Bosch EasyControl CT200 Installation And Operating Instructions Manual

6720884199 (2018/01) en
Installation and operating instructions
Remotely operated controller
EasyControl
CT200
Table of contents
2
Table of contents 1 Safety instructions
1.1 Explanation of symbols
Information symbol
Important information is placed between 2 lines and marked with an i-symbol in a square.
Additional symbols
Tab le 1
Please read this instruction carefully before use.
1.2 Safety instructions
This temperature controller is used to control a heat source in your dwelling.
• Do not disassemble the temperature controller under any circumstances.
• Avoid high temperatures, moisture and dusty environments.
• In order to prevent a short circuit or damage to th e controller: Do not use any liquids or cleaning agents when cleaning.
• Switch off the mains voltage of the heat source before installing.
2 Environmental protection/disposal
Environmental protection is a fundamental corporate strategy of the Bosch Group. The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed. We use the best possible technology and materials for protecting the environment taking account of economic considerations.
Packaging
Where packaging is concerned, we participate in country-specific recycling processes that ensure optimum recycling. All of our packaging materials are environmentally compatible and can be recycled .
Used electrical and electronic appliances
Electrical or electronic devices that are no longer serviceable must be collected separately and sent for environm entally c ompatible recycling ( in accorda nce with the European Waste Electrical and Electronic Equipment Directive).
To dispose of old electrical or electronic devices, you should use the return and collection systems put in place in the country concerned.
Batteries must not be disposed together with your household waste. Used batteries must be disposed of in local collection systems.
1 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Environmental protection/disposal . . . . . . . . . . . . . . . . . . . . . 2
3 Product information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.1 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.3 Warranty conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.4 Declaration of Conformity (Europe) . . . . . . . . . . . . . . . . 3
3.5 FCC Statement (USA) . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.6 IC Statement (Canada) . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.7 Data privacy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.8 Data connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.9 Proximity sensor and touch screen. . . . . . . . . . . . . . . . . 4
4 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1 Prior to installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.2 Determining the installation location . . . . . . . . . . . . . . . 4
4.3 Fitting the wall plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.4 Connecting to the heat source. . . . . . . . . . . . . . . . . . . . . 5
4.5 Installing (deinstalling) the controller . . . . . . . . . . . . . . . 5
5 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.1 Powering up EasyControl. . . . . . . . . . . . . . . . . . . . . . . . . 5
5.2 Software update. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.3 Operation of the touch screen. . . . . . . . . . . . . . . . . . . . . 5
5.4 Connecting with Wi-Fi network . . . . . . . . . . . . . . . . . . . . 6
5.5 Entering the Wi-Fi network password . . . . . . . . . . . . . . . 6
5.6 EasyControl app. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.7 Electronic thermostatically controlled radiator
valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6 Operating the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.1 Start screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.2 Symbol background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.3 Tab pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.4 Temperature setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.5 Manual operation or time program . . . . . . . . . . . . . . . . . 8
6.6 Away setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.7 DHW heating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.8 Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.9 New network password . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8 Maintenance and faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8.1 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
8.2 Faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
9 ErP Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
10 List of used Open Source Components . . . . . . . . . . . . . . . . . . 10
11 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
11.1 Apache License 2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
11.2 BSD (Three Clause License) . . . . . . . . . . . . . . . . . . . . . 11
11.3 MIT License. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
11.4 Texas Instruments-Software License Agreement. . . . . 12
12 Technical terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Symbol Meaning
a step in an action sequence a reference to a related part in the document
a list entry – a list entry (second level)
Product information
3
3 Product information
3.1 Scope of delivery
Fig. 1 Scope of delivery
[1] EasyControl CT 200 [2] Quick Install Guide [3] Screw with rawl plug 2 × [4] Wall plate
3.2 Accessories
The following accessories are available:
• Electronic thermostatically controlled radiator valve
• EasyControl adaptor
• EasyControl app (free of charge)
3.3 Warranty conditions
A manufacturer's warranty of 2 years is provided for the EasyControl.
3.4 Declaration of Conformity (Europe)
This product complies with RED 2014/53/EU, the European Directives and the supplementary national requirements. Its conformity is demonstrated by the CE designation.
The Declaration of Conformity can be downloaded on the internet (www.bosch-easycontrol.com/manual) or can be requested from the manufacturer. You will find the relevant web address on the back cover of this document.
3.5 FCC Statement (USA)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
• To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral devices).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
3.6 IC Statement (Canada)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
3.7 Data privacy
Information about data protection can be found on the EasyControl site under Data protection.
1)
3.8 Data connection
▶ The EasyControl supports open Wi-Fi connections and Wi-Fi
connections encrypted with WEP 128, WPA and WPA2 protocols. WPA2 is the safest protocol and is therefore preferred.
▶ “Hidden” networks are not supported. ▶ The EasyControl takes over the time setting of the Bosch server. If
there is no connection to the server, the EasyControl can only be put into operation in manual operation.
▶ All costs for creating an Internet connection and a smart device are to
be borne by the user.
▶ The type of connected heat source determines, which functions can
be used. Consult the EasyControl site to gain an overview of which functions are available for which heat source.
1)
0010018147-001
2x
E
as
yCo
ntr
o
l
6
7
2
0
xx
x
xx
x
(
20
1
8
/
0
x
)
Q
u
ick
in
st
a
ll
gu
id
e
1
2
3
4
1) See the back of this document for the web address.
Assembly
4
3.9 Proximity sensor and touch screen
Fig. 2 Proximity sensor and touch screen
[1] Proximity sensor [2] Touch screen
A proximity sensor [1] detects a presence in front of the touch screen [2] and lights up. If nothing more is detected for a short period of time, the touch screen automatically switches off. If the detection lasts for longer than 5 minutes, the touch screen automatically switches off. After this, the touch screen can only be activated again by touching it.
▶ If required, clean the touch screen with a clean, dry cloth.
4 Assembly
4.1 Prior to installation
▶ Prior to installation, check that EasyControl can be combined with
the heat source.
On the EasyControl site there is a list of possible combinations with or without the operation of the EasyControl.
1)
Minimum requirements for installation: ▶ 2-wire cable to a heat source, which is suitable for use with
EasyControl.
▶ Broadband internet access via Wi-Fi 802.11 b/g (2.4 GHz) for use
with the app and internet functions.
4.2 Determining the installation location
A reference room is a room (for example the living room), where the temperature, which is representative of the whole dwelling, is measured, and where most time is spent.
If weather-compensated control is used, it is not necessary to locate the controller in the reference room.
▶ I nstall the controller on an interna l wall in th e reference roo m. Ensure
that there is sufficient clearance around the controller.
Fig. 3 Installation location for controller, clearance
Fig. 4 Installation location for controller, condition
4.3 Fitting the wall plate
When replacing a controller of the 100 to 400 series with EasyControl, the existing wall plate can continue to be used ( section 4.5).
This wall plate can be fastened directly to the wall, for example at the location of the previous controller.
▶ Pull the mains plug of the heat source from the socket.
When fitting to a recessed wall box, ensure that the room temperature measurement can not be impaired by any draughts. If required, stuff the recessed wall box with thermal insulation material.
▶ Connect the lead (EMS-BUS connection of the heat source) to the
terminals on the wall plate. The wires can be connected in any order.
Fig. 5 Connecting the wall plate
1) See the back of this document for the web address.
0010018148-001
1
2
0010018149-001
1,2 - 1,9 m
≥ 0,75 m
≥ 1 m
≥ 0,6 m
0010018150-001
≥ 1 m
≥ 0,4 m
≥ 0,6 m
0010018151-002
EMS
l 100 m
EMS BUS
Loading...