Contents

Introduction

70

Extractor version

70

Filter Version

71

Summer/Winter Hood Conversion

71

Electrical connection

72

Safety warnings

72

Technical Details

73

Installation

74

Safety warnings

74

Wall unit mounting

76

Wall mounting

76

Hood Operation

77

Setting the fan speed

78

Hood lighting

78

Intensive speed “P”

78

Fan timer

79

Switching off the fan

79

Hood operation before and after cooking

80

Warnings on the activated carbon filter

80

Display warning on saturation of activated carbon filter

81

Open the metal grease filter

82

Display warning on saturation of metal grease filter

83

Safety Warnings for user

85

Maintenance and care

86

Attention

86

Changing the light bulb

86

Cleaning

86

Special accessories

87

Technical assistance service

87

69

AEG 240D-D, 240D-W, 240D-M Manual

Introduction

Extractor version

The hood is supplied as an extractor unit and can also be used with a filtering function by fitting one activated carbon filter (special accessory).

The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear.

To connect up the hose, you should first fit the bayonet-mounting flange C (Ø 120 mm) on the outlet required (if using the top outlet, fix the flange in place using the screw supplied as shown in Fig. 1). Close off the unused hole using the bayonet fitting caps D.

 

 

1

D

 

 

 

 

 

 

2

5

4

 

A

 

 

 

3

 

B

 

 

 

 

1

C

 

 

 

 

 

 

 

3

1

C

 

 

 

 

 

 

 

 

 

 

 

2

 

5

 

 

A

 

 

 

 

4

 

 

 

B

 

 

 

 

 

D

 

 

 

Important! To use the back hole B, remove switch F from the top hole. See Fig 2.

FA

B

2

70

• Move the lever L to position A - Fig. 3.

A

F

A

 

L

3

When connecting up the hood using a telescopic wall pipe, you should use an inflammable outlet hose ABS 120 (120 mm Ø) E-Nr. 942 118 611 available as an accessory.

Filter Version

The air is filtered and recirculated through the front grid.

Move the lever L to position F - Fig. 3.

You will need original AEG KFF activated carbon filter for this function (see Special Accessories).

Summer/Winter Hood Conversion

To avoid excessive heat loss during the winter months, we recommend that the hood be converted from extractor version to filter version.

In order to convert the hood, a activated carbon filter (available as an accessory) is required. Follow the instructions for operating the hood to recirculate air.

When the temperature outdoors becomes more mild (spring), the filter can be removed and the hood converted once again for to extraction. Please consult the assembly instructions for operating the hood in extractor version.

71

Electrical connection

Safety warnings for the electrician

Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access.

Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board. To isolate the cooker hood from the mains, pull the mains plug. If the appliance is permanently connected to the mains, then it must be isolated from the mains using measures provided in the electrical installation (fuses -unscrew-type fuses, cut-out, current trips or similar that have a contact separation of >3mm when open).

The manufacture declines all responsibility for malfunctions resulting from failure to comply with the above instructions.

If the power socket is applied directly above the hood this gives two advantages:

1.The socket is not visible.

2.The appliance can be disconnected at need merely be removing the plug.

Electrical connection

220-230 V – by means of fixed power cable with plug.

(Fixed connection of the appliance must only be carried out by an authorised electrician.)

72

Technical Details

Dimensions :

 

Height x Width x Depth (in cm)

13 x 59,9 x 51

Weight:

 

Net:

8,7 kg

Gross:

9,7 kg

Maximum absorbed power:

330 W

Motor absorption:

2 x 125 W

Lighting:

2 x 40 W

Length of the cable:

110 cm

Fan powers (speed), speed in compliance with DIN 44971

(Extractor version) Speed:

 

min.

131 m3/h

max.

251 m3/h

intensive

360 m3/h

(Filter version) Speed:

 

min.

50 m3/h

max.

125 m3/h

intensive

140 m3/h

Flange 120 mm Ø