To ensure proper and safe operation, the appliance must be properly installed and grounded by a
qualifi ed technician. DO NOT attempt to adjust,
repair, service, or replace any part of your appliance unless it is specifi cally recommended in
this manual. All other servicing should be referred
to a qualifi ed servicer. Have the installer show you
the location of the gas shutoff valve and how to
shut it off in an emergency. A certifi ed technician
is required for any adjustments or conversions to
Natural or LP gas.
FOR THE INSTALLER: Before installing the Bertazzoni appliance, please read these instructions
carefully. This appliance shall be installed in accordance with the manufacturer’s installation instructions. Leave these instructions with the owner, who should save them for local inspector’s
use and for future reference. DO NOT remove
permanently affi xed labels, warnings, or plates
from product. This may void the warranty.
Installation must conform with all local codes. In
the absence of codes:
• United States: installation must conform with
the National Fuel Gas Code ANSI Z223.1
INFPA54
• Massachusetts: All gas products must be
installed by a “Massachusetts” licensed plumber or gasfi tter. A “T” type handle manual valve
must be installed in the gas supply line to the
appliance.
• Canada: Installation must be in accordance
with the current CAN/CGA B149.1 & 2 Gas
Installation codes and/or local codes. Electrical installation must be in accordance with the
current CSA C22.1 Canadian Electrical Codes
Part 1 and/or local codes.
This range is NOT designed for installation in
manufactured (mobile) homes or recreational
park trailers.
DO NOT install this range outdoors.
Warning!
To avoid risk of property damage, personal injury
or death; follow information in this manual exactly to prevent a fi re or explosion. DO NOT store
or use gasoline or other fl ammable vapors and
liquids nearbythis or any appliance.
WHAT TO DO IF YOU SMELL GAS: Do not
light any appliance. Do not touch any electrical switch. Do not use any phone in your building. Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s
instructions. If you cannot reach your gas
supplier, call the fi re department.
NOTE: Installation and service must be performed by a qualifi ed installer, service agency or the
gas supplier.
DANGER!!! ELECTRIC SHOCK HAZARD!!!
To avoid risk of electrical shock, personal injury
or death, verify that the appliance has been properly grounded in accordance with local codes or
in absence of codes, with the National Electrical
Code (NEC). ANSI/NFPA 70- latest edition.
DANGER!!! GAS LEAK HAZARD!!!
To avoid risk of personal injury or death, leak-testing of the appliance must be conducted according to the manufacturer’s instructions. Before
placing appliance in operation, always check for
gas leaks with water and soap solution.
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS.
This appliance must be properly grounded.
Grounding reduces the risk of electric shock by
providing a safe pathway for electric current in the
event of a short circuit.
Warning!
To avoid risk of property damage, personal
injury or death; follow information in this manual exactly to prevent a fi re or explosion.
4
Warning - tipping hazard
Children and adults can tip over the range if it has
not been secured.This may lead to fatal injuries.
To reduce the risk of the appliance tipping, it must
be secured and connected using the anti-tip device according to the installation instructions.
Re-engage the anti-tip device if the range is
moved. Do not operate the range without te
anti-tipdevice in place and engaged. Do not
use the range if the anti-tip device has not been
properly installed and engaged. See installation
instructions for details.
Failure to observe the information contained in the installation instructions can
lead to serious or fatal injuries for children and adults.
/ Warnings
5
/ Data rating label / Before installation
DATA RATING LABEL
The data rating label shows the model and serial
number of the range. It is located under the con-
trol panel and in the last page of this manual.
BEFORE INSTALLATION
• This appliance shall only be installed by an au-
thorized professional.
• This appliance shall be installed in accordance
with the manufacturer’s installation instructions.
• This appliance must be installed in accordance
with the norms & standards of the country whe-
re it will be installed.
• The installation of this appliance must conform
to local codes and ordinances. In the absence
of local codes, Installations must conforms to
American National Standards, National Fuel
Gas Code ANSI Z223.1 – latest edition/NFPA
54 or B149.1.
• The appliance, when installed, must be electri-
cally grounded in accordance with local codes
or, in the absence of local codes, with the Natio-
nal Electrical Code, ANSI/NFPA 70.
If local codes permit, a fl exible metal appliance
connection conduit with the new AGA or CGA certifi ed design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to the
gas supply line. Do not bend or damage the fl exible connector when moving the appliance.
This appliance must be used with the pressure
regulator provided.
The regulator shall be properly installed in order to
be accessible when the appliance is installed in its
fi nal location. The pressure regulator must be set
for the type of gas to be used. The pressure regulator has ½” female pipe thread. The appropriate
fi tting must be determined based on the size of
your gas supply line, the fl exible metal connector
and the shutoff valve.
The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 PSI (13,8” w.c. or 3,5 kPa).
A manual valve shall be installed in an accessible
location in the gas line external to the appliance
for the purpose of turning on or shutting off gas to
the appliance.
Type of gas
This range can be used with Natural or LP/Propane gas. The range is shipped from the factory
for use with the gas indicated on the rating label
positioned on the lower face of the control panel
and in the last page of this manual. A step by step
conversion procedure is also included in this manual and in each conversion kit.
Gas pressure
The maximum inlet gas supply pressure incoming
to the gas appliance pressure regulator is 1/2 PSI
(13,8’’ w.c. or 3,5 kPa). The minimum gas supply
pressure for checking the regulator setting shall
be at least 1“ w.c. (249 Pa) above the inlet specifi ed manifold pressure to the appliance; this operating pressure is 4” w.c. (1.00 kPa) for Natural
Gas and 11” w.c. (2.75 kPa) for LP Gas.
Room ventilation
An exhaust fan may be used with the appliance;
in each case it shall be installed in conformity
with the appropriate national and local standards.
Exhaust hood operation may aff ect other vented
appliances; in each case it shall be installed in
conformity with the appropriate national and local
standards.
Warning
This appliance should not be installed with a
ventilation system that directs air in a downward
direction toward the range. This type of ventilation system may cause ignition and combustion
problems with the appliance resulting in personal
injury, property damage, or unintended operation.
Ventilating systems that direct the air upwards do
not have any restriction.
Do not use aerosol sprays in the vicinity of
this appliance while it is in operation.
All opening and holes in the wall and fl oor, back
and under the appliance shall be sealed before
installation of the appliance.
6
VENTILATION PREPARATION
/ Ventilation preparation / Specifi cations
This range will best perform when installed with
Bertazzoni exhaust hoods. These hoods have
been designed to work in conjunction with the
Bertazzoni range and have the same fi nish for a
perfect look.
Before installation of the exhaust hood, consult local or regional building and installation codes for
additional specifi c clearance requirements.
Refer to the range hood installation instructions
provided by the manufacturer for additional information.
Select Hood and Blower Models:
• For wall installations, the hood should be equal
or larger width than the range. Where space
permits, a hood larger than the range may be
desirable for improved ventilation performance.
• For island installations, the hood width should
overhang the range by a minimum of 3” (76
mm) on each side.
Hood Placement:
• For best removal of smoke and odors, the
lower edge of the hood should be installed
between 25 1/2” (65 cm) and 31 1/2” (80 cm)
above the range cooking surface.
• If the hood contains any combustible materials
(i.e. a wood covering), it must be installed at a
minimum of 36” (914 mm) above the cooking
surface.
Consider Make-Up Air:
Due to the high volume of ventilation air, a source of outside replacement air is recommended.
This is particularly important for tightly sealed
and insulated homes. A qualifi ed heating and
ventilating contractor should be consulted.
SPECIFICATIONS
A
/8
27''
A
MAX
1/2
37''
30’’ 36’’ 48’’
5/8
1''
5''
/
''
2''
A
/16
25''
15/16
1''
32''
7/8
23''
1/2
- 5''
3/4
5/8
1''
1/8
1''
3''
7/16
3''
3 ''
7/16
2''
11/16
7
/ Specifi cations
s
Burner
urnerInjector
Injector
diam.[mm]
Auxiliary
0.90
0.54
Semi-rapid
1.18
0.70
Rapid
1.55
0.92
Dual burner
0.80+2.10
0.50+1.20
MAIN oven
30’’/48’’
Broiler
30’’/48’’
Oven 36’’
1.85
1.10
1.40
0.98
2.00
1.16
Broiler 36’’
1.60
0.98
AUX. Oven
48’’
1.25
0.75
Gas
as
Type
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
NG
LP (Propane)
900
900
1,500
1,500
2,500
2,500
1,300
1,300
3,500
3,500
only max
only max
4,100
4,100
only max
only max
2,400
2,400
[W]
264
264
439
439
732
732
381
381
1,025
1,025
only max
only max
1,201
1,201
only max
only max
703
703
By-pass
-pas
diam.[mm]
Regulated
0.29
Regulated
0.36
Regulated
0.47
Regulated
0.34/0.65
Regulated
0.60
No by-pass
No by-pass
Regulated
0.62
No by-pass
No by-pass
Regulated
0.49
See use and care manual for the layout of the surface burners of your range
8
CLEARENCE DIMENSIONS
/ Clearence dimensions
Installation adjacent to kitchen cabinets
This range may be installed directly adjacent to
existing countertop high cabinets (36” or 91.5 cm
from the fl oor).
For the best look, the worktop should be level with
the cabinet countertop. This can be accomplished
by raising the unit using the adjustment spindles
on the legs.
ATTENTION: the range CANNOT be installed directly adjacent to kitchen walls, tall cabinets, tall
appliances, or other vertical surfaces above 36”
(91.4 cm) high. The minimum side clearance in
such cases is 6” (15.2 cm).
Wall cabinets with minimum side clearance must
be installed 18” (45.7 cm) above the countertop
with countertop height between 35 ½” (90.2 cm)
and 37 ¼” (94.6 cm). The maximum depth of wall
cabinets above the range shall be 13” (33.0 cm).
Cabinet
30’’ (76,2 cm)
A
36’’ (91,5 cm) hood with combustible materials
B
13’’ (33,0 cm)
C
18’’ (45,7 cm)
D
35’’ 1/2(90,2 cm) / 37”
E
F
6’ (15,2 cm)
G
12”(30,50 cm)
1/4
(94,6 cm)
Metal hood
A
30’’ (76,2 cm)
B
25 1/2’’(65 cm) and 31 1/2’’ (80 cm)
C
13’’ (33,0 cm)
D
18’’ (45,7 cm)
E
35’’ 1/2(90,2 cm) / 37”
F
6’ (15,2 cm)
G
12”(30,50 cm)
H
1” 9/16(4 cm)
Shaded area behind range indicates minimum
clearance to combustible surfaces, combustible
materials cannot be located within this area.
12” (305 mm) min. to combustible surface with
Flush Island Trim
1/4
(94,6 cm)
For Flush Island installations, counter surface
should have a cantilever edge meeting the back
section of the Flush Island Trim accessory.
As defi ned in the “National Fuel Gas Code” (ANSI
Z223.1, Current Edition).
Clearances from non-combustible materials are
not part of the ANSI Z21.1
scope and are not certifi ed by CSA. Clearances of
less than 12” (305 mm)
must be approved by the local codes and/or by
the local authority having jurisdiction.
A properly-grounded horizontally- mounted electrical receptacle should be installed no higher than
3” (7.6 cm) above the fl oor, no less than 2” (5 cm)
and no more than 8” (20,3 cm) from the left side
(facing product).
Check all local code requirements.
GAS
An agency-approved, properly-sized manual
shut-off valve should be installed no higher than
3” (7.6 cm) above the fl oor and no less than 2” (5
cm) and no more than 8” (20.3 cm) from the right
side (facing product).
To connect gas between shut-off valve and regulator, use agency-approved, properly sized fl exible
or rigid pipe. Check all local code requirements.
Warning!
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit breaker box or fuse box before installing the appliance.
Provide appropriate ground for the appliance.
Use copper conductors only.
Failure to follow these instructions could result in serious injury or death.
This unit is manufactured for a polarized, grounded 120 volt/60 Hz, 16 amp system.
Electric power consumption is about 300 W for
30” and 36”, 1200W for 48”
The minimum of 102 VAC is required for proper
operation of gas ignition systems.
The circuit must be grounded and properly polarized.
The unit is equipped with a SJT power cord and
a NEMA 5-15P plug. In case of replacement, the
power cord shall be replaced with one of the same
type, size and length.
installation area for the connection
Electrical grounding
This appliance is equipped with a three-prong
plug for your protection against shock hazard and
should be plugged directly into a properly grounded socket. Do not cut or remove the grounding
prong from this plug.
Caution
Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
10
/ Wiring diagram
WIRING DIAGRAM
The electric wiring diagrams and schematics are attached behind the range, and should not be removed
except by a service technician, then replaced after service.
J12 J11J10 J9 J8 J7
J1 J2 J3 J4 J5 J6
IGN
3071063
MAGNET UNITS &
TERMOCOUPLES
J13
T-Z
v
MV
MVT
COLOURS
Simb. Descr iption
a
ILF
rRed
grGreen (earth)
vViolet
aOrange
nB lack (line)
biWhit e (neutral)
a
LF
IGN
n
bi
n
G
gv
r
KI
n
bi
n
bi
Comm.2+0
1
P
2
P
3
P
4
P
COM
m
1
2
3
4
gr
INV
r
LF
r
gv
MV
gv
bi
GV
n
N
L
M
LEGENDA
Simb.Description
IGN Ignition Mic ro switches
INV Fan Oven Interlock
COM Oven Function Selector
GSpark Generator
ILF Oven lamp switch
KITermal switch
LFOven lam p
MTerminal Bloc k
MV Fan motor
MVT Cooling fan motor
T-ZT-ze ro
r
bi
n
3071064
n
RGR
MAGNET UNITS &
TERMOCOUPLES
r
GE
S
2
1
TSS
bi
bi
r
IGN
right
gv
IGN
left
J12 J11J10 J9 J8 J7
J13
T-Z
J1 J2 J3 J4 J5 J6
v
bi
MVT
left
KI
a
n
n
ILF
right
LF
right
a
MVT
right
b
IGN
G
Simb. Descrip tion
rRed
gr Green (earth)
bBlue
v Violet
aOrange
n Blac k (line)
bi White (neutral)
n
r
COLOURS
gv
a
MV
MV
bi
INV
n
Comm.2+0
1
1
P
2
2
bi
P
3
3
4
P
4
P
COM
ILF
a
left
bi
LF
left
a
gv
r
r
LEGENDA
GV
M
Simb.Description
IGN Ignition Micro s witches
INV Fan Oven Interlock
COM Oven Functi on Selector
G Spark Generator
GE Griddle Thermostat
ILF Oven lamp switch
KI Termal switch
LF Oven lamp
M Terminal Bloc k
MV Fan motor
MVT Cooling fan motor
RGR Griddl e element
TSS Safety Thermostat
T-Z T-zero
gv
bi
n
N
L
LF
left
11
/ Gas connection
GAS CONNECTION
Warning!
DO NOT USE AN OPEN FLAME WHEN
CHECKING FOR LEAKS!
Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions. Before placing the oven into operation, always check
for leaks with soapy water solution or other acceptable method.
Check for gas leakage with soapy water solution or
other acceptable methods in all gas connections
installed between inlet gas pipe of the appliance,
gas regulator, till to the manual shut-off valve.
All gas connections must comply with national and
local codes. The gas supply line (service) must be
the same size or greater than the inlet line of the
appliance. This range uses a 1/2” NPT inlet (see
drawing below for details of gas connection). On
all pipe joints use appropriate sealant resistant to
gas to joint the adapter to range manifold use only
the blue gasket supplied.
If necessary, the appliance must be converted by
the dealer, by a factory-trained professional or by
a qualifi ed licensed plumber or gas service company.
FLEXIBLE CONNECTIONS
In case of installation with fl exible couplings and/
or quick-disconnect fi ttings, the installer must use
a heavy-duty, AGA design-certifi ed commercial
fl exible connector of at least 1/2” (1.3 cm) ID NPT
(with suitable strain reliefs) in compliance with
ANSI Z21.41 and Z21.69 standards.
In Massachusetts: The unit must be installed
with a 36” (3-foot) long fl exible gas connector.
In Canada: use CAN 1-6.10-88 metal connec-
tors for gas appliances and CAN 1-6.9 M79 quick
disconnect device for use with gas fuel.
PRESSURE TEST-POINT STOPPER
VALVE
To avoid gas leaks, the pressure test-point stopper valve and gasket supplied with the range must
be installed on the gas fi tting at the back of the
range according to the diagram below.
Gas conversion is important for safe and eff ective use of the appliance. It is the responsibility of
the dealer and the owner of the range to perform
the appropriate gas conversion following the directions of the manufacturer.
THE GAS CONVERSION PROCEDURE IS
DESCRIBED IN THIS MANUAL AND IN THE
PACKAGE CONTAINING THE CONVERSION
NOZZLES SHIPPED WITH EVERY RANGE.
Please provide the service person with this manual before work is started on the range.
MANUAL SHUT-OFF VALVE
THIS VALVE IS NOT SHIPPED WITH THE APPLIANC AND MUST BE SUPPLIED BY THE INSTALLER.
The manual shut-off valve must be installed in the
gas service line between the gas hook-up on the
wall and the appliance inlet, in a position where it
can be reached quickly in the event of an emergency.
GAS PIPE
BASKET
GAS CONNECTION ADAPTOR
1/2’’NPT WITH PRESSURE TEST
POINT 1/8’’ NPT (TO BE FIXED
TOWARD EXTERNAL SIDE OF
THE APPLIANCE)
PRESSURE TEST-POINT
STOPPER
In Massachusetts: A ‘T’ handle type manual
gas valve must be installed in the gas supply line
to this appliance.
12
PRESSURE REGULATOR
Since service pressure may fl uctuate with local
demand, every gas cooking appliance must be
equipped with a pressure regulator on the incoming service line for safe and effi cient operation.
The pressure regulator shipped with the appliance has two female threads ½” NPT. The regulator
shall be installed properly in order to be accessible
when the appliance is installed in its fi nal position.
/ Gas connection
Manifold pressure should be checked with a manometer and comply with the values indicated below:
Natural gas 4.0” W.c.P.
LP/Propane 11.0” W.C.P.
Incoming line pressure upstream from the regulator must be 1” W.c.P. higher than the manifold
pressure in order to check the regulator.
The regulator used on this range can withstand a
maximum input pressure of 1/2 PSI (13,8” w.c. or
3,5 kPa) If the line pressure exceeds that amount,
a stepdown regulator is required.
The appliance, its individual shut-off valve, and
the pressure regulator must be disconnected from
the gas line during any pressure testing of that system at pressures in excess of 1/2 PSI (13,8” w.c.
or 3,5 kPa).
The individuaL manual shut-off valve must be in
the OFF position during any pressure testing of
the gas supply piping system at test pressures
equal to or less than 1/2 PSI (13,8” w.c. or 3,5
kPa).
Warning
Before carrying out any servicing operation disconnect the appliance from gas and electric
supply and extra appliance from fi nal installation
place in order to have access to the appliance for
proper servicing intervention.
13
/ Installation
INSTALLATION
APPLIANCE INSTALLATION
Unpacking the range
• Remove all packing materials from the ship-
ping pallet but leave the adhesive-backed foam
layer over brushed-metal surfaces to protect it
from scratches until the range is installed in its
fi nalposition. Only the fi lm on the side panels
should be removed before inserting the range
between the cabinets.
• Examine the appliance after unpacking it. In the
event of transport damage, do not plug it. Take
pictures of the damage and report it immediately to the freight forwarder.
• Remove the oven door(s). This will reduce the
weight of the range.
• The grates, griddle plate, burner caps, and oven
racks should be removed to facilitate handling.
• Before moving the range, protect the fl oor to
prevent damage.
REMOVING THE OVEN DOOR
Prepare the door for removal. Flip up the locking
clamps on each door hinge. Slowly shut the door
until the protruding clamps stop the movement.
Pull oven door upwards and remove.
Do not lift or carry the oven door by its handle!
This may damage the hinges.
1
2
14
3
/ Installation
INSTALLING THE LEGS
Bertazzoni ranges must be used only with the legs
properly installed.
Four height-adjustable legs are supplied with the
range in the polysterene container situated over
the appliance.
Before installing the legs, position the appliance
near its fi nal location as the legs are not suitable
for moving the appliance over long distances.
After unpacking the range, raise it enough to insert the legs in the appropriate receptacles situated on the lower part of the appliance. Lower the
range gently to keep any undue strain from legs
and mounting hardware. If possible use a pallet or
lift jack instead of tilting the unit.
Adjust leg height to the desired level by twisting
the inside portion of the leg assembly until the proper height is reached. Check with a level that the
cooktop is perfectly level.
INSTALLING THE WORKTOP
FRONTGUARD
To increase the clearance between the front edge
of the worktop and the burners it is possible to
install the worktop frontguard shipped with the appliance.
To install the front guard,
• Locate the two fi xing holes on the end of the
frontguard
• Locate the two fi xing holes in the bottom side of
the worktop
• Fix the frontguard with the 2 supplied screw
1
2
3
4
15