Prior to starting any work, read the operating instructions! Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen! Zum späteren Gebrauch aufbewahren!
2
Operating instructions level sensor, model FLR
Contents
Contents
1. General information 4
2. Design and function 5
3. Safety 6
4. Transport, packaging and storage 11
5. Commissioning, operation 13
6. Faults 15
7. Maintenance and cleaning 16
8. Dismounting, return and disposal 17
9. Specifications 18
Appendix 1: EU declaration of conformity 35
Declarations of conformity can be found online at www.wika.com.
EN
017461.02 10/2016 EN/DE
3Operating instructions level sensor, model FLR
1. General information
1. General information
The level sensors described in the operating instructions have been designed and manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria during production. Our management systems are certified to ISO 9001.
EN
These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the instrument’s range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and readily accessible to skilled personnel at any time. Pass the operating instructions on to the next operator or owner of the instrument.
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
The general terms and conditions contained in the sales documenta­tion shall apply.
Subject to technical modifications.
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: LM 20.02
4
Operating instructions level sensor, model FLR
017461.02 10/2016 EN/DE
2. Design and function
2. Design and function
2.1 Functional description
Level sensors work on the float principle with magnetic transmission. A permanent magnet built into the float triggers, with its magnetic field, the resistance measuring chain built into the guide tube. The entire assembly corresponds to a 3-wire potentiometer circuit. The float changes its height with the level of the medium it is monitoring. The measured resistance signal is proportional to the level. The measure­ment voltage is very finely-stepped due to the contact separation of the resistance measuring chain and is thus virtually continuous.
Connection housing
   
≤ 30°
Cable gland
Spanner flats for screwing in
Sealing
Guide tube
Float
Teflon disc
Float stop
EN
2.2 Scope of delivery
Cross-check scope of delivery with delivery note.
017461.02 10/2016 EN/DE
5Operating instructions level sensor, model FLR
2. Design and function / 3. Safety
3. Safety
3.1 Explanation of symbols
DANGER!
EN
3.2 Intended use
Level sensors are used exclusively for monitoring the levels of liquid media. The scope of application is defined by the technical performance limits and materials.
... indicates a directly dangerous situation resulting in serious injury or death, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to equipment or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for efficient and trouble-free operation.
6
Operating instructions level sensor, model FLR
017461.02 10/2016 EN/DE
3. Safety
The liquids must not have any large contamination or coarse particulates and must not have a tendency to crystallise. Ensure that the wetted materials of the level sensor are sufficiently resistant to the medium being monitored. Not suitable for dispersions, abrasive liquids, highly viscous media and colours.
This instrument is not permitted to be used in hazardous areas! For these areas, level sensors with approval (e.g. in accordance with ATEX) are required.
The operating conditions specified in the operating instructions must be observed.
Do not operate the instrument in the direct vicinity of ferromagnetic environments (min. distance 50 mm).
Do not operate the instrument in the immediate vicinity of strong electromagnetic fields or in the immediate vicinity of equipment that can be affected by magnetic fields (min. clearance 1 m).
The level sensors must not be exposed to heavy mechanical strain (impact, bending, vibration).
The technical specifications contained in these operating instructions must be observed. Improper handling or operation of the instrument outside of its technical specifications requires the instrument to be taken out of service immediately and inspected by an authorised WIKA service engineer.
EN
The instrument has been designed and built solely for the intended use described here, and may only be used accordingly.
017461.02 10/2016 EN/DE
7Operating instructions level sensor, model FLR
3. Safety
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
DANGER!
Work on vessels involves the danger of intoxication and
EN
3.3 Improper use
Improper use is defined as any application that exceeds the technical performance limits or is not compatible with the materials.
Any use beyond or different to the intended use is considered as improper use.
Do not use this instrument in safety or emergency stop devices.
3.4 Responsibility of the operator
The instrument is used in the industrial sector. The operator is therefore responsible for legal obligations regarding safety at work.
suffocation. No work is allowed to be carried out unless by taking suitable personal protective measures (e.g. respirato­ry protection apparatus, protective outfit etc.).
WARNING! Injuries through improper use
Improper use of the instrument can lead to hazardous situa­tions and injuries.
Refrain from unauthorised modifications to the instru­ment.
Do not use the instrument within hazardous areas.
The safety instructions within these operating instructions, as well as the safety, accident prevention and environmental protection regulations for the application area must be maintained.
8
Operating instructions level sensor, model FLR
017461.02 10/2016 EN/DE
3. Safety
To ensure safe working on the instrument, the operating company must ensure the following:
The operating personnel are regularly instructed in all topics regard­ing work safety, first aid and environmental protection and know the operating instructions and in particular, the safety instructions contained therein.
The operating personnel have read the operating instructions and taken note of the safety instructions contained therein.
The intended use for the application is complied with.
Following testing, improper use of the instrument is excluded.
3.5 Personnel qualification
WARNING! Risk of injury should qualification be insufficient
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled personnel who have the qualifications described below.
Skilled personnel
Skilled personnel, authorised by the operator, are understood to be personnel who, based on their technical training, knowledge of measurement and control technology and on their experience and knowledge of country-specific regulations, current standards and direc­tives, are capable of carrying out the work described and independently recognising potential hazards.
EN
3.6 Personal protective equipment
The personal protective equipment is designed to protect the skilled personnel from hazards that could impair their safety or health during work. When carrying out the various tasks on and with the instrument, the skilled personnel must wear personal protective equipment.
017461.02 10/2016 EN/DE
9Operating instructions level sensor, model FLR
3. Safety
Follow the instructions displayed in the work area regarding personal protective equipment!
The requisite personal protective equipment must be provided by the operating company.
EN
3.7 Labelling, safety marks
Product label
        
Model designation / model
Instrument code
Circuit diagram with colour coding per IEC 757
Serial number
Article number
Measuring point number
Ingress protection per EN/IEC 60529
Symbol of protection class per EN 61140
Switching power
Before mounting and commissioning the instrument, ensure you read the operating instructions!
10
Operating instructions level sensor, model FLR
017461.02 10/2016 EN/DE
4. Transport ... / 5. Commissioning, operation
4. Transport, packaging and storage
4.1 Transport
Check the level sensor for any damage that may have been caused by transport. Obvious damage must be reported immediately.
CAUTION!
With improper transport, a high level of damage to property can occur.
Observe the symbols on the packaging
Handle packed goods with care
4.2 Packaging and storage
Do not remove packaging until just before commissioning. Keep the packaging as it will provide optimum protection during trans­port (e.g. change in installation site, sending for repair).
5. Commissioning, operation
Observe all instructions given on the shipment packaging for remov­ing the transportation safety devices.
Remove the level sensor carefully from the packaging!
When unpacking, check all components for any external damage.
5.1 Functional check
Prior to installation, a functional test of the level sensor can be carried out with a resistance measuring instrument and manual movement of the float.