Dear Customer, Thank you for preferring a Beko product. We hope that you get the best results
from your product which has been manufactured with high quality and state-of­the-art technology. Therefore, please read this entire user manual and all other accompanying documents carefully before using the product and keep it as a reference for future use. If you handover the product to someone else, give the user manual as well. Follow all warnings and information in the user manual.
Meanings of the symbols
Following symbols are used in the various section of this manual:
C
Important information or useful hints about usage.
A
Warning for hazardous situations with regard to life and property.
Warning to actions that must never perform.
This product has been produced in environmentally friendly, modern facilities
Complies with the WEEE Regulation. Does not contain PCB.
B
Warning for electric shock.
Warning for danger of fire.
Warning for hot surfaces.
Splıt-type room air conditioner / User Manual
3 / 52 EN
1 Safety nstructons 4
2 Unt specfcatons and features 7
2.1 Unit parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.2 Achieving optimal performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.3 Inverter split type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.4 Fixed-speed type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.5 Other features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Manual operaton (wthout remote) 13
3.1 How to operate your unit without the remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4 Care and mantenance 14
4.1 Cleaning your indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.2 Cleaning your air filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.3 Air filter reminders (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.4 Maintenance - long periods of non-use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.5 Maintenance -pre-season inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5 Troubleshootng 19
5.1 Common issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6 European dsposal gudelnes 23
7 Installaton nstructons 24
7.1 F-Gas instruction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8 Specfcaton 25
CONTENTS
4 / 52 EN
Splıt-type room air conditioner / User Manual
Read safety precautions before installation Incorrect installation due to ignoring instructions can
cause serious damage or injury.
The seriousness of potential damage or injuries is classified as
Warning. Warning
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Installation warnings
Ask an authorized dealer to install this air conditioner. Inappropriate installation may cause water leakage, electric shock, or fire.
All repairs, maintenance and relocation of this unit must be performed by an authorized service technician. Inappropriate repairs can lead to serious injury or product failure.
Warnings for product use
If an abnormal situation arises (like a burning smell), immediately turn off the unit and pull the power plug. Call your dealer for instructions to avoid electric shock, fire or injury.
Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
1 Safety nstructons
Splıt-type room air conditioner / User Manual
5 / 52 EN
1 Safety nstructons
Do not use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.
Do not operate the air conditioner in places near or around combustible gases. Emitted gas may collect around the unit and cause explosion.
Do not operate the air conditioner in a wet room (e.g., bathroom or laundry room). This can cause electrical shock and cause the product to deteriorate.
Do not expose your body directly to cool air for a prolonged period of time.
Electrical warnings
Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer or certified service agent.
Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire or electric shock.
Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can damage it, which can lead to fire or electric shock.
Do not use an extension cord, manually extend the power cord, or connect other appliances to the same outlet as the air conditioner. Poor electrical connections, poor insulation, and insufficient voltage can cause fire.
Cleaning and maintenance warnings
Turn off the device and pull the plug before cleaning. Failure to do so can cause electrical shock.
6 / 52 EN
Splıt-type room air conditioner / User Manual
Do not clean the air conditioner with excessive amounts of water.
Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause fire or deformation.
Warning
If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
Turn off the air conditioner and unplug the unit if you are not going to use it for a long time.
Turn off and unplug the unit during storms.
Make sure that water condensation can drain unhindered from the unit.
Do not operate the air conditioner with wet hands. This may cause electric shock.
Do not use device for any other purpose than its intended use.
Do not climb onto or place objects on top of the outdoor unit.
Do not allow the air conditioner to operate for long periods of time with doors or windows open or if the humidity is very high.
1 Safety nstructons
Splıt-type room air conditioner / User Manual
7 / 52 EN
2.1 Unt parts
2
1
3
4
6
5
7
8
Fresh
Fresh
Defrost
Defrost
Run
Run
Timer
Timer
1. Display window (A)
2. Power Cable (Some Units)
3. Remote Control
4. Remote Control Holder (Some Units)
5. Display window (B)
6. Display window (C)
7. Louver
8. Front Panel
Display Code Meanings
"Fresh"
when Fresh feature is activated(some units)
"Defrost"
when defrost feature is activated.
"Run"
when the unit is on.
"Timer"
when TIMER is set.
" " Not available for all units. When ECO function(some units) is activated, the ' ' illuminates gradually one by one as -- -- --
-- set temperature -- ...... in one second interval.
In other modes, the unit will display your temperature setting. In Fan mode, the unit will display the room temperature. When error occurs, it displays error code.
" " for 3 seconds when:
•
TIMER ON is set
2 Unt specfcatons and features
8 / 52 EN
Splıt-type room air conditioner / User Manual
•
FRESH, SWING, TURBO, or SILENCE features are turned on
" " for 3 seconds when:
•
TIMER OFF is set
•
FRESH, SWING, TURBO, or SILENCE features are turned off " " when anti-cold air feature is turned on " " when defrosting " " when unit is self-cleaning " " when freeze protection is turned on
" " when Wireless Control feature is activated(some units)
C
Note: A guide on using the infrared remote is not included in this literature package.
2.2 Achevng optmal performance
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform less than optimally.
2.3 Inverter splt type
COOL mode HEAT mode DRY mode
Room Temperature 17°C - 32°C
(63°F - 90°F)
0°C - 30°C (32°F - 86°F)
10°C - 32°C (50°F - 90°F)
Outdoor Temperature
0°C - 50°C (32°F - 122°F)
-15°C - 30°C (5°F - 86°F)
0°C - 50°C (32°F - 122°F)
-15°C - 50°C (5°F - 122°F) (For models with
low temp. cooling systems.)
0°C - 60°C (32°F - 140°F) (For special tropical
models)
0°C - 60°C (32°F - 140°F) (For special tropical
models)
2 Unt specfcatons and features
Splıt-type room air conditioner / User Manual
9 / 52 EN
For outdoor units with auxiliary electric heater
When outside temperature is below 0°C (32°F ), we strongly recommend keeping the unit plugged in at all time to ensure smooth ongoing performance.
2.4 Fxed-speed type
COOL mode HEAT mode DRY mode
Room Temperature
17°-32°C (63°-90°F)
0°-30°C (32°-86°F)
10°-32°C (50°-90°F)
Outdoor Temperature
18°-43°C (64°-109°F)
-7°-24°C (19°-75°F)
11°-43°C (52°-109°F)
-7°-43°C (19°-10 9°F) (For models with low-temp
cooling systems)
18°-43°C (64°-109°F)
18°-54°C (64°-129°F) (For special tropical models)
18°-54°C (64°-129°F) (For special tropical models)
To further optimize the performance of your unit, do the following:
•
Keep doors and windows closed.
•
Limit energy usage by using TIMER ON and TIMER OFF functions.
•
Do not block air inlets or outlets.
•
Regularly inspect and clean air filters. For a detailed explanation of each function, refer to the Remote control manual.
2.5 Other features
•
Auto-restart
If the unit loses power, it will automatically restart with the prior settings once power has been
restored.
•
Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will continue
operate at very low power to dry up condensed water and prevent mildew growth.
•
Refrigerant Leakage Detection (some units)
The indoor unit will automatically display “EC” when the unit detects refrigerant leakage.
2 Unt specfcatons and features
10 / 52 EN
Splıt-type room air conditioner / User Manual
•
Wireless control (some units)
Wireless control allows you to control your air conditioner using your mobile phone and a Wireless
connection.
For the USB device access, replacement, maintenance operations must be carried out by
professional staff.
•
Louver angle memory (some units)
When turning on your unit, the louver will automatically resume its former angle. For a detailed explanation of your unit's advanced functionality (such as TURBO mode and its self-
cleaning functions), refer to the Remote Control Manual.
C
Note:
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.
•
Setting angle of air flow Setting vertical angle of air flow
While the unit is on, use the SWING/DIRECT button to set the direction (vertical angle) of airflow.
1. Press the SWING/DIRECT button once to activate the louver. Each time you press the button, it
will adjust the louver by 6°. Press the button until the direction you prefer is reached.
2. To make the louver swing up and down continuously, press and hold the SWING/DIRECT button
for 3 seconds. Press it again to stop the automatic function.
Setting horizontal angle of air flow
The horizontal angle of the airflow must be set manually. Grip the deflector rod (See Fig.B) and manually adjust it to your preferred direction.
For some units, the horizontal angle of the airflow can be set by remote control, please refer to the Remote Control Manual.
C
Note on louver angles
When using COOL or DRY mode, do not set louver at too vertical an angle for long periods of time. This can cause water to condense on the louver blade, which will drop on your floor or furnishings. (See Fig.A)
When using COOL or HEAT mode, setting the louver at too vertical an angle can reduce the performance of the unit due to restricted air flow.
Do not move louver by hand. This will cause the louver to become out of sync. If this occurs, turn off the unit and unplug it for a few seconds, then restart the unit. This will reset the louver.
2 Unt specfcatons and features
Splıt-type room air conditioner / User Manual
11 / 52 EN
Range
Fig. A
A
Warnng
Do not keep louver at too vertical an angle for long periods of time. This can cause water condensation to drip on your furnishings.
A
Warnng
Do not put your fingers in or near the blower and suction side of the unit. The high­speed fan inside the unit may cause injury.
Deflector rod
Fig. B
2 Unt specfcatons and features
12 / 52 EN
Splıt-type room air conditioner / User Manual
•
Sleep operation
The SLEEP function is used to decrease energy use while you sleep (and don't need the same
temperature settings to stay comfortable). This function can only be activated via remote control.
Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will
increase the temperature by 1°C (2°F) after 1 hour, and will increase an additional 1°C (2°F) after
another hour. When in HEAT mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour,
and will decrease an additional 1°C (2°F) after another hour.
It will hold the new temperature for 5 hours, then the unit will turn off automatically.
C
Note: The SLEEP function is not available in FAN or DRY mode.
1hr 1hr
+/- 1˚C/2˚F +/- 1˚C/2˚F
SLEEP Operation
Saving energy during sleep
Set
temperature
7 hours
timer off
2 Unt specfcatons and features
Splıt-type room air conditioner / User Manual
13 / 52 EN
3 Manual operaton (wthout remote)
3.1 How to operate your unt wthout the remote control
In the event that your remote control fails to work, your unit can be operated manually with the MANUAL CONTROL button located on the indoor unit. Note that manual operation is not a long-term solution, and that operating the unit with your remote control is strongly recommended.
Before manual operation
Unit must be turned off before manual operation. To operate your unit manually:
1. Open the front panel of the indoor unit.
2. Locate the MANUAL CONTROL button on the right-hand side of the unit.
3. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
4. Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
5. Press the MANUAL CONTROL button a third time to turn the unit off.
6. Close the front panel.
A
Warnng
The manual button is intended for testing purposes and emergency operation only. Please do not use this function unless the remote control is lost and it is absolutely necessary. To restore regular operation, use the remote control to activate the unit.
Manual control button
14 / 52 EN
Splıt-type room air conditioner / User Manual
4 Care and mantenance
4.1 Cleanng your ndoor unt
A
Before cleanng or mantenance
Always turn off your air conditioner system and disconnect its power supply before cleaning or maintenance.
A
Warnng
Only use a soft, dry cloth to wipe the unit clean. If the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.
•
Do not use chemicals or chemically treated cloths to clean the unit
•
Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
•
Do not use water hotter than 40°C (104°F) to clean the front panel. This can cause the panel to deform or become discolored.
4.2 Cleanng your ar flter
A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to clean the filter once every two weeks.
1. Lift the front panel of the indoor unit.
2. First press the tab on the end of filter to loosen the buckle, lift it up, then pull it towards yourself.
3. Now pull the filter out.
4. If your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening
filter with a hand-held vacuum.
5. Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
6. Rinse the filter with fresh water, then shake off excess water.
7. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
8. When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
9. Close the front panel of the indoor unit.
Splıt-type room air conditioner / User Manual
15 / 52 EN
Filter Tab
Remove air freshening filter from back of
larger filter (some units)
A
Warnng
Do not touch air freshening (Plasma) filter for at least 10 minutes after turning off the unit.
4 Care and mantenance
16 / 52 EN
Splıt-type room air conditioner / User Manual
A
Warnng
•
Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
•
When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
•
Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
•
Do not expose filter to direct sunlight when drying. This can shrink the filter.
4.3 Ar flter remnders (optonal)
4.3.1 Ar flter cleanng remnder
After 240 hours of use, the display window on the indoor unit will flash "CL." This is a reminder to clean your filter. After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don't reset the reminder, the "CL" indicator will flash again when you restart the unit.
4.3.2 Ar flter replacement remnder
After 2,880 hours of use, the display window on the indoor unit will flash "nF." This is a reminder to replace your filter. After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don't reset the reminder, the "nF" indicator will flash again when you restart the unit.
A
Warnng
•
Any maintenance and cleaning of outdoor unit should be performed by an authorized dealer or a licensed service provider.
•
Any unit repairs should be performed by an authorized dealer or a licensed service provider.
4 Care and mantenance