Bosch AMAX panel 2000 ICP-AMAX-P, AMAX panel 2000 EN ICP-AMAX-P-EN User Manual

AMAX panel 2000 / AMAX panel 2000 EN
ICP-AMAX-P / ICP-AMAX-P-EN
en User Guide
AMAX panel 2000 / AMAX panel 2000 EN Table of Contents | en 3
Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12
Table of Contents
2.2.2 Disarming with wireless control Key 9
3 Faults or Tamper conditions 10
3.1 System fault or tamper analysis Mode 10
4 Walk test mode 12
5 Event Memory Recall mode 13
6 Reset the Control Panel 14
7 Bypassing 15
7.1 Bypassing Zones 15
7.2 Bypassing Faults and Tamper conditions (Except Zone Tampers) 15
8Codes 16
8.1 Enable / Disable the installer codes 16
8.2 Change individual code 16
9 Keypad alarm operation commands 17
9.1 Duress alarm 17
9.2 Keypad panic alarm 17
9.3 Keypad fire alarm 17
9.4 Keypad medical alarm 17
10 Domestic Dialing 18
4 en | Introduction AMAX panel 2000 / AMAX panel 2000 EN
F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH
1 Introduction
Quick keypad operation instructions
Table 1.1 Quick keypad operation instructions
ICP-AMAX - LED8-8 Zone LED Keypad ICP-AMAX-LCD8 - 8 Zone LCD Keypad
Arming
AWAY arm [code] + [#] / [#] (quick arming) STAY arm [code] + [*] / [*] (quick arming)
Disarming
Disarm [code] + [#]
Other Commands
Fault and Tamper Analysis
[code] + [2] [#]
Walk test [code] + [4] [#] Event recall [code] + [5] [#] System Reset [code] + [6] [#] Bypassing zones [code] + [9] [#] [zone] + [*] [#] Bypassing Faults
and Tamper conditions
[code] + [97] [#]
Enable/Disable Installer code
Enable = [code] + [98] [#] Disable = [code] + [98] [*]
Change individual code
[code] + [99] [#] [newcode] [#]
Alarm Commands
Duress alarm [code] + [0] [#] Emergency
alarm
Simultaneously press and hold [1] and [3] or [*] and [#]
Fire alarm Simultaneously press and hold [4] and [6] Medical alarm Simultaneously press and hold [7] and [9] Default user code = 2580
AMAX panel 2000 / AMAX panel 2000 EN Introduction | en 5
Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12
Keypad Indicators
Table 1.2 Keypad Indicators
LCD keypad indicator icons
LED keypad indicator lights
Status Definition
Zone (1-8) on Zone is triggered.
off Zone is normal. Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Zone was alarmed or is in alarm status.
Slow flash (1 second lights on/1 second lights off)
Zone is manually bypassed or interior Zone is in STAY ARM mode.
AWAY on System is armed in AWAY mode.
off System not armed in AWAY mode. Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code function mode. STAY indicator flashes simultaneously.
STAY on System is armed in STAY mode.
off System not armed in STAY mode. Slow flash (1 second lights on/1
second lights off)
Exit time.
Fast flash (0.25 seconds lights on/
0.25 seconds lights off)
Programming mode or Code function mode. AWAY indicator flashes simultaneously. When bypass function is performed, the STAY indicator only flashes.
MAINS on AC main power is normal.
Slow flash (1 second lights on/1 second lights off)
AC main power supply failed.
FAULTS on System fault or Tamper condition
is present. off System is in normal status. Flashes System fault or Tamper condition
must be acknowledged. on System is disarmed.
1 2 3 ….
6 en | Introduction AMAX panel 2000 / AMAX panel 2000 EN
F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH
Keypad sounds
Table 1.3 Keypad sounds
Sound indicator Definition
One short beep A keypad button has been pressed. One single one-
second beep
The requested operation is refused. Incorrect operation signal.
Two short beeps The system accepted the code. The system executed the requested
function.
One short beep per second
In walk test mode.
One short beep every two seconds
Exit time started.
Continued sound
Last 10s on exit time – Keypad fault/tamper sound (fault/tamper to be acknowledged) – Keypad alarm sound
Continuous 0.5 second beep, stops 0.5 seconds
Entry delay time (until alarm ends or system is disarmed).
Loading...