240 D
Dunstabzugshaube
Hotte aspirante
Afzuigkap
Cooker Hood
Montageund Gebrauchsanweisung
Manuel de montage et d’utilisation Installatieen gebruksaanwijzing
Operating and Installation Instructions
Printed on recycled paper AEG - putting words into action
68
Contents
Introduction |
70 |
Extractor version |
70 |
Filter Version |
71 |
Summer/Winter Hood Conversion |
71 |
Electrical connection |
72 |
Safety warnings |
72 |
Technical Details |
73 |
Installation |
74 |
Safety warnings |
74 |
Wall unit mounting |
76 |
Wall mounting |
76 |
Hood Operation |
77 |
Setting the fan speed |
78 |
Hood lighting |
78 |
Intensive speed “P” |
78 |
Fan timer |
79 |
Switching off the fan |
79 |
Hood operation before and after cooking |
80 |
Warnings on the activated carbon filter |
80 |
Display warning on saturation of activated carbon filter |
81 |
Open the metal grease filter |
82 |
Display warning on saturation of metal grease filter |
83 |
Safety Warnings for user |
85 |
Maintenance and care |
86 |
Attention |
86 |
Changing the light bulb |
86 |
Cleaning |
86 |
Special accessories |
87 |
Technical assistance service |
87 |
69
Introduction
Extractor version
•The hood is supplied as an extractor unit and can also be used with a filtering function by fitting one activated carbon filter (special accessory).
•The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear.
•To connect up the hose, you should first fit the bayonet-mounting flange C (Ø 120 mm) on the outlet required (if using the top outlet, fix the flange in place using the screw supplied as shown in Fig. 1). Close off the unused hole using the bayonet fitting caps D.
|
|
1 |
D |
|
|
|
|
|
|
|
2 |
5 |
4 |
|
A |
|
|
|
|
3 |
|
B |
|
|
|
|
|
1 |
C |
|
|
|
|
|
|
|
3 |
1 |
C |
|
|
|
||
|
|
|
|
|
|
|
|
|
2 |
|
5 |
|
|
A |
|
|
|
|
|
4 |
|
|
|
B |
|
|
|
|
|
|
D |
|
|
|
•Important! To use the back hole B, remove switch F from the top hole. See Fig 2.
FA
B
2
70
• Move the lever L to position A - Fig. 3.
A |
F |
A |
|
|
L |
3
•When connecting up the hood using a telescopic wall pipe, you should use an inflammable outlet hose ABS 120 (120 mm Ø) E-Nr. 942 118 611 available as an accessory.
Filter Version
•The air is filtered and recirculated through the front grid.
•Move the lever L to position F - Fig. 3.
You will need original AEG KFF activated carbon filter for this function (see Special Accessories).
Summer/Winter Hood Conversion
•To avoid excessive heat loss during the winter months, we recommend that the hood be converted from extractor version to filter version.
•In order to convert the hood, a activated carbon filter (available as an accessory) is required. Follow the instructions for operating the hood to recirculate air.
•When the temperature outdoors becomes more mild (spring), the filter can be removed and the hood converted once again for to extraction. Please consult the assembly instructions for operating the hood in extractor version.
71
Electrical connection
Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board. To isolate the cooker hood from the mains, pull the mains plug. If the appliance is permanently connected to the mains, then it must be isolated from the mains using measures provided in the electrical installation (fuses -unscrew-type fuses, cut-out, current trips or similar that have a contact separation of >3mm when open).
The manufacture declines all responsibility for malfunctions resulting from failure to comply with the above instructions.
If the power socket is applied directly above the hood this gives two advantages:
1.The socket is not visible.
2.The appliance can be disconnected at need merely be removing the plug.
Electrical connection
220-230 V – by means of fixed power cable with plug.
(Fixed connection of the appliance must only be carried out by an authorised electrician.)
72
Technical Details
Dimensions : |
|
Height x Width x Depth (in cm) |
13 x 59,9 x 51 |
Weight: |
|
Net: |
8,7 kg |
Gross: |
9,7 kg |
Maximum absorbed power: |
330 W |
Motor absorption: |
2 x 125 W |
Lighting: |
2 x 40 W |
Length of the cable: |
110 cm |
Fan powers (speed), speed in compliance with DIN 44971
(Extractor version) Speed: |
|
min. |
131 m3/h |
max. |
251 m3/h |
intensive |
360 m3/h |
(Filter version) Speed: |
|
min. |
50 m3/h |
max. |
125 m3/h |
intensive |
140 m3/h |
Flange 120 mm Ø
73