Bosch PMD 7 User Manual [de]

ςТЎϩХʉ ЌТϾϦφЍʉ ʌμВТЎϺυ
OBJ_BUCH-1913-003.book Page 1 Tuesday, July 7, 2015 10:25 AM
Robert Bosch GmbH
Power Tools Division 70764 Leinfelden-Echterdingen GERMANY
www.bosch-pt.com 2 609 141 285 (2015.07) T / 177 WEU
WEUWEU
PMD 7
de Originalbetriebsanleitung en Original instructions fr Notice originale es Manual original pt Manual original it Istruzioni originali nl Oorspronkelijke
gebruiksaanwijzing
da Original brugsanvisning sv Bruksanvisning i original no Original driftsinstruks fi Alkuperäiset ohjeet el Πρωτότυπο οδηγιών χρήσης tr Orijinal işletme talimatı ar
OBJ_BUCH-1913-003.book Page 2 Tuesday, July 7, 2015 10:09 AM
2 |
Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 4
English . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
Español. . . . . . . . . . . . . . . . . . . . . . . . . . Página 42
Português . . . . . . . . . . . . . . . . . . . . . . . . Página 56
Italiano . . . . . . . . . . . . . . . . . . . . . . . . . . Pagina 69
Nederlands . . . . . . . . . . . . . . . . . . . . . . . Pagina 82
Dansk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Side 94
Svenska . . . . . . . . . . . . . . . . . . . . . . . . . . . Sida 105
Norsk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Side 115
Suomi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sivu 126
Ελληνικά . . . . . . . . . . . . . . . . . . . . . . . . . . Σελίδα 137
Türkçe. . . . . . . . . . . . . . . . . . . . . . . . . . . . Sayfa 149
. . . . . . . . . . . . . . . . . . . 163
2 609 141 285 | (7.7.15) Bosch Power Tools
PMD 7
PMD 7
2
1
1
7
6
1
4
5
3
4
5
OBJ_BUCH-1913-003.book Page 3 Tuesday, July 7, 2015 10:09 AM
| 3
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 4 Tuesday, July 7, 2015 10:09 AM
4 | Deutsch
Deutsch
Sicherheitshinweise
Sämtliche Anweisungen sind zu lesen und zu beachten.
Wenn das Messwerkzeug nicht entsprechend den vorlie­genden Anweisungen verwendet wird, können die inte­grierten Schutzvorkehrungen im Messwerkzeug beein­trächtigt werden. BEWAHREN SIE DIESE ANWEISUNGEN GUT AUF.
Lassen Sie das Messwerkzeug von qualifiziertem Fachpersonal
und nur mit Original-Ersatzteilen reparieren. Damit wird sicherge-
stellt, dass die Sicherheit des Messwerkzeuges erhalten bleibt.
Arbeiten Sie mit dem Messwerkzeug nicht in explosionsgefährde-
ter Umgebung, in der sich brennbare Flüssigkeiten, Gase oder Stäube befinden. Im Messwerkzeug können Funken erzeugt werden,
die den Staub oder die Dämpfe entzünden.
Das Messwerkzeug kann technologisch bedingt keine hundertpro-
zentige Sicherheit garantieren. Um Gefahren auszuschließen, sichern Sie sich daher vor jedem Bohren, Sägen oder Fräsen in Wände, Decken oder Böden durch andere Informationsquellen wie Baupläne, Fotos aus der Bauphase etc. ab. Umwelteinflüsse,
wie Luftfeuchtigkeit, oder Nähe zu anderen elektrischen Geräten kön­nen die Genauigkeit des Messwerkzeuges beeinträchtigen. Beschaf­fenheit und Zustand der Wände (z.B. Nässe, metallhaltige Baustoffe, leitfähige Tapeten, Dämmstoffe, Fliesen) sowie Anzahl, Art, Größe und Lage der Objekte können die Messergebnisse verfälschen. Ungenauig­keiten können z. B. durch die Befeuchtung von Baumaterialien (vor al­lem Gips, Tapeten) durch höhere Luftfeuchtigkeit verursacht werden. Diese Einflüsse können dazu führen, dass die Signalleuchte grün leuch­tet, obwohl sich ein Objekt im Sensorbereich befindet, oder dass die Signalleuchte rot leuchtet, obwohl sich kein Objekt im Sensorbereich befindet.
Achten Sie während der Messung auf ausreichende Erdung. Bei un-
zureichender Erdung (z. B. durch isolierendes Schuhwerk oder Stehen auf einer Leiter) ist die Ortung spannungsführender Leitungen nicht möglich.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 5 Tuesday, July 7, 2015 10:09 AM
Deutsch | 5
Produkt- und Leistungsbeschreibung
Bestimmungsgemäßer Gebrauch
Das Messwerkzeug ist bestimmt zur Suche nach Eisenmetallen (z.B. Be­wehrungsstahl), nach Nichteisenmetallen (z. B. Kupferrohre) sowie spannungsführenden Leitungen in Wänden, Decken und Fußböden.
Abgebildete Komponenten
Die Nummerierung der abgebildeten Komponenten bezieht sich auf die Darstellung des Messwerkzeugs auf der Grafikseite.
1 Markierungshilfe 2 Signalleuchte 3 Ein-/Ausschalter 4 Arretierung des Batteriefachdeckels 5 Batteriefachdeckel 6 Seriennummer 7 Sensorbereich
Technische Daten
Digitales Ortungsgerät PMD 7
Sachnummer max. Erfassungstiefe*:
– Eisenmetalle – Nichteisenmetalle (Kupferrohr) – Kupferleitungen (spannungsführend) **
Kalibrierung Abschaltautomatik nach ca. Betriebstemperatur
* abhängig von Material und Größe der Objekte sowie Material und Zust and des Unter­grundes (Wände, Decken, Böden)
** geringere Erfassungstiefe bei nicht spannungsführenden Leitungen
Das Messergebnis kann hinsichtlich der Genauigkeit und Erfassungstiefe bei
ungünstiger Beschaffenheit des Untergrundes schlechter ausfallen.
Zur eindeutigen Identifizierung Ihres Messwerkzeugs dient die Seriennummer 6 auf dem Typenschild.
3 603 F81 100
70 mm 60 mm 50 mm
automatisch
10 min
0°C...+40°C
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 6 Tuesday, July 7, 2015 10:09 AM
6 | Deutsch
Digitales Ortungsgerät PMD 7
Lagertemperatur –20°C...+70 °C Relative Luftfeuchte Batterien Betriebsdauer (Alkali-Mangan-Batterien) ca.
30 ... 80 %
3 x 1,5 V LR03 (AAA)
5h
Gewicht entsprechend EPTA-Procedure 01:2014 0,15 kg
* abhängig von Material und Größe der Objekte sowie Material u nd Zustand des Unter­grundes (Wände, Decken, Böden)
** geringere Erfassungstief e bei nicht spannungsführenden Leitungen
Das Messergebnis kann hinsichtlich der Genauigkeit und Erfassungstiefe bei
ungünstiger Beschaffenheit des Untergrundes schlechter ausfallen.
Zur eindeutigen Identifizierung Ihres Messwerkzeugs dient die Seriennummer 6 auf dem Typenschild.
Konformitätserklärung
Wir erklären in alleiniger Verantwortung, dass das unter „Technische Daten“ beschriebene Produkt allen einschlägigen Bestimmungen der Richtlinien 2011/65/EU, 1999/5/EG einschließlich ihrer Änderungen entspricht und mit folgenden Normen übereinstimmt: EN 61010-1:2010-10, EN 613 26-1:2006-05, EN 301489-3:2002-08, EN 301489-1:2011-09, EN 300330-1:2010-02, EN 300330-2:2010-02.
Henk Becker Executive Vice President Engineering
Helmut Heinzelmann Head of Product Certification PT/ETM9
Robert Bosch GmbH, Power Tools Division 70764 Leinfelden-Echterdingen, GERMAN Y Leinfelden, 16.06.2015
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 7 Tuesday, July 7, 2015 10:09 AM
Deutsch | 7
Montage
Batterien einsetzen/wechseln
Für den Betrieb des Messwerkzeugs wird die Verwendung von Alkali­Mangan-Batterien empfohlen.
Zum Öffnen des Batteriefachdeckels 5 drücken Sie auf die Arretierung 4 und klappen den Batteriefachdeckel auf. Setzen Sie die Batterien ein. Achten Sie dabei auf die richtige Polung entsprechend der Darstellung auf der Innenseite des Batteriefachs.
Nehmen Sie die Batterien aus dem Messwerkzeug, wenn Sie es
längere Zeit nicht benutzen. Die Batterien können bei längerer Lage-
rung korrodieren und sich selbst entladen.
Betrieb
Inbetriebnahme
Schützen Sie das Messwerkzeug vor Nässe und direkter Sonnen-
einstrahlung.
Setzen Sie das Messwerkzeug keinen extremen Temperaturen
oder Temperaturschwankungen aus. Lassen Sie es z. B. nicht länge-
re Zeit im Auto liegen. Lassen Sie das Messwerkzeug bei größeren Temperaturschwankungen erst austemperieren, bevor Sie es in Be­trieb nehmen. Bei extremen Temperaturen oder Temperaturschwan­kungen kann die Präzision des Messwerkzeugs beeinträchtigt wer den.
Vermeiden Sie heftige Stöße oder Stürze des Messwerkzeuges. Ein-/Ausschalten
Stellen Sie vor dem Einschalten des Messwerkzeugs sicher, dass
der Sensorbereich 7 nicht feucht ist. Reiben Sie das Messwerkzeug
gegebenenfalls mit einem Tuch trocken.
Schieben Sie zum Einschalten des Messwerkzeugs den Ein-/Ausschalter 3 nach unten.
Nach einem kurzen Selbsttest ist das Messwerkzeug betriebsbereit. Die Betriebsbereitschaft wird dadurch angezeigt, dass die Signalleuchte 2 leuchtet. Leuchtet nach dem Einschalten die Signalleuchte 2 nicht auf, müssen Sie die Batterien erneuern.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 8 Tuesday, July 7, 2015 10:09 AM
8 | Deutsch
Schieben Sie zum Ausschalten des Messwerkzeugs den Ein-/Ausschalter 3 nach oben.
Erfolgt ca. 10 min lang keine Messung, dann schaltet sich das Messwerk­zeug zur Schonung der Batterien automatisch ab.
Hinweis: Hat sich das Messwerkzeug automatisch abgeschaltet, so befin­det sich der Ein-/Ausschalter 3 noch in der eingeschalteten Position. Um das Messwerkzeug wieder einzuschalten, schalten Sie es zuerst aus und dann wieder ein.
Betriebsarten
Das Messwerkzeug detektiert Objekte unterhalb des Sensorbereiches 7.
Signalleuchte Erklärung
grün kein Objekt gefunden gelb – Metallobjekt in der Nähe des Sensors
rot und Dauerton Metallobjekt im Sensorbereich gefunden rot blinkend (schnell) und
pulsierende Tonfolge
Metallobjekte suchen
Nach dem Einschalten leuchtet die Signalleuchte 2 grün. Setzen Sie das Messwerkzeug auf die zu untersuchende Oberfläche und
bewegen Sie es seitlich. – Ist im Untergrund kein Metallobjekt erkennbar, dann leuchtet die
Signalleuchte 2 weiterhin grün und es ertönt kein Signalton.
– Nähert sich das Messwerkzeug einem Metallobjekt, leuchtet die
Signalleuchte 2 zunächst gelb und geht bei Annäherung an das Metall­objekt in Rot über. Sobald die Signalleuchte rot leuchtet, wird zusätz­lich ein Signalton abgegeben, der bei weiterer Annäherung an da s Metallobjekt in der Tonhöhe ansteigt.
– Über einem Metallobjekt leuchtet die Signalleuchte 2 rot und es ertönt
ein Signalton mit maximaler Tonhöhe.
– kleines oder tief liegendes Metallobjekt
im Sensorbereich oder
– Beeinträchtigung des Sensors durch
ungünstige Wandbeschaffenheit
spannungsführende Leitung gefunden
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 9 Tuesday, July 7, 2015 10:09 AM
Deutsch | 9
Auch bei gelber Signalleuchte 2 kann sich ein Metallobjekt unter-
halb des Sensorbereichs befinden. Kleine oder tief liegende Metall-
objekte befinden sich in der Nähe des Sensors, oder die Wandbeschaf­fenheit beeinträchtigt das Messergebnis.
Beim ersten Überfahren wird die Position des Metall­objekts nur grob angezeigt. Wenn Sie das Metallobjekt mehrmals mit dem Messwerkzeug überfahren, wird die Objekterkennung immer präziser. Nach mehrmali­gem Überfahren (ohne das Messwerkzeug vom Unter­grund abzuheben) kann die Position des Metallobjek­tes genau angezeigt werden: Leuchtet die Signalleuchte 2 rot und ertönt der Signalton, liegt das
Metallobjekt unterhalb des Sensorbereichs. Wenn die Tonhöhe des Signaltons am höchsten ist, befindet sich das Metallobjekt unterhalb der Sensormitte.
Spannungsführende Leitungen suchen
Das Messwerkzeug zeigt Leitungen an, die Spannung zwischen 110 V und 240 V führen und deren Frequenz dem weit verbreiteten Standard (Wechselstrom mit 50 bzw. 60 Hz) entspricht. Andere Leitungen (Gleich­strom, höhere/niedrigere Frequenz oder Spannung) sowie nicht span­nungsführende Leitungen können nicht zuverlässig gefunden werden, sie werden aber gegebenenfalls als Metallobjekte angezeigt.
Die Suche nach spannungsführenden Leitungen erfolgt automatisch bei jeder Messung. Wird eine spannungsführende Leitung gefunden, blinkt die Signalleuchte 2 rot und es ertönt ein pulsierender Signalton in schnel­ler Tonfolge. Bewegen Sie das Messwerkzeug wiederholt über die Fläche, um die spannungsführende Leitung genauer zu lokalisieren. Nach mehr­maligem Überfahren kann die Position der spannungsführenden Leitung sehr genau angezeigt werden.
Spannungsführende Leitungen können leichter gefunden werden, wenn Stromverbraucher (z. B. Leuchten, Geräte) an der gesuchten Leitung angeschlossen und eingeschaltet werden. Schalten Sie die Stromver­braucher aus, bevor Sie in die Wand bohren, sägen oder fräsen.
Hinweis: Achten Sie stets darauf, dass Sie das Messwerkzeug ohne Handschuhe fest in der Hand halten, um eine gute Erdung zu ermöglichen. Achten Sie außerdem darauf, dass Leitern/Gerüste geerdet sein müssen . Vermeiden Sie hierzu Leitern/Gerüste, deren Stützen am Boden Kunst­stoffkappen aufweisen. Tragen Sie kein isolierendes Schuhwerk.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 10 Tuesday, July 7, 2015 10:09 AM
10 | Deutsch
Unter bestimmten Bedingungen (wie z. B. hinter Metalloberflächen, hin­ter sehr trockenen oder sehr feuchten Oberflächen) können spannungs­führende Leitungen nicht sicher gefunden werden. Leuchtet über einem größeren Bereich die Signalleuchte 2 gelb oder rot, dann schirmt das Ma­terial elektrisch ab und die Suche nach spannungsführenden Leitungen ist nicht zuverlässig.
Arbeitshinweise
Halten Sie das Messwerkzeug nicht im Bereich des Sensors fest, um die Messung nicht zu beeinflussen. Dadurch erreichen Sie genauere Mess­ergebnisse.
Objekte markieren
Sie können gefundene Objekte bei Bedarf markieren. Die Außenkanten eines Objektes können Sie durch den Wechsel der Signalleuchte 2 von gelb zu rot finden. Die Mitte des Metallobjekts können Sie anhand der Tonhöhe feststellen. Markieren Sie die gesuchte Stelle mit einem Stift an der oberen und den seitlichen Markierungshilfen 1.
Dauerblinken Grün/Gelb/Rot
Blinkt die Signalleuchte 2 abwechselnd grün, gelb und rot, auch wenn kein Metallobjekt oder kein spannungsführendes Kabel in der Nähe ist, muss das Messgerät zum Service eingeschickt werden.
Wartung und Service
Manuelle Kalibrierung
Leuchtet die Signalleuchte 2 rot ode r gelb, obwohl sich kein Metall in der Nähe des Messwerkzeugs befindet, muss das Messwerkzeug neu kali­briert werden. – Schalten Sie dazu das Messgerät mit dem Ein-/Ausschalter 3 ein. – Entnehmen Sie eine Batterie aus dem eingeschalteten Messgerät. – Schalten Sie das Messgerät mit dem Ein-/Ausschalter 3 aus, während
die Batterie entnommen ist.
– Legen Sie die Batterien wieder in das Messgerät ein. (Achten Sie auf
die Polung!)
– Entfernen Sie nun alle Objekte aus der Nähe des Messgeräts (auch
Armbanduhr oder Ring aus Metall) und halten Sie dieses in die Luft.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 11 Tuesday, July 7, 2015 10:09 AM
Deutsch | 11
– Schalten Sie das Messgerät mit dem Ein-/Ausschalter 3 ein und inner-
halb von 3 Sekunden wieder aus. Die Signalleuchte 2 des Messgeräts blinkt während der 3 Sekunden in langsamer Folge rot, um seine Be­reitschaft zur Kalibrierung anzuzeigen.
– Schalten Sie das Messgerät innerhalb von 0,5 Sekunden wieder ein.
Die Kalibrierung wird ausgelöst und dauert etwa 6 Sekunden. Die Signalleuchte 2 blinkt für 6 Sekunden in schneller Folge grün, die Kali­brierung wird durchgeführt. Danach ist das Gerät wieder betriebsbe­reit und die Signalleuchte 2 leuchtet dauerhaft grün.
Hinweis: Wird die Abfolge aus Ausschalten und Wiedereinschalten nicht eingehalten, so wird keine Kalibrierung durchgeführt . Die Signalleuchte 2 leuchtet weiterhin entweder gelb oder rot, obwohl sich kein Metall in der Nähe befindet. Wiederholen Sie in diesem Fall die Kalibrierung.
Fehler – Ursachen und Abhilfe
Ursache Abhilfe
Signalleuchte 2 leuchtet nicht.
Messwerkzeug nicht eingeschaltet
Messwerkzeug hat sich selbst ausge­schaltet.
Keine Batterien oder Batterien falsch einge­legt
Batterien leer oder Akkus eingelegt
* Beachten Sie deshalb vor dem Bohren, Sägen oder Fräsen in Wänden, Decken oder Böden auch andere Informationsquellen (z. B. Baupläne).
Schalten Sie das Messwerkzeug ein.
Schalten Sie das Messwerkzeug aus und dann wieder ein.
Legen Sie Batterien ein. Achten Sie auf die Polung.
Erneuern Sie die Batterien. Verwenden Sie keine Akkus.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 12 Tuesday, July 7, 2015 10:09 AM
12 | Deutsch
Ursache Abhilfe
Signalleuchte 2 leuchtet gelb oder rot, obwohl kein Metall in der Nähe ist (Warnung vor Metallobjekten).
Umgebungstempera­tur zu hoch/zu niedrig
Starker Temperatur­wechsel
Autokalibrierung nicht
Verwenden Sie das Messwerkzeug nur im spezi­fizierten Temperaturbereich von 0 °C –40 ° C.
Warten Sie, bis das Messwerkzeug die Um­gebungstemperatur angenommen hat.
Führen Sie eine manuelle Kalibrierung durch.
erfolgreich
Signalleuchte 2 leuchtet gelb oder rot über großem Messbereich auf der Wand (Warnung vor Metallobjekten).
Viele, eng zusammen­liegende Metall­objekte
Achten Sie auf die Tonhöhe des Signaltons, um zwischen einzelnen Metallobjekten zu unter­scheiden. Zu eng zusammenliegende Metallob­jekte können nicht getrennt detektiert werden. *
Metallhaltige Bau­stoffe oder Beweh­rungsstahl in Beton
Massive Metallobjekte auf der Rückseite der
Bei metallischen Baustoffen (z.B. alukaschierte Dämmstoffe, Wärmeleitbleche) ist eine zuver­lässige Detektion nicht möglich.*
Bei massiven Metallobjekten (z. B. Heizkörpern) ist eine zuverlässige Detektion nicht möglich.*
Wand Autokalibrierung nicht
Führen Sie eine manuelle Kalibrierung durch.
erfolgreich Signalleuchte 2 blinkt rot über großem Messbereich auf der Wand
(Warnung vor spannungsführendem Kabel). Unzureichende
Erdung der Wand
Berühren Sie mit Ihrer freien Hand die Wand im Abstand von 20– 30 cm vom Messwerkzeug, um die Wand zu erden.
* Beachten Sie deshalb vor dem Bohren, Sägen oder Fräsen in Wänden, Decken oder Böden auch andere Informationsquellen (z. B. Baupläne).
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 13 Tuesday, July 7, 2015 10:09 AM
Deutsch | 13
Ursache Abhilfe
Spannungsführendes Kabel wird nicht gefunden.
Keine/untypische Spannung auf dem Kabel
Geben Sie Spannung auf das Kabel, z. B. indem Sie zugeordnete Lichtschalter einschalten. Die Detektion von Kabeln mit Wechselspannungen außerhalb des Bereichs 110 –240 V, 50 –60 Hz ist nicht zuverlässig möglich.*
Kabel liegt zu tief. Die Erfassungstiefe ist vom Baumaterial ab-
hängig und kann geringer sein als die maximale Erfassungstiefe.*
Kabel verläuft in ge­erdetem Metallrohr.
Messwerkzeug nicht geerdet
Verwenden Sie das Messwerkzeug, um das Metallrohr zu finden.
Fassen Sie das Messwerkzeug ohne Hand­schuhe fest an. Stehen Sie nicht auf isolierenden Leitern oder Gerüsten. Tragen Sie kein isolieren­des Schuhwerk.
Abschirmendes Baumaterial oder zu niedrige/zu hohe Luftfeuchtigkeit
Bei metallischen, zu trockenen oder zu feuchten Baustoffen (z. B. bei zu niedriger oder zu hoher Luftfeuchtigkeit) ist eine zuverlässige Detektion nicht möglich. *
Metallobjekt wird nicht gefunden.
Metallobjekt liegt zu tief.
Die Erfassungstiefe ist vom Baumaterial ab­hängig und kann geringer sein als die maximale Erfassungstiefe.*
Metallobjekt ist zu klein.
Die Erfassungstiefe ist vom Objekt abhängig und kann geringer sein als die maximale Erfassungstiefe.*
Unkoordiniertes Blinken in den Farben Grün, Gelb, Rot
Störung durch elektrische oder magnetische Felder
* Beachten Sie deshalb vor dem Bohren, Sägen oder Fräsen in Wänden, Decken oder Böden auch andere Informationsquellen (z. B. Baupläne).
Halten Sie Abstand von Geräten, die starke elektrische oder magnetische Felder aus­strahlen (z. B. Computer, Schaltnetzteile).
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 14 Tuesday, July 7, 2015 10:09 AM
14 | Deutsch
Ursache Abhilfe
Messergebnisse ungenau/unplausibel
Störende Metall­objekte im Bereich des Sensors
Entfernen Sie alle störenden Metallobjekte (z.B. Uhr, Armband, Ring etc.) aus dem Sensorbe­reich. Fassen Sie das Messwerkzeug nicht in der Nähe des Sensors an.
Autokalibrierung
Führen Sie eine manuelle Kalibrierung durch.
nicht erfolgreich Dauerblinken grün/gelb/rot,
obwohl kein Me tall oder kein spannungsführendes Kabel in der Nähe ist. Messwerkzeug defekt Schicken Sie das Messwerkzeug zum Service
ein.
* Beachten Sie deshalb vor dem Bohren, Sägen oder Fräsen in Wänden, Decken oder Böden auch andere Informationsquellen (z. B. Baupläne).
Wartung und Reinigung
Wischen Sie Verschmutzungen mit einem trockenen, weichen Tuch ab. Verwenden Sie keine Reinigungs- oder Lösemittel.
Um die Messfunktion nicht zu beeinflussen, dürfen im Sensorbereich 7 auf der Vorder- und Rückseite des Messwerkzeugs keine Aufkleber oder Schilder, insbesondere keine Schilder aus Metall, angebracht werden.
Kundendienst und Anwendungsberatung
Der Kundendienst beantwortet Ihre Fragen zu Reparatur und Wartung Ihres Produkts sowie zu Ersatzteilen. Explosionszeichnungen und Infor­mationen zu Ersatzteilen finden Sie auch unter:
www.bosch-pt.com
Das Bosch-Anwendungsberatungs-Team hilft Ihnen gerne bei Fragen zu unseren Produkten und deren Zubehör.
www.bosch-do-it.de, das Internetportal für Heimwerker und Garten­freunde.
www.1-2-do.com
In der Heimwerker-Community 1-2-do.com können Sie Produkttester werden, Ideen sammeln oder sich mit anderen Heimwerkern austau­schen. www.diy-academy.eu, das komplette Service-Angebot der DIY Academy.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 15 Tuesday, July 7, 2015 10:09 AM
Deutsch | 15
Geben Sie bei allen Rückfragen und Ersatzteilbestellungen bitte unbe­dingt die 10-stellige Sachnummer laut Typenschild des Produkts an.
Deutschland
Robert Bosch GmbH Servicezentrum Elektrowerkzeuge Zur Luhne 2 37589 Kalefeld – Willershausen Unter www.bosch-pt.de können Sie online Ersatzteile bestellen oder Reparaturen anmelden. Kundendienst: Tel.: (0711) 40040480 Fax: (0711) 40040481 E-Mail: Servicezentrum.Elektrowerkzeuge@de.bosch.com Anwendungsberatung: Tel.: (0711) 40040480 Fax: (0711) 40040482 E-Mail: kundenberatung.ew@de.bosch.com
Österreich
Unter www.bosch-pt.at können Sie online Ersatzteile bestellen. Tel.: (01) 797222010 Fax: (01) 797222011 E-Mail: service.elektrowerkzeuge@at.bosch.com
Schweiz
Unter www.bosch-pt.com/ch/de können Sie online Ersatzteile bestellen. Tel.: (044) 8471511 Fax: (044) 8471551 E-Mail: Aftersales.Service@de.bosch.com
Luxemburg
Tel.: +32 2 588 0589 Fax: +32 2 588 0595 E-Mail: outillage.gereedschap@be.bosch.com
Entsorgung
Messwerkzeuge, Zubehör und Verpackungen sollen einer umweltgerech­ten Wiederverwertung zugeführt werden.
Werfen Sie Messwerkzeuge und Akkus/Batterien nicht in den Hausmüll!
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 16 Tuesday, July 7, 2015 10:09 AM
16 | English
Nur für EU-Länder:
Gemäß der europäischen Richtlinie 2012/19/EU müssen nicht mehr gebrauchsfähige Messwerkzeuge und gemäß der europäischen Richtlinie 2006/66/EG müssen defekte oder verbrauchte Akkus/Batterien ge­trennt gesammelt und einer umweltgerechten Wieder­verwendung zugeführt werden.
Nicht mehr gebrauchsfähige Akkus/Batterien können direkt abgegeben werden bei:
Deutschland
Recyclingzentrum Elektrowerkzeuge Osteroder Landstraße 3 37589 Kalefeld
Schweiz
Batrec AG 3752 Wimmis BE
Änderungen vorbehalten.
English
Safety Notes
Read and observe all instructions. The integrated pro-
tections in the measuring tool may be compromised if the measuring tool is not used in accordance with the instruc­tions provided. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Have the measuring tool repaired only through qualified special-
ists using original spare parts. This ensures that the safety of the
measuring tool is maintained.
Do not operate the measuring tool in explosive environments,
such as in the presence of flammable liquids, gases or dusts.
Sparks can be created in the measuring tool which may ignite the dust or fumes.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 17 Tuesday, July 7, 2015 10:09 AM
English | 17
The measuring tool may not be 100 % accurate for technological
reasons. For this reason and to eliminate hazards, familiarise yourself with the area using other sources of information, such as building plans and photographs taken during construction, etc. before carrying out any drilling, sawing or milling work on walls, ceilings or floors. The accuracy of the measuring tool may be affected
by environmental influences, such the level of humidity or there being other electronic devices nearby. The structure and condition of the walls (e.g. damp, building materials containing metal, electrically con­ductive wallpaper, insulating materials, tiles) and the number, type, size and position of the objects may distort the measurement results. Inaccurate readings may be caused, for example, b y the building mate­rials (especially plaster and tiles) being made damp through high humidity. These influences may result in the indicator LED lighting up green despite there being an object within range of the sensor, or in the indi­cator LED lighting up red despite there not being an object within range of the sensor.
Make sure that you are properly earthed when taking measure-
ments. If you are not properly earthed (e.g. by wearing insulating foot-
wear or by standing on a ladder), it will not be possible to locate live cables.
Product Description and Specifications
Intended Use
The measuring tool is intended for the detection of ferrous metals (e. g. re­inforced steel), non-ferrous metals (e. g. copper pipes) as well as “live” wires/conductors in walls, ceilings and floors.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 18 Tuesday, July 7, 2015 10:09 AM
18 | English
Product Features
The numbering of the product features shown refers to the illustration of the measuring tool on the graphic page.
1 Marking aid 2 Signal LED 3 On/Off switch 4 Latch of battery lid 5 Battery lid 6 Serial number 7 Sensor area
Technical Data
Digital Detector PMD 7
Article number Maximum scanning depth *:
– Ferrous metals – Non-ferrous metals (copper pipe) –Copper conductors (live)**
Calibration Automatic switch-off after approx. Operating temperature Storage temperature Relative humidity Batteries Operating lifetime (alkali-manganese batteries)
approx. 5h Weight according to EPTA-Procedure 01:2014
* depending on material and size of the objects as well as mate rial and condition of the base material (walls, ceilings, floors)
** less scanning depth for wires/conductors that are not “live”
In terms of accuracy and scanning depth, the measurement result can be
inferior in case of unfavourable surface quality of the base material.
The measuring tool can be clearly identified with the serial number 6 on the type plate.
3 603 F81 100
70 mm 60 mm 50 mm
automatic
10 min
0°C...+40°C
–20°C...+70 °C
30 ... 80 %
3 x 1.5 V LR03 (AAA)
0.15 kg
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 19 Tuesday, July 7, 2015 10:09 AM
English | 19
Declaration of Conformity
We declare under our sole responsibility that the product described under “Technical Data” conforms with all the relevant provisions of the Directives 2011/65/EU and 1999/5/EC, including amendments, and meets the following standards: EN 61010-1:2010-10, EN 6132 6-1:2006-05, EN 301489-3:2002-08, EN 301489-1:2011-09, EN 300330-1:2010-02, EN 300330-2:2010-02.
Henk Becker Executive Vice President Engineering
Robert Bosch GmbH, Power Tools Division 70764 Leinfelden-Echterdingen, GER MANY Leinfelden, 16.06.2015
Helmut Heinzelmann Head of Product Certification PT/ETM9
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the operation of the measuring tool.
To open the battery lid 5, press on the latch 4 and fold the battery lid up. Insert the batteries. When inserting, pay attention to the correct polarity according to the representation on the inside of the battery compartment.
Remove the batteries from the measuring tool when not using it
for extended periods. When storing for extended periods, the
batteries can corrode and self-discharge.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 20 Tuesday, July 7, 2015 10:09 AM
20 | English
Operation
Initial Operation
Protect the measuring tool against moisture and direct sun light.Do not subject the measuring tool to extreme temperatures or var-
iations in temperature. As an example, do not leave it in vehicles for a long time. In case of large variations in temperature, allow the meas­uring tool to adjust to the ambient temperature before putting it into operation. In case of extreme temperatures or variations in tempera­ture, the accuracy of the measuring tool can be impaired.
Avoid heavy impact to or falling down of the measuring tool. Switching On and Off
Before switching the measuring tool on, make sure that the sensor
area 7 is not moist. If required, dry the measuring tool using a soft
cloth.
To switch on the measuring tool, slide the On/Off switch 3 downwards.
After a short self-test, the tool is ready for use. The readiness of use is indicated when the signal LED 2 illuminates. If the signal LED 2 fails to illuminate after switching on the tool, you must replace the batteries.
To switch off the measuring tool, slide the On/Off switch 3 upwards.
When no measurements are carried out for approx. 10 minutes, the measuring tool switches off automatically in order to extend the service life of the batteries.
Note: The on/off switch 3 will remain in the “on” position when the measuring tool switches itself off automatically. To switch the measuring tool back on, switch it off first before switching it on again.
Operating Modes
The measuring tool detects objects below the sensor area 7.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 21 Tuesday, July 7, 2015 10:09 AM
English | 21
Signal LED Explanation
green no object detected yellow – metal object in the vicinity of the sensor
– small or low-lying metal object within
the sensor area or
– impairment of the sensor due to
unfavourable wall material
red and continuous tone metal object detected in the sensor area red flashing (fast) and
“live” wire/conductor detected
intermittent sound
Detecting Metal Objects
After switching on, the signal LED 2 lights up green. Position the measuring tool on/against the surface being detected and
move it sideways. – If no metal object is visible in the base material, then the signal LED 2
continues to illuminate green and no signal tone sounds.
– When the measuring tool comes closer to a metal object, the signal LED
2 first lights up yellow and changes to red the closer it comes to the met­al object. As soon as the signal LED lights up red, a signal tone is also emitted, the pitch of which rises the closer it comes to the metal object.
– Over a metal object, the signal LED 2 illuminates red and a signal tone
is emitted at maximum pitch.
Even with a yellow signal LED 2, a metal object may be located be-
low the sensor area. Small or low-lying metal objects are located in
the vicinity of the sensor or the wall m aterial impairs the measurement results.
After moving over the surface the first time, the posi­tion of the metal object is only roughly indicated. If you move the measuring tool over the metal object several times, the object detection will become increasingly precise. After moving over the metal object several times (without lif ting the measuring tool from the base material), its position can be indicated very accurate­ly: if the signal LED 2 illuminates red and the signal
tone sounds, the metal object is below the sensor area. When the pitch of the signal tone is highest, the metal object is located below the centre of the sensor.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 22 Tuesday, July 7, 2015 10:09 AM
22 | English
Scanning for “Live” Wires
The measuring tool indicates wires, which carry voltage between 110 V and 240 V and a frequency corresponding to the widely used standard (AC with 50 or 60 Hz). Other wires (carrying DC, higher/lower frequency or voltage) as well as non-“live” wires/conductors cannot be found re­liably, but are possibly indicated as metal objects.
The detection for “live” wires/conductors takes place automatically with every measurement. When a “live” wire/conductor is detected, the signal LED 2 flashes red and an intermittent signal tone sounds with rapid tone sequence. Move the measuring tool repeatedly over the surface to locate the “live” wire/conductor more precisely. After moving over the surface several times, the position of the “live” wire/conductor can be indicated very accurately.
It is easier to find live cables if electricity consumers (e.g. lights, appliances) are connected to the cable being searched for and are switched on. Switch on electricity consumers before drilling, sawing or milling into the wall.
Note: Always ensure that you hold the measuring tool firmly without gloves to enable a good grounding. Also ensure that ladders/scaffolding must be grounded. Avoid ladders/scaffolding whose supports have plastic caps underneath them. Do not wear insulating footwear.
It may not be possible to find live cables in certain conditions (e.g. behind metal surfaces, behind surfaces that are very dry or very damp). If the in­dicator LED 2 lights up yellow or red over a large area, the material is elec­trically shielded and you will not be able to find live cables accurately.
Working Advice
To avoid affecting the measurement, do not hold the measuring tool with­in range of the sensor. This will enable you to obtain more accurate measurement results.
Marking Objects
Detected objects can be marked as required. The outer edges of an objec t are indicated by the colour change of the signal LED 2 from yellow to red. The centre of the metal object can be determined by the pitch. Using a pen, mark the sought after location at th e top and the side marker aids 1.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 23 Tuesday, July 7, 2015 10:09 AM
English | 23
Continuous Flashing Green/Yellow/Red
If the signal LED 2 flashes alternately green, yellow and red, even when no met al o bjec t or no “l ive ” cab le i s in t he v icin ity , the meas uri ng de vic e mu st be sent in for service.
Maintenance and Service
Manual Calibration
If the signal LED 2 illuminates red or yellow, even when no metal is in the vicinity of the measuring tool, the tool must be recalibrated. – To do this, switch the measuring device on using the On/Off switch 3. – Remove a battery from the switched on measuring device. – While the battery is removed, switch the measuring device off using
the On/Off switch 3.
– Reinsert the batteries into the measuring device (pay attention to the
polarity!).
– Now remove all objects in the vicinity of the measuring device (includ-
ing wrist watches or rings of metal) and hold the measuring tool up in the air.
– Switch the measuring device on using the On/Off switch 3 and off again
within 3 seconds. The signal LED 2 of the measuring device will flash red in slow succession during the 3 seconds to indicate that it is ready to calibrate.
– Switch the measuring device back on within 0.5 seconds. The calibra-
tion is initiated and takes about 6 seconds. The signal LED 2 will flash green for 6 seconds in quick succession, the calibration is being per­formed. Now the device is once more ready for operation and the signal LED 2 illuminates solid green.
Note: If the sequence of switching off then on again is not followed, no calibration is performed. The signal LED 2 remains either yellow or red, even though no metal is located within the vicinity. In this case, repeat the calibration.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 24 Tuesday, July 7, 2015 10:09 AM
24 | English
Troubleshooting – Causes and Corrective Measures
Cause Corrective Measure
Signal LED 2 does not illuminate.
Measuring tool is not switched on
Measuring tool has switched itself off
Batteries have not been inserted or been inserted incorrectly
Flat or rechargeable batteries inserted
Signal LED 2 illuminates yellow or red, even though no metal is located within the vicinity (warning of metal objects).
Ambient temperature is too high/too low
Severe temperature change
Auto calibration not successful
Signal LED 2 lights yellow or red over large measuring area on the wall (warning of metal objects).
Many, closely spaced metal objects
Building materials containing metal or reinforcing steel in the concrete
Solid metal objects on the back of the wall
Auto calibration not successful
* Therefore, please also observe other information sources (e.g. construction plans) before drilling, sawing or routing into walls, ceilings or floors.
Switch the measuring tool on.
Switch the measuring tool off and then on again.
Insert batteries. Pay attention to the polarity.
Replace batteries. Do not use rechargeable batteries.
Only use the measuring tool within the specific temperature range of 0 ° C– 40 ° C.
Wait until the measuring tool acclimates to the ambient temperature.
Perform a manual calibration.
Pay attention to the pitch of the signal sound to differentiate between individual metal objects. Metal objects that are too closely spaced, cannot be detected separately.*
A reliable detection is not possible with metallic building materials (e.g. foil-laminated insulation materials, heat sinks). *
Detection will not be accurate in the presence of solid metal objects (e.g. radiators). *
Perform a manual calibration.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 25 Tuesday, July 7, 2015 10:09 AM
English | 25
Cause Corrective Measure
Signal LED 2 flashes red over a large measuring area on the wall
(warning of “live” cables). Improper grounding of
the wall
With your free hand, touch the wall at a distance of 20 –30 cm from the measuring tool to ground the wall.
“Live” cable is not found. No/atypical voltage on
the cable
Add voltage to the cable, for example by turning on light switches assigned to it. The detection of cables with AC voltages outside of the range 110 –240 V, 50 – 60 Hz is not reliably possible.*
Cable is located too deep.
The scanning depth is dependent on the building material and may be less than the maximum scanning depth. *
Cable runs in
Use the measuring tool to locate the metal pipe.
grounded metal pipe. Measuring tool is not
grounded.
Hold the measuring tool firmly without gloves. Do not stand on insulating ladders or scaffolding. Do not wear insulating footwear.
Shielding building material or humidity too low/too high
Detection will not be accurate in the presence of metallic building materials or building materials that are too dry or too damp (e.g. if the humidity is too low or too high). *
Metal object is not located. Metal object is located
too deep.
The scanning depth is dependent on the building material and may be less than the maximum scanning depth. *
Metal object is too small.
The scanning depth is dependent on the building material and may be less than the maximum scanning depth. *
Uncoordinated flashing in colours green, yellow, red
Interference caused by electric or magnetic fields
* Therefore, please also observe other information sources (e.g. construction plans) before drilling, sawing or routing into walls, ceilings or floors.
Keep your distance from devices emitting strong electric or magnetic fields (e. g. computers, switch mode power supplies).
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 26 Tuesday, July 7, 2015 10:09 AM
26 | English
Cause Corrective Measure
Measurement results inaccurate/implausible
Interfering metal objects in the area of the sensor
Remove all interfering metal objects (e.g. watches, bracelets, rings, etc.) from within range of the sensor. Do not hold the measuring tool close to the sensor.
Auto calibration not
Perform a manual calibration.
successful Continuous flashing green/yellow/red,
even when no metal or “live” cable is in the vicinity. Measuring tool is
Send the measuring tool in for service.
defective.
* Therefore, please also observe other information sources (e.g. construction plans) before drilling, sawing or routing into walls, ceilings or floors.
Maintenance and Cleaning
Wipe away debris or contamination with a dry, soft cloth. Do not use cleaning agents or solvents.
In order not to affect the measuring function, decals/stickers or n ame plates, especially metal ones, may not be attached in the sensor area 7 on the front or back side of the measuring tool.
After-sales Service and Application Service
Our after-sales service responds to your questions concerning mainte­nance and repair of your product as well as spare parts. Exploded views and information on spare parts can also be found under:
www.bosch-pt.com
Bosch’s application service team will gladly answer questions concerning our products and their accessories.
In all correspondence and spare parts orders, please always include the 10-digit article number given on the nameplate of the product.
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 27 Tuesday, July 7, 2015 10:09 AM
English | 27
Great Britain
Robert Bosch Ltd. (B.S.C.) P.O. Box 98 Broadwater Park North Orbital Road Denham Uxbridge UB 9 5HJ At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a product in need of servicing or repair. Tel. Service: (0344) 7360109 E-Mail: boschservicecentre@bosch.com
Ireland
Origo Ltd. Unit 23 Magna Drive Magna Business Park City West Dublin 24 Tel. Service: (01) 4666700 Fax: (01) 4666888
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd. Power Tools Locked Bag 66 Clayton South VIC 3169 Customer Contact Center Inside Australia: Phone: (01300) 307044 Fax: (01300) 307045 Inside New Zealand: Phone: (0800) 543353 Fax: (0800) 428570 Outside AU and NZ: Phone: +61 3 95415555 www.bosch.com.au
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 28 Tuesday, July 7, 2015 10:09 AM
28 | English
Republic of South Africa Customer service
Hotline: (011) 6519600
Gauteng – BSC Service Centre
35 Roper Street, New Centre Johannesburg Tel.: (011) 4939375 Fax: (011) 4930126 E-Mail: bsctools@icon.co.za
KZN – BSC Service Centre
Unit E, Almar Centre 143 Crompton Street Pinetown Tel.: (031) 7012120 Fax: (031) 7012446 E-Mail: bsc.dur@za.bosch.com
Western Cape – BSC Service Centre
Democracy Way, Prosperity Park Milnerton Tel.: (021) 5512577 Fax: (021) 5513223 E-Mail: bsc@zsd.co.za
Bosch Headquarters
Midrand, Gauteng Tel.: (011) 6519600 Fax: (011) 6519880 E-Mail: rbsa-hq.pts@za.bosch.com
Disposal
Measuring tools, accessories and packaging should be sorted for environ­mental-friendly recycling.
Do not dispose of measuring tools and batteries/rechargeable batteries into household waste!
2 609 141 285 | (7.7.15) Bosch Power Tools
OBJ_BUCH-1913-003.book Page 29 Tuesday, July 7, 2015 10:09 AM
Français | 29
Only for EC countries:
According to the European Guideline 2012/19/EU, measuring tools that are no longer usable, and according to the European Guideline 2006/66/EC, defective or used battery packs/batteries, must be collected sepa­rately and disposed of in an environmentally correct manner.
Batteries no longer suitable for use can be directly returned at:
Great Britain
Robert Bosch Ltd. (B.S.C.) P.O. Box 98 Broadwater Park North Orbital Road Denham Uxbridge UB 9 5HJ At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a product in need of servicing or repair. Tel. Service: (0344) 7360109 E-Mail: boschservicecentre@bosch.com
Subject to change without notice.
Français
Avertissements de sécurité
Prière de lire et de respecter l’ensemble des instruc­tions. Au cas où l’appareil de mesure n’est pas utilisé
conformément aux présentes instructions, les dispositifs de protection intégrés risquent de ne pas fonctionner correctement. BIEN CONSERVER LES PRÉSENTES INSTRUCTIONS.
Ne faire réparer l’appareil de mesure que par une personne quali-
fiée et seulement avec des pièces de rechange d’origine. Ceci per-
met d’assurer la sécurité de l’appareil de mesure.
Bosch Power Tools 2 609 141 285 | (7.7.15)
OBJ_BUCH-1913-003.book Page 30 Tuesday, July 7, 2015 10:09 AM
30 | Français
Ne pas faire fonctionner les appareils de mesure en atmosphère
explosive, par exemple en présence de liquides inflammables, de gaz ou de poussières. L’appa reil de mesure produit des étincelles qui
peuvent enflammer les poussières ou les vapeurs.
Du f ait de sa co ncept ion, l’app areil de me sure n e peu t pas g arant ir
une sécurité absolue. Pour exclure tout danger, consultez d’autres sources d’information (plans de construction, photos prises en cours de chantier, etc.) avant d’entreprendre des travaux de per­çage, sciage ou fraisage dans un mur. Les conditions environnantes
(humidité de l’air, etc.) ou la présence à proximité d’autres appareils électriques risquent d’altérer la précision de l’appareil de mesure. La consistance et l’état des murs (humidité, matériaux métalliques, pa­piers peints conducteurs, isolants, carrelages, etc.) ainsi que le nombre, la nature, la taille et la position des objets enfuis risquent de fausser les résultats de mesure. L’humidité des murs (tout particulière­ment des plâtres et des papiers peints) consécutive à un fort taux d’humidité de l’air ambiant est également source d’imprécision. Les différents facteurs d’influence cités peuvent avoir comme consé­quence l’allumage en vert du voyant de signalisation alors qu’il y a un objet dans la zo ne de détection ou l’allumage en rouge du voyant alors qu’il n’y a aucun objet dans la zone de détection.
Veillez lors de la mesure à une mise à la terre suffisante. En cas de
mauvaise mise à la terre (p. ex. port de chaussures isolantes ou réalisa­tio n de la me sur e sur un e scab eau ou un e éc hell e), une l oca lisa tio n des câbles électriques sous tension n’est pas possible.
Description et performances du produit
Utilisation conforme
L’appareil de mesure est destiné à la détection de métaux ferreux (par ex. fers d’armature), de métaux non ferreux (par ex. tuyaux de cuivre) et de câbles électriques sous tension dans les murs, les plafonds et les sols.
2 609 141 285 | (7.7.15) Bosch Power Tools
Loading...
+ 146 hidden pages