Asus RS700D-E6/PS8 User Manual

RS700D-E6/PS8
1U Rackmount Server User Guide
E4519
First Edition
March 2009
Copyright © 2009 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not
limited to the implied warranties or conditions of merchantability or tness for a particular purpose. In no event shall ASUS, its directors, ofcers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of prots, loss of business, loss of use or data,
interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product.
Specications and information contained in this manual ae furnished for informational use only, and are
subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the owners’ benet, without intent to infringe.
ii
Contents
Notices ........................................................................................................ vii
Safety information .................................................................................... viii
About this guide ......................................................................................... ix
Chapter 1: Product introduction
1.1 System package contents ........................................................... 1-2
1.2 Serial number label ...................................................................... 1-2
1.3 Systemspecications ................................................................. 1-3
1.4 Front panel features ..................................................................... 1-5
1.5 Rear panel features ...................................................................... 1-5
1.6 Internal features ........................................................................... 1-6
1.7 LED information ........................................................................... 1-7
1.7.1 Front panel LEDs ............................................................ 1-7
1.7.2 LAN (RJ-45) LEDs .......................................................... 1-7
1.7.3 HDD status LED .............................................................. 1-8
Chapter 2: Hardware setup
2.1 Chassis cover ............................................................................... 2-2
2.2 Central Processing Unit (CPU) ................................................... 2-3
2.1.1 Installing the CPU ........................................................... 2-3
2.2.2 Installing the CPU heatsink and airduct .......................... 2-6
2.3 System memory ........................................................................... 2-7
2.2.1 Overview ......................................................................... 2-7
2.3.2 Memory Congurations ................................................... 2-8
2.3.3 Installing a DIMM ............................................................ 2-9
2.3.4 Removing a DIMM .......................................................... 2-9
2.4 Hard disk drives ......................................................................... 2-10
2.5 Expansion slot ............................................................................ 2-11
2.5.1 Installing an expansion card to the riser card bracket ....2-11
2.5.2 Conguring an expansion card ..................................... 2-12
2.6 Cable connections ..................................................................... 2-13
2.7 Removable/optional components ............................................. 2-14
2.7.1 Replacing system fans .................................................. 2-14
2.7.2 Replacing power supply units ....................................... 2-15
2.7.3 Installing ASMB4 series management board (optional) 2-16
iii
Contents
Chapter 3: Installation options
3.1 Rackmount rail kit items (optional) ............................................ 3-2
3.2 Attaching the rails to the server ................................................. 3-2
3.3 Attaching the rack rails ............................................................... 3-3
3.4 Rackmounting the server ............................................................ 3-4
Chapter 4: Motherboard Info
4.1 Motherboard layout ...................................................................... 4-2
4.2 Jumpers ........................................................................................ 4-4
4.3 Internal connectors ...................................................................... 4-8
4.4 Internal LEDs .............................................................................. 4-16
Chapter 5: BIOS setup
5.1 Managing and updating your BIOS ............................................ 5-2
5.1.1 AFUDOS utility ................................................................ 5-2
5.1.2 ASUS CrashFree BIOS 3 utility ...................................... 5-4
5.2 BIOS setup program .................................................................... 5-5
5.2.1 BIOS menu screen .......................................................... 5-6
5.2.2 Menu bar ......................................................................... 5-6
5.2.3 Navigation keys ............................................................... 5-6
5.2.4 Menu items ..................................................................... 5-7
5.2.5 Sub-menu items .............................................................. 5-7
5.2.6 Conguration elds ......................................................... 5-7
5.2.7 Pop-up window ............................................................... 5-7
5.2.8 Scroll bar ......................................................................... 5-7
5.2.9 General help ................................................................... 5-7
5.3 Main menu .................................................................................... 5-8
5.3.1 System Time ................................................................... 5-8
5.3.2 System Date ................................................................... 5-8
5.3.3 SATA1–4 ......................................................................... 5-8
5.3.4 IDE Conguration .......................................................... 5-10
5.3.5 AHCI Conguration ........................................................5-11
5.3.6 System Information ....................................................... 5-12
5.4 Advanced menu ......................................................................... 5-13
5.4.1 CPU Conguration ........................................................ 5-13
iv
Contents
5.4.2 Chipset Conguration ................................................... 5-16
5.4.3 Legacy Device Conguration ........................................ 5-20
5.4.4 USB Conguration ........................................................ 5-21
5.4.5 PCIPnP Conguration ................................................... 5-22
5.4.6 Power On conguration ................................................ 5-23
5.4.7 Event Log Conguration ............................................... 5-24
5.4.8 Hardware Monitor ......................................................... 5-25
5.4.9 PCI Express Conguration ............................................ 5-26
5.4.10 ACPI Conguration ....................................................... 5-27
5.5 Server menu ............................................................................... 5-29
5.5.1 Remote Access Conguration ....................................... 5-29
5.6 Boot menu .................................................................................. 5-31
5.6.1 Boot Device Priority ...................................................... 5-31
5.6.2 Boot Settings Conguration .......................................... 5-32
5.6.3 Security ......................................................................... 5-33
5.7 Exit menu .................................................................................... 5-35
Chapter6: RAIDconguration
6.1 Setting up RAID ............................................................................ 6-2
6.1.1 RAID denitions .............................................................. 6-2
6.1.2 Installing hard disk drives ................................................ 6-2
6.1.3 RAID controller selection ................................................ 6-3
6.1.4 Setting the RAID item in BIOS ........................................ 6-3
6.2 LSISoftwareRAIDCongurationUtility .................................... 6-4
6.2.1 Creating a RAID set ........................................................ 6-5
6.2.2 Adding or viewing a RAID conguration ........................6-11
6.2.3 Initializing the virtual drives ........................................... 6-12
6.2.4 Rebuilding failed drives ................................................. 6-16
6.2.5 Checking the drives for data consistency ..................... 6-18
6.2.6 Deleting a RAID conguration ....................................... 6-21
6.2.7 Selecting the boot drive from a RAID set ...................... 6-22
6.2.8 Enabling WriteCache .................................................... 6-23
6.3 Intel® Matrix Storage Manager Option ROM Utility ................. 6-24
6.3.1 Creating a RAID set ...................................................... 6-25
6.3.2 Creating a Recovery set ............................................... 6-26
v
Contents
6.3.3 Deleting a RAID set ...................................................... 6-28
6.3.4 Resetting disks to Non-RAID ........................................ 6-29
6.3.5 Recovery Volume Options ............................................ 6-30
6.3.6 Exiting the Intel® Matrix Storage Manager .................... 6-31
6.3.7 Rebuilding the RAID ..................................................... 6-31
6.3.8 Setting the Boot array in the BIOS Setup Utility ............ 6-33
Chapter 7: Driver installation
7.1 RAID driver installation ............................................................... 7-2
7.1.1 Creating a RAID driver disk ............................................ 7-2
7.1.2 Installing the RAID controller driver ................................ 7-5
7.2 Intel® chipset device installation .............................................. 7-12
7.3 LAN driver installation ............................................................... 7-14
7.4 VGA driver installation............................................................... 7-17
7.5 Management applications and utilities installation ................ 7-19
7.5.1 Running the support DVD ............................................. 7-19
7.5.2 Drivers menu ................................................................. 7-19
7.5.3 Utilities menu ................................................................ 7-20
7.5.4 Make disk menu ............................................................ 7-20
7.5.5 Contact information ....................................................... 7-20
vi

Notices

Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturer’s instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING! The use of shielded cables for connection of the monitor to the
graphics card is required to assure compliance with FCC regulations. Changes
or modications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
Canadian Department of Communications Statement
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
This Class A digital apparatus complies with Canadian ICES-003.
REACH
Complying with the REACH (Registration, Evaluation, Authorization, and Restriction
of Chemicals) regulatory framework, we publish the chemical substances in our products at ASUS REACH website at http://green.asus.com/english/REACH.htm.
vii

Safety information

Electrical Safety
Before installing or removing signal cables, ensure that the power cables for
the system unit and all attached devices are unplugged.
To prevent electrical shock hazard, disconnect the power cable from the
electrical outlet before relocating the system.
When adding or removing any additional devices to or from the system, contact a qualied service technician or your dealer. Ensure that the power cables for
the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you service.
If the power supply is broken, do not try to x it by yourself. Contact a qualied
service technician or your dealer.
Operation Safety
Servicing of this product or units is to be performed by trained service personnel only.
Before operating the server, carefully read all the manuals included with the
server package.
Before using the server, make sure all cables are correctly connected and the
power cables are not damaged. If any damage is detected, contact your dealer as soon as possible.
To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry.
Avoid dust, humidity, and temperature extremes. Place the server on a stable surface.
viii
This product is equipped with a three-wire power cable and plug for the user’s safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock.
Lithium-Ion Battery Warning
CAUTION! Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
CD-ROM Drive Safety Warning
CLASS 1 LASER PRODUCT
Heavy System
CAUTION! This server system is heavy. Ask for assistance when moving or
carrying the system.
DO NOT throw the motherboard in municipal waste. This product has been designed to enable proper reuse of parts and recycling. This symbol of the crossed out wheeled bin indicates that the product (electrical and electronic equipment) should not be placed in municipal waste. Check local regulations for disposal of electronic products.
DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol of the crossed out wheeled bin indicates that the battery should not be placed in municipal waste.

About this guide

Audience
This user guide is intended for system integrators, and experienced users with at
least basic knowledge of conguring a server.
Contents
This guide contains the following parts:
1. Chapter 1: Product Introduction
This chapter describes the general features of the server, including sections
on front panel and rear panel specications.
2. Chapter 2: Hardware setup
This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.
3. Chapter 3: Installation options
This chapter describes how to install the optional components and devices into the barebone server.
4. Chapter 4: Motherboard information
This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors.
5. Chapter 5: BIOS information
This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters.
6. Chapter6:RAIDconguration
This chapter provides instructions for setting up, creating and conguring
RAID sets using the available utilities.
7 Chapter 7: Driver installation
This chapter provides instructions for installing the necessary drivers for different system components.
ix
Conventions
To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual.
DANGER/WARNING: Information to prevent injury to yourself when
trying to complete a task.
CAUTION: Information to prevent damage to the components when
trying to complete a task.
IMPORTANT: Instructions that you MUST follow to complete a task.
NOTE: Tips and additional information to help you complete a task.
Typography
Bold text
Italics
<Key> Keys enclosed in the less-than and greater­ than sign means that you must press the enclosed key.
Example: <Enter> means that you must press the Enter or Return key.
<Key1+Key2+Key3> If you must press two or more keys simultaneously, the key names are linked with a plus sign (+).
Example: <Ctrl+Alt+D>
Command
exactly as shown, then supply the required item or value enclosed in brackets.
Example: At the DOS prompt, type the command line:
Indicates a menu or an item to select.
Used to emphasize a word or a phrase.
Means that you must type the command
format A:/S
References
Refer to the following sources for additional information, and for product and software updates.
1. ASUS Server Web-based Management (ASWM) user guide
This manual tells how to set up and use the proprietary ASUS server management utility.
2. ASUS websites
The ASUS websites worldwide provide updated information for all ASUS hardware and software products. Refer to the ASUS contact information.
x
Chapter 1
This chapter describes the general features of the server, including sections on front panel and rear panel
specications.
ASUS RS700D-E6/PS8
Product introduction

1.1 System package contents

Check your system package for the following items.
Model Name RS700D-E6/PS8 Chassis ASUS R12B 1U Rackmount Chassis Motherboard ASUS Z8NH-D12 Server Board Component 2 x 770W Single Power Supply
Accessories 1 x RS700D-E6/PS8 User’s Guide
Optional Items CPU Heatsink
* ASUS System Web-based Management
**ThesystemdoesnotincludeaUSBoppydrive.YoumayhavetouseaUSBoppydrivewhen
creating a SATA RAID driver disk. Refer to Chapter 7 for details.
8 x Hot-swap 2.5” HDD trays 1 x SAS/SATA2 Backplane 2 x PCI Riser Card (ASUS RE16R-R12B) 2 x Front I/O Board (ASUS FPB-AR14) 1 x Redundant Power Supply Power Distribution Board (ASUS PDB-R12B) 8 x System Fans (40mm x 56mm)
1 x ASUS ASWM 2.0 User’s Guide 1 x RS700D-E6/PS8 Support CD (including ASWM*) 1 x Bag of Screws 2 x AC Power Cables 1 x Semi-ball Bearing Rail Kit
ASUS ASMB4-iKVM Remote management card
Anti-virus Software CD ASUS PIKE series SAS RAID card
If any of the above items is damaged or missing, contact your retailer.

1.2 Serial number label

Before requesting support from the ASUS Technical Support team, you must take note of the product’s serial number containing 12 characters such as xxxxxxxxxxxx. See the gure below.
With the correct serial number of the product, ASUS Technical Support team
members can then offer a quicker and satisfying solution to your problems.
RS700D-E6-P
xxxxxxxxxxxx
Chapter 1: Product introduction1-2
1.3 Systemspecications
The ASUS RS700D-E6/PS8 is a 1U barebone server system featuring the ASUS Z8NH-D12 server board. The server supports Intel® LGA1366 Xeon® 5500 series
processors, plus other latest technologies through the chipsets onboard.
Model Name RS700D-E6/PS8
2 x Socket LGA1366 per Node
- Quad-Core Intel® Xeon® X5500 Series (95W)
Processor / System Bus
Core Logic
ASUS Features
Memory
Expansion Slots
Storage SATA Controller
HDD Bays
Networking LAN Graphic VGA
Onboard I/O
Smart Fan ASWM2.0
Total Slots
Capacity
Memory Type
Memory Size
Total PCI/PCI-X/ PCI-E Slots
Slot Type
I = internal A or S will be hot-swappable
- Quad-Core Intel® Xeon® E5500 Series (80W)
- Quad-Core Intel® Xeon® L5500 Series
(60W/38W) QPI 4.8 / 5.86 / 6.4 GT/s
Intel® 5500 I/O Hub Intel® ICH10R I/O Controller
√ √ 12 DIMMs per Node (3-channel per CPU,
6 DIMMs per CPU)
Maximum up to 96GB (RDIMM) per Node Maximum up to 48GB (UDIMM) per Node
DDR3 1333 / 1066 / 800 Reg DIMM / Unbuffered
DIMM with ECC
1GB, 2GB, 4GB and 8GB (RDIMM) 1GB, 2GB and 4GB (UDIMM)
1 per Node
1 x PCI-E 2.0 x16 slot (x16 link) (Low prole / HL) per Node
4 x SATA2 300MB/s ports Intel Matrix Storage (for Windows only)
- Supports software RAID 0, 1, 5 & 10 LSI MegaRAID (for Linux / Windows)
- Supports software RAID 0, 1 & 10
4 x Hot-swap 2.5” HDD Bays per Node (Total 8 x 2.5” HDD in 1U)
2 x Intel® 82574L PCIE GbE LAN per Node Aspeed AST2050 8MB
Per Node:
- 1 x External Serial Port
- 3 x RJ-45 ports (1 for ASMB4-iKVM)
- 3 x USB 2.0 ports (Front x 1, Rear x 2)
- 1 x VGA port
- 1 x Internal A-type USB Port
(continued on the next page)
ASUS RS700D-E6/PS8 1-3
Windows® Server 2008 Enterprise 32 / 64-bit Windows® Server 2003 R2 Enterprise 32 / 64-bit
OS Support
RedHat® Enterprise Linux AS5.0 32 / 64-bit SuSE® Linux Enterprise Server 10 32 / 64-bit (Subject to change without any notice)
Anti-virus Software
Optional anti-virus CD Pack
Out of Band Management Solution
Remote
Hardware
Software Dimension (HH x WW x DD) Net Weight Kg (CPU, DRAM &
HDD not inclu ded) Power Supply
Optional ASMB4-iKVM for KVM-over-IP support
ASUS ASWM 2.0
686mm x 444mm x 43.4mm
16.5 Kg
770W (80+) Cold-Swap Power Supply per Node Operation temperature: 10°C ~ 35°C / Non operation
Environment
temperature: -40°C ~ 70°C Non operation humidity: 20% ~ 90% ( Non-
condensing)
*Specicationsaresubjecttochangewithoutnotice.
®
Chapter 1: Product introduction1-4

1.4 Front panel features

The barebone server displays a simple yet stylish front panel with easily accessible
features. The power and reset buttons, LED indicators, and USB port for each
Node are located on the front panel.
Rack screw
Refer to section
Hot-swap HDD bays
Hot-swap HDD bays
1.7.1 Front panel LEDs
Power button
Reset button
Location switch
USB port
for the LED descriptions.
Power LED Message LED Location LED LAN1 LED LAN2 LED HDD Access LED
Hot-swap HDD bays
Hot-swap HDD bays
Rack screw

1.5 Rear panel features

The rear panel includes the expansion slots, system power sockets, and rear fans. The I/O shields with openings for the rear panel connectors on the motherboard are also placed in the real panel.
The ports for the USB, VGA, and Gigabit LANs do not appear on the rear panel
if the motherboards are not present.
LAN port 1
LAN port*
USB ports
LAN port 2
Serial port
VGA port
Location LED
Power supply fan
Power cord connector
LAN port*
Power supply fan
Power cord connector
USB ports
LAN port 1
LAN port 2
Serial port
VGA port
Location LED
* These ports are for ASUS ASMB4-iKVM controller cards only.
ASUS RS700D-E6/PS8 1-5

1.6 Internal features

The barebone server includes the basic components as shown.
1. Power supplies and power
2
1
3
2
1
3
4
5
6 7 8
10
10
9
fans
2. PCI Express x16 slot Riser
Cards (at x16 link)
3. ASUS Z8NH-D12 server
boards
4. System fans
5. SATA/SAS backplane (hidden)
6. Hot-swap HDD tray 1 and 3—Connect to SATA1 and SATA3 ports
7. Hot-swap HDD tray 2 and 4—Connect to SATA2 and
SATA4 ports
8. Hot-swap HDD tray 1 and 3—Connect to SATA1 and SATA3 ports
9. Hot-swap HDD tray 2 and 4—Connect to SATA2 and
SATA4 ports
10. Front I/O boards (hidden)
The barebone server does not include a oppy disk drive and an optical disc drive. Connect a USB oppy disk drive or a USB ODD to any of the USB ports on the front or rear panel if you need to use a oppy disk or a optical disc.
*WARNING
HAZARDOUS MOVING PARTS
KEEP FINGERS AND OTHER BODY PARTS AWAY
Chapter 1: Product introduction1-6

1.7 LED information

1.7.1 Front panel LEDs

Power LED Message LED Location LED
HDD Access LED
LAN2 LED
LAN1 LED
LED Icon
Power LED
HDD Access LED
Message LED
Location LED
LAN LEDs
Display status
ON System power ON
OFF
Blinking
OFF
Blinking
OFF ON
OFF Blinking ON
Description
No activity Read/write data into the HDD
System is normal; no incoming event ASWM indicates a HW monitor event
Normal status Location switch is pressed (Press the location switch again to turn off)
No LAN connection LAN is transmitting or receiving data LAN connection is present

1.7.2 LAN (RJ-45) LEDs

SPEED LED
ACT/LINK LED
ACT/LINK LED SPEED LED
Status Description Status Description
OFF No link OFF 10 Mbps connection
GREEN Linked ORANGE 100 Mbps connection
BLINKING Data activity GREEN 1 Gbps connection
ASUS RS700D-E6/PS8 1-7

1.7.3 HDD status LED

HDDLEDStatusDene
Power
LED Status Description
LED
Active LED
Power
Active Green Blink Data read/write to HDD
Green Light ON Power On (detection HDD present)
Red Light ON
G/R Blinking RAID rebuilding OFF HDD not found
RAID HDD fail (HDD plug-in ready but detection error)
Chapter 1: Product introduction1-8
Chapter 2
This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.
ASUS RS700D-E6/PS8
Hardware setup

2.1 Chassis cover

Removing the rear cover
1. Loosen the two thumbscrews on the rear panel to release the rear cover from the chassis.
Thumbscrews
2. Firmly hold the cover and slide it
toward the rear panel for about half an inch until it is disengaged from the chassis.
1/2 inch distance
3. Lift the cover from the chassis.
Chapter 2: Hardware setup2-2

2.2 Central Processing Unit (CPU)

The motherboard comes with dual surface mount LGA 1366 Socket designed for
the Intel® Xeon 5500 series CPU in the Land Grid Array (LGA) package.
Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS shoulders the repair cost only if the damage is shipment/transit-related.
Keep the cap after installing the motherboard. ASUS will process Return
Merchandise Authorization (RMA) requests only if the motherboard comes
with the cap on the Socket 1366.
The product warranty does not cover damage to the socket contacts resulting from incorrect CPU installation/removal, or misplacement/loss/ incorrect removal of the PnP cap.

2.1.1 Installing the CPU

To install a CPU:
1. Locate the CPU socket on the motherboard.
Before installing the CPU, ensure that the socket box is facing towards you and
the load lever is on your left.
2-3ASUS RS700D-E6/PS8
2. Press the load lever with your
thumb (A), then move it to the left
(B) until it is released from the
retention tab.
Retention tab
A
To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU.
3. Lift the load lever in the direction of the arrow to a 135º angle.
4. Lift the load plate with your thumb
and forenger to a 100º angle.
5. Remove the PnP cap from the CPU socket.
B
Load lever
Load plate
4
3
PnP cap
Chapter 2: Hardware setup2-4
6. Position the CPU over the socket, making sure that the gold triangle is on the bottom-left corner of the
socket, and then t the socket
alignment key into the CPU notch.
The CPU ts in only one correct
orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the
socket and damaging the CPU!
7. Apply several drops of thermal paste to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is spread in an even thin layer.
Some heatsinks come with pre­applied thermal paste. If so, skip this step.
The thermal paste is toxic and inedible. If it gets into your eyes or touches your skin, ensure to wash it off immediately and seek professional medical help.
Gold triangle mark
CPU notch
Alignment key
To prevent contaminating the paste, DO NOT spread the paste with your nger
directly.
8. Close the load plate (A), and then
push the load lever (B) until it snaps
into the retention tab.
A
B
2-5ASUS RS700D-E6/PS8

2.2.2 Installing the CPU heatsink and airduct

To install the CPU heatsink:
1. Place the heatsink on top of the installed CPU, ensuring that the four fasteners match the holes on the motherboard.
2. Twist each of the four screws with a Philips (cross) screwdriver just enough to attach the heatsink to the motherboard. When the four screws are attached,
tighten them one by one to completely secure the heatsink.
A
B
B
Tighten the four heatsink screws in a diagonal sequence.
A
Chapter 2: Hardware setup2-6

2.3 System memory

2.2.1 Overview

The motherboard comes with twelve (12) Double Data Rate 3 (DDR3) Dual Inline
Memory Modules (DIMM) sockets.
The gure illustrates the location of the DDR3 DIMM sockets:
2-7ASUS RS700D-E6/PS8
2.3.2 MemoryCongurations
You may install 1 GB, 2 GB, 4 GB, or 8GB registered / unbuffered ECC DDR3 DIMMs into the DIMM sockets using the memory congurations in this section.
Always install DIMMs with the same CAS latency. For optimum compatibility, we recommend that you obtain memory modules from the
same vendor. Refer to the Qualied Vendors List on the ASUS web site.
You may install varying memory sizes in Channel A, Channel B and Channel C. The system maps the total size of the lower-sized channel for the dual-channel or triple-channel conguration. Any excess memory from the higher-sized channel is then mapped for single-channel operation.
Due to the memory address limitation on 32-bit Windows OS, when you install 4GB or more memory on the motherboard, the actual usable memory for the OS can be about 3GB or less. For effective use of memory, we
recommend that you do any of the following:
- Use a maximum of 3GB system memory if you are using a 32-bit Windows OS.
- Install a 64-bit Windows OS when you want to install 4GB or more on the
motherboard. For more details, refer to the Microsoft® support site at
http://support.microsoft.com/kb/929605/en-us.
This motherboard does not support DIMMs made up of 256 Mb (32MB)
chips or less (Memory chip capacity counts in Megabit, 8 Megabit/Mb = 1
Megabyte/MB).
Memory population table
CPU1Conguration
DIMM_A2 DIMM_A1 DIMM_B2 DIMM_B1 DIMM_C2 DIMM_C1 1 DIMMs 2 DIMMs 3 DIMMs 4 DIMMs 6 DIMMs
CPU2Conguration
1 DIMMs 2 DIMMs 3 DIMMs 4 DIMMs 6 DIMMs
-- -- -- -- --
-- -- -- --
-- -- --
DIMM_D2 DIMM_D1 DIMM_E2 DIMM_E1 DIMM_F2 DIMM_F1
-- -- -- -- --
-- -- -- --
-- -- --
-- --
-- --
Chapter 2: Hardware setup2-8

2.3.3 Installing a DIMM

Ensure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components.
1. Unlock a DIMM socket by pressing the retaining clips outward.
2. Align a DIMM on the socket
such that the notch on the DIMM matches the break on the socket.
Unlocked retaining clip
A DIMM is keyed with a notch so that it ts in only one direction. DO NOT force
a DIMM into a socket to avoid damaging the DIMM.
2
DIMM notch
1
1
3. Firmly insert the DIMM into the socket until the retaining clips snap back in place and the DIMM is properly seated.
Locked Retaining Clip

2.3.4 Removing a DIMM

Follow these steps to remove a DIMM.
1. Simultaneously press the retaining clips outward to unlock the DIMM.
1
Support the DIMM lightly with your ngers when pressing the retaining clips. The DIMM might get damaged when it ips out with extra force.
2. Remove the DIMM from the socket.
3
2
1
DIMM notch
2-9ASUS RS700D-E6/PS8

2.4 Hard disk drives

The system supports four hot-swap SATAII/SAS hard disk drives. The hard disk drive installed on the drive tray connects to the motherboard SATAII/SAS ports via the SATAII/SAS backplane. Follow the illustration below for HDD installation.
To install a hot-swap SATAII/SAS HDD
1. Release a drive tray by pushing the spring lock to the right, and then pulling the tray lever outward. The drive tray ejects slightly after you pull out the lever.
2. Firmly hold the tray lever and pull
the drive tray out of the bay.
3. Remove the drive tray supporting
pillar shown in the right gure.
Supporting pillar
4. Place a SATAII/SAS hard disk drive on the tray, and then secure it with four screws.
2
1
5. Carefully insert the drive tray and push it all the way to the depth of the bay until just a small fraction of the tray edge protrudes.
When installed, the SATAII/SAS connector on the drive connects to the SATAII/
SAS interface on the backplane.
6. Push the tray lever until it clicks, and secures the drive tray in place. The drive tray is correctly placed when its front edge aligns with the bay edge.
7. Repeat steps 1 to 5 if you wish to install a second SATAII/SAS drive.
Chapter 2: Hardware setup2-10

2.5 Expansion slot

2.5.1 Installing an expansion card to the riser card bracket

The barebone server comes with a riser card bracket. You need to remove the
bracket if you want to install PCI Express x16 expansion cards.
To install a PCI Express x16 card
1. Firmly hold the riser card bracket, and then pull it up to detach it from the PCI Express x16 slot on the motherboard.
2. Place the riser card bracket on a at and stable surface, and then
remove the screw from the slot bay.
PCI Express x16 slot
3. Install a PCI Express x16 card to the bracket as shown, and then secure the card with a screw.
4. Press the riser card bracket until the golden connectors completely
t the slot and the bracket aligns
with the rear panel.
5. Connect the cable(s) to the card, if applicable.
2-11ASUS RS700D-E6/PS8
2.5.2 Conguringanexpansioncard
After installing the expansion card, congure the it by adjusting the software
settings.
1. Turn on the system and change the necessary BIOS settings, if any. See Chapter 5 for information on BIOS setup.
2. Assign an IRQ to the card. Refer to the following tables.
3. Install the software drivers for the expansion card.
Standard Interrupt assignments
IRQ Priority Standard function
0 1 System Timer 1 2 Keyboard Controller
2 - Programmable Interrupt 4* 12 Communications Port (COM1) 5* 13 --
6 14 Floppy Disk Controller 7* 15 --
8 3 System CMOS/Real Time Clock
9* 4 ACPI Mode when used 10* 5 IRQ Holder for PCI Steering 11* 6 IRQ Holder for PCI Steering 12* 7 PS/2 Compatible Mouse Port
13 8 Numeric Data Processor
14* 9 Primary IDE Channel 15* 10 Secondary IDE Channel
* These IRQs are usually available for ISA or PCI devices.
Chapter 2: Hardware setup2-12
Loading...
+ 114 hidden pages