Intrusion Alarm Systems | DS937 Panoramic Detector
DS937 Panoramic Detector
www.boschsecurity.com
u Low profile design
u 360° up to 14 m (50 ft) coverage
u Easy installation
The ceiling mount DS937 PIR Detector provides panoramic coverage (360° x 14 m [50 ft]). Its low profile design provides a recessed-mount look, even when surface mounted. The wiring and programming options can be accessed without having to remove the detector from the ceiling. With a 14 m (50 ft) diameter coverage pattern, it is an ideal ceiling mounting choice for applications that require spot or 360° detection.
Functions
Alarm Display
Red LED (on/off selectable) lights on detection for 2.0 ±0.5 sec.
Alarm Memory
Memory Input allows LED to latch if detector alarms during alarm period. First-to-alarm signal allows indication of first detector to alarm when multiple units are used on the same loop.
u AC or DC operating voltage
Installation/configuration notes
Certifications and approvals
Region Certification
Europe CE EN 61000-6-3:2007/A1:2011; EN
50130-4:2011
USA UL ANSR: Intrusion Detection Units
(UL639)
Top View Standard coverage varies by mounting height. 360° x 14 m (50 ft) diameter when mounted at 3.7 m (12 ft).
0 m
0 ft
7 m
25 ft
25 ft
7 m
0 m
0 ft
3 m
10 ft
2 | DS937 Panoramic Detector
Side View Standard coverage varies by mounting height. 360° x 14 m (50 ft) diameter when mounted at 3.7 m (12 ft).
Technical specifications
Detection
Zones: A total of 50 detection zones
Speed: 0.2 m/s ~ 5.0 m/s (0.5 ft/s ~ 15 ft/s)
Pulse Count Selectability:
1, 2, 3, or 4 pulses
Enclosure Design
Dimensions: 12.7 cm x 3.8 cm
Weight: 176 g (6.2 oz)
(5 in. x 1.5 in.)
Environmental Considerations
Humidity: 0 to 95% humidity non-condensing
Operating Temperature:
-10°C to +49°C (+14°F to +120°F)
For UL Listed Applications, 0°C to +49°C (+32°F to +120°F)
Mounting
Height Range: 2.4 m to 3.7 m (8 ft to 12 ft) recommended
Outputs
Relay: Dry Contact (NC) rated at 30 VDC, 500 mA, 10 W
Tamper Switch: Integral NC, cover-activated
maximum
Power Requirements
Current Draw: 17 mA maximum at 12 VDC
Voltage: 9 VDC to 30 VDC, 7.5 VAC to 24 VAC
Warm-Up Period: 35 ±3 seconds
Ordering information
DS937 Panoramic Detector
Provides low profile design, PIR, 360° x 14 m (50 ft) panoramic coverage.
Order number DS937