53-1003157-01 |
® |
11 July 2014
Brocade Network Advisor
Installation and Migration Guide
Supporting Network Advisor 12.3.0
© 2014, Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, the B-wing symbol, Brocade Assurance, ADX, AnyIO, DCX, Fabric OS, FastIron, HyperEdge, ICX, MLX, MyBrocade, NetIron, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and The Effortless Network and the On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and in other countries. Other brands and product names mentioned may be trademarks of others.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it.
The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters |
Asia-Pacific Headquarters |
|
||
Brocade Communications Systems, Inc. |
Brocade Communications Systems China HK, Ltd. |
|||
130 Holger Way |
No. 1 Guanghua Road |
|
|
|
San Jose, CA 95134 |
Chao Yang District |
|
|
|
Tel: 1-408-333-8000 |
Units 2718 and 2818 |
|
|
|
Fax: 1-408-333-8101 |
Beijing 100020, China |
|
|
|
E-mail: info@brocade.com |
Tel: +8610 6588 8888 |
|
|
|
|
Fax: +8610 6588 9999 |
|
|
|
|
E-mail: china-info@brocade.com |
|
||
European Headquarters |
Asia-Pacific Headquarters |
|
||
Brocade Communications Switzerland Sàrl |
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) |
|||
Centre Swissair |
Citic Plaza |
|
|
|
Tour B - 4ème étage |
No. 233 Tian He Road North |
|
||
29, Route de l'Aéroport |
Unit 1308 – 13th Floor |
|
|
|
Case Postale 105 |
Guangzhou, China |
|
|
|
CH-1215 Genève 15 |
Tel: +8620 3891 2000 |
|
|
|
Switzerland |
Fax: +8620 3891 2111 |
|
|
|
Tel: +41 22 799 5640 |
E-mail: china-info@brocade.com |
|
||
Fax: +41 22 799 5641 |
|
|
|
|
E-mail: emea-info@brocade.com |
|
|
|
|
Document History |
|
|
|
|
|
|
|
|
|
Title |
|
Publication number |
Summary of changes |
Date |
|
|
|
|
|
Brocade Network Advisor Installation and Migration Guide |
53-1002570-01 |
New document |
August 2012 |
|
|
|
|
|
|
Brocade Network Advisor Installation and Migration Guide |
53-1002699-01 |
Update for 12.0 |
December 2012 |
|
|
|
|
|
|
Brocade Network Advisor Installation and Migration Guide |
53-1002950-01 |
Update for 12.1 |
July 2013 |
|
|
|
|
|
|
Brocade Network Advisor Installation and Migration Guide |
53-1003059-01 |
Update for 12.2.0 |
February 2014 |
|
|
|
|
|
|
Brocade Network Advisor Installation and Migration Guide |
53-1003157-01 |
Update for 12.3.0 |
July 2014 |
|
|
|
|
|
|
Contents
About This Document
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . viii Fabric OS hardware and software support . . . . . . . . . . . . . . . . viii IronWare OS hardware and software support . . . . . . . . . . . . . . . xi Network OS hardware and software support. . . . . . . . . . . . . . . xiv
What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Key terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii Brocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii Other industry resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Chapter 1 |
Installation |
|
|
System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
1 |
|
Server and client operating system requirements . . . . . . . . . . . |
2 |
|
Memory requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5 |
|
Operating system cache requirements . . . . . . . . . . . . . . . . . . . . |
5 |
|
Disk space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
5 |
|
Browser requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
7 |
|
Client and server system requirements . . . . . . . . . . . . . . . . . . . . |
7 |
|
Downloading the software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
8 |
Pre-installation requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Additional pre-installation requirements for UNIX systems. . . . . 9
Installing the application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Mapping the loopback address to the local host . . . . . . . . . . . 11
Headless installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Additional pre-installation requirements for UNIX systems (headless installation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Performing a headless installation on Windows
and UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Troubleshooting the Linux headless installation . . . . . . . . . . .13
Brocade Network Advisor Installation and Migration Guide |
iii |
53-1003157-01 |
|
Client-only installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Installing the client-only application . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 2 |
Network Advisor Configuration |
|
|
Configuring Network Advisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
15 |
Accessing the Network Advisor interfaces . . . . . . . . . . . . . . . . . . . .22 Logging into a server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Launching a remote client. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Launching the SMC on Windows . . . . . . . . . . . . . . . . . . . . . . . . 24 Launching the SMC on Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Launching the SMIA Configuration Tool . . . . . . . . . . . . . . . . . . . 24 Launching the SMIA Configuration Tool remote client . . . . . . . 24
Syslog troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Finding the process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Stopping the process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Installing the ODBC driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Installing the ODBC driver on Windows systems . . . . . . . . . . . .26 Installing the ODBC driver on Linux systems . . . . . . . . . . . . . . . 27
Smart Card driver installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Installing the Smart Card driver on the local client . . . . . . . . . .30 Installing the Smart Card driver on the remote client . . . . . . . .32 Detecting and correcting a default Linux Smart Card driver. . .32
Configuring an explicit server IP address . . . . . . . . . . . . . . . . . . . . .34
Product improvement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Enabling product improvement data transfer . . . . . . . . . . . . . .35 Disabling product improvement data transfer . . . . . . . . . . . . . .36 Data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Configuring remote client access to the database . . . . . . . . . . . . . . 37
Chapter 3 |
Data Migration |
|
|
Upgrading the license . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
39 |
Supported migration paths. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 DCFM migration paths. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 INM migration paths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 EFCM and Fabric Manager migration paths . . . . . . . . . . . . . . .44
Pre-migration requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 Pre-migration requirements when migrating from
one server to another . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 Additional pre-migration requirements on UNIX systems . . . . . 47 Additional trial requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Migrating data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Cross flavor migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 Migration rollback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
iv |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
Chapter 4 |
Uninstallation |
|
|
Uninstalling from Windows systems . . . . . . . . . . . . . . . . . . . . . . . . . |
57 |
|
Uninstalling from Windows systems (headless uninstall) . . . . . . . . |
58 |
|
Uninstalling from UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
58 |
|
Uninstalling from UNIX systems (headless uninstall) . . . . . . . . . . . . |
59 |
Appendix A |
References |
|
|
Network Advisor packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
61 |
|
Edition feature support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
62 |
|
Management server and client ports . . . . . . . . . . . . . . . . . . . . . . . . |
72 |
|
Scalability limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
75 |
Brocade Network Advisor Installation and Migration Guide |
v |
53-1003157-01 |
|
vi |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
•How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
vii |
•Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
viii |
•What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
xv |
•Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
xvi |
•Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
xvii |
•Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
xvii |
•Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
xviii |
•Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
xix |
This document is organized to help you find the information that you want as quickly and easily as possible.
The document contains the following components:
•Chapter 1, “Installation,” provides system and pre-installation requirements as well as step-by-step installation instructions.
•Chapter 2, “Network Advisor Configuration,” provides step-by-step instructions to configure a fresh Network Advisor installation.
•Chapter 3, “Data Migration,” provides pre-migration requirements as well as step-by-step instructions for migrating data from a previous release of Network Advisor.
•Chapter 4, “Uninstallation,” provides step-by-step instructions for performing a partial or full uninstall of Network Advisor.
•Appendix A, “References,” provides the following information for quick lookup:
-Network Advisor packages
-Edition feature support
-Management server and client ports
-Scalability limits
Brocade Network Advisor Installation and Migration Guide |
vii |
53-1003157-01 |
|
In those instances in which procedures or parts of procedures documented here apply to some devices but not to others, this guide identifies exactly which devices are supported and which are not.
Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Network Advisor 12.3.X, documenting all possible configurations and scenarios is beyond the scope of this document.
The following firmware platforms are supported by this release of Network Advisor 12.3.X:
•Fabric OS 5.0 or later in a pure Fabric OS fabric
•Fabric OS 6.0 or later in a mixed fabric
NOTE
Discovery of a Secure Fabric OS fabric in strict mode is not supported.
The hardware platforms in Table 1 are supported by this release of Network Advisor 12.3.X.
TABLE 1 |
Fabric OS-supported hardware |
|
|
|
|
|
|
Device name |
|
Terminology used in documentation |
Firmware level required |
|
|
|
|
Brocade 200E switch |
16-port, 4 Gbps FC Switch |
|
|
|
|
|
|
Brocade 300 switch |
24-port, 8 Gbps FC Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
Brocade 4012 switch |
Embedded 12-port, 4 Gbps FC Switch |
|
|
|
|
|
|
Brocade 4016 switch |
Embedded 16-port, 4 Gbps FC Switch |
|
|
|
|
|
|
Brocade 4018 switch |
Embedded 18-port, 4 Gbps FC Switch |
|
|
|
|
|
|
Brocade 4020 switch |
Embedded 20-port, 4 Gbps FC Switch |
|
|
|
|
|
|
Brocade 4024 switch |
Embedded 24-port, 4 Gbps FC Switch |
Fabric OS v5.3.1 or later |
|
|
|
|
|
Brocade 4100 switch |
32-port, 4 Gbps FC Switch |
|
|
|
|
|
|
Brocade 4900 switch |
64-port, 4 Gbps FC Switch |
Fabric OS v5.2.0 or later |
|
|
|
|
|
Brocade 5000 switch |
32-port, 4 Gbps FC Interop Switch |
Fabric OS v5.2.1 or later |
|
|
|
|
|
Brocade 5100 switch |
40-port, 8 Gbps FC Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
Brocade 5300 switch |
80-port, 8 Gbps FC Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
Brocade 5410 embedded switch |
Embedded 12-port, 8 Gbps Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
Brocade 5424 embedded switch |
Embedded 24-port, 8 Gbps Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
Brocade 5431 embedded switch |
Embedded 16-port, 8 Gbps Stackable Switch |
Fabric OS v7.2.0 or later |
|
|
|
|
|
Brocade 5450 embedded switch |
Embedded 16-port, 8 Gbps Switch |
Fabric OS v6.2.0 or later |
|
|
|
|
|
Brocade 5460 embedded switch |
Embedded 24-port, 8 Gbps Switch |
Fabric OS v6.1.0_emb or later |
|
|
|
|
|
Brocade 5470 embedded switch |
Embedded 24-port, 8 Gbps Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
Brocade 5480 embedded switch |
Embedded 24-port, 8 Gbps Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
Brocade 6505 switch |
24-port, 16 Gbps Edge switch |
Fabric OS v7.0.1 or later |
viii |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
TABLE 1 |
Fabric OS-supported hardware (Continued) |
|
||
|
|
|
|
|
Device name |
|
Terminology used in documentation |
Firmware level required |
|
|
|
|
||
Brocade M6505 embedded switch |
24-port, 16 Gbps embedded switch |
Fabric OS v7.2.0 or later |
||
|
|
|
||
Brocade 6510 switch |
48-port, 16 Gbps switch |
Fabric OS v7.0.0 or later |
||
|
|
|
||
Brocade 6520 switch |
96-port, 16 Gbps switch |
Fabric OS v7.1.0 or later |
||
|
|
|
||
Brocade 6547 embedded switch |
48-port, 16 Gbps embedded switch |
Fabric OS v7.2.0 or later |
||
|
|
|
|
|
Brocade 7500 Extension switch |
4 |
Gbps Router, Extension Switch |
Fabric OS v5.1.0 or later |
|
|
|
|
|
|
Brocade 7500E Extension switch |
4 |
Gbps Extension Switch |
Fabric OS v5.1.0 or later |
|
|
|
|
|
|
FR4-18i Blade |
4 |
Gbps Router, Extension blades |
|
|
|
|
|
|
|
FX8-24 Blade |
|
8 |
Gbps Router, Extension blades |
Fabric OS v6.4.0 or later |
|
|
|
|
|
Brocade AP7600 switch |
4 |
Gbps 32-port Switch |
Fabric OS v6.1.0 or later |
|
|
|
|
|
|
Brocade 7800 switch |
8 |
Gbps Extension Switch |
Fabric OS v6.3.0 or later |
|
|
|
|
||
Brocade 7840 switch |
16 Gbps 24-FC port, 18 GbE port Switch |
Fabric OS v7.3.0 or later |
||
|
|
|
|
|
Brocade 8000 switch |
8 |
Gbps 8-FC port, 10 GbE 24-DCB port Switch |
Fabric OS v6.1.2_CEE |
|
|
|
|
||
Brocade 8470 FCoE embedded switch |
FCoE Embedded Switch |
Fabric OS v6.3.1_CEE |
||
|
|
|
|
|
Brocade VA-40FC switch |
8 |
Gbps 40-port Switch |
|
|
|
|
|
|
|
Brocade 415 Host Bus Adapter |
4 |
Gbps 1-port HBA |
|
|
|
|
|
|
|
Brocade 425 Host Bus Adapter |
4 |
Gbps 2-port HBA |
|
|
|
|
|
|
|
Brocade 815 Host Bus Adapter |
8 |
Gbps 1-port HBA |
|
|
|
|
|
|
|
Brocade 825 Host Bus Adapter |
8 |
Gbps 2-port HBA |
|
|
|
|
|
||
Brocade 1860 Fabric Adapter |
16 Gbps FC HBA mode |
Adapter Software 3.0.0.0 or later |
||
|
|
10 Gbps CNA mode |
|
|
|
|
10 Gbps NIC mode |
|
|
|
|
|
||
Brocade 1867 HBA |
16 Gbps Mezzanine HBA |
Adapter Software 3.0.3.0 or later |
||
|
|
|
||
Brocade 48000 director |
Director Chassis |
|
||
|
|
|
||
Brocade 48000 director with FC4-16, FC4-32, |
Director Chassis with 4 Gbps 16-FC port, 4 Gbps |
Fabric OS v5.2.0 or later (FC4-48) |
||
and FC4-48 Blades |
32-FC port, and 4 Gbps 48-FC port |
|
||
|
|
|
||
Brocade 48000 director with FR4-18i Blades |
Director Chassis with 4 Gbps router, extension |
Fabric OS v5.1.0 or later (FR4-18i) |
||
|
|
blades |
|
Brocade 48000 director with FC4-16IP Blades |
Director Chassis with 4 Gbps 8-FC port and 8 |
|
GbE iSCSI blades |
Fabric OS v5.2.0 or later (FC4-16IP)
Brocade 48000 director with FC10-6 Blades |
Director Chassis with 10 Gbps 6-port ISL blades |
Fabric OS v5.3.0 or later (FC10-6) |
|
|
|
Brocade DCX 1, 2 |
8-slot Backbone Chassis |
Fabric OS v6.0.0 or later |
Brocade DCX 1, 2 with FC8-16, FC8-32, and |
8-slot Backbone Chassis with 8 Gbps 16-FC port, |
Fabric OS v6.0.0 or later |
FC8-48 Blades |
8 Gbps 32-FC port, and 8 Gbps 48-FC port |
|
|
blades |
|
|
|
|
Brocade DCX 1, 2 with FC8-64 Blades |
8-slot Backbone Chassis with 8 Gbps 64-FC port |
Fabric OS v6.4.0 |
|
blades |
|
|
|
|
Brocade DCX 1, 2 with FR4-18i Blades |
8-slot Backbone Chassis with 4 Gbps Router, |
Fabric OS v6.0.0 or later |
|
Extension blade |
|
|
|
|
Brocade DCX 1, 2 with FC10-6 Blades |
8-slot Backbone Chassis with FC 10 - 6 ISL Blade |
Fabric OS v6.2.0 |
Brocade Network Advisor Installation and Migration Guide |
ix |
53-1003157-01 |
|
TABLE 1 |
Fabric OS-supported hardware (Continued) |
|
|
|
|
|
|
Device name |
|
Terminology used in documentation |
Firmware level required |
|
|
|
|
Brocade DCX 1, 2 with FS8-18 Blades |
8-slot Backbone Chassis with Encryption Blade |
Fabric OS v6.1.1_enc or later |
|
Brocade DCX 1, 2 with FX8-24 Blades |
8-slot Backbone Chassis with 8 Gbps 12-FC port, |
Fabric OS v6.3.1_CEE |
|
|
|
10 GbE ports, 2-10 GbE ports blade |
|
|
|
|
|
Brocade DCX-4S with FC16-64 Blades |
4-slot Backbone Chassis with 16 Gbps 64-FC |
Fabric OS v7.3.0 or later |
|
|
|
port blades |
|
|
|
|
|
Brocade DCX 1, 2 with FCoE10-24 Blades |
8-slot Backbone Chassis with 10 Gbps 24-port |
Fabric OS v6.3.1_CEE |
|
|
|
FCoE blade |
|
|
|
|
|
Brocade DCX-4S |
4-slot Backbone Chassis |
Fabric OS v6.0.0 or later |
|
|
|
|
|
Brocade DCX-4S with FC8-16, FC8-32, and |
4-slot Backbone Chassis with 8 Gbps 16-FC port, |
Fabric OS v6.2.0 |
|
FC8-48 Blades |
8 Gbps 32-FC port, and 8 Gbps 48-FC port |
|
|
|
|
blades |
|
|
|
|
|
Brocade DCX-4S with FC8-64 Blades |
4-slot Backbone Chassis with 8 Gbps 64-FC port |
Fabric OS v6.4.0 |
|
|
|
blades |
|
|
|
|
|
Brocade DCX-4S with FR4-18i Blades |
4-slot Backbone Chassis with 4 Gbps Router, |
Fabric OS v6.2.0 |
|
|
|
Extension blade |
|
|
|
|
|
Brocade DCX-4S with FC10-6 Blades |
4-slot Backbone Chassis with FC 10 - 6 ISL Blade |
Fabric OS v6.2.0 |
|
|
|
|
|
Brocade DCX-4S with FS8-18 Blades |
4-slot Backbone Chassis with Encryption Blade |
Fabric OS v6.1.1_enc or later |
|
|
|
|
|
Brocade DCX-4S with FX8-24 Blades |
4-slot Backbone Chassis with 8 Gbps 12-FC port, |
Fabric OS v6.3.1_CEE |
|
|
|
10 GbE ports, 2-10 GbE ports blade |
|
|
|
|
|
Brocade DCX-4S with FCoE10-24 Blades |
4-slot Backbone Chassis with 10 Gbps 24-port |
Fabric OS v6.3.0 or later |
|
|
|
FCoE blade |
|
|
|
|
|
Brocade DCX 8510-4 |
16 Gbps 4-slot Backbone Chassis |
Fabric OS v7.0.0 or later |
|
|
|
|
|
Brocade DCX 8510-81, 2 |
16 Gbps 8-slot Backbone Chassis |
Fabric OS v7.0.0 or later |
|
Brocade Encryption Switch |
8 Gbps Encryption Switch |
Fabric OS v6.1.1_enc or later |
|
|
|
|
|
FS8-18 Encryption Blade |
Encryption Blade |
|
|
|
|
|
|
FA4-18 Application Platform Blade |
Application Platform Blade |
|
|
|
|
|
|
FC8-16 Blade |
|
FC 8 GB 16-port Blade |
|
|
|
|
|
FC8-32 Blade |
|
FC 8 GB 32-port Blade |
|
|
|
|
|
FC8-48 Blade |
|
FC 8 GB 48-port Blade |
|
|
|
|
|
FC8-64 Blade |
|
FC 8 GB 64-port Blade |
|
|
|
|
|
FC10-6 Blade |
|
FC 10 - 6 ISL Blade |
|
|
|
|
|
FC8-32E blade3 |
8 Gbps 32-port blade |
Fabric OS v7.0.1 or later |
|
FC8-48E blade3 |
8 Gbps 48-port blade |
Fabric OS v7.0.1 or later |
|
FC16-32 Blade |
16 Gbps 32-port blade |
Fabric OS v7.0.0 or later |
|
|
|
|
|
FC16-48 Blade |
16 Gbps 48-port blade |
Fabric OS v7.0.0 or later |
|
|
|
|
|
FC16-64 Blade |
16 Gbps 64-port blade |
Fabric OS v7.3.0 or later |
|
|
|
|
|
FCoE10-24 Blade |
10 Gbps FCoE Port Router Blade |
|
x |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
TABLE 1 |
Fabric OS-supported hardware (Continued) |
|
|
|
|
|
|
Device name |
|
Terminology used in documentation |
Firmware level required |
|
|
|
|
FX8-24 Blade 1, 2 |
8 Gbps Extension Blade |
|
1Professional can discover, but not manage this device. Use the device’s Element Manager, which can be launched from the Connectivity Map, to manage the device. This device cannot be used as a Seed switch.
2Professional Plus Trial and Licensed version can discover, but not manage, this device. Use the device’s Element Manager, which can be launched from the Connectivity Map, to manage the device. This device cannot be used as a Seed switch.
3Only supported on the DCX 8510-4 and DCX 8510-8 chassis.
The following firmware platforms are supported by this release of Network Advisor 12.3.X:
•BigIron 2.7.02e (sustaining mode) or later
•FastIron 7.2.0 or later
•NetIron 5.1.0 or later
•ServerIron (JetCore) 11.0 or later
•ServerIron ADX 12.2.0 or later
•TurboIron 4.2.0 or later
For platform-specific firmware requirements, refer to Table 2.
Table 2 lists the hardware platforms supported by this release of Network Advisor 12.3.X, the terminology used in the documentation, as well as any specific firmware requirements.
TABLE 2 |
IronWare OS-supported hardware |
|
|
|
|
|
|
Device name |
|
Terminology used in documentation |
Firmware level required |
|
|
|
|
BigIron family |
|
Ethernet Chassis |
BigIron 2.7.02e or 2.7.01b |
|
|
|
|
BigIron RX-4 (BI-RX-4-AC) |
Ethernet Chassis, 4 interface slots |
BigIron 2.7.02e or 2.7.01b |
|
|
|
|
|
BigIron RX-8 (BI-RX-8-AC) |
Ethernet Chassis, 8 interface slots |
BigIron 2.7.02e or 2.7.01b |
|
|
|
|
|
BigIron RX-16 (BI-RX-16-AC-A) |
Ethernet Chassis, 16 interface slots |
BigIron 2.7.02e or 2.7.01b |
|
|
|
|
|
Brocade 6910 Ethernet Access Switch |
Ethernet Access Switch |
release 2.0.2.7, loader version 1.0.1.3 |
|
|
|
|
|
FastIron family |
Ethernet switch |
See individual device. |
|
|
|
|
|
FastIron CX 624S (FCX624S) |
Ethernet L2/L3 Edge switch, 24 1GbE |
FastIron 06.0.00 and later |
|
|
|
RJ45 ports |
|
|
|
|
|
FastIron CX 648S (FCX648S) |
Ethernet L2/L3 Edge switch, 48 1GbE |
FastIron 06.0.00 and later |
|
|
|
RJ45 ports |
|
|
|
|
|
FastIron CX 624S-HPOE (FCX624S-HPOE) |
Ethernet L2/L3 Edge switch, 24 1GbE |
FastIron 06.0.00 and later |
|
|
|
RJ45 ports, 24 POE+ ports |
|
|
|
|
|
FastIron CX 648S-HPOE (FCX648S-HPOE) |
Ethernet L2/L3 Edge switch, 48 1GbE |
FastIron 06.0.00 and later |
|
|
|
RJ45 ports, 48 POE+ ports |
|
|
|
|
|
FastIron CX 624S-F (FCX624S-F) |
Ethernet L2/L3 Edge switch, 20 SFP ports |
FastIron 06.0.00 and later |
|
|
|
|
|
FastIron CX 624-E (FCX624-E) |
Ethernet L2/L3 Edge switch, 24 1GbE |
FastIron 06.0.00 and later |
|
|
|
RJ45 ports |
|
Brocade Network Advisor Installation and Migration Guide |
xi |
53-1003157-01 |
|
TABLE 2 IronWare OS-supported hardware (Continued)
Device name |
Terminology used in documentation |
Firmware level required |
|
|
|
FastIron CX 624-I (FCX624-I) |
Ethernet L2/L3 Edge switch, 24 1GbE |
FastIron 06.0.00 and later |
|
RJ45 ports |
|
|
|
|
FastIron CX 648-E (FCX648-E) |
Ethernet L2/L3 Edge switch, 48 1GbE |
FastIron 06.0.00 and later |
|
RJ45 ports |
|
|
|
|
FastIron CX 648-I (FCX648-I) |
Ethernet L2/L3 Edge switch, 48 1GbE |
FastIron 06.0.00 and later |
|
RJ45 ports |
|
|
|
|
ICX 6610 |
Ethernet L2/L3 Edge switch |
FastIron 07.0.3 and later |
|
|
|
ICX 643024 switch |
24-port Campus LAN switch |
FastIron 07.4.00 and later |
|
|
|
ICX 643024-HPOE switch |
24-port Campus LAN HPOE switch |
FastIron 07.4.00 and later |
|
|
|
ICX 643048 switch |
48-port Campus LAN switch |
FastIron 07.4.00 and later |
|
|
|
ICX 643048-HPOE switch |
48-port Campus LAN HPOE switch |
FastIron 07.4.00 and later |
|
|
|
ICX 645024 switch |
24-port Campus LAN switch |
FastIron 07.4.00 and later |
|
|
|
ICX 645024 Base L3 router |
24-port Campus LAN Base L3 router |
FastIron 07.4.00 and later |
|
|
|
ICX 645024 Base router |
24-port Campus LAN Base router |
FastIron 07.4.00 and later |
|
|
|
ICX 645024 Premium router |
24-port Campus LAN Premium router |
FastIron 07.4.00 and later |
|
|
|
ICX 645024-HPOE switch |
24-port Campus LAN HPOE switch |
FastIron 07.4.00 and later |
|
|
|
ICX 645024-HPOE Base L3 router |
24-port Campus LAN HPOE Base L3 router |
FastIron 07.4.00 and later |
|
|
|
ICX 645024-HPOE Base router |
24-port Campus LAN HPOE Base router |
FastIron 07.4.00 and later |
|
|
|
ICX 645024-HPOE Premium router |
24-port Campus LAN HPOE Premium |
FastIron 07.4.00 and later |
|
router |
|
|
|
|
ICX 645048 switch |
48-port Campus LAN switch |
FastIron 07.4.00 and later |
|
|
|
ICX 645048 Base L3 router |
48-port Campus LAN Base L3 router |
FastIron 07.4.00 and later |
|
|
|
ICX 645048 Base router |
48-port Campus LAN Base router |
FastIron 07.4.00 and later |
|
|
|
ICX 645048 Premium router |
48-port Campus LAN Premium router |
FastIron 07.4.00 and later |
|
|
|
ICX 645048-HPOE switch |
48-port Campus LAN HPOE switch |
FastIron 07.4.00 and later |
|
|
|
ICX 645048-HPOE Base L3 router |
48-port Campus LAN HPOE Base L3 router |
FastIron 07.4.00 and later |
|
|
|
ICX 645048-HPOE Base router |
48-port Campus LAN HPOE Base router |
FastIron 07.4.00 and later |
|
|
|
ICX 645048-HPOE Premium router |
48-port Campus LAN HPOE Premium |
FastIron 07.4.00 and later |
|
router |
|
|
|
|
ICX 6430 IronStack switch |
24-port Campus LAN switch |
FastIron 07.4.00 and later |
|
|
|
ICX 6430 IronStack Base L3 router |
Campus LAN Base L3 router |
FastIron 07.4.00 and later |
|
|
|
ICX 6430 IronStack Base router |
Campus LAN Base router |
FastIron 07.4.00 and later |
|
|
|
ICX 6430 IronStack Premium router |
Campus LAN Premium router |
FastIron 07.4.00 and later |
|
|
|
ICX 6450 IronStack switch |
48-port Campus LAN switch |
FastIron 07.4.00 and later |
|
|
|
ICX 7750-26Q switch |
26 10/40 GbE QSFP+ ports |
FastIron 08.0.10 and later |
|
|
|
ICX 7750-48F switch |
48 1/10 GbE SFP+ ports and six 10/40 |
FastIron 08.0.10 and later |
|
GbE QSFP+ ports |
|
xii |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
TABLE 2 IronWare OS-supported hardware (Continued)
Device name |
Terminology used in documentation |
Firmware level required |
|
|
|
ICX 7750-48C switch |
48 1/10 GbE RJ-45 ports and six 10/40 |
FastIron 08.0.10 and later |
|
GbE QSFP+ ports |
|
|
|
|
FastIron GS |
Ethernet L2/L3 Access switch |
|
|
|
|
FastIron GS-STK |
Ethernet L2/L3 Access switch, stackable |
|
|
|
|
FastIron LS |
Enterprise LAN switch |
|
|
|
|
FastIron LS-STK |
Enterprise LAN switch, stackable |
|
|
|
|
FastIron SuperX/SX |
Enterprise LAN chassis |
FSX 02.4.00 and later |
|
|
|
FastIron SX 800 and FastIron SX 1600 |
Enterprise LAN chassis |
FSX 02.4.00 and later |
|
|
|
FastIron 8-port 10 GbE SFP Blade |
8-port 10 GbE SFP Blade |
|
|
|
|
FastIron 24-port Fiber SFP GbE Blade |
24-port Fiber SFP GbE Blade |
|
|
|
|
FastIron 24-port GbE Cu Blade |
24-port GbE Cu Blade |
|
|
|
|
FastIron 2-port 10GbE SFP+ Blade |
2-port 10GbE SFP+ Blade |
|
|
|
|
FastIron Edge Switch X-Series |
Enterprise LAN Edge switch |
|
|
|
|
FastIron Edge X 424 |
Enterprise LAN Edge switch, 24 |
|
|
10/100/1000 Mbps ports |
|
|
|
|
FastIron Edge X 624 |
Enterprise LAN Edge switch, 24 |
|
|
10/100/1000 Mbps ports |
|
|
|
|
FastIron Edge X 448 |
Enterprise LAN Edge switch, 48 |
|
|
10/100/1000 Mbps ports |
|
|
|
|
FastIron Edge X 648 |
Enterprise LAN Edge switch, 48 |
|
|
10/100/1000 Mbps ports |
|
|
|
|
FastIron Edge X 424HF |
Enterprise LAN Edge switch, 20 100/1000 |
|
|
Mbps SFP ports |
|
|
|
|
FastIron Edge X 624HF |
Enterprise LAN Edge switch, 20 100/1000 |
|
|
Mbps SFP ports |
|
|
|
|
FastIron WS devices |
Enterprise Campus switch |
|
|
|
|
Motorola Controllers RFS4000 series |
Wireless controller |
Mobility 5.1 |
|
|
|
Motorola Controllers RFS6000 series |
Wireless controller |
Mobility 5.1 |
|
|
|
Motorola Controllers RFS7000 series |
Wireless controller |
Mobility 5.1 |
|
|
|
Motorola Access Point 7131 |
Wireless access point |
Mobility 4.1.1 (standalone mode) |
|
|
Mobility 5.1 1 (adaptive mode) |
Motorola Access Point 7131N |
Wireless access point |
Mobility 4.1.1 (standalone mode) |
|
|
Mobility 5.1 1 (adaptive mode) |
Motorola Access Point 5181 |
Wireless access point |
Mobility 2.5.X (standalone mode) |
|
|
Mobility 5.1 1 (adaptive mode) |
Motorola Access Point 6511 |
Wireless access point |
Mobility 5.1 1 (adaptive mode) |
NetIron family |
Ethernet routers |
NetIron 5.0.0 or 5.0.1 |
|
|
|
NetIron MLX |
Ethernet router |
NetIron 5.0.0 or 5.0.1 |
(Supported regardless of license |
|
|
configuration) |
|
|
Brocade Network Advisor Installation and Migration Guide |
xiii |
53-1003157-01 |
|
TABLE 2 IronWare OS-supported hardware (Continued)
Device name |
Terminology used in documentation |
Firmware level required |
|
|
|
NetIron MLXe |
Ethernet Core router |
NetIron 5.0.0 or 5.0.1 |
(Supported regardless of license |
|
|
configuration) |
|
|
|
|
|
NetIron XMR |
Ethernet Backbone router |
NetIron 5.0.0 or 5.0.1 |
(Supported regardless of license |
|
|
configuration) |
|
|
|
|
|
NetIron CES 2048CX (NI-CES-2048CX-AC) |
Ethernet Carrier router |
NetIron 5.0.0 or 5.0.1 |
(Supported regardless of license |
|
|
configuration) |
|
|
|
|
|
NetIron CER |
Ethernet Edge router |
NetIron 5.0.0 or 5.0.1 |
(Supported regardless of license |
|
|
configuration) |
|
|
|
|
|
NetIron XMR/MLX 2-Port 100Gbe Module |
2-Port 100Gbe Module |
NetIron 5.7.0 |
|
|
|
NetIron XMR/MLX 20-port 10GbE Module |
20-port 10GbE Module |
NetIron 5.7.0 |
|
|
|
ServerIron family |
Application product |
|
|
|
|
ServerIron ADX 1000 |
Application switch |
|
|
|
|
ServerIron ADX 1000F |
Application Fiber switch |
ADX 12.3.03 or later |
|
|
|
ServerIron ADX 4000 |
4U Application Delivery chassis |
ADX 12.1.00 or later |
|
|
|
ServerIron ADX 10000 |
10U Application Delivery chassis |
ADX 12.1.00 or later |
|
|
|
TurboIron Family |
Data Center switch |
4.1.00d or 4.2.00 or later |
|
|
|
TurboIron 24X (T1-24X-AC) |
Data Center switch |
4.1.00d or 4.2.00 or later |
|
|
|
Brocade 6650 Switch |
Data Center switch |
FastIron 7.5 and later |
|
|
|
Brocade 6650 Base L3 Router |
Data Center base L3 router |
FastIron 7.5 and later |
|
|
|
Brocade 6650 Router |
Data Center router |
FastIron 7.5 and later |
|
|
|
1 The Management application cannot discover or manage wireless access points running Mobility 5.1.
Network Advisor 12.3.X supports the Network OS 2.1 or later firmware platform. For platform-specific firmware requirements, if any, refer to the Table 3.
Table 3 lists the hardware platforms supported by this release of Network Advisor 12.3.X, the terminology used in the documentation, as well as any specific firmware requirements.
TABLE 3 |
Network OS-supported hardware |
|
|
|
|
|
|
Device name |
|
Terminology used in documentation |
Firmware level required |
|
|
|
|
Brocade VDX 2730 10 Gbps connection blade |
VDX 2730 10 Gbps connection blade |
2.1.1_fuj |
|
|
|
|
|
Brocade VDX 2740 switch |
VDX 2740 switch |
4.0.0_bbd |
|
|
|
|
|
Brocade VDX 6710 switch |
VDX 6710 switch |
2.1 or later |
|
|
|
|
|
Brocade VDX 6720-24 switch |
VDX 6720-24 switch |
2.1 or later |
|
|
|
|
|
Brocade VDX 6720-60 switch |
VDX 6720-60 switch |
2.1 or later |
xiv |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
TABLE 3 |
Network OS-supported hardware (Continued) |
|
|
|
|
|
|
Device name |
|
Terminology used in documentation |
Firmware level required |
|
|
|
|
Brocade VDX 6730-32 switch |
VDX 6730-32 switch |
2.1 or later |
|
|
|
|
|
Brocade VDX 6730-76 switch |
VDX 6730-76 switch |
2.1 or later |
|
|
|
|
|
Brocade VDX 6740 switch |
VDX 6740 switch |
4.0 or later |
|
|
|
|
|
Brocade VDX 6740T switch |
VDX 6740T switch |
4.0 or later |
|
|
|
|
|
Brocade VDX 6740T-1G switch |
VDX 6740T-1G switch |
4.1 or later |
|
|
|
|
|
Brocade VDX 8770-4 switch |
VDX 8770-4 switch |
3.0 or later |
|
|
|
|
|
Brocade VDX 8770-8 switch |
VDX 8770-8 switch |
3.0 or later |
|
|
|
|
|
Brocade VDX 8770 with 40G/10G Base-T by line card |
VDX 8770 switch with 40G/10G Base-T by line card |
4.1 or later |
|
|
|
|
|
The following changes have been made since this document was last released:
•Information that was added:
-Migration rollback
•Information that was changed:
-Supported hardware and software
-Server and Client operating system requirements
-Client only installation
-Supported migration paths
•Information that was deleted:
-None.
For further information about new features and documentation updates for this release, refer to the release notes.
Brocade Network Advisor Installation and Migration Guide |
xv |
53-1003157-01 |
|
This section describes text formatting conventions and important notice formats used in this document.
The narrative-text formatting conventions that are used are as follows:
bold text |
Identifies command names |
|
Identifies the names of user-manipulated GUI elements |
|
Identifies keywords and operands |
|
Identifies text to enter at the GUI or CLI |
italic text |
Provides emphasis |
|
Identifies variables |
|
Identifies paths and Internet addresses |
|
Identifies document titles |
code text |
Identifies CLI output |
|
Identifies command syntax examples |
For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is all lowercase.
The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
NOTE
A note provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information.
For definitions specific to Brocade and Fibre Channel, see the technical glossaries on MyBrocade. See “Brocade resources” on page xvii for instructions on accessing MyBrocade.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at:
http://www.snia.org/education/dictionary
xvi |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations.
These references are made for informational purposes only.
Corporation |
Referenced trademarks and products |
|
|
Linus Torvalds |
Linux |
|
|
Microsoft Corporation |
Windows, Windows NT, Internet Explorer |
|
|
Netscape Communications Corporation |
Netscape |
|
|
Red Hat, Inc. |
Red Hat, Red Hat Network, Maximum RPM, Linux Undercover |
|
|
Oracle |
Sun, Solaris, Sun Fire, Sun Ultra, Java Plug-in |
|
|
The Open Group |
UNIX |
|
|
VMware, Inc. |
VMware |
|
|
This section lists additional Brocade and industry-specific documentation that you might find helpful.
To get up-to-the-minute information, go to http://my.brocade.com to register at no cost for a user ID and password.
White papers, online demonstrations, and data sheets are available through the Brocade website at:
http://www.brocade.com/products-solutions/products/index.page
For additional Brocade documentation, visit the Brocade website: http://www.brocade.com
Release notes are available on the MyBrocade website.
For additional resource information, visit the Technical Committee T11 website. This website provides interface standards for high-performance and mass storage applications for Fibre Channel, storage management, and other applications:
http://www.t11.org
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association website:
http://www.fibrechannel.org
Brocade Network Advisor Installation and Migration Guide |
xvii |
53-1003157-01 |
|
Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available:
1.Management Application Serial Number
To obtain the Management application serial number, select Help > License. The License dialog box displays.
2.General Information
•Switch model
•Switch operating system version
•Software name and software version, if applicable
•Error numbers and messages received
•supportSave command output
•Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions
•Description of any troubleshooting steps already performed and the results
•Serial console and Telnet session logs
•syslog message logs
3.Switch Serial Number
The switch serial number and corresponding bar code are provided on the serial number label, as illustrated below:
FT00X0054E9
The serial number label is located as follows:
•Brocade 300, 4100, 4900, 5100, 5300, 7500, 7800, 8000, VA-40FC, and Brocade Encryption Switch—On the switch ID pull-out tab located inside the chassis on the port side on the left
•Brocade 5000—On the switch ID pull-out tab located on the bottom of the port side of the switch
•Brocade 7600—On the bottom of the chassis
•Brocade 48000—Inside the chassis next to the power supply bays
•Brocade DCX—On the bottom right on the port side of the chassis
•Brocade DCX-4S—On the bottom right on the port side of the chassis, directly above the cable management comb
xviii |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
4.World Wide Name (WWN)
Use the licenseIdShow command to display the WWN of the chassis.
If you cannot use the licenseIdShow command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis.
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to:
documentation@brocade.com
Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
Brocade Network Advisor Installation and Migration Guide |
xix |
53-1003157-01 |
|
xx |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
|
Chapter |
|
Installation |
1 |
|
|
|
|
In this chapter
•System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
•Downloading the software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
•Pre-installation requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
•Installing the application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
•Headless installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
•Client-only installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Use the following sections to determine if you have met the requirements for this application:
•Server and client operating system requirements . . . . . . . . . . . . . . . . . . . . . 2
•Memory requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
•Operating system cache requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
•Disk space requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
•Browser requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
•Client and server system requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Brocade Network Advisor Installation and Migration Guide |
1 |
53-1003157-01 |
|
1 System requirements
Table 4 summarizes the required operating system (OS) for servers and the packages supported by each OS version.
NOTE
Enterprise edition (SAN or IP) and Professional Plus edition (SAN or IP) are not supported on 32-bit operating systems. You must migrate to a 64-bit operating system.
NOTE
SAN with SMI Agent + IP edition is not supported on 32-bit operating systems.
TABLE 4 |
|
Server operating system requirements |
|
|
||
|
|
|
|
|
|
|
Operating |
Version |
|
|
Guest OS version |
Supported packages |
|
system |
|
|
|
|
|
|
|
|
|
|
|
|
|
Windows® |
- |
2008 |
Server (x86 32-bit) |
|
SAN with SMI Agent |
|
|
- |
7 Enterprise (x86 32-bit) |
|
IP only |
||
|
- |
2008 |
Server (x86 64-bit) |
|
SMI Agent only |
|
|
- |
7 Enterprise (x86 64-bit) |
|
|
||
|
- |
2008 |
R2 |
Data Center Edition (x86 32-bit) |
|
SAN with SMI Agent |
|
- |
2008 |
R2 |
Standard Edition (x86 32-bit) |
|
IP only |
|
- |
2008 |
R2 |
Enterprise Edition (x86 32-bit) |
|
SMI Agent only |
|
- |
2012 R2 Data Center Edition (x86 32-bit) |
|
SAN with SMI Agent + IP |
||
|
- |
2012 R2 Standard Edition (x86 32-bit) |
|
|
||
|
- |
7 Enterprise (x86 32-bit) |
|
|
||
|
- |
8 Enterprise (x86 32-bit) |
|
|
||
|
- |
8.1 Enterprise (x86 32-bit) |
|
|
||
|
- |
2008 |
R2 |
Data Center Edition (x86 64-bit) |
|
SAN with SMI Agent |
|
- |
2008 |
R2 |
Standard Edition (x86 64-bit) |
|
IP only |
|
- |
2008 |
R2 |
Enterprise Edition (x86 64-bit) |
|
SMI Agent only |
|
- |
2012 R2 Data Center Edition (x86 64-bit) |
|
SAN with SMI Agent + IP |
||
|
- |
2012 R2 Standard Edition (x86 64-bit) |
|
|
||
|
- |
7 Enterprise (x86 64-bit) |
|
|
||
|
- |
8 Enterprise (x86 64-bit) |
|
|
||
|
- |
8.1 Enterprise (x86 64-bit) |
|
|
2 |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
System requirements |
1 |
TABLE 4 |
|
Server operating system requirements (Continued) |
|
|
|
|
|
|
|
Operating |
Version |
Guest OS version |
Supported packages |
|
system |
|
|
|
|
|
|
|
|
|
Linux® |
- |
RedHat Enterprise 6.1 Advanced (x86 32-bit) |
|
SAN with SMI Agent |
|
- |
RedHat Enterprise 6.2 Advanced (x86 32-bit) |
|
IP only |
|
- |
RedHat Enterprise 6.3 Advanced (x86 32-bit) |
|
SMI Agent only |
|
- |
RedHat Enterprise 6.4 Advanced (x86 32-bit) |
|
|
|
- |
RedHat Enterprise 6.5 Advanced (x86 32-bit) |
|
|
|
- |
SuSE Enterprise Server 11 (x86 32-bit) |
|
|
|
- |
SuSE Enterprise Server 11.3 (x86 32-bit) |
|
|
|
- |
Oracle Enterprise 6.1 (x86 32-bit) |
|
|
|
- |
Oracle Enterprise 6.2 (x86 32-bit) |
|
|
|
- |
Oracle Enterprise 6.3 (x86 32-bit) |
|
|
|
- |
Oracle Enterprise 6.4 (x86 32-bit) |
|
|
|
- |
Oracle Enterprise 6.5 (x86 32-bit) |
|
|
|
- |
RedHat Enterprise 6.1 Advanced (x86 64-bit) |
|
SAN with SMI Agent |
|
- |
RedHat Enterprise 6.2 Advanced (x86 64-bit) |
|
IP only |
|
- |
RedHat Enterprise 6.3 Advanced (x86 64-bit) |
|
SMI Agent only |
|
- |
RedHat Enterprise 6.4 Advanced (x86 64-bit) |
|
SAN with SMI Agent + IP |
|
- |
RedHat Enterprise 6.5 Advanced (x86 64-bit) |
|
|
|
- |
SuSE Enterprise Server 11.3 (x86 64-bit) |
|
|
|
- |
Oracle Enterprise 6.1 (x86 64-bit) |
|
|
|
- |
Oracle Enterprise 6.2 (x86 64-bit) |
|
|
|
- |
Oracle Enterprise 6.3 (x86 64-bit) |
|
|
|
- |
Oracle Enterprise 6.4 (x86 64-bit) |
|
|
|
- |
Oracle Enterprise 6.5 (x86 64-bit) |
|
|
Guest VMs |
- |
VMware® ESX Server i 5.11 |
Supports all server |
Supports all packages |
|
- |
VMware ESX Server i 5.5 |
OS versions |
available for Windows |
|
- |
Microsoft Hyper-V (Hyper-V Server 2008 R2 SP1) |
available for |
and Linux. |
|
- |
KVM RH 6.5 |
Windows and |
|
|
|
|
Linux. |
|
1.It is recommended that you run all Network Advisor virtual CPUs on a single physical CPU.
Brocade Network Advisor Installation and Migration Guide |
3 |
53-1003157-01 |
|
1 System requirements
Table 5 summarizes the required OS for clients.
Client operating system requirements
Operating |
Version |
Guest OS version |
system |
|
|
-2008 Server (x86 32-bit)
®- 7 Enterprise (x86 32-bit)
-2008 Server (x86 64-bit)
-7 Enterprise (x86 64-bit)
-2008 R2 Data Center Edition (x86 32-bit)
-2008 R2 Standard Edition (x86 32-bit)
-2008 R2 Enterprise Edition (x86 32-bit)
-2012 R2 Data Center Edition (x86 32-bit)
-2012 R2 Standard Edition (x86 32-bit)
-7 Enterprise (x86 32-bit)
-8 Enterprise (x86 32-bit)
-8.1 Enterprise (x86 32-bit)
-2008 R2 Data Center Edition (x86 64-bit)
-2008 R2 Standard Edition (x86 64-bit)
-2008 R2 Enterprise Edition (x86 64-bit)
-2012 R2 Data Center Edition (x86 64-bit)
-2012 R2 Standard Edition (x86 64-bit)
-7 Enterprise (x86 64-bit)
-8 Enterprise (x86 64-bit)
-8.1 Enterprise (x86 64-bit)Windows
|
|
|
|
Linux® |
- |
RedHat Enterprise 6.1 Advanced (x86 32-bit) |
|
|
- RedHat Enterprise 6.2 Advanced (x86 32-bit) |
|
|
|
- |
RedHat Enterprise 6.3 Advanced (x86 32-bit) |
|
|
- |
RedHat Enterprise 6.4 Advanced (x86 32-bit) |
|
|
- |
RedHat Enterprise 6.5 Advanced (x86 32-bit) |
|
|
- |
SuSE Enterprise Server 11 (x86 32-bit) |
|
|
- |
SuSE Enterprise Server 11.3 (x86 32-bit |
|
|
- |
Oracle Enterprise 6.1 (x86 32-bit) |
|
|
- |
Oracle Enterprise 6.2 (x86 32-bit) |
|
|
- |
Oracle Enterprise 6.3 (x86 32-bit) |
|
|
- |
Oracle Enterprise 6.4 (x86 32-bit) |
|
|
- |
Oracle Enterprise 6.5 (x86 64-bit) |
|
|
- RedHat Enterprise 6.1 Advanced (x86 64-bit) |
|
|
|
- |
RedHat Enterprise 6.2 Advanced (x86 64-bit) |
|
|
- |
RedHat Enterprise 6.3 Advanced (x86 64-bit) |
|
|
- |
RedHat Enterprise 6.4 Advanced (x86 64-bit) |
|
|
- |
RedHat Enterprise 6.5 Advanced (x86 64-bit) |
|
|
- |
Oracle Enterprise 6.1 (x86 64-bit) |
|
|
- |
Oracle Enterprise 6.2 (x86 64-bit) |
|
|
- |
Oracle Enterprise 6.3 (x86 64-bit) |
|
|
- |
Oracle Enterprise 6.4 (x86 64-bit) |
|
|
- |
Oracle Enterprise 6.5 (x86 64-bit) |
|
Guest |
- |
VMware® ESX Server i 5.1 |
Supports all client OS versions available for |
VMs |
- |
VMware ESX Server i 5.5 |
Windows and Linux. |
-Microsoft Hyper-V (Hyper-V Server 2008 R2 SP1)
-KVM RH 6.5
4 |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
System requirements |
1 |
Memory requirements are only applicable when no other applications are running on the Network Advisor server. Paging space should be equal to or exceed the physical memory size. Network Advisor servers for Enterprise and Professional Plus editions are only supported on 64-bit systems. Network Advisor clients are supported on 32-bit and 64-bit Windows and Linux systems.
It is recommended that you use the System managed size (the OS allocates the required cache); however, if you choose to use a custom size, make sure you use the following memory settings for your operating system.
The virtual memory requirements for Windows system is 1 GB for minimum paging file size and 4 GB for maximum paging file size
TABLE 6 |
Linux swap space requirements |
|
|
|
|
Installed physical memory |
Recommended swap size |
|
(RAM) size |
|
|
|
|
|
4 GB |
|
4 GB |
|
|
|
Greater than 4 GB and |
Equal to the amount of RAM |
|
less than 8 GB |
|
|
|
|
|
Greater than or equal to |
5 time the amount of RAM |
|
8 GB and less than 64 |
|
|
GB |
|
|
|
|
|
NOTE
It is recommended that the memory allocation for ports exceeding 9000 is 6GB.
The disk space required for your device is a minimum of 10 GB.
NOTE
A warning message will be displayed if a minimum of 10 GB space is not available.
NOTE
It is recommended that you add an additional 100 GB of disk space if you use sFlow.
NOTE
It is recommended that you add an additional 40 GB of disk space for the default temporary directory.
Brocade Network Advisor Installation and Migration Guide |
5 |
53-1003157-01 |
|
1 System requirements
NOTE
It is recommended that you add an additional 100 GB of disk space if you use sFlow.
NOTE
If you enable periodic supportSave or configure the Network Advisor server as the Upload Failure Data Capture location for monitored switches, then additional disk space will be required. Each switch supportSave file is approximately 5 MB and each Upload Failure Data Capture file is approximately 500 KB. To determine the disk space requirements, multiply the frequency of scheduled supportSave files by 5 MB and the expected Upload Failure Data Capture files by 500 KB before the planned periodic purge activity.
Table 7 summarizes the host, memory and disk space requirements for remote client.
TABLE 7 Host, Memory, and Disk space requirements for remote client
Resources |
Required |
|
|
RAM |
4 GB |
|
|
Processor Core |
2 core CPU |
|
|
Disk space |
1 GB |
|
|
Table 8 summarizes the minimum system requirements for installation.
TABLE 8 |
Minimum system requirements for installation |
|
|
|
|
|
|
Resources |
|
Professional Edition |
Enterprise Edition |
|
|
|
|
RAM |
|
4 GB(32-bit) 6GB (64 bit) |
6 GB |
|
|
|
|
Processor Core (including |
2 core |
2 core |
|
physical and logical core) |
|
|
|
|
|
|
|
Disk space |
|
10 GB |
20 GB |
|
|
|
|
Table 9 summarizes the recommended system requirements for installation.
TABLE 9 |
Recommended system requirements for installation |
|
||
|
|
|
|
|
Resources |
|
Small |
Medium |
Large |
|
|
|
|
|
RAM |
|
16 GB |
16 GB |
16 GB |
|
|
|
|
|
Processor Core (including |
2 core |
4 core |
8 core |
|
physical and logical core) |
|
|
|
|
|
|
|
|
|
Disk space |
|
20 GB |
80 GB |
100 GB |
|
|
|
|
|
NOTE
You must have 16 core processor when managing 9000 SAN ports or above.
NOTE
It is recommended to allocate a minimum of 2 GB client memory and 6 GB server memory to efficiently manage more than 9000 ports.
6 |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
System requirements |
1 |
The launch of Network Advisor and the launch of Element Manager (Web Tools) from the application are supported from the following browsers with a Java plug-in:
•Browsers
-Windows Internet Explorer 11
-Firefox 27 on Windows or Linux
-Google Chrome 33
•Java Plug-ins
-Oracle JRE 1.7.0 update 60 for Network Advisor
-Oracle JRE 1.7.0 update 60 for Web Tools
NOTE
For higher performance, use a 64-bit JRE.
NOTE
A warning message will be displayed if the required operating system is not available.
NOTE
If the minimum system requirement is not met, you will be blocked from the configuration and an error message will be displayed.
For the website listing patch information, go to http://www.oracle.com/technetwork/java/javase/downloads/index.html.
NOTE
Network Advisor is not supported in a Network Address Translation (NAT) environment where the server and client are on different sides of the NAT Server.
Network Advisor has the following client and server system requirements:
•In the Professional edition, a single server supports a single client, which must be a local client only.
•In Professional Plus and Enterprise editions, a single server supports a maximum of 25 clients, which can be local or remote on 32-bit and 64-bit servers.
•In Professional Plus and Enterprise editions, a single server supports a maximum of 25 clients, which can be local or remote on 64-bit servers. To support more than 8 clients, you must make the following changes to your configuration:
-Increase the server memory size. You can configure the server memory size from the Options dialog box, Memory Allocations pane. For instructions, refer to the Network Advisor User Manual or online help.
-Increase the PostgreSQL database shared buffers memory allocation to 1024 MB by editing the Install_Home\data\databases\postgresql.conf file.
Brocade Network Advisor Installation and Migration Guide |
7 |
53-1003157-01 |
|
1 Downloading the software
You can download the software and documentation from the MyBrocade website.
1.Go to the MyBrocade website. http://my.brocade.com/
2.Enter your user ID and password.
If you do not already have a MyBrocade account, you can create one.
3.Select MyBrocade from the Take me to list, if necessary.
4.Click LOG IN.
5.Click downloads on the main page.
6.Select Management Software from the Download by list.
7.Click Brocade Network Advisor in the Product Name list.
8.Select the highest version number for the latest GA code.
For example, click Brocade Network Advisor 12.3.x, then click Brocade Network Advisor 12.3.0 Brocade GA.
To download the documentation, click Brocade Network Advisor 12.3.0 Manuals and then select the manual you want to download.
9.Select one of the following links to download the software:
•Network Advisor 12.3.0 GA for Windows
•Network Advisor 12.3.0 GA for Linux
You can also access the release notes and md5 Checksum from this location.
10.Read the Export Compliance, select the certification check box, and click Submit.
11.Read the Brocade End User License Agreement and click I Accept.
12.Click Save on the File Download dialog box.
13.Browse to the location where you want to save the software and click Save.
Before you install Network Advisor, make sure you meet the following requirements.
•Make sure all system requirements have been met prior to installation. For specific system requirements, refer to “System requirements” on page 1.
If you are running Professional Plus or Enterprise edition on a 32-bit machine, you must migrate to a 64-bit machine within your current release, then you can migrate to Network Advisor 12.3.
If you are running SAN with SMI Agent + IP on a 32-bit machine, you must migrate to a 64-bit machine within your current release, then you can migrate to Network Advisor 12.3.
•To avoid errors, close all instances of the application before beginning the installation or uninstallation procedures.
8 |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |
Installing the application |
1 |
For UNIX system, if you still receive error messages after closing the application, enter the following commands:
#ps -ef | grep -i “” to list the process IDs
#kill -9 “Process_ID” where Process_ID is any Management application process
•Make sure that an X Server is available for display and is configured to permit X Client applications to display from the host on which they are installing the Network Advisor server (typically, this simply requires that the systems console be present and running with a logged-in user on the X Server-based desktop session, such as KDE, GNOME, and so on).
If this is a headless unit with no console, refer to “Additional pre-installation requirements for UNIX systems (headless installation)” on page 12.
•Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value (for example, to display to the local console, export DISPLAY=:0.0, or to display to a remote system that has an X Server running, export DISPLAY=Remote_IP_address:0.0).
You may also need to consider a firewall that might block the display to the X Server, which listens by default on TCP port 6000 on the remote host.
To display to a remote system, you need to permit the remote display of the X Server by running the xhost +IP command, where IP is the IP address of the Network Advisor server host from the X-based desktop of the remote system.
•Make sure you test the DISPLAY definition by running the xterm command, from the same shell from which you run install.bin. A new X terminal window to the destination X Server display should open.
•For Linux OS with the SELinux security policy enabled, make sure you complete the following steps.
1.Disable the SELinux security policy using the setenforce 0 command.
2.Install the application (refer to “Installing the application” on page 9).
3.Enable the SELinux security policy using the setenforce 1 command.
Installing the application
Before you install the application, make sure your system meets the minimum pre-installation requirements (refer to “Pre-installation requirements” on page 8). If you are migrating data, refer to “Data Migration” on page 39.
NOTE
SAN with SMI Agent + IP is not supported on 32-bit Windows systems. For more information, refer to “Pre-migration requirements” on page 44.
NOTE
On Windows systems, you must be an Administrator with Read and Write privileges to install Network Advisor.
Brocade Network Advisor Installation and Migration Guide |
9 |
53-1003157-01 |
|
1 Installing the application
NOTE
On UNIX systems, you must be the root user to install Network Advisor.
To install the new application version, complete the following steps.
1.Choose one of the following options:
•For Windows systems, open this file:
Download_Location\Application_Name\windows\install.exe.
•For UNIX systems, complete the following steps.
a.On the Management application server, go to the following directory:
Download_Location/Application_Name/UNIX_Platform/bin
b.Type the following at the command line:
ulimit -n 2000
c.Type the following at the command line:
./install.bin
OR
sh install.bin
NOTE
On Linux systems, if you double-click the install.bin file, select Run. Do not select Run in Terminal.
The following are the list of folder permission in Linux:
•BNA_HOME - 775
•Conf/schema folder(including sub-folders) - 775
•Conf folder - 775
•Data folder - 775
•Database folder - 700
•DB folder (including sub folder) - 775
•Temp folder -775
•support folder - 777
•Other folders -774
2.Click Next on the Introduction screen.
3.Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement, and click Next.
4.Select the usual location for your system application files (for example, D:\Program Files\Application_Name or opt/Application_Name) on the Select Install Folder screen and click Next.
NOTE
Do not install to the root directory C:\ (Windows) or / (UNIX).
5.Review the displayed installation summary on the Pre-Installation Summary screen and click Install.
10 |
Brocade Network Advisor Installation and Migration Guide |
|
53-1003157-01 |