Bosch TR2500TO 5 B operation manual [de]

Montage- und Gebrauchsanleitung | Installation and operating instructions | Notice de montage et d’utilisation |
Istruzioni per l‘uso e per il montaggio | Montage- en gebruikshandleiding | Упътване за монтаж и употреба
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced
TR2500TO 5 B | TR3500TO(R) 5 T
6 720 876 005 (2018/12) DIV

Inhaltsverzeichnis

1 Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Montageanleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 Auspacken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 Produktbeschreibung . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.3 Wandmontage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.4 Wasseranschluss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.5 Erstinbetriebnahme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.5.1 Elektroanschluss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.5.2 Heizvorgang überprüfen . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.5.3 Wassertemperatur begrenzen . . . . . . . . . . . . . . . . . . . . . 4
3 Technische Daten. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4 Gebrauchsanleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1 Wassertemperatur einstellen . . . . . . . . . . . . . . . . . . . . . 4
4.2 Wassertemperatur begrenzen. . . . . . . . . . . . . . . . . . . . . 5
4.3 Ausschalten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.4 Nur Untertischgeräte TR3500TO 5 T und
TR3500TOR 5 T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.5 Reinigung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.6 Entkalken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.7 Wartung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5 Eine Störung, was tun? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6 Kundendienst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dieses Gerät ist nur für den privaten Haushalt und das häusliche Umfeld bestimmt.
• Das Gerät wie in Text und Bild beschrieben montieren und bedienen. Wir übernehmen keine Haftung für Schäden, die durch Nichtbeach­tung dieser Anleitung entstehen.
• Dieses Gerät ist für den Gebrauch bis zu einer Höhe von 2 000 m über dem Meeresspiegel bestimmt.
• Das Gerät nur in einem frostfreien Raum installieren und lagern (Restwasser).
WARNUNG:
Stromschlaggefahr! Ziehen Sie im Fehlerfall sofort den Netzstecker!
Bei einer Undichtigkeit am Gerät sofort die Kaltwasser zuleitung schließen.
Das Gerät nur von einem Fachmann anschließen und in Betrieb nehmen lassen.
Um Gefährdungen zu vermeiden, dürfen Reparaturen und War­tung nur von einem Fachmann durchgeführt werden.
• Vor der Montage die Wasserzuleitung absperren. Netzstecker nicht einstecken.
VORSICHT:
Achtung! Gerät erst vollständig mit Wasser füllen, dann Netz stecker einste-
cken, sonst löst die wieder einschaltbare Sicherheitstemperaturbe­grenzung aus.
7 Entsorgung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
• Die gesetzlichen Vorschriften sowie die Anschlussbedingungen des Elek­trizitäts-Versorgungsunternehmens und des Wasserwerkes einhalten.
• Das Gerät nur an eine vorschriftsmäßig installierte Schutzkontakt­Steckdose anschließen. Kein Verlängerungskabel verwenden.
Vor dem Öffnen des Gerätes Netzstecker ziehen.
• Das Gerät darf nicht über eine externe Schaltvorrichtung, wie bei­spielsweise eine Zeitschaltuhr, versorgt werden, um eine Gefährdung durch ein unbeabsichtigtes Rücksetzen des Schutztemperaturbe­grenzers im Störfall zu vermeiden.
• Die Anschlussleitung darf nicht an heißen Teilen anliegen. Die Isolie­rung könnte beschädigt werden.
Den Kleinspeicher nur offen (drucklos) und für eine Zapfstelle
verwenden. Der Warmwasser-Auslauf dient zum Druckausgleich und darf nur an die dafür geeignete Armatur angeschlossen wer­den (Bestell-Nr. BZ 13051, BZ 13071 oder BZ 13062 für Unter­tischgeräte oder BZ 11113 für Übertischgeräte).
• Der Auslauf der Armatur muss immer frei sein. Keine Perlatoren (Luft­sprudler) oder Brausearmaturen verwenden.
• Dieses Gerät kann von Kindern ab 8 Jahren und darüber sowie von Personen mit verringerten physischen, sensorischen oder mentalen Fähigkeiten oder Mangel an Erfahrung und Wissen benutzt werden, wenn sie beaufsichtigt oder bezüglich des sicheren Gebrauchs des Gerätes unterwiesen wurden und die daraus resultierenden Gefah­ren verstehen. Kinder dürfen nicht mit dem Gerät spielen. Reinigung und Benutzer-Wartung dürfen nicht von Kindern ohne Beaufsichti- gung durchgeführt werden.
• Kinder vom Gerät fern halten.
• Kinder beaufsichtigen, um zu verhindern, dass sie mit dem Gerät spielen.
• Das Warmwasserrohr kann heiß werden. Kinder darauf hinweisen.
• Keine Scheuermittel oder anlösende Reinigungsmittel verwenden.
• Keinen Dampfreiniger benutzen.
2
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
Montageanleitung
Die Montage- und Gebrauchsanleitung bitte sorgfältig durchlesen, danach handeln und aufbewahren!

2 Montageanleitung

2.1 Auspacken

• Das neue Gerät auf Transportschäden kontrollieren!
• Verpackung und gegebenenfalls Altgerät umweltgerecht entsorgen.
Lieferumfang (Bild 1) 1 Gerät mit Bedienblende 2 Montagebügel 3 Nur TR3500TOR 5 T:
Befestigung (2 Schrauben, 2 Dübel)
4 Schriftgut

2.2 Produktbeschreibung

Der Kleinspeicher ist für den offenen (drucklosen) Anschluss geeignet. Er erhitzt und speichert Trinkwasser bis ca. 85 °C. Mit dem Temperatur­wähler können verschiedene Temperaturstufen eingestellt werden.
Das Gerät darf nicht mit vorgewärmtem Wasser betrieben werden, sonst löst die Sicherheitstemperaturbegrenzung aus.
Das Gerät wird mit dem Netzstecker angeschlossen. Diese Montage- und Gebrauchsanleitung beschreibt verschiedene Gerä-
tetypen:
• Untertischgeräte mit zusätzlicher Tropfstoppfunktion und Druck-
stopp TR3500TO 5 T und TR3500TOR 5 T
• Übertischgeräte TR2500TO 5 B
Montagevorbereitung (Bild 1)
Vor der Montage die Wasserzuleitung absperren. Netzstecker
nicht einstecken.
• Montagebügel am Gerät abnehmen und die Halteringe
abbrechen (A).
• Anschlusskabel je nach gewünschter Länge auf der Geräte-rückseite
fixieren (B).

2.3 Wandmontage

Untertischgeräte TR3500TO 5 T und TR3500TOR 5 T (Bild 2)
• Gerät auf der Wand ausrichten und an den drei Einkerbungen (oben,
links und rechts am Gerät) die Markierungen anzeichnen (A).
• Die Markierungen mit der Wasserwaage zu einem Linienkreuz verbin-
den (B1 und B2).
• Den Montagebügel an der Einkerbung oben am Kreuzungspunkt der
gezeichneten Linien ansetzen und die Löcher anzeichnen (C).
• Löcher bohren und Dübel einsetzen (D1).
• Den Montagebügel (Einkerbung oben) mit den Schrauben an der
Wand anbringen (D2).
• Gerät in den Montagebügel einhängen (D3). Gerät tauschen (Bild 3) Bei Austausch eines alten Kleinspeichers durch dieses neue Gerät kön-
nen die vorhandenen Befestigungslöcher mit Dübeln verwendet werden. Es ist aber zu beachten, dass das neue Gerät etwa 2 cm höher ist.
Soll das neue Gerät oben bündig wie das alte Gerät sein (E1):
• Den neuen Montagebügel mit der Einkerbung nach oben an der Wand
anbringen.
Soll das neue Gerät unten bündig wie das alte Gerät sein (E2):
• Den neuen Montagebügel umdrehen und mit der Einkerbung nach
unten an der Wand anbringen.
Übertischgeräte TR2500TO 5 B (Bild 4)
• Gerät auf der Wand ausrichten und an den drei Einkerbungen
(oben, links und rechts am Gerät) die Markierungen anzeichnen (F).
• Die Markierungen mit der Wasserwaage zu einem Linienkreuz verbin-
den (G1 und G2).
• Den Montagebügel an der Einkerbung oben am Kreuzungspunkt
der gezeichneten Linien ansetzen und die Löcher anzeichnen (H).
• Löcher bohren und Dübel einsetzen (I1).
• Den Montagebügel (Einkerbung oben) mit den Schrauben an der
Wand anbringen (I2).
Gerät tauschen (Bild 5) Bei Austausch eines alten Kleinspeicher durch dieses neue Gerät können
die vorhandenen Befestigungslöcher mit Dübeln verwendet werden. Es ist aber zu beachten, dass das neue Gerät etwa 2 cm höher ist.
• Den neuen Montagebügel umdrehen und mit der Einkerbung nach
unten an der Wand anbringen (J).

2.4 Wasseranschluss

VORSICHT:
Achtung! Die vorhandene Armatur darf nicht verkalkt sein.
Gewinde nicht fetten! Info: Ersatz für beschädigte Gewindestutzen ist beim Kundendienst er-
hältlich.
Untertischgeräte TR3500TO 5 T und TR3500TOR 5 T (Bild 6)
• Bei Bedarf Armatur montieren (A1 und A2).
• Dichtung einsetzen (B1).
• Auf den axialen Sitz der Anschlussrohre in den Stutzen achten.
• Überwurfmutter gerade auf Gewinde aufsetzen und von Hand andre-
hen (B2).
• Verschraubungen festziehen (C). Gewindestutzen am Speicher mit
Schraubenschlüssel gegenhalten.
• Verschraubung nach einigen Aufheizvorgängen nachziehen.
Übertischgeräte TR2500TO 5 B (Bild 7)
• Bei Bedarf Mischbatterie montieren (D1 bis D3).
• Verbindungsrohre zur Mischbatterie mit Dichtung einsetzen (E).
Auf den axialen Sitz der Anschlussrohre in den Stutzen achten.
• Dichtungen am Verbindungsrohr einsetzen (F1).
• Gerät einhängen (G).
• Überwurfmutter (F2) gerade auf Gewinde aufsetzen und von Hand
andrehen.
• Verschraubungen festziehen (H1 und H2). Gewindestutzen am Spei­cher mit Schraubenschlüssel gegenhalten (H1).

2.5 Erstinbetriebnahme

2.5.1 Elektroanschluss

Wichtig: Netzstecker noch nicht einstecken!
• Gerät erst vollständig mit Wasser füllen, das Wasser muss aus der Ar­matur laufen.
• Danach Netzstecker einstecken.
Hinweis: Bei einem nicht mit Wasser gefüllten Gerät löst die wieder ein­schaltbare Sicherheitstemperaturbegrenzung aus!

2.5.2 Heizvorgang überprüfen

• Drehwähler auf „3“ (ca. 85 °C) drehen.
• Aufheizen überwachen, bis die Kontrolllampe nach ca. 12‒18 Minuten erlischt.
• Temperatur prüfen.
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
3
Technische Daten
VORSICHT:
Hat die Sicherheitstemperaturbegrenzung den Kleinspeicher abgeschal­tet, Netzstecker ziehen, Warmwasserhahn öffnen und ca. 4 Liter Wasser durchlaufen lassen, dann Netzstecker wieder einstecken. Das Gerät ist nun wieder betriebsbereit

2.5.3 Wassertemperatur begrenzen

Die Auslauftemperatur des Kleinspeichers kann mechanisch auf Stufe „1“ (ca. 38 °C) oder Stufe „eco“ (ca. 60 °C) begrenzt werden (siehe „Bedienung“, Seite 4).
Energiesparen
• Zum Energiesparen den Drehwähler auf „eco“ stellen.
• Bitte dem Benutzer die Montage- und Gebrauchsanleitung überge­ben und das Gerät erklären.

3 Technische Daten

Typ TR3500TO 5 T
Untertisch
Nennleistung [kW] 2,2 1,8 2,2 1,8 Nenninhalt [l] 5,0 5,0 5,0 5,0 CLICKFIX plus Montagetechnik  Druckstopp Tropfstopp  –– Mischwassermenge 40 °C
(15 °C/65 °C) / (15 °C/85 °C) Temperatur stufenlos einstellbar bis [°C] 85 85 85 85 Bereitschaftsenergieverbrauch bei 65 °C/24 h [kWh/d] 0,18 0,18 0,18 0,18 Elektroanschluss [V] 230 230 230 230 Aufheizzeit auf 60 °C
(Zulauftemperatur 12 °C) Absicherung [A] 10 10 10 10 Wasseranschluss ["] 3/8 3/8 1/2 1/2 Maximaler Durchfluss [l/min] 5 5 5 5 Kabellänge [m] 0,6 0,6 0,6 0,6 Maße (Höhe×Breite×Tiefe) [mm] 435×270×240 435×270×240 435×270×240 435×270×240 Gewicht gefüllt [kg] 7,7 7,7 7,7 7,7 Energieeffizienzklasse AAAA Lastprofil XXS XXS XXS XXS Jahresenergieverbrauch [kWh] 477 484 481 484 Täglicher Stromverbrauch [kWh] 2,260 2,340 2,310 2,340 Schallleistungspegel [dB] 15 15 15 15 Warmwasserbereitungs-Energieeffizienz [%] 37,8 36,8 37,2 36,8
[l] 9,5/14 9,5/14 9,5/14 9,5/14
[min] 8 9 8 9
TR3500TOR 5 T
TR3500TO 5 T
Untertisch
TR2500TO 5 B
Übertisch
TR2500TO 5 B
Übertisch

4 Gebrauchsanleitung

Vor dem Gebrauch des Gerätes, bitte sorgfältig diese Anleitung durchlesen und beachten!
Wichtig: Das Gerät niemals Frost aussetzen!
WARNUNG:
Stromschlaggefahr! Ziehen Sie im Fehlerfall sofort den Netzstecker!
Bei einer Undichtigkeit am Gerät sofort die Kaltwasserzuleitung schließen.
Bitte die ausführlichen Sicherheitshinweise am Anfang dieser Anlei­tung durchlesen und beachten!
Bedienung (Bild 8)
Der Kleinspeicher erhitzt und speichert Trinkwasser bis ca. 85 °C.
Hinweis: Wenn das Gerät längere Zeit nicht benutzt wurde, z. B. wäh-
4

4.1 Wassertemperatur einstellen

• Die gewünschte Auslauftemperatur stufenlos mit dem Drehwähler von 35 °C bis 85 °C einstellen.
oder
• Die gewünschte Auslauftemperatur fest einstellen (A):
Frostschutz
1 ca. 38 °C (leichte Rastung)
eco Energie sparen ca. 60 °C (leichte Rastung)
3 Heißwasser ca. 85 °C
Beim Aufheizen leuchtet die Kontrolllampe. Bei Übertischgeräten tropft etwas Ausdehnungswasser aus dem Auslauf. Bei hohen Temperaturen verkalkt das Gerät schneller.
Tipp: Um das Gerät ökonomisch zu betreiben und die Verkalkung zu re­duzieren, den Drehwähler auf „eco“ stellen.
rend des Urlaubs, das Wasser auf Stufe „3“ kurz auf heizen lassen.
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
Gebrauchsanleitung

4.2 Wassertemperatur begrenzen

Um Verbrühungen durch heißes Wasser zu vermeiden, Auslauftempera­tur begrenzen:
• Drehwähler auf „●“ stellen.
• Abdeckung des Drehwählers aufklappen.
• Zwischen „1“ = ca. 38 °C (B2) oder „eco“ = ca. 60 °C (B1) wählen.
• Abdeckung schließen.

4.3 Ausschalten

Drehwähler auf „●“ stellen (A). Die Heizung ist ausgeschaltet.

4.4 Nur Untertischgeräte TR3500TO 5 T und TR3500TOR 5 T

Tropfstopp
Die Tropfstoppfunktion verhindert, dass beim Aufheizen Ausdehnungs­wasser aus dem Wasserhahn tropft. Wird Wasser erhitzt, treten darin ge­löste Gase (Luft) aus dem Wasser aus. Je nach Menge der austretenden Gase kann daher – wenn eine hohe Temperatur eingestellt ist – Restwas­ser aus dem Armaturenauslauf gedrückt werden.
Druckstopp (Bild 9)
Das Gerät verfügt über eine Druckabschaltung. Die Druckabschaltung zeigt an, wenn die Armatur verkalkt ist (geringer oder kein Abfluss). Sie erkennt ab einem Wasserdruck über 0,25 Mpa (2,5 bar) auch, wenn das Gerät bei der Erstinstallation wasserseitig falsch installiert wurde. Die Druckabschaltung verriegelt automatisch den Wasserzulauf und ver­hindert ein Platzen des Behälters.
Hat der Druckstopp ausgelöst, erscheint oben am Gerät ein roter Stift (C1).
• Unbedingt die Störung beheben (siehe Kapitel 5„Eine Störung, was
tun?“).
• Erst nach Behebung der Störung lässt sich der rote Stift wieder leicht
eindrücken (C2). Der Wasserzulauf ist wieder frei.
• Bei wiederholtem Auslösen den Kundendienst benachrichtigen.
Wichtig: Ausfahrweg des Stifts (C1) nicht durch Gegen-stände versperren.

4.5 Reinigung

Keine Scheuermittel oder anlösende Reinigungsmittel verwenden. Keinen Dampfreiniger benutzen.
• Gerät außen mit einem milden Reinigungsmittel abwischen.
• Sieb im Strahlregler von Schmutz- und Kalkablagerungen reinigen.

4.6 Entkalken

• Auslaufrohr mit handelsüblichen Entkalkern oder Essig entkalken.
• Bei Entkalkern die Warnhinweise des Herstellers beachten. Wenn bei voll geöffneter Armatur das Wasser deutlich langsamer ausläuft,
Kleinspeicher und Armatur von einem Fachmann entkalken lassen. An­dernfalls kann der Druckstopp wegen unzulässig hohen Drucks auslösen.

4.7 Wartung

Um Gefährdungen zu vermeiden, dürfen folgende Reparaturen und War­tungsarbeiten nur von einem von uns konzessionierten Kundendienst durchgeführt werden.
• Bei allen Arbeiten das Gerät vom elektrischen Netz trennen und den Wasserzulauf absperren.
Elektrische Anschlussleitung wechseln
Bei sichtbaren Schäden am elektrischen Kabel:
• Gerät ausschalten, Netzstecker ziehen und Kundendienst benach­richtigen.
Zulaufsieb reinigen (Bild 10)
Bei zu geringem Durchfluss von Wasser und entkalktem Sieb im Wasser­hahn:
• Kundendienst benachrichtigen und Zulaufsieb (D) reinigen lassen.
Schutzleiterprüfung (Bild 11)
Bei gewerblich genutzten Geräten einmal im Jahr die elektrische Sicher­heit durch eine Elektro-Fachkraft nach DGUV Vorschrift 3 prüfen lassen:
• Gerät ausschalten und Netzstecker ziehen.
• Schutzleiterprüfung am Erdungskontakt (E) durchführen.
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
5
Eine Störung, was tun?

5 Eine Störung, was tun?

Funktioniert Ihr Gerät nicht wie gewünscht, so liegt es oft nur an einer Kleinigkeit. Bitte prüfen Sie, ob aufgrund folgender Hinweise die Störung selbst behoben werden kann. Sie vermeiden dadurch die Kosten für ei­nen unnötigen Kundendiensteinsatz.
• Bei allen Arbeiten das Gerät vom elektrischen Netz trennen und den Wasserzulauf absperren.
Störung Ursache Behebung Wer
Das Gerät startet (heizt) nicht, es fließt nur kaltes Wasser
Zu geringer Durchfluss von Wasser Das Sieb im Wasserhahn ist verstopft. Das Sieb entnehmen und reinigen oder entkalken. Kunde
Die Armatur tropft beim Aufheizen trotz Tropfstopp.
Der Druckstopp hat ausgelöst, es fließt kein Wasser mehr.
Konnte die Störung nicht behoben werden, bitte den Kundendienst anrufen.
Die Sicherung in der Hausinstallation hat ausgelöst.
Der Netzstecker ist nicht eingesteckt. Netzstecker einstecken. Kunde Die Sicherheitstemperaturbegrenzung hat
geschaltet.
Das Sieb im Kaltwasserzulauf ist verstopft. Zulaufsieb ausbauen, reinigen und wieder einbauen.
Der Wasserauslauf oder die Armatur ist ver­kalkt.
Häufiges, kurzzeitiges Zapfen oder Zapfen bei geringem Warmwasserdurchfluss.
Die Tropfstopp-Funktion ist defekt. Gerät austauschen. Fachmann Das Gerät wurde am Wasseranschluss falsch
installiert. Die Armatur ist verkalkt. Armatur entkalken, den roten Stift des Druckstopps
Der Warmwasseransc hluss-Stutzen ist ver­stopft.
Die Sicherung in der Hausinstallation prüfen. Kunde
Netzstecker ziehen, Warmwasserhahn öffnen und ca. 4 Liter Wasser durchlaufen lassen. Netzstecker ein­stecken.
Gerät spülen. Falls nötig, diese Prozedur so lange wiederholen, bis keine Partikel mehr im Sieb vorhan­den sind.
Entkalken oder neue Armatur einbauen. Fachmann
Länger zapfen, Warmwasserdurchfluss erhöhen. Kunde
Gerät richtig anschließen, den roten Stift des Druck­stopps hineindrücken.
hineindrücken. Warmwasseranschluss- Stutzen reinigen, falls nötig
den Wasseranschluss tauschen. Anschließend den roten Stift des Druckstopps hineindrücken.
Kunde
Fachmann
Fachmann
Kunde
Fachmann

6 Kundendienst

Wenn Sie den Kundendienst anfordern, geben Sie bitte die E-Nr. und die FD-Nr. Ihres Gerätes an. Sie finden die Nummern im Bereich der beiden
Wasseranschlussstutzen des Kleinspeichers.

7 Entsorgung

Dieses Gerät ist entsprechend der europäischen Richtlinie 2012/19/EU über Elektro- und Elektroni­kaltgeräte (waste electrical and elec tronic equipment – WEEE) gekennzeichnet. Die Richtlinie gibt den Rahmen für eine EU-weit gültige Rücknahme und Verwertung der Alt geräte vor. Über aktuelle Entsorgungswege bitte beim Fachhänd­ler informieren.
Änderungen vorbehalten.
6
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)

Table of Contents 1 Safety information

1 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2 Product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3 Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4 Water connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5 First start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5.1 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5.2 Checking the heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5.3 Limitation of the water temperature . . . . . . . . . . . . . . . . 9
3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Operating instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 Setting the water temperature . . . . . . . . . . . . . . . . . . . . . 9
4.2 Limitation of the water temperature . . . . . . . . . . . . . . .10
4.3 Switching off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.4 Undersink appliances only TR3500TO 5 T and
TR3500TOR 5 T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.5 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.6 Descaling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5 A fault, what to do?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
6 Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
This appliance is intended for domestic use and the household environment only.
• Install and operate the appliance as described in the text and illustrations. We do not accept liability for damage resulting from failure to heed these instructions.
• This appliance is intended for use up to an altitude of 2000 m above sea level.
• The appliance may only be installed and stored in a frost-free room (due to residual water).
WARNING:
Risk of electric shock! If an fault occurs, immediately disconnect the plug from the power
supply! Immediately shut off the cold water supply to the appliance should it leak.
The appliance may only be connected and put into operation by qualified professional.
To avoid potential sources of danger, repairs and maintenance may only be undertaken by a suitably qualified specialist.
• Shut off the water supply before connecting the appliance. Do not insert the plug into the mains socket.
CAUTION:
Caution! Fill the appliance with water first, then insert the mains plug,
otherwise the resettable safety temperature limitation will trip.

Table of Contents

7 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
8 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
• Observe the statutory regulations as well as the connection regulations of the electrical and water utility companies.
• Only connect the appliance to a correctly earthed electrical socket. Do not use extension cables.
Disconnect the power supply before opening the appliance.
• The appliance may not be powered via an external switching device such as a timer switch in order to exclude the danger of an unintentional reset of the safety temperature limitation in the event of a fault.
• The connection cable may not make contact with hot components. This can damage the insulation.
The small water heater is only suitable for use with an open
(unpressurised) and a single tap connection. The warm water outlet is used for pressure compensation and may only be connected to suitable fittings (Order No. BZ 13051, BZ 13071 or BZ 13062 for undersink appliances or BZ 11113 for oversink appliances).
• The tap outlet must always remain free. Do not use perlators (diffusers) or shower taps.
• This appliance can be used by children aged 8 years and older as well as by persons with diminished bodily, sensory or mental perception, or those who lack knowledge or experience, if they are monitored or have received instruction concerning use and comprehend the possible dangers that can result. Children may not play with the appliance. Cleaning and maintenance by the user may not be performed by unsupervised children.
• Keep children away from the appliance.
• Please monitor children to ensure that they do not play with the appliance.
• The warm water pipe may be hot. Please inform and instruct children appropriately.
• Do not use aggressive or abrasive cleaning detergents!
• Do not use a steam cleaner.
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
7
Installation instructions
Please read this installation and operating instruction manual carefully, then act accordingly! Store for future reference.

2 Installation instructions

2.1 Unpacking

• Inspect the new appliance for transport damage!
• Please dispose of the packaging, and if applicable, the old appliance in an environmentally-friendly manner.
Scope of delivery (Fig. 1) 1 Appliance with operating panel 2 Installation bracket 3 TR3500TOR 5 T only:
Mounting (2 screws, 2 wall plugs)
4 Documentation

2.2 Product description

The small water heater is only suitable for open (unpressurised) installation. It heats and stores drinking water up to approx. 85 °C. Different temperature levels can be selected with the temperature selector knob.
The appliance may not be operated with pre-heated water, as otherwise the safety temperature limitation will trip.
The appliance is connected using the mains plug. This installation and operating instruction manual describes various
appliance types:
• Undersink appliances with additional drip stop function and
pressure stop TR3500TO 5 T and TR3500TOR 5 T
• Oversink appliances TR2500TO 5 B
Preparations for installation (Fig. 1)
Shut off the water supply before connecting the appliance.
Do not insert the mains plug.
• Remove the installation bracket on the appliance and break off the
retaining rings (A).
• Fix the connection cable to the rear of the appliance to suit the
required length (B).

2.3 Wall mounting

Undersink appliances TR3500TOR 5 T and TR3500TO 5 T
(Fig. 2)
• Align the appliance on the wall and use the three indents (top, left and
right on the appliance) to apply markings (A).
• Connect the markings by a pattern of crossed lines with a spirit level
(B1 and B2).
• Place the installation bracket on top at the point of intersection of the
drawn lines and mark the position for the holes (C).
• Drill the holes and insert wall plugs (D1).
• Attach the installation bracket (notch at top) to the wall using the
screws (D2).
• Suspend the appliance in the installation bracket (D3).
Exchanging appliances (Fig. 3)
• When replacing an old small water heater with this new appliance, the
existing drill holes with wall plugs can be used. Please note that the new appliance is approx. 2 cm higher.
If the new appliance is to be flush at the top like the old appliance (E1):
• Attach the new installation bracket to the wall with the notches at
the top.
If the new appliance is to be flush at the bottom like the old appliance (E2):
• Turn the installation bracket around and attach to the wall with the notches at the bottom.
Oversink appliances TR2500TO 5 B (Fig. 4)
• Align the appliance on the wall and use the three indents (top, left and right on the appliance) to apply markings (F).
• Connect the markings to a pattern of crossed lines with a spirit level (G1 and G2).
• Place the installation bracket on top at the point of intersection of the drawn lines and mark the position for the holes (H).
• Drill the holes and insert wall plugs (I1).
• Attach the installation bracket (notch at top) to the wall using the screws (I2).
Exchanging appliances (Fig. 5) When replacing an old small water heater with this new appliance, the ex-
isting drill holes with wall plugs can be used. Please note that the new ap­pliance is approx. 2 cm higher.
• Turn the installation bracket around and attach to the wall with the notches at the bottom (J).

2.4 Water connection

CAUTION:
Caution! The existing fitting may not be covered with scaling.
Do not grease the thread!
Info: Replacement for damaged threaded nozzles available from customer service.
Undersink appliances TR3500TO 5 T and TR3500TOR 5 T (Fig. 6)
• Fit the taps if required (A1 and A2).
• Insert the seals (B1).
• Ensure the axial fit of the connection pipes in the nozzles.
• Place the union nuts on the thread and tighten them by hand (B2).
• Tighten the screw fitting (C). Counter the threaded nozzles on the warm water heater with a wrench
• After the unit has been used to heat water a few times, retighten the screw fitting.
Oversink appliances TR2500TO 5 B (Fig. 7)
• Install the mixer if required (D1 to D3).
• Insert the pipe connections to the mixer with seals (E). Ensure the axial fit of the connection pipes in the nozzles.
• Insert the seals on the pipe connection (F1).
• Suspend the appliance (G).
• Place the union nut (F2) on the thread and tighten it by hand.
• Tighten the screw fittings (H1 and H2). Counter the threaded nozzles on the warm water heater with a wrench (H1).

2.5 First start-up

2.5.1 Electrical connection

Important: Do not insert the plug into the mains socket yet.
• Fill the appliance with water first. Water must flow from the fitting.
• Only then insert the plug into the mains socket.
Note: If the appliance is not filled with water, the resettable safety temperature limitation will trip!

2.5.2 Checking the heating

• Turn the rotary selector switch to “3” (approx. 85 °C).
8
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
Technical data
• Monitor the heating process until the pilot lamp switches off after approx. 12–18 minutes.
• Check the temperature.
CAUTION:
If the safety temperature limitation has switched off the small water heater, unplug the mains plug, open the warm water tap and allow approx. 4 litres of water to flow. Then plug the mains plug back in. The appliance is ready again for operation.

2.5.3 Limitation of the water temperature

The temperature of the water leaving the tap for the small water heater can be mechanically set to stage “1” (approx. 38 °C) or stage “eco” (approx. 60 °C) (see “Operation”, page 9).
Conserving energy
• Set the rotary selector to “eco” to conserve energy.
• Hand over the installation and operating instructions to the user and explain how the appliance operates.

3 Technical data

Type TR3500TO 5 T
Undersink
Rated output [kW] 2.2 1.8 2.2 1.8 Rated capacity [l] 5.0 5.0 5.0 5.0 CLICKFIX plus installation technology  Pressure stop Drip stop  –– Mixed water quantities 40 °C
(15 °C/85 °C) / (15 °C/85 °C) Variable temperature adjustment up to [°C] 85 85 85 85 Stand-by power consumption at 65 °C/24 h [kWh/d] 0.18 0.18 0.18 0.18 Electrical connection [V] 230 230 230 230 Heat-up time to 60 °C
( temperature 12 °C) Fuse protection [A] 10 10 10 10 Water connection ["] 3/8 3/8 1/2 1/2 Maximum flow [l/min] 5 5 5 5 Cable length [m] 0.6 0.6 0.6 0.6 Dimensions (Height×Width×Depth) [mm] 435×270×240 435×270×240 435×270×240 435×270×240 Weight, filled [kg] 7.7 7.7 7.7 7.7 Energy efficiency class AAAA Load profile XXS XXS XXS XXS Annual energy consumption [kWh] 477 484 481 484 Daily energy consumption [kWh] 2.260 2.340 2.310 2.340 Sound power level [dB] 15 15 15 15 Hot water heating energy efficiency [%] 37.8 36.8 37.2 36.8
[l] 9.5/14 9.5/14 9.5/14 9.5/14
[min] 8 9 8 9
TR3500TOR 5 T
TR3500TO 5 T
Undersink
TR2500TO 5 B
Over-sink
TR2500TO 5 B
Over-sink

4 Operating instructions

Before using the appliance, please read the instructions carefully and observe them!
Important: The appliance may never be exposed to frost!
WARNING:
Risk of electric shock! If a fault occurs, immediately disconnect the plug from the power
supply! Immediately shut off the cold water supply to the appliance should it leak.
Please read and observe the detailed safety instructions at the start of these instructions!
Operation (Fig. 8)
The small water heater heats and stores drinking water up to approx. 85 °C.
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)

4.1 Setting the water temperature

• The required outlet temperature from 35 °C to 85 °C can be set with the rotary selector switch.
or:
• Set the required fixed outlet temperature (A):
Frost protection
1 Approx. 38 °C (soft lock-in)
eco Conserve energy approx. 60 °C (soft lock-in)
3 Hot water approx. 85 °C
The pilot lamp lights up during heat up. Water drips out of the tap with oversink appliances. The appliance with be covered more quickly with limescale at higher temperatures.
Tip: Set the rotary selector switch to “eco” to operate the appliance economically and to reduce the effects of limescale.
9
Operating instructions
Note: If the appliance has not been used for an extended period, e. g. during a holiday, allow the water to briefly heat up to stage “3”.

4.2 Limitation of the water temperature

Limit the outlet temperature to avoid scalding with hot water:
• Set the rotary selector switch to “●”.
• Open the cover of the rotary selector switch.
• Select between “1” = approx. 38 °C (B2) or “eco” = approx. 60 °C (B1).
• Close the cover.

4.3 Switching off

Set the rotary selector switch to “●” (A). The heating is switched off.
4.4 Undersink appliances only TR3500TO 5 T and
TR3500TOR 5 T
Drip stop
The drip stop function prevents expanding water from dripping from the tap during heat up. If water is heated, the gasses (air) dissolved in it will be released by the water. Depending on the quantity of gas released – particularly when a higher temperature is selected – it can force residual water from the tap.
Pressure stop (Fig. 9)
The appliance features pressure switch off. The pressure switch off indicates when the tap is clogged by limescale (low or no flow). When water pressure exceeds 0.25 Mpa (2.5 bar) it even detects if the appliance has been incorrectly connected with the water line during initial installation. The pressure switch off automatically shuts off the water inlet and prevents rupturing of the tank.
It the pressure stop has tripped, a red pin will appear at the top of the appliance (C1).
• The fault must be corrected (see chapter 5 “A fault, what to do?”).
• After the fault has been corrected, the red pin can be pushed back in easily (C2). The water inlet is now free.
• Please contact customer service if this occurs repeatedly.
Important: Do not block the path of the pin (C1) with objects.

4.7 Maintenance

The following repairs and maintenance may only be carried out by an authorised customer service representative to avoid potential sources of danger.
• The electrical mains supply and the water supply must be shut off before all work on the appliance.
Exchange of the electrical connection cable
When the electrical cable is visibly damaged:
• Switch off the device, unplug the mains plug and contact customer service.
Cleaning the inlet filter (Fig. 10)
When the flow of water is too low and the inlet filter in the tap is descaled:
• Contact customer service and get the inlet filter (D) cleaned.

4.5 Cleaning

Do not use aggressive or abrasive cleaning detergents! Do not use a steam cleaner.
• Clean appliance externally with a mild cleaning agent.
• Clean the dirt and lime scale deposits in the aerator filter.

4.6 Descaling

• Descale the outlet pipe with commercially available descaling agent or vinegar.
• Please observe the manufacturers warnings when descaling.
If the water flows significantly slower when the tap is fully opened, the small water heater and tap should be descaled by a specialist. Otherwise, the pressure stop may trip due to an unpermissible high pressure.
10
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
A fault, what to do?

5 A fault, what to do?

If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service personnel.
• The electrical mains supply and the water supply must be shut off
before all work on the appliance.
Fault Cause Solution Who
The appliance does not start (heat), only cold water flows.
Water flow-rate is too low. The filter in the tap is clogged. Remove the filter and either clean it or descale it. Customer
The tap drips during heat up regardless of the drip stop.
The pressure stop has tripped, water no longer flows.
If the fault could not be eliminated, please call customer service.
The fuse in the house electrical installation has tripped/blown.
The mains plug is not inserted. Insert the plug into the mains socket. Customer The safety temperature limitation has
tripped.
The filter in the cold water regulating valve is clogged.
The water outlet or the tap is clogged by limescale.
Frequent, momentary dispensing or dispensing with a low water flow.
The drip stop function is defective. Exchange the appliance. Servicing
The appliance has been incorrectly installed on the water connection.
The fitting is clogged by limescale. Descale the tap, push in the red pin of the pressure
The warm water connection nozzle is clogged.
Check the fuse in the house electrical installation. Customer
Unplug the mains plug, open the warm water tap and allow approx. 4 litres of water to flow. Insert the plug into the mains socket.
Remove, clean and reinstall the inlet filter. Circulate water through the appliance. If necessary, repeat this procedure until the filter is free of particles.
Descale or install a new fitting. Servicing
Longer dispensing, increase the flow of warm water. Customer
Connect the appliance correctly, push in the red pin of the pressure stop.
stop. Clean the warm water connection nozzle and
exchange the water connection if necessary. Then push in the red pin of the pressure stop.
Customer
Servicing expert
expert
expert Servicing
expert Customer
Servicing expert

6 Customer Service

We ask you to always provide the E-No. and the FD-No. of your appliance when calling in a customer service engineer. You will find the number near both water connection nozzles of the small water heater.

7 Disposal

This appliance is labelled in accordance with Euro­pean Directive 2012/19/EU concerning used electri­cal and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throug­hout the EU. Please ask your specialist retailer about current dispo­sal facilities.

8 Guarantee

The guarantee conditions for this appliance are as defined by our representative in the country in which it is sold. Details regarding these conditions can be obtained from the dealer, from whom the appliance was purchased, or directly from our representative in the country. Furthermore, the guarantee conditions can also be found on the Internet at the website address stated. The bill of sale or receipt must be produced when making any claims under the terms of this guarantee.
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
Subject to change without notice.
11

Table des matières

Table des matières 1 Consignes de sécurité

1 Consignes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 Instructions de montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1 Déballage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2 Description du produit. . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3 Montage mural . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.4 Raccordement de l’eau . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5 Première mise en service. . . . . . . . . . . . . . . . . . . . . . . . 13
2.5.1 Raccordement électrique . . . . . . . . . . . . . . . . . . . . . . .13
2.5.2 Vérifier le procédé de chauffe . . . . . . . . . . . . . . . . . . . . 14
2.5.3 Limitation de la température de l’eau . . . . . . . . . . . . . . 14
3 Données techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4 Notice d’utilisation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1 Réglage de la température de l’eau . . . . . . . . . . . . . . . . 15
4.2 Limitation de la température de l’eau . . . . . . . . . . . . . . 15
4.3 Mise hors marche. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.4 Uniquement pour appareils TR3500TO 5 T et
TR3500TOR 5 T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.5 Nettoyage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.6 Détartrage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.7 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.8 Service après-vente . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5 En cas de panne que faire ?. . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6 Èlimination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7 Conditions de garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Cet appareil est destiné exclusivement à une utilisation domestique et non professionnelle.
• Monter et utiliser l’appareil comme indiqué dans le texte et à l’écran. Nous n’assumons aucune garantie pour les risques susceptibles de survenir en cas de non-respect de cette notice.
• Cet appareil est destiné à une utilisation jusqu’à une hauteur maxi­male de 2 000 m au-dessus du niveau de la mer.
• Toujours installer et stocker l’appareil dans une pièce à l’abri du gel (eau résiduelle).
AVERTISSEMENT :
Danger de choc électrique ! En cas d’incident, immédiatement débrancher la fiche secteur !
En cas de fuite sur l’appareil, immédiatement couper l’alimentation en eau froide.
Ne faire raccorder et mettre en service l’appareil que par un tech­nicien spécialisé.
Les réparations et les travaux de maintenance ne doivent être effec­tués que par un technicien spécialisé afin d’éviter tous dangers.
• Couper l’arrivée d’eau avant de commencer le montage. Ne pas bran­cher la fiche secteur.
PRUDENCE :
Attention ! Tout d’abord complètement remplir l’appareil d’eau avant de bran-
cher la fiche secteur, le thermostat de sécurité pouvant être remis en marche risque autrement de se déclencher.
• Respecter les prescriptions légales, les conditions de raccordement des entreprises d’approvisionnement en électricité et en eau.
• L’appareil doit uniquement être raccordé à une prise à contacts de pro­tection installée correctement. Ne pas utiliser de câble de rallonge.
Toujours débrancher la fiche secteur avant d’ouvrir l’appareil.
• L’appareil ne doit pas être alimenté par le biais d’un dispositif de com­mutation, tel par exemple un temporisateur, afin d’éviter tous risques dus à une réinitialisation non souhaitée du thermostat de sécurité en cas d’incident.
• La conduite de raccordement ne doit pas reposer sur des pièces chaudes. L’isolation risquerait autrement d’être endommagée.
Utiliser le chauffe-eau compact uniquement à l’état ouvert
(hors pression) et pour une tireuse. La sortie d’eau chaude est uniquement destinée à l’équilibrage des pressions et elle doit uniquement être raccordée à la robinetterie adéquate (référence BZ 13051, BZ 13071 ou BZ 13062 pour appareils à monter au­dessous de l’évier ou BZ 11113 pour appareils à monter audes­sus de l’évier).
• La sortie de la robinetterie doit toujours être libre. Ne jamais utiliser d’aérateur ni de robinetterie de douche.
• Cet appareil peut être utilisé par des enfants d’au moins 8 ans ainsi que par des personnes à capacités physiques, sensorielles ou men­tales réduites ou par des personnes à expériences et savoir insuffisants, dans la mesure où ils sont surveillés ou bien qu’ils ont été informés sur l’utilisation sûre de l’appareil et qu’ils comprennent les dangers résultant d’une utilisation non conforme. Les enfants ne doivent jamais jouer avec l’appareil. Le nettoyage et la maintenance utilisateur peuvent uniquement être effectués par des enfants s’ils sont sous surveillance.
• Tenir les enfants à l’écart de l’appareil.
• Surveiller les enfants afin qu’ils ne jouent pas avec l’appareil.
• Le tuyau d’eau chaude peut devenir chaud. En avertir les enfants.
• Ne pas utiliser de détergents agressifs ou solvants.
12
Tronic 2500 TO | Tronic 3500 TO | Tronic Store Advanced – 6 720 876 005 (2018/12)
Loading...
+ 28 hidden pages