1 | Overview
The B440 provides IP communication over the Verizon 3G cellular network by directly connecting
the module to the control panel. The control panel can be confi gured for Personal Notifi cation
using the B440 module and a cellular network.
The B440 module requires active cellular service to communicate. Bosch Cellular devices are
shipped pre-activated with Bosch Cellular service.
1
2
3
4
1
5
Figure 1.1: Module overview
Callout ― Description
1 ― Module handle and support leg
2 ― LEDs
3 ―
Threaded female SMA antenna connector
4 ― Plug-in module retention clip opening
5 ― PCB metal contacts
2 | Install or remove the module
CAUTION!
Remove all power (AC and battery) before making any connections. Failure to do so
might result in personal injury and/or equipment damage.
2.1 | Install the antenna
Installing the antenna:
1. Place the magnetic antenna on top of
the enclosure, or vertically on another
metal surface.
2. Route the antenna cable through a
knock-out.
3. Connect the antenna cable to the
module.
4. Secure the antenna cable to the inside
of the enclosure.
Figure 2.2: Wiring the antenna
Callout ― Description
1 ― Antenna routed though any knock-out
2 ― Antenna cable connected to the
module
2.2 | Install the module
The control panel communicates with and
provides power to the module through the
plug-in connection. Proper installation results
in the necessary electrical and mechanical
connection.
Installing the module:
1. With the module facing the control
panel as shown in Figure 2.2, insert
the support leg into the support hole
labeled X.
2. Align the PCB metal contacts with the
on-board connector.
3. Push the module into place. The
retention clip snaps closed and secures
the module in place.
Figure 2.2: Module installation
Callout ― Description
1 ― Support leg inserted into the control
panel support hole labeled X
2 ― PCB metal contacts resting on the
on-board connector
3 ― Plug-in module retention clip
2.3 | Remove the module
To remove an installed module, hold the plugin module retention clip open with one hand
while grasping the top corners of the module
support handle with your other hand. Pull
the module out.
3 | Diagnostic LED
descriptions
At power up, all B440 LEDs activate
for several seconds, indicating proper
insertion. The Signal LEDs then turn off
until the module registers on the cellular
network. Registering a new module
might take up to 2 min.
Check the LED display to ensure a
good signal strength level, and adjust
the antenna location as required. The
signal strength LEDs momentarily turn
off to indicate the module has measured
and updated the signal strength status.
Refer to Table 3.1.
Flash pattern Function
Red Indicates an
Yellow Indicates a marginal
Green (1 light) Indicates a good
Green (2 lights) Indicates a very good
Table 3.1: Signal strength LEDs description
unacceptable signal
strength level.
signal strength level.
signal strength level.
signal strength level.
Flash pattern Function
Flashes once
every 1 sec (blue)
Normal State: Indicates
normal operation.
5 | Certifi cations
Region Agency Certifi cation
US FCC FCC, Part 15 Class B Radiated/Conducted Emissions
Verizon Open Development Certifi ed
UL UL 365 - Police Station Connected Burglar Alarm Units and
Systems
UL 636 - Holdup Alarm Units and Systems
UL 864 - Control Units and Accessories for Fire Alarm Systems
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar-Alarm System Units
UL 1076 - Proprietary Burglar Alarm Units and Systems
UL 1610 - Central-Station Burglar-Alarm Units
Conettix Plug-in Cellular
Communicator
B440
ON Steady (blue)
Communication Error
State: Indicates the
module is unable to
communicate on the
cellular network.
OFF Steady
LED Trouble State:
Module is not powered,
or some other trouble
condition prohibits
the module from
controlling the STATUS
LED. (Check for proper
installation.)
Table 3.2: STATUS LED descriptions
4 | Confi guration
Use Remote Programming Software (RPS) or
an SDI2 keypad to program the control panel
to use the module for communication.
For programming parameter descriptions,
options, and defaults refer to RPS Help or the
Program Entry Guide for your control panel.
For Bosch Cellular account status and
management, use RPS or the online service
portal (go to http://www.conettix.com/
Cellular.aspx and click on the Cellular Portal
Login link).
6 | Specifi cations
Dimensions 2 in x 3.68 in x 0.60 in (50 mm x 93.5 mm x 15.25 mm)
Voltage (operating) 12 V nominal
Standby current 35 mA
Alarm current 100 mA
Operating temperature 0°C to +49°C (+32°F to +120°F)
Relative humidity Up to to 93% non-condensing
Cellular compatibility EVDO rev A
CDMA2000
1xRTT
Included antenna – Magnetic base omni-directional antenna
– 2.5 m (8.2 ft) cable with SMA connector
Compatibility Control Panels
B9512G/B9512G-E/B8512G/B8512G-E
B5512/B5512E, B4512/B4512E, B3512/B3512E
The B440 is compatible with most Bosch control panels when
used with a B450 Conettix Plug-in Communicator Interface.
Refer to the Conettix Plug-in Communicator Interface (B450)
Installation and Operation Guide for complete control panel
compatibility listings.
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is protected by
copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security Systems, Inc.
website at
http://www.boschsecurity.com/datecodes/.