Whirlpool WVW53UC0FS, WVW53UC6FS Installation Manual

0 (0)

30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNT

CANOPY RANGE HOOD

Installation Instructions and Use & Care Guide

For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com

In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca

HOTTE DE CUISINIÈRE À MONTAGE MURAL

DE 30" ET 36" (76,2 ET 91,4 CM)

Instructions d’installation et Guide d’utilisation et d’entretien

Au Canada, pour assistance, installation ou service, composer le 1-800-807-6777 ou visiter notre site Web à www.whirlpool.ca

Table of Contents/Table des matières......................................

2

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.

FOR RESIDENTIAL USE ONLY.

IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.

POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.

LIB0114550A/W10836364B

TABLE OF CONTENTS

 

RANGE HOOD SAFETY..................................................................

2

INSTALLATION REQUIREMENTS.................................................

4

Tools and Parts.............................................................................

4

Location Requirements.................................................................

4

Venting Requirements...................................................................

5

Electrical Requirements................................................................

6

INSTALLATION INSTRUCTIONS...................................................

7

Prepare Location...........................................................................

7

Install Range Hood.......................................................................

8

Connect Vent System...................................................................

8

Make Electrical Connection..........................................................

9

Install Vent Covers......................................................................

10

Complete Installation..................................................................

10

RANGE HOOD USE......................................................................

11

Range Hood Controls.................................................................

11

RANGE HOOD CARE....................................................................

12

Cleaning......................................................................................

12

WIRING DIAGRAM........................................................................

13

ASSISTANCE OR SERVICE..........................................................

14

In the U.S.A.................................................................................

14

In Canada....................................................................................

14

Accessories.................................................................................

14

WARRANTY...................................................................................

15

TABLE DES MATIÈRES

 

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE................................

16

EXIGENCES D’INSTALLATION....................................................

18

Outils et pièces...........................................................................

18

Exigences d’emplacement.........................................................

18

Exigences concernant l’évacuation............................................

19

Spécifications électriques...........................................................

21

INSTRUCTIONS D’INSTALLATION.............................................

22

Préparation de l’emplacement...................................................

22

Installation de la hotte.................................................................

23

Raccordement du circuit d’évacuation......................................

23

Raccordement électrique...........................................................

24

Installation des cache-conduits..................................................

25

Achever l’installation...................................................................

25

UTILISATION DE LA HOTTE........................................................

26

Commandes de la hotte de cuisinière........................................

26

ENTRETIEN DE LA HOTTE..........................................................

27

Nettoyage....................................................................................

27

SCHÉMA DE CÂBLAGE...............................................................

28

ASSISTANCE OU SERVICE..........................................................

29

Au Canada..................................................................................

29

Accessoires.................................................................................

29

GARANTIE.....................................................................................

30

RANGE HOOD SAFETY

Your safety and the safety of others are very important.

many important safety messages in this manual and on your appliance. Always read and obey all safety

safety alert symbol.

alerts you to potential hazards that can kill or hurt you and others.

messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” mean:

DANGER WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

State of California Proposition 65 Warnings:

WARNING: This product contains one or more chemicals known to the State of California to cause cancer.

WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.

2

Whirlpool WVW53UC0FS, WVW53UC6FS Installation Manual

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

3

4 - 10 x 60 mm wall anchors
Hood canopy assembly with blower and LED lights installed Vent transition with back draft dampers installed
Vent cover support bracket Metal grease filter(s) Mounting template 2-piece vent cover
2 - 2.9 x 6.5 mm screws (Phillips)

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools Needed

■■ Level

■■ Drill with 11/4" (3 cm), 3/8" (9.5 mm), and 3/16" (4.8 mm) drill bits

■■ Pencil

■■ Wire stripper or utility knife ■■ Tape measure or ruler

■■ Pliers

■■ Caulking gun and weatherproof caulking compound ■■ Vent clamps

■■ Jigsaw or keyhole saw ■■ Flat-blade screwdriver ■■ Metal snips

■■ Phillips screwdriver

Parts Needed

■■

Home power supply cable

■■

1/2" (12.7 mm) UL listed or CSA approved strain relief

■■ 3 UL listed wire connectors

For Vented Installations, You Will Also Need:

■■ 1 wall or roof cap

■■ Metal vent system

For Non-Vented (Recirculating) Installations, You Will Also Need:

■■ Recirculation Kit Part Number W10349327 for non-vented (recirculating) installations only. See “Assistance or Service” section to order.

■■ 6" (15.2 cm) diameter round metal vent duct - length required is determined by ceiling height.

Parts Supplied

Remove parts from packages. Check that all parts are included.

■■

■■

■■

■■

■■

■■

■■

■■ 2 - 3.5 x 9.5 mm screws (Phillips)

■■ 6 - 5 x 45 mm mounting screws (#2 Phillips)

■■ 4 - 5.4 x 75 mm screws (Phillips) (for 10 x 60 mm wall anchors)

■■ 2 - 8 x 40 mm wall anchors (masonry)

■■

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the installer’s responsibility to comply with installation clearances specified on the model/serial/rating plate. The model/serial/ rating plate is located behind the left filter on the rear wall

of the vent hood.

Canopy hood location should be away from strong draft areas, such as windows, doors, and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.

This range hood is recommended for use with cooktops with a maximum total rating of 60,000 BTUs or less.

Grounded electrical outlet is required. See “Electrical Requirements” section.

The canopy hood is factory set for venting through the roof or wall. For non-vented (recirculating) installation, see “For nonvented (recirculating) installation only” in the “Connect Vent System” section. Recirculation Kit Part Number W10349327 is available from your dealer or an authorized parts distributor.

All openings in ceiling and wall where canopy hood will be installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280)

or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Product Dimensions

10" (25.4 cm)

30" (76.2 cm) or

20" (50.8 cm)

36" (91.4 cm)

 

*For non-vented (recirculating) installations

**For vented installations

4

Cabinet Dimensions

2" (5.1 cm) min. 6" (15.2 cm) min.*

Vent and power supply cable entry location

 

 

 

 

 

 

15" (38.1 cm)

Side

 

 

 

 

 

Side

cabinet

 

 

 

 

 

cabinet

 

 

 

 

30"

(76.2 cm) or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36"

(91.4 cm)

 

 

 

 

 

 

 

 

 

 

 

“X” bottom of canopy to cooking surface

Centerline

Cooking surface

* For non-vented (recirculating) installations

IMPORTANT:

Minimum distance “X”: 24" (61 cm) from electric cooking surface

Minimum distance “X”: 27" (68.6 cm) from gas cooking surface

Suggested maximum distance “X”: 36" (91.4 cm)

The chimneys can be adjusted for different ceiling heights. See the following chart.

Vented Installations

 

Min. ceiling height

Max. ceiling height

 

 

 

Electric cooking

7' 5" (2.26 m)

9' 2" (2.79 m)

surface

 

 

Gas cooking

7' 8" (2.34 m)

9' 2" (2.79 m)

surface

 

 

Non-Vented (Recirculating) Installations

 

 

 

 

Min. ceiling height

Max. ceiling height

 

 

 

Electric cooking

7' 5" (2.26 m)

9' 6" (2.9 m)

surface

 

 

Gas cooking

7' 8" (2.34 m)

9' 6" (2.9 m)

surface

 

 

NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights, depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number EXTKIT18FS is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.

Venting Requirements

(vented models only)

■■ Vent system must terminate to the outdoors except for non-vented (recirculating) installations.

■■ Do not terminate the vent system in an attic or other enclosed area.

■■ Do not use 4" (10.2 cm) laundry-type wall cap.

■■ Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

■■ The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the Most Efficient and Quiet Operation:

■■ Use no more than three 90° elbows.

■■ Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

■■ Do not install 2 elbows together.

■■ Use clamps to seal all joints in the vent system.

■■ The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood.

■■ Use caulking to seal exterior wall or roof opening around the cap.

■■ The size of the vent should be uniform.

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Venting Methods

This canopy hood is factory set for venting through the roof or wall.

A 6" (15.2 cm) round vent system is needed for installation

(not included). The hood exhaust opening is 6" (15.2 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

Rear Discharge

A 90° elbow may be installed immediately above the hood.

5

For Non-Vented (Recirculating) Installations

If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Fumes and vapors are recycled through the top grille. See the “Assistance or Service” section for information on ordering.

 

 

Non-Vented

Roof Venting

Wall Venting

(Recirculating)

A

 

A

 

 

B

B

 

B

 

A

A. Roof cap

A. Wall cap

A. Deflector

B. 6" (15.2 cm)

B. 6" (15.2 cm)

B. 6" (15.2 cm)

round vent

round vent

round vent

 

 

 

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

 

 

45° elbow

2.5 ft (0.8 m)

90° elbow

5 ft (1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

Example Vent System

90 Elbow

 

 

 

 

 

 

Wall cap

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft

(0.6 m)

The following example falls within the maximum recommended vent length of 35 ft (10.7 m).

1

- 90° Elbow

= 5 ft (1.5 m)

1

- Wall cap

= 0 ft (0 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

 

 

Length of system

= 13 ft (3.9 m)

Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition) or CSA Standards C22.1-94, Canadian

Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition), and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

■■ A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

■■ If the house has aluminum wiring, follow the procedure below:

1.Connect a section of solid copper wire to the pigtail leads.

2.Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools

designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer’s recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

■■ Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial/rating plate. The model/serial/rating plate is located behind the left filter on the rear wall of the range hood.

■■ Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1

and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

6

INSTALLATION INSTRUCTIONS

Prepare Location

■■ It is recommended that the vent system be installed before hood is installed.

■■ Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

■■ Check your ceiling height and the hood height maximum before you select your hood.

1.Disconnect power.

2.Determine which venting method to use: roof, wall, or non-vented.

3.Select a flat surface for assembling the range hood. Place covering over that surface.

WARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.

Failure to do so can result in back or other injury.

4.Using 2 or more people, lift range hood onto covered surface.

5.Remove wood base from range hood and dispose of properly.

Range Hood Mounting Screws Installation

1.Determine and mark the centerline on the wall where the canopy hood will be installed.

2.Select a mounting height between a minimum of 24" (61 cm) for an electric cooking surface, a minimum of 27" (68.6 cm) for a gas cooking surface, and a suggested maximum of 36" (91.4 cm) above the range to the bottom of the hood. Mark a reference line on the wall.

3.Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall.

A

DRILL 2 (TWO) 3/16" PILOT HOLES THROUGH STUDS OR REAR WALL SUPPORT

Centerlin Vertical

REAR WALL

MOUNTING TEMPLATE

CL

ALIGN BOTTOM EDGE

WITH PENCIL LINE

INDICATING BOTTOM

OF THE HOOD

Installation Height

Horizontal Line

B C

A.Centerline

B.Fastener locations

C.Mounting height reference (hood bottom line)

4.Mark centers of the fastener locations through the template to the wall.

IMPORTANT: All canopy mounting screws must be installed into wood where possible. If there is no wood to screw into, additional wall framing supports may be required or use

the (4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws. Remove the template.

5.For wood, drill 3/16" (4.8 mm) pilot holes at all locations where screws are being installed into wood.

For wall anchors, drill 7/16" (10 mm) holes at all locations where wall anchors are being used.

6.For wood, install (2) 5 x 45 mm mounting screws. Leave a 1/4" (6.4 mm) gap between the wall and the back of the screw head to slide range hood into place.

For wall anchors, install the 10 x 60 mm wall anchors and install the 5.4 x 75 mm screws into the wall anchors.

Tighten until the wall anchors are secure. Back the screws out 1/4" (6.4 mm).

¹⁄" (6.4 mm)

Vent Cover Support Bracket Installation

Installations using telescoping upper and lower vent cover assembly

1.Position vent cover bracket on wall about 1/8" (3 mm) away from the ceiling.

2.Mark the hole locations.

3.Drill (2) 3/8" (9.5 mm) holes for 8 x 40 mm wall anchors and insert anchors flush with the wall.

A C

B

D

A.8 x 40 mm wall anchors

B.Centerline on wall

C.Vent cover support bracket

D.5 x 45 mm screws

4.Attach vent cover support bracket to wall.

Complete Preparation

1.Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the hood. See “Venting Requirements” section.

2.Determine the required height for the home power supply cable and drill a 11/4" (3.2 cm) hole at this location.

3.Run the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough 1/2" conduit and wires from the fused disconnect (or circuit breaker) box to make the connection in the hood’s electrical terminal box.

NOTE: Do not reconnect power until installation is complete.

4.Use caulk to seal all openings.

7

Install Range Hood

NOTE: Remove protective film from range hood and metal filters.

1.Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood.

A

B

C

A.Mounting screws

B.Mounting slots

C.Lower mounting screws

2.Remove the grease filter. See “Range Hood Care” section.

3.Level the range hood and tighten upper mounting screws.

4.Install (2) 5 x 45 mm lower mounting screws and tighten. Use the optional wall anchors if needed.

ConnectVent System

1.Install transition on top of hood (if removed for shipping) with (2) 3.5 x 9.5 mm sheet metal screws.

A

B

A.Vent transition

B.3.5 x 9.5 mm screw

For vented installations only:

1.Fit vent system over transition piece.

2.Seal connection with clamps.

3.Check that back draft dampers work properly.

For non-vented (recirculating) installation only:

1.Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the Recirculation Kit.

B A

B

C

A.Vent cover bracket

B.Assembly screws

C.Deflector

2.Measure from the bottom of the air deflector to the bottom of the hood outlet.

 

 

A

B

 

 

D

X

C

 

 

E

 

 

A.Air deflector

B.Vent clamp

C.X = length to cut vent duct

D.Vent duct

E.Exhaust outlet

3.Cut the duct to the measured size “X.”

4.Remove the air deflector.

5.Slide the duct onto the bottom of the air deflector.

6.Place the assembled air deflector and duct over the exhaust outlet from the hood.

7.Reassemble the air deflector to the duct cover bracket with the 2 assembly screws.

8.Seal connections with vent clamps.

8

Make Electrical Connection

WARNING

Electrical Shock Hazard Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Remove terminal box cover.

3.Remove the knockout in the terminal box and install a UL listed or CSA approved 1/2" strain relief.

4.Run home power supply wiring through 1/2" strain relief into terminal box.

E

D

C

B

A

A UL listed wire connectors

B.White wires

C.Black wires

D.Green (or bare) wire connected to yellow-green wires

E.Home power supply

5.Use UL listed wire connectors and connect white wires (B) together.

6.Use UL listed wire connectors and connect black wires (C) together.

WARNING

Electrical Shock Hazard Electrically ground blower.

Connect ground wire to green and yellow ground wire in terminal box.

Failure to do so can result in death or electrical shock.

7.Connect green (or bare) ground wire from home power supply to the 2 yellow-green ground wires (D) in terminal box using UL listed wire connectors.

8.Tighten strain relief screw.

9.Install terminal box cover.

10.Reconnect power.

9

B
A. Upper vent cover B. Lower vent cover
C. 2.9 x 6.5 mm screws D. Bracket
NOTE: For vented installations, the upper vent cover may be reversed to hide slots.
C
A
InstallVent Covers
NOTE: Remove protective film from the vent covers.
1. When using both upper and lower vent covers, push lower cover down onto hood and lift upper cover to ceiling and install with (2) 2.9 x 6.5 mm screws.
D
C

Complete Installation

1.For non-vented (recirculating) installations only, install charcoal filters over the grease filters, using the clips provided in the kit. See the “Range Hood Care” section.

2.Install metal filters. See the “Range Hood Care” section.

3.Check the operation of the range hood blower and light. See the “Range Hood Use” section.

NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.

10