing the ODBC driver on Linux systems . . . . . . . . . . . . . . . 27

Smart Card driver installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Installing the Smart Card driver on the local client . . . . . . . . . .30 Installing the Smart Card driver on the remote client . . . . . . . .32 Detecting and correcting a default Linux Smart Card driver. . .32

Configuring an explicit server IP address . . . . . . . . . . . . . . . . . . . . .34

Product improvement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Enabling product improvement data transfer . . . . . . . . . . . . . .35 Disabling product improvement data transfer . . . . . . . . . . . . . .36 Data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Configuring remote client access to the database . . . . . . . . . . . . . . 37

Chapter 3

Data Migration

 

 

Upgrading the license . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

39

Supported migration paths. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 DCFM migration paths. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 INM migration paths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 EFCM and Fabric Manager migration paths . . . . . . . . . . . . . . .44

Pre-migration requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 Pre-migration requirements when migrating from

one server to another . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 Additional pre-migration requirements on UNIX systems . . . . . 47 Additional trial requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Migrating data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Cross flavor migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 Migration rollback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54

iv

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

Chapter 4

Uninstallation

 

 

Uninstalling from Windows systems . . . . . . . . . . . . . . . . . . . . . . . . .

57

 

Uninstalling from Windows systems (headless uninstall) . . . . . . . .

58

 

Uninstalling from UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

58

 

Uninstalling from UNIX systems (headless uninstall) . . . . . . . . . . . .

59

Appendix A

References

 

 

Network Advisor packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61

 

Edition feature support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

62

 

Management server and client ports . . . . . . . . . . . . . . . . . . . . . . . .

72

 

Scalability limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

75

Brocade Network Advisor Installation and Migration Guide

v

53-1003157-01

 

vi

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

About This Document

In this chapter

How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

vii

Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

viii

What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xv

Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xvi

Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xvii

Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xvii

Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xviii

Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xix

How this document is organized

This document is organized to help you find the information that you want as quickly and easily as possible.

The document contains the following components:

Chapter 1, “Installation,” provides system and pre-installation requirements as well as step-by-step installation instructions.

Chapter 2, “Network Advisor Configuration,” provides step-by-step instructions to configure a fresh Network Advisor installation.

Chapter 3, “Data Migration,” provides pre-migration requirements as well as step-by-step instructions for migrating data from a previous release of Network Advisor.

Chapter 4, “Uninstallation,” provides step-by-step instructions for performing a partial or full uninstall of Network Advisor.

Appendix A, “References,” provides the following information for quick lookup:

-Network Advisor packages

-Edition feature support

-Management server and client ports

-Scalability limits

Brocade Network Advisor Installation and Migration Guide

vii

53-1003157-01

 

Supported hardware and software

In those instances in which procedures or parts of procedures documented here apply to some devices but not to others, this guide identifies exactly which devices are supported and which are not.

Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Network Advisor 12.3.X, documenting all possible configurations and scenarios is beyond the scope of this document.

Fabric OS hardware and software support

The following firmware platforms are supported by this release of Network Advisor 12.3.X:

Fabric OS 5.0 or later in a pure Fabric OS fabric

Fabric OS 6.0 or later in a mixed fabric

NOTE

Discovery of a Secure Fabric OS fabric in strict mode is not supported.

The hardware platforms in Table 1 are supported by this release of Network Advisor 12.3.X.

TABLE 1

Fabric OS-supported hardware

 

 

 

 

 

 

Device name

 

Terminology used in documentation

Firmware level required

 

 

 

Brocade 200E switch

16-port, 4 Gbps FC Switch

 

 

 

 

Brocade 300 switch

24-port, 8 Gbps FC Switch

Fabric OS v6.1.0 or later

 

 

 

Brocade 4012 switch

Embedded 12-port, 4 Gbps FC Switch

 

 

 

 

Brocade 4016 switch

Embedded 16-port, 4 Gbps FC Switch

 

 

 

 

Brocade 4018 switch

Embedded 18-port, 4 Gbps FC Switch

 

 

 

 

Brocade 4020 switch

Embedded 20-port, 4 Gbps FC Switch

 

 

 

 

Brocade 4024 switch

Embedded 24-port, 4 Gbps FC Switch

Fabric OS v5.3.1 or later

 

 

 

Brocade 4100 switch

32-port, 4 Gbps FC Switch

 

 

 

 

Brocade 4900 switch

64-port, 4 Gbps FC Switch

Fabric OS v5.2.0 or later

 

 

 

Brocade 5000 switch

32-port, 4 Gbps FC Interop Switch

Fabric OS v5.2.1 or later

 

 

 

Brocade 5100 switch

40-port, 8 Gbps FC Switch

Fabric OS v6.1.0 or later

 

 

 

Brocade 5300 switch

80-port, 8 Gbps FC Switch

Fabric OS v6.1.0 or later

 

 

 

Brocade 5410 embedded switch

Embedded 12-port, 8 Gbps Switch

Fabric OS v6.1.0 or later

 

 

 

Brocade 5424 embedded switch

Embedded 24-port, 8 Gbps Switch

Fabric OS v6.1.0 or later

 

 

 

Brocade 5431 embedded switch

Embedded 16-port, 8 Gbps Stackable Switch

Fabric OS v7.2.0 or later

 

 

 

Brocade 5450 embedded switch

Embedded 16-port, 8 Gbps Switch

Fabric OS v6.2.0 or later

 

 

 

Brocade 5460 embedded switch

Embedded 24-port, 8 Gbps Switch

Fabric OS v6.1.0_emb or later

 

 

 

Brocade 5470 embedded switch

Embedded 24-port, 8 Gbps Switch

Fabric OS v6.1.0 or later

 

 

 

Brocade 5480 embedded switch

Embedded 24-port, 8 Gbps Switch

Fabric OS v6.1.0 or later

 

 

 

Brocade 6505 switch

24-port, 16 Gbps Edge switch

Fabric OS v7.0.1 or later

viii

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

TABLE 1

Fabric OS-supported hardware (Continued)

 

 

 

 

 

Device name

 

Terminology used in documentation

Firmware level required

 

 

 

Brocade M6505 embedded switch

24-port, 16 Gbps embedded switch

Fabric OS v7.2.0 or later

 

 

 

Brocade 6510 switch

48-port, 16 Gbps switch

Fabric OS v7.0.0 or later

 

 

 

Brocade 6520 switch

96-port, 16 Gbps switch

Fabric OS v7.1.0 or later

 

 

 

Brocade 6547 embedded switch

48-port, 16 Gbps embedded switch

Fabric OS v7.2.0 or later

 

 

 

 

Brocade 7500 Extension switch

4

Gbps Router, Extension Switch

Fabric OS v5.1.0 or later

 

 

 

 

Brocade 7500E Extension switch

4

Gbps Extension Switch

Fabric OS v5.1.0 or later

 

 

 

 

FR4-18i Blade

4

Gbps Router, Extension blades

 

 

 

 

 

 

FX8-24 Blade

 

8

Gbps Router, Extension blades

Fabric OS v6.4.0 or later

 

 

 

 

Brocade AP7600 switch

4

Gbps 32-port Switch

Fabric OS v6.1.0 or later

 

 

 

 

Brocade 7800 switch

8

Gbps Extension Switch

Fabric OS v6.3.0 or later

 

 

 

Brocade 7840 switch

16 Gbps 24-FC port, 18 GbE port Switch

Fabric OS v7.3.0 or later

 

 

 

 

Brocade 8000 switch

8

Gbps 8-FC port, 10 GbE 24-DCB port Switch

Fabric OS v6.1.2_CEE

 

 

 

Brocade 8470 FCoE embedded switch

FCoE Embedded Switch

Fabric OS v6.3.1_CEE

 

 

 

 

Brocade VA-40FC switch

8

Gbps 40-port Switch

 

 

 

 

 

Brocade 415 Host Bus Adapter

4

Gbps 1-port HBA

 

 

 

 

 

Brocade 425 Host Bus Adapter

4

Gbps 2-port HBA

 

 

 

 

 

Brocade 815 Host Bus Adapter

8

Gbps 1-port HBA

 

 

 

 

 

Brocade 825 Host Bus Adapter

8

Gbps 2-port HBA

 

 

 

 

Brocade 1860 Fabric Adapter

16 Gbps FC HBA mode

Adapter Software 3.0.0.0 or later

 

 

10 Gbps CNA mode

 

 

 

10 Gbps NIC mode

 

 

 

 

Brocade 1867 HBA

16 Gbps Mezzanine HBA

Adapter Software 3.0.3.0 or later

 

 

 

Brocade 48000 director

Director Chassis

 

 

 

 

Brocade 48000 director with FC4-16, FC4-32,

Director Chassis with 4 Gbps 16-FC port, 4 Gbps

Fabric OS v5.2.0 or later (FC4-48)

and FC4-48 Blades

32-FC port, and 4 Gbps 48-FC port

 

 

 

 

Brocade 48000 director with FR4-18i Blades

Director Chassis with 4 Gbps router, extension

Fabric OS v5.1.0 or later (FR4-18i)

 

 

blades

 

Brocade 48000 director with FC4-16IP Blades

Director Chassis with 4 Gbps 8-FC port and 8

 

GbE iSCSI blades

Fabric OS v5.2.0 or later (FC4-16IP)

Brocade 48000 director with FC10-6 Blades

Director Chassis with 10 Gbps 6-port ISL blades

Fabric OS v5.3.0 or later (FC10-6)

 

 

 

Brocade DCX 1, 2

8-slot Backbone Chassis

Fabric OS v6.0.0 or later

Brocade DCX 1, 2 with FC8-16, FC8-32, and

8-slot Backbone Chassis with 8 Gbps 16-FC port,

Fabric OS v6.0.0 or later

FC8-48 Blades

8 Gbps 32-FC port, and 8 Gbps 48-FC port

 

 

blades

 

 

 

 

Brocade DCX 1, 2 with FC8-64 Blades

8-slot Backbone Chassis with 8 Gbps 64-FC port

Fabric OS v6.4.0

 

blades

 

 

 

 

Brocade DCX 1, 2 with FR4-18i Blades

8-slot Backbone Chassis with 4 Gbps Router,

Fabric OS v6.0.0 or later

 

Extension blade

 

 

 

 

Brocade DCX 1, 2 with FC10-6 Blades

8-slot Backbone Chassis with FC 10 - 6 ISL Blade

Fabric OS v6.2.0

Brocade Network Advisor Installation and Migration Guide

ix

53-1003157-01

 

TABLE 1

Fabric OS-supported hardware (Continued)

 

 

 

 

 

Device name

 

Terminology used in documentation

Firmware level required

 

 

 

Brocade DCX 1, 2 with FS8-18 Blades

8-slot Backbone Chassis with Encryption Blade

Fabric OS v6.1.1_enc or later

Brocade DCX 1, 2 with FX8-24 Blades

8-slot Backbone Chassis with 8 Gbps 12-FC port,

Fabric OS v6.3.1_CEE

 

 

10 GbE ports, 2-10 GbE ports blade

 

 

 

 

Brocade DCX-4S with FC16-64 Blades

4-slot Backbone Chassis with 16 Gbps 64-FC

Fabric OS v7.3.0 or later

 

 

port blades

 

 

 

 

Brocade DCX 1, 2 with FCoE10-24 Blades

8-slot Backbone Chassis with 10 Gbps 24-port

Fabric OS v6.3.1_CEE

 

 

FCoE blade

 

 

 

 

Brocade DCX-4S

4-slot Backbone Chassis

Fabric OS v6.0.0 or later

 

 

 

Brocade DCX-4S with FC8-16, FC8-32, and

4-slot Backbone Chassis with 8 Gbps 16-FC port,

Fabric OS v6.2.0

FC8-48 Blades

8 Gbps 32-FC port, and 8 Gbps 48-FC port

 

 

 

blades

 

 

 

 

Brocade DCX-4S with FC8-64 Blades

4-slot Backbone Chassis with 8 Gbps 64-FC port

Fabric OS v6.4.0

 

 

blades

 

 

 

 

Brocade DCX-4S with FR4-18i Blades

4-slot Backbone Chassis with 4 Gbps Router,

Fabric OS v6.2.0

 

 

Extension blade

 

 

 

 

Brocade DCX-4S with FC10-6 Blades

4-slot Backbone Chassis with FC 10 - 6 ISL Blade

Fabric OS v6.2.0

 

 

 

Brocade DCX-4S with FS8-18 Blades

4-slot Backbone Chassis with Encryption Blade

Fabric OS v6.1.1_enc or later

 

 

 

Brocade DCX-4S with FX8-24 Blades

4-slot Backbone Chassis with 8 Gbps 12-FC port,

Fabric OS v6.3.1_CEE

 

 

10 GbE ports, 2-10 GbE ports blade

 

 

 

 

Brocade DCX-4S with FCoE10-24 Blades

4-slot Backbone Chassis with 10 Gbps 24-port

Fabric OS v6.3.0 or later

 

 

FCoE blade

 

 

 

 

Brocade DCX 8510-4

16 Gbps 4-slot Backbone Chassis

Fabric OS v7.0.0 or later

 

 

 

Brocade DCX 8510-81, 2

16 Gbps 8-slot Backbone Chassis

Fabric OS v7.0.0 or later

Brocade Encryption Switch

8 Gbps Encryption Switch

Fabric OS v6.1.1_enc or later

 

 

 

FS8-18 Encryption Blade

Encryption Blade

 

 

 

 

FA4-18 Application Platform Blade

Application Platform Blade

 

 

 

 

 

FC8-16 Blade

 

FC 8 GB 16-port Blade

 

 

 

 

 

FC8-32 Blade

 

FC 8 GB 32-port Blade

 

 

 

 

 

FC8-48 Blade

 

FC 8 GB 48-port Blade

 

 

 

 

 

FC8-64 Blade

 

FC 8 GB 64-port Blade

 

 

 

 

 

FC10-6 Blade

 

FC 10 - 6 ISL Blade

 

 

 

 

FC8-32E blade3

8 Gbps 32-port blade

Fabric OS v7.0.1 or later

FC8-48E blade3

8 Gbps 48-port blade

Fabric OS v7.0.1 or later

FC16-32 Blade

16 Gbps 32-port blade

Fabric OS v7.0.0 or later

 

 

 

FC16-48 Blade

16 Gbps 48-port blade

Fabric OS v7.0.0 or later

 

 

 

FC16-64 Blade

16 Gbps 64-port blade

Fabric OS v7.3.0 or later

 

 

 

FCoE10-24 Blade

10 Gbps FCoE Port Router Blade

 

x

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

TABLE 1

Fabric OS-supported hardware (Continued)

 

 

 

 

 

Device name

 

Terminology used in documentation

Firmware level required

 

 

 

FX8-24 Blade 1, 2

8 Gbps Extension Blade

 

1Professional can discover, but not manage this device. Use the device’s Element Manager, which can be launched from the Connectivity Map, to manage the device. This device cannot be used as a Seed switch.

2Professional Plus Trial and Licensed version can discover, but not manage, this device. Use the device’s Element Manager, which can be launched from the Connectivity Map, to manage the device. This device cannot be used as a Seed switch.

3Only supported on the DCX 8510-4 and DCX 8510-8 chassis.

IronWare OS hardware and software support

The following firmware platforms are supported by this release of Network Advisor 12.3.X:

BigIron 2.7.02e (sustaining mode) or later

FastIron 7.2.0 or later

NetIron 5.1.0 or later

ServerIron (JetCore) 11.0 or later

ServerIron ADX 12.2.0 or later

TurboIron 4.2.0 or later

For platform-specific firmware requirements, refer to Table 2.

Table 2 lists the hardware platforms supported by this release of Network Advisor 12.3.X, the terminology used in the documentation, as well as any specific firmware requirements.

TABLE 2

IronWare OS-supported hardware

 

 

 

 

 

 

Device name

 

Terminology used in documentation

Firmware level required

 

 

 

 

BigIron family

 

Ethernet Chassis

BigIron 2.7.02e or 2.7.01b

 

 

 

BigIron RX-4 (BI-RX-4-AC)

Ethernet Chassis, 4 interface slots

BigIron 2.7.02e or 2.7.01b

 

 

 

BigIron RX-8 (BI-RX-8-AC)

Ethernet Chassis, 8 interface slots

BigIron 2.7.02e or 2.7.01b

 

 

 

BigIron RX-16 (BI-RX-16-AC-A)

Ethernet Chassis, 16 interface slots

BigIron 2.7.02e or 2.7.01b

 

 

 

Brocade 6910 Ethernet Access Switch

Ethernet Access Switch

release 2.0.2.7, loader version 1.0.1.3

 

 

 

FastIron family

Ethernet switch

See individual device.

 

 

 

FastIron CX 624S (FCX624S)

Ethernet L2/L3 Edge switch, 24 1GbE

FastIron 06.0.00 and later

 

 

RJ45 ports

 

 

 

 

FastIron CX 648S (FCX648S)

Ethernet L2/L3 Edge switch, 48 1GbE

FastIron 06.0.00 and later

 

 

RJ45 ports

 

 

 

 

FastIron CX 624S-HPOE (FCX624S-HPOE)

Ethernet L2/L3 Edge switch, 24 1GbE

FastIron 06.0.00 and later

 

 

RJ45 ports, 24 POE+ ports

 

 

 

 

FastIron CX 648S-HPOE (FCX648S-HPOE)

Ethernet L2/L3 Edge switch, 48 1GbE

FastIron 06.0.00 and later

 

 

RJ45 ports, 48 POE+ ports

 

 

 

 

FastIron CX 624S-F (FCX624S-F)

Ethernet L2/L3 Edge switch, 20 SFP ports

FastIron 06.0.00 and later

 

 

 

FastIron CX 624-E (FCX624-E)

Ethernet L2/L3 Edge switch, 24 1GbE

FastIron 06.0.00 and later

 

 

RJ45 ports

 

Brocade Network Advisor Installation and Migration Guide

xi

53-1003157-01

 

TABLE 2 IronWare OS-supported hardware (Continued)

Device name

Terminology used in documentation

Firmware level required

 

 

 

FastIron CX 624-I (FCX624-I)

Ethernet L2/L3 Edge switch, 24 1GbE

FastIron 06.0.00 and later

 

RJ45 ports

 

 

 

 

FastIron CX 648-E (FCX648-E)

Ethernet L2/L3 Edge switch, 48 1GbE

FastIron 06.0.00 and later

 

RJ45 ports

 

 

 

 

FastIron CX 648-I (FCX648-I)

Ethernet L2/L3 Edge switch, 48 1GbE

FastIron 06.0.00 and later

 

RJ45 ports

 

 

 

 

ICX 6610

Ethernet L2/L3 Edge switch

FastIron 07.0.3 and later

 

 

 

ICX 643024 switch

24-port Campus LAN switch

FastIron 07.4.00 and later

 

 

 

ICX 643024-HPOE switch

24-port Campus LAN HPOE switch

FastIron 07.4.00 and later

 

 

 

ICX 643048 switch

48-port Campus LAN switch

FastIron 07.4.00 and later

 

 

 

ICX 643048-HPOE switch

48-port Campus LAN HPOE switch

FastIron 07.4.00 and later

 

 

 

ICX 645024 switch

24-port Campus LAN switch

FastIron 07.4.00 and later

 

 

 

ICX 645024 Base L3 router

24-port Campus LAN Base L3 router

FastIron 07.4.00 and later

 

 

 

ICX 645024 Base router

24-port Campus LAN Base router

FastIron 07.4.00 and later

 

 

 

ICX 645024 Premium router

24-port Campus LAN Premium router

FastIron 07.4.00 and later

 

 

 

ICX 645024-HPOE switch

24-port Campus LAN HPOE switch

FastIron 07.4.00 and later

 

 

 

ICX 645024-HPOE Base L3 router

24-port Campus LAN HPOE Base L3 router

FastIron 07.4.00 and later

 

 

 

ICX 645024-HPOE Base router

24-port Campus LAN HPOE Base router

FastIron 07.4.00 and later

 

 

 

ICX 645024-HPOE Premium router

24-port Campus LAN HPOE Premium

FastIron 07.4.00 and later

 

router

 

 

 

 

ICX 645048 switch

48-port Campus LAN switch

FastIron 07.4.00 and later

 

 

 

ICX 645048 Base L3 router

48-port Campus LAN Base L3 router

FastIron 07.4.00 and later

 

 

 

ICX 645048 Base router

48-port Campus LAN Base router

FastIron 07.4.00 and later

 

 

 

ICX 645048 Premium router

48-port Campus LAN Premium router

FastIron 07.4.00 and later

 

 

 

ICX 645048-HPOE switch

48-port Campus LAN HPOE switch

FastIron 07.4.00 and later

 

 

 

ICX 645048-HPOE Base L3 router

48-port Campus LAN HPOE Base L3 router

FastIron 07.4.00 and later

 

 

 

ICX 645048-HPOE Base router

48-port Campus LAN HPOE Base router

FastIron 07.4.00 and later

 

 

 

ICX 645048-HPOE Premium router

48-port Campus LAN HPOE Premium

FastIron 07.4.00 and later

 

router

 

 

 

 

ICX 6430 IronStack switch

24-port Campus LAN switch

FastIron 07.4.00 and later

 

 

 

ICX 6430 IronStack Base L3 router

Campus LAN Base L3 router

FastIron 07.4.00 and later

 

 

 

ICX 6430 IronStack Base router

Campus LAN Base router

FastIron 07.4.00 and later

 

 

 

ICX 6430 IronStack Premium router

Campus LAN Premium router

FastIron 07.4.00 and later

 

 

 

ICX 6450 IronStack switch

48-port Campus LAN switch

FastIron 07.4.00 and later

 

 

 

ICX 7750-26Q switch

26 10/40 GbE QSFP+ ports

FastIron 08.0.10 and later

 

 

 

ICX 7750-48F switch

48 1/10 GbE SFP+ ports and six 10/40

FastIron 08.0.10 and later

 

GbE QSFP+ ports

 

xii

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

TABLE 2 IronWare OS-supported hardware (Continued)

Device name

Terminology used in documentation

Firmware level required

 

 

 

ICX 7750-48C switch

48 1/10 GbE RJ-45 ports and six 10/40

FastIron 08.0.10 and later

 

GbE QSFP+ ports

 

 

 

 

FastIron GS

Ethernet L2/L3 Access switch

 

 

 

 

FastIron GS-STK

Ethernet L2/L3 Access switch, stackable

 

 

 

 

FastIron LS

Enterprise LAN switch

 

 

 

 

FastIron LS-STK

Enterprise LAN switch, stackable

 

 

 

 

FastIron SuperX/SX

Enterprise LAN chassis

FSX 02.4.00 and later

 

 

 

FastIron SX 800 and FastIron SX 1600

Enterprise LAN chassis

FSX 02.4.00 and later

 

 

 

FastIron 8-port 10 GbE SFP Blade

8-port 10 GbE SFP Blade

 

 

 

 

FastIron 24-port Fiber SFP GbE Blade

24-port Fiber SFP GbE Blade

 

 

 

 

FastIron 24-port GbE Cu Blade

24-port GbE Cu Blade

 

 

 

 

FastIron 2-port 10GbE SFP+ Blade

2-port 10GbE SFP+ Blade

 

 

 

 

FastIron Edge Switch X-Series

Enterprise LAN Edge switch

 

 

 

 

FastIron Edge X 424

Enterprise LAN Edge switch, 24

 

 

10/100/1000 Mbps ports

 

 

 

 

FastIron Edge X 624

Enterprise LAN Edge switch, 24

 

 

10/100/1000 Mbps ports

 

 

 

 

FastIron Edge X 448

Enterprise LAN Edge switch, 48

 

 

10/100/1000 Mbps ports

 

 

 

 

FastIron Edge X 648

Enterprise LAN Edge switch, 48

 

 

10/100/1000 Mbps ports

 

 

 

 

FastIron Edge X 424HF

Enterprise LAN Edge switch, 20 100/1000

 

 

Mbps SFP ports

 

 

 

 

FastIron Edge X 624HF

Enterprise LAN Edge switch, 20 100/1000

 

 

Mbps SFP ports

 

 

 

 

FastIron WS devices

Enterprise Campus switch

 

 

 

 

Motorola Controllers RFS4000 series

Wireless controller

Mobility 5.1

 

 

 

Motorola Controllers RFS6000 series

Wireless controller

Mobility 5.1

 

 

 

Motorola Controllers RFS7000 series

Wireless controller

Mobility 5.1

 

 

 

Motorola Access Point 7131

Wireless access point

Mobility 4.1.1 (standalone mode)

 

 

Mobility 5.1 1 (adaptive mode)

Motorola Access Point 7131N

Wireless access point

Mobility 4.1.1 (standalone mode)

 

 

Mobility 5.1 1 (adaptive mode)

Motorola Access Point 5181

Wireless access point

Mobility 2.5.X (standalone mode)

 

 

Mobility 5.1 1 (adaptive mode)

Motorola Access Point 6511

Wireless access point

Mobility 5.1 1 (adaptive mode)

NetIron family

Ethernet routers

NetIron 5.0.0 or 5.0.1

 

 

 

NetIron MLX

Ethernet router

NetIron 5.0.0 or 5.0.1

(Supported regardless of license

 

 

configuration)

 

 

Brocade Network Advisor Installation and Migration Guide

xiii

53-1003157-01

 

TABLE 2 IronWare OS-supported hardware (Continued)

Device name

Terminology used in documentation

Firmware level required

 

 

 

NetIron MLXe

Ethernet Core router

NetIron 5.0.0 or 5.0.1

(Supported regardless of license

 

 

configuration)

 

 

 

 

 

NetIron XMR

Ethernet Backbone router

NetIron 5.0.0 or 5.0.1

(Supported regardless of license

 

 

configuration)

 

 

 

 

 

NetIron CES 2048CX (NI-CES-2048CX-AC)

Ethernet Carrier router

NetIron 5.0.0 or 5.0.1

(Supported regardless of license

 

 

configuration)

 

 

 

 

 

NetIron CER

Ethernet Edge router

NetIron 5.0.0 or 5.0.1

(Supported regardless of license

 

 

configuration)

 

 

 

 

 

NetIron XMR/MLX 2-Port 100Gbe Module

2-Port 100Gbe Module

NetIron 5.7.0

 

 

 

NetIron XMR/MLX 20-port 10GbE Module

20-port 10GbE Module

NetIron 5.7.0

 

 

 

ServerIron family

Application product

 

 

 

 

ServerIron ADX 1000

Application switch

 

 

 

 

ServerIron ADX 1000F

Application Fiber switch

ADX 12.3.03 or later

 

 

 

ServerIron ADX 4000

4U Application Delivery chassis

ADX 12.1.00 or later

 

 

 

ServerIron ADX 10000

10U Application Delivery chassis

ADX 12.1.00 or later

 

 

 

TurboIron Family

Data Center switch

4.1.00d or 4.2.00 or later

 

 

 

TurboIron 24X (T1-24X-AC)

Data Center switch

4.1.00d or 4.2.00 or later

 

 

 

Brocade 6650 Switch

Data Center switch

FastIron 7.5 and later

 

 

 

Brocade 6650 Base L3 Router

Data Center base L3 router

FastIron 7.5 and later

 

 

 

Brocade 6650 Router

Data Center router

FastIron 7.5 and later

 

 

 

1 The Management application cannot discover or manage wireless access points running Mobility 5.1.

Network OS hardware and software support

Network Advisor 12.3.X supports the Network OS 2.1 or later firmware platform. For platform-specific firmware requirements, if any, refer to the Table 3.

Table 3 lists the hardware platforms supported by this release of Network Advisor 12.3.X, the terminology used in the documentation, as well as any specific firmware requirements.

TABLE 3

Network OS-supported hardware

 

 

 

 

 

 

Device name

 

Terminology used in documentation

Firmware level required

 

 

 

Brocade VDX 2730 10 Gbps connection blade

VDX 2730 10 Gbps connection blade

2.1.1_fuj

 

 

 

Brocade VDX 2740 switch

VDX 2740 switch

4.0.0_bbd

 

 

 

Brocade VDX 6710 switch

VDX 6710 switch

2.1 or later

 

 

 

Brocade VDX 6720-24 switch

VDX 6720-24 switch

2.1 or later

 

 

 

Brocade VDX 6720-60 switch

VDX 6720-60 switch

2.1 or later

xiv

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

TABLE 3

Network OS-supported hardware (Continued)

 

 

 

 

 

Device name

 

Terminology used in documentation

Firmware level required

 

 

 

Brocade VDX 6730-32 switch

VDX 6730-32 switch

2.1 or later

 

 

 

Brocade VDX 6730-76 switch

VDX 6730-76 switch

2.1 or later

 

 

 

Brocade VDX 6740 switch

VDX 6740 switch

4.0 or later

 

 

 

Brocade VDX 6740T switch

VDX 6740T switch

4.0 or later

 

 

 

Brocade VDX 6740T-1G switch

VDX 6740T-1G switch

4.1 or later

 

 

 

Brocade VDX 8770-4 switch

VDX 8770-4 switch

3.0 or later

 

 

 

Brocade VDX 8770-8 switch

VDX 8770-8 switch

3.0 or later

 

 

 

Brocade VDX 8770 with 40G/10G Base-T by line card

VDX 8770 switch with 40G/10G Base-T by line card

4.1 or later

 

 

 

 

What’s new in this document

The following changes have been made since this document was last released:

Information that was added:

-Migration rollback

Information that was changed:

-Supported hardware and software

-Server and Client operating system requirements

-Client only installation

-Supported migration paths

Information that was deleted:

-None.

For further information about new features and documentation updates for this release, refer to the release notes.

Brocade Network Advisor Installation and Migration Guide

xv

53-1003157-01

 

Document conventions

This section describes text formatting conventions and important notice formats used in this document.

Text formatting

The narrative-text formatting conventions that are used are as follows:

bold text

Identifies command names

 

Identifies the names of user-manipulated GUI elements

 

Identifies keywords and operands

 

Identifies text to enter at the GUI or CLI

italic text

Provides emphasis

 

Identifies variables

 

Identifies paths and Internet addresses

 

Identifies document titles

code text

Identifies CLI output

 

Identifies command syntax examples

For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is all lowercase.

Notes

The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.

NOTE

A note provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information.

Key terms

For definitions specific to Brocade and Fibre Channel, see the technical glossaries on MyBrocade. See “Brocade resources” on page xvii for instructions on accessing MyBrocade.

For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at:

http://www.snia.org/education/dictionary

xvi

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

Notice to the reader

This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations.

These references are made for informational purposes only.

Corporation

Referenced trademarks and products

 

 

Linus Torvalds

Linux

 

 

Microsoft Corporation

Windows, Windows NT, Internet Explorer

 

 

Netscape Communications Corporation

Netscape

 

 

Red Hat, Inc.

Red Hat, Red Hat Network, Maximum RPM, Linux Undercover

 

 

Oracle

Sun, Solaris, Sun Fire, Sun Ultra, Java Plug-in

 

 

The Open Group

UNIX

 

 

VMware, Inc.

VMware

 

 

Additional information

This section lists additional Brocade and industry-specific documentation that you might find helpful.

Brocade resources

To get up-to-the-minute information, go to http://my.brocade.com to register at no cost for a user ID and password.

White papers, online demonstrations, and data sheets are available through the Brocade website at:

http://www.brocade.com/products-solutions/products/index.page

For additional Brocade documentation, visit the Brocade website: http://www.brocade.com

Release notes are available on the MyBrocade website.

Other industry resources

For additional resource information, visit the Technical Committee T11 website. This website provides interface standards for high-performance and mass storage applications for Fibre Channel, storage management, and other applications:

http://www.t11.org

For information about the Fibre Channel industry, visit the Fibre Channel Industry Association website:

http://www.fibrechannel.org

Brocade Network Advisor Installation and Migration Guide

xvii

53-1003157-01

 

Getting technical help

Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available:

1.Management Application Serial Number

To obtain the Management application serial number, select Help > License. The License dialog box displays.

2.General Information

Switch model

Switch operating system version

Software name and software version, if applicable

Error numbers and messages received

supportSave command output

Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions

Description of any troubleshooting steps already performed and the results

Serial console and Telnet session logs

syslog message logs

3.Switch Serial Number

The switch serial number and corresponding bar code are provided on the serial number label, as illustrated below:

FT00X0054E9

The serial number label is located as follows:

Brocade 300, 4100, 4900, 5100, 5300, 7500, 7800, 8000, VA-40FC, and Brocade Encryption Switch—On the switch ID pull-out tab located inside the chassis on the port side on the left

Brocade 5000—On the switch ID pull-out tab located on the bottom of the port side of the switch

Brocade 7600—On the bottom of the chassis

Brocade 48000—Inside the chassis next to the power supply bays

Brocade DCX—On the bottom right on the port side of the chassis

Brocade DCX-4S—On the bottom right on the port side of the chassis, directly above the cable management comb

xviii

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

4.World Wide Name (WWN)

Use the licenseIdShow command to display the WWN of the chassis.

If you cannot use the licenseIdShow command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis.

Document feedback

Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to:

documentation@brocade.com

Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.

Brocade Network Advisor Installation and Migration Guide

xix

53-1003157-01

 

xx

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

 

Chapter

Installation

1

 

 

 

 

In this chapter

System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Downloading the software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Pre-installation requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Installing the application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Headless installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Client-only installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

System requirements

Use the following sections to determine if you have met the requirements for this application:

Server and client operating system requirements . . . . . . . . . . . . . . . . . . . . . 2

Memory requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Operating system cache requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Disk space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Browser requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Client and server system requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Brocade Network Advisor Installation and Migration Guide

1

53-1003157-01

 

1 System requirements

Server and client operating system requirements

Table 4 summarizes the required operating system (OS) for servers and the packages supported by each OS version.

NOTE

Enterprise edition (SAN or IP) and Professional Plus edition (SAN or IP) are not supported on 32-bit operating systems. You must migrate to a 64-bit operating system.

NOTE

SAN with SMI Agent + IP edition is not supported on 32-bit operating systems.

TABLE 4

 

Server operating system requirements

 

 

 

 

 

 

 

 

Operating

Version

 

 

Guest OS version

Supported packages

system

 

 

 

 

 

 

 

 

 

 

 

 

Windows®

-

2008

Server (x86 32-bit)

 

SAN with SMI Agent

 

-

7 Enterprise (x86 32-bit)

 

IP only

 

-

2008

Server (x86 64-bit)

 

SMI Agent only

 

-

7 Enterprise (x86 64-bit)

 

 

 

-

2008

R2

Data Center Edition (x86 32-bit)

 

SAN with SMI Agent

 

-

2008

R2

Standard Edition (x86 32-bit)

 

IP only

 

-

2008

R2

Enterprise Edition (x86 32-bit)

 

SMI Agent only

 

-

2012 R2 Data Center Edition (x86 32-bit)

 

SAN with SMI Agent + IP

 

-

2012 R2 Standard Edition (x86 32-bit)

 

 

 

-

7 Enterprise (x86 32-bit)

 

 

 

-

8 Enterprise (x86 32-bit)

 

 

 

-

8.1 Enterprise (x86 32-bit)

 

 

 

-

2008

R2

Data Center Edition (x86 64-bit)

 

SAN with SMI Agent

 

-

2008

R2

Standard Edition (x86 64-bit)

 

IP only

 

-

2008

R2

Enterprise Edition (x86 64-bit)

 

SMI Agent only

 

-

2012 R2 Data Center Edition (x86 64-bit)

 

SAN with SMI Agent + IP

 

-

2012 R2 Standard Edition (x86 64-bit)

 

 

 

-

7 Enterprise (x86 64-bit)

 

 

 

-

8 Enterprise (x86 64-bit)

 

 

 

-

8.1 Enterprise (x86 64-bit)

 

 

2

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

System requirements

1

TABLE 4

 

Server operating system requirements (Continued)

 

 

 

 

 

 

Operating

Version

Guest OS version

Supported packages

system

 

 

 

 

 

 

 

 

 

Linux®

-

RedHat Enterprise 6.1 Advanced (x86 32-bit)

 

SAN with SMI Agent

 

-

RedHat Enterprise 6.2 Advanced (x86 32-bit)

 

IP only

 

-

RedHat Enterprise 6.3 Advanced (x86 32-bit)

 

SMI Agent only

 

-

RedHat Enterprise 6.4 Advanced (x86 32-bit)

 

 

 

-

RedHat Enterprise 6.5 Advanced (x86 32-bit)

 

 

 

-

SuSE Enterprise Server 11 (x86 32-bit)

 

 

 

-

SuSE Enterprise Server 11.3 (x86 32-bit)

 

 

 

-

Oracle Enterprise 6.1 (x86 32-bit)

 

 

 

-

Oracle Enterprise 6.2 (x86 32-bit)

 

 

 

-

Oracle Enterprise 6.3 (x86 32-bit)

 

 

 

-

Oracle Enterprise 6.4 (x86 32-bit)

 

 

 

-

Oracle Enterprise 6.5 (x86 32-bit)

 

 

 

-

RedHat Enterprise 6.1 Advanced (x86 64-bit)

 

SAN with SMI Agent

 

-

RedHat Enterprise 6.2 Advanced (x86 64-bit)

 

IP only

 

-

RedHat Enterprise 6.3 Advanced (x86 64-bit)

 

SMI Agent only

 

-

RedHat Enterprise 6.4 Advanced (x86 64-bit)

 

SAN with SMI Agent + IP

 

-

RedHat Enterprise 6.5 Advanced (x86 64-bit)

 

 

 

-

SuSE Enterprise Server 11.3 (x86 64-bit)

 

 

 

-

Oracle Enterprise 6.1 (x86 64-bit)

 

 

 

-

Oracle Enterprise 6.2 (x86 64-bit)

 

 

 

-

Oracle Enterprise 6.3 (x86 64-bit)

 

 

 

-

Oracle Enterprise 6.4 (x86 64-bit)

 

 

 

-

Oracle Enterprise 6.5 (x86 64-bit)

 

 

Guest VMs

-

VMware® ESX Server i 5.11

Supports all server

Supports all packages

 

-

VMware ESX Server i 5.5

OS versions

available for Windows

 

-

Microsoft Hyper-V (Hyper-V Server 2008 R2 SP1)

available for

and Linux.

 

-

KVM RH 6.5

Windows and

 

 

 

 

Linux.

 

1.It is recommended that you run all Network Advisor virtual CPUs on a single physical CPU.

Brocade Network Advisor Installation and Migration Guide

3

53-1003157-01

 

TABLE 5

1 System requirements

Table 5 summarizes the required OS for clients.

Client operating system requirements

Operating

Version

Guest OS version

system

 

 

-2008 Server (x86 32-bit)

®- 7 Enterprise (x86 32-bit)

-2008 Server (x86 64-bit)

-7 Enterprise (x86 64-bit)

-2008 R2 Data Center Edition (x86 32-bit)

-2008 R2 Standard Edition (x86 32-bit)

-2008 R2 Enterprise Edition (x86 32-bit)

-2012 R2 Data Center Edition (x86 32-bit)

-2012 R2 Standard Edition (x86 32-bit)

-7 Enterprise (x86 32-bit)

-8 Enterprise (x86 32-bit)

-8.1 Enterprise (x86 32-bit)

-2008 R2 Data Center Edition (x86 64-bit)

-2008 R2 Standard Edition (x86 64-bit)

-2008 R2 Enterprise Edition (x86 64-bit)

-2012 R2 Data Center Edition (x86 64-bit)

-2012 R2 Standard Edition (x86 64-bit)

-7 Enterprise (x86 64-bit)

-8 Enterprise (x86 64-bit)

-8.1 Enterprise (x86 64-bit)Windows

 

 

 

 

Linux®

-

RedHat Enterprise 6.1 Advanced (x86 32-bit)

 

 

- RedHat Enterprise 6.2 Advanced (x86 32-bit)

 

 

-

RedHat Enterprise 6.3 Advanced (x86 32-bit)

 

 

-

RedHat Enterprise 6.4 Advanced (x86 32-bit)

 

 

-

RedHat Enterprise 6.5 Advanced (x86 32-bit)

 

 

-

SuSE Enterprise Server 11 (x86 32-bit)

 

 

-

SuSE Enterprise Server 11.3 (x86 32-bit

 

 

-

Oracle Enterprise 6.1 (x86 32-bit)

 

 

-

Oracle Enterprise 6.2 (x86 32-bit)

 

 

-

Oracle Enterprise 6.3 (x86 32-bit)

 

 

-

Oracle Enterprise 6.4 (x86 32-bit)

 

 

-

Oracle Enterprise 6.5 (x86 64-bit)

 

 

- RedHat Enterprise 6.1 Advanced (x86 64-bit)

 

 

-

RedHat Enterprise 6.2 Advanced (x86 64-bit)

 

 

-

RedHat Enterprise 6.3 Advanced (x86 64-bit)

 

 

-

RedHat Enterprise 6.4 Advanced (x86 64-bit)

 

 

-

RedHat Enterprise 6.5 Advanced (x86 64-bit)

 

 

-

Oracle Enterprise 6.1 (x86 64-bit)

 

 

-

Oracle Enterprise 6.2 (x86 64-bit)

 

 

-

Oracle Enterprise 6.3 (x86 64-bit)

 

 

-

Oracle Enterprise 6.4 (x86 64-bit)

 

 

-

Oracle Enterprise 6.5 (x86 64-bit)

 

Guest

-

VMware® ESX Server i 5.1

Supports all client OS versions available for

VMs

-

VMware ESX Server i 5.5

Windows and Linux.

-Microsoft Hyper-V (Hyper-V Server 2008 R2 SP1)

-KVM RH 6.5

4

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

System requirements

1

Memory requirements

Memory requirements are only applicable when no other applications are running on the Network Advisor server. Paging space should be equal to or exceed the physical memory size. Network Advisor servers for Enterprise and Professional Plus editions are only supported on 64-bit systems. Network Advisor clients are supported on 32-bit and 64-bit Windows and Linux systems.

Operating system cache requirements

It is recommended that you use the System managed size (the OS allocates the required cache); however, if you choose to use a custom size, make sure you use the following memory settings for your operating system.

The virtual memory requirements for Windows system is 1 GB for minimum paging file size and 4 GB for maximum paging file size

TABLE 6

Linux swap space requirements

 

 

Installed physical memory

Recommended swap size

(RAM) size

 

 

 

 

 

4 GB

 

4 GB

 

 

Greater than 4 GB and

Equal to the amount of RAM

less than 8 GB

 

 

 

Greater than or equal to

5 time the amount of RAM

8 GB and less than 64

 

GB

 

 

 

 

 

NOTE

It is recommended that the memory allocation for ports exceeding 9000 is 6GB.

Disk space requirements

The disk space required for your device is a minimum of 10 GB.

NOTE

A warning message will be displayed if a minimum of 10 GB space is not available.

NOTE

It is recommended that you add an additional 100 GB of disk space if you use sFlow.

NOTE

It is recommended that you add an additional 40 GB of disk space for the default temporary directory.

Brocade Network Advisor Installation and Migration Guide

5

53-1003157-01

 

Brocade Network Advisor User Manual

1 System requirements

NOTE

It is recommended that you add an additional 100 GB of disk space if you use sFlow.

NOTE

If you enable periodic supportSave or configure the Network Advisor server as the Upload Failure Data Capture location for monitored switches, then additional disk space will be required. Each switch supportSave file is approximately 5 MB and each Upload Failure Data Capture file is approximately 500 KB. To determine the disk space requirements, multiply the frequency of scheduled supportSave files by 5 MB and the expected Upload Failure Data Capture files by 500 KB before the planned periodic purge activity.

Table 7 summarizes the host, memory and disk space requirements for remote client.

TABLE 7 Host, Memory, and Disk space requirements for remote client

Resources

Required

 

 

RAM

4 GB

 

 

Processor Core

2 core CPU

 

 

Disk space

1 GB

 

 

Table 8 summarizes the minimum system requirements for installation.

TABLE 8

Minimum system requirements for installation

 

 

 

 

 

Resources

 

Professional Edition

Enterprise Edition

 

 

 

 

RAM

 

4 GB(32-bit) 6GB (64 bit)

6 GB

 

 

 

Processor Core (including

2 core

2 core

physical and logical core)

 

 

 

 

 

 

Disk space

 

10 GB

20 GB

 

 

 

 

Table 9 summarizes the recommended system requirements for installation.

TABLE 9

Recommended system requirements for installation

 

 

 

 

 

 

Resources

 

Small

Medium

Large

 

 

 

 

 

RAM

 

16 GB

16 GB

16 GB

 

 

 

 

Processor Core (including

2 core

4 core

8 core

physical and logical core)

 

 

 

 

 

 

 

 

Disk space

 

20 GB

80 GB

100 GB

 

 

 

 

 

NOTE

You must have 16 core processor when managing 9000 SAN ports or above.

NOTE

It is recommended to allocate a minimum of 2 GB client memory and 6 GB server memory to efficiently manage more than 9000 ports.

6

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

System requirements

1

Browser requirements

The launch of Network Advisor and the launch of Element Manager (Web Tools) from the application are supported from the following browsers with a Java plug-in:

Browsers

-Windows Internet Explorer 11

-Firefox 27 on Windows or Linux

-Google Chrome 33

Java Plug-ins

-Oracle JRE 1.7.0 update 60 for Network Advisor

-Oracle JRE 1.7.0 update 60 for Web Tools

NOTE

For higher performance, use a 64-bit JRE.

NOTE

A warning message will be displayed if the required operating system is not available.

NOTE

If the minimum system requirement is not met, you will be blocked from the configuration and an error message will be displayed.

For the website listing patch information, go to http://www.oracle.com/technetwork/java/javase/downloads/index.html.

Client and server system requirements

NOTE

Network Advisor is not supported in a Network Address Translation (NAT) environment where the server and client are on different sides of the NAT Server.

Network Advisor has the following client and server system requirements:

In the Professional edition, a single server supports a single client, which must be a local client only.

In Professional Plus and Enterprise editions, a single server supports a maximum of 25 clients, which can be local or remote on 32-bit and 64-bit servers.

In Professional Plus and Enterprise editions, a single server supports a maximum of 25 clients, which can be local or remote on 64-bit servers. To support more than 8 clients, you must make the following changes to your configuration:

-Increase the server memory size. You can configure the server memory size from the Options dialog box, Memory Allocations pane. For instructions, refer to the Network Advisor User Manual or online help.

-Increase the PostgreSQL database shared buffers memory allocation to 1024 MB by editing the Install_Home\data\databases\postgresql.conf file.

Brocade Network Advisor Installation and Migration Guide

7

53-1003157-01

 

1 Downloading the software

Downloading the software

You can download the software and documentation from the MyBrocade website.

1.Go to the MyBrocade website. http://my.brocade.com/

2.Enter your user ID and password.

If you do not already have a MyBrocade account, you can create one.

3.Select MyBrocade from the Take me to list, if necessary.

4.Click LOG IN.

5.Click downloads on the main page.

6.Select Management Software from the Download by list.

7.Click Brocade Network Advisor in the Product Name list.

8.Select the highest version number for the latest GA code.

For example, click Brocade Network Advisor 12.3.x, then click Brocade Network Advisor 12.3.0 Brocade GA.

To download the documentation, click Brocade Network Advisor 12.3.0 Manuals and then select the manual you want to download.

9.Select one of the following links to download the software:

Network Advisor 12.3.0 GA for Windows

Network Advisor 12.3.0 GA for Linux

You can also access the release notes and md5 Checksum from this location.

10.Read the Export Compliance, select the certification check box, and click Submit.

11.Read the Brocade End User License Agreement and click I Accept.

12.Click Save on the File Download dialog box.

13.Browse to the location where you want to save the software and click Save.

Pre-installation requirements

Before you install Network Advisor, make sure you meet the following requirements.

Make sure all system requirements have been met prior to installation. For specific system requirements, refer to “System requirements” on page 1.

If you are running Professional Plus or Enterprise edition on a 32-bit machine, you must migrate to a 64-bit machine within your current release, then you can migrate to Network Advisor 12.3.

If you are running SAN with SMI Agent + IP on a 32-bit machine, you must migrate to a 64-bit machine within your current release, then you can migrate to Network Advisor 12.3.

To avoid errors, close all instances of the application before beginning the installation or uninstallation procedures.

8

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01

Installing the application

1

For UNIX system, if you still receive error messages after closing the application, enter the following commands:

#ps -ef | grep -i “” to list the process IDs

#kill -9Process_IDwhere Process_ID is any Management application process

Additional pre-installation requirements for UNIX systems

Make sure that an X Server is available for display and is configured to permit X Client applications to display from the host on which they are installing the Network Advisor server (typically, this simply requires that the systems console be present and running with a logged-in user on the X Server-based desktop session, such as KDE, GNOME, and so on).

If this is a headless unit with no console, refer to “Additional pre-installation requirements for UNIX systems (headless installation)” on page 12.

Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value (for example, to display to the local console, export DISPLAY=:0.0, or to display to a remote system that has an X Server running, export DISPLAY=Remote_IP_address:0.0).

You may also need to consider a firewall that might block the display to the X Server, which listens by default on TCP port 6000 on the remote host.

To display to a remote system, you need to permit the remote display of the X Server by running the xhost +IP command, where IP is the IP address of the Network Advisor server host from the X-based desktop of the remote system.

Make sure you test the DISPLAY definition by running the xterm command, from the same shell from which you run install.bin. A new X terminal window to the destination X Server display should open.

For Linux OS with the SELinux security policy enabled, make sure you complete the following steps.

1.Disable the SELinux security policy using the setenforce 0 command.

2.Install the application (refer to “Installing the application” on page 9).

3.Enable the SELinux security policy using the setenforce 1 command.

Installing the application

Before you install the application, make sure your system meets the minimum pre-installation requirements (refer to “Pre-installation requirements” on page 8). If you are migrating data, refer to “Data Migration” on page 39.

NOTE

SAN with SMI Agent + IP is not supported on 32-bit Windows systems. For more information, refer to “Pre-migration requirements” on page 44.

NOTE

On Windows systems, you must be an Administrator with Read and Write privileges to install Network Advisor.

Brocade Network Advisor Installation and Migration Guide

9

53-1003157-01

 

1 Installing the application

NOTE

On UNIX systems, you must be the root user to install Network Advisor.

To install the new application version, complete the following steps.

1.Choose one of the following options:

For Windows systems, open this file:

Download_Location\Application_Name\windows\install.exe.

For UNIX systems, complete the following steps.

a.On the Management application server, go to the following directory:

Download_Location/Application_Name/UNIX_Platform/bin

b.Type the following at the command line:

ulimit -n 2000

c.Type the following at the command line:

./install.bin

OR

sh install.bin

NOTE

On Linux systems, if you double-click the install.bin file, select Run. Do not select Run in Terminal.

The following are the list of folder permission in Linux:

BNA_HOME - 775

Conf/schema folder(including sub-folders) - 775

Conf folder - 775

Data folder - 775

Database folder - 700

DB folder (including sub folder) - 775

Temp folder -775

support folder - 777

Other folders -774

2.Click Next on the Introduction screen.

3.Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement, and click Next.

4.Select the usual location for your system application files (for example, D:\Program Files\Application_Name or opt/Application_Name) on the Select Install Folder screen and click Next.

NOTE

Do not install to the root directory C:\ (Windows) or / (UNIX).

5.Review the displayed installation summary on the Pre-Installation Summary screen and click Install.

10

Brocade Network Advisor Installation and Migration Guide

 

53-1003157-01