Bauknecht WGD9550W, WGD9470W, WGD9450W, WGD9600T, WGD9750W Manual

0 (0)
Bauknecht WGD9550W, WGD9470W, WGD9450W, WGD9600T, WGD9750W Manual

DuetSteam and Non-Steam Electronic Gas Dryer

PRODUCT MODEL NUMBERS

 

 

OVERALL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WGD9450W, WGD9470W, WGD9550W,

Dryer dimensions

STEAM - 529/16"

Custom undercounter installation-dryer only

WGD9600T, WGD9750W

 

 

(1335 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas supply: This dryer is equipped for use with Natural

 

 

NON-STEAM - 511/

2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1308 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gas. Dryer can be converted to L.P. gas. When rigid

 

 

 

38"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pipe is used it should be 1/2" IPS. When acceptable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(965 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the gas supplier and local codes, 3/8" approved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tubing may be used for lengths under 20 ft (6.1 m).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For lengths over 20 ft (6.1 m), larger tubing should be

38"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

used. Pipe-joint compounds resistant to the action of

 

 

 

1"*

 

 

 

 

 

 

27"

 

 

 

 

 

1"*

 

(965 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L.P. gas must be used. An individual manual shutoff

 

 

 

 

 

 

 

 

(25 mm)

 

 

(686 mm)

 

 

(25 mm)

valve must be installed within 6 ft (1.8 m) of the dryer

 

 

 

 

Most installations require a minimum

in accordance with the National Fuel Gas Code ANSI

 

 

 

 

 

 

 

 

5" (127 mm) clearance behind the dryer for

Z223.1.

 

 

 

 

 

 

 

 

the exhaust vent with elbow. See Installation

 

*STEAM - 329/16"

27"

 

Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp

 

Instructions, “Venting Requirements.”

fused electrical supply is required for gas dryers, 30

(827 mm)

(686 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NON-STEAM - 311/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amp for electric dryers. A time-delay fuse or circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

breaker and a separate circuit are recommended.

(800 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water (Steam models only): The dryer must be

For closet installation, with a door, the minimum ventilation openings in the top and

bottom of the door are required. Louvered doors with equivalent air

 

 

connected to the cold water faucet using new inlet

 

 

ventilation openings are acceptable.

 

 

 

 

hoses. Do not use old hoses. Do not overtighten.

 

 

 

 

 

 

 

 

 

 

 

Damage to the coupling can result.

 

 

 

 

 

6"

 

 

Exhaust venting: Exhaust your dryer to the outside.

 

 

 

 

(152 mm)

 

 

3"

 

 

 

 

 

4" (102 mm) diameter vent is required. Rigid or flexible

 

 

 

 

 

 

 

(76 mm)

14" max.

 

 

 

 

metal exhaust vent must be used. Do not use plastic

 

 

 

 

 

48 in.2 *

 

(356 mm)

 

 

 

 

or metal foil vet. Exhaust hood must be at least

 

 

 

 

 

12" (305 mm) from the ground or any object that

(310 cm2)

 

18" max.

 

 

 

 

may be in the path of the exhaust.

 

 

 

 

 

 

 

 

 

 

(457 mm)

 

76"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hood styles: A & B are recommended.

 

 

 

 

(1930 mm)

 

 

B

4"

C

 

 

 

 

 

 

 

 

 

(102 mm)

 

24 in.2 *

3"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(155 cm2)

 

 

 

 

 

 

 

 

 

(76 mm)

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1"

27"

1"

 

 

 

 

 

 

 

 

 

 

 

2½"

 

 

STEAM - 329/16"

STEAM - 51/2"**

(25 mm)

(686 mm) (25 mm)

 

4"

 

(64 mm)

 

 

(827 mm)

(140 mm)

 

 

 

 

A. Louvered hood

 

NON-STEAM - 311/2" NON-STEAM - 5"**

 

 

 

 

(102 mm)

 

 

 

 

4"

 

B. Box hood

 

 

 

(800 mm)

(127 mm)

 

 

 

 

C. Angled hood (acceptable)

 

 

 

 

 

 

 

(102 mm)

For dryer on pedestal; cabinet installation, with a door, the minimum ventilation

 

 

 

 

The vent system chart provides venting requirments

openings in the top are required.

 

 

 

 

that will help to achieve the best drying performance.

 

7"*

 

 

 

 

 

 

 

 

 

 

 

7"*

 

 

 

Vent system chart:

 

 

 

(178 mm)

 

 

 

 

 

 

 

 

(178 mm)

 

 

 

 

 

 

 

 

 

NOTE: Side and bottom exhaust installations have

 

 

14"* max.

 

 

 

 

a 90° turn inside the dryer. To determine maximum

 

 

 

 

 

 

exhaust length, add one 90° turn to the chart.

 

 

(356 mm)

 

 

 

 

Number of

Type of

Box or

Angled

 

 

18"* max.

 

 

 

9"*

90o turns

vent

Louvered

hoods

 

 

 

 

 

or elbows

 

hoods

 

 

 

(457 mm)

 

 

 

(229 mm)

 

 

 

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

 

 

 

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

 

 

 

 

 

 

 

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

 

 

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

 

 

 

 

 

 

 

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

 

 

 

 

1"*

27"

1"*

 

STEAM - 329/16"

5"

(25 mm)

(686 mm) (25 mm)

 

 

 

 

 

 

 

 

 

 

(827 mm)

(127 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NON-STEAM - 311/2"

 

 

 

 

 

 

 

 

 

(800 mm)

 

 

 

 

 

 

 

 

 

 

37/16"

 

 

 

 

33/8"

 

*Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed.

1"

 

 

 

 

 

 

 

 

 

 

 

(87 mm)

1"

 

 

 

 

 

 

 

 

(86 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select the route that will provide the straightest and most direct path outdoors.

(25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

(25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plan the installation to use the fewest number of elbows and turns.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use the fewest 90° turns possible.

 

 

 

 

 

 

 

 

 

 

14"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75/8"

 

 

 

 

 

 

 

 

Do not use vent runs longer than specified in vent length chart.

 

 

 

 

 

 

 

 

 

(356 mm)

 

 

 

 

 

 

 

 

 

(194 mm)

 

 

 

 

 

 

 

 

Back View

 

 

 

 

 

Side View

 

Determine the number of elbows you will need.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10255469B

Instructions packed with product. Specifications subject to change without notice.