Whirlpool YWED8000DW4, YMEDB855DW3, YMEDB855DC3, MEDB835DC4, MGDB835DW4 Installation Guide

...
0 (0)

Gas and Electric Dryer

Instructions d’installation –

Installation Instructions

Sécheuse à gaz et électrique

 

 

Table of Contents

Table des matières

DRYER SAFETY.................................................................

2

INSTALLATION REQUIREMENTS....................................

4

Tools and Parts....................................................................

4

LOCATION REQUIREMENTS.....................................................

5

Installation Clearances........................................................

5

Dryer Dimensions................................................................

5

ELECTRICAL REQUIREMENTS - U.S.A. ONLY.........................

6

Grounding Instructions........................................................

7

ELECTRIC DRYER POWER HOOKUP - CANADA ONLY..........

7

Electrical Requirements......................................................

7

Grounding Instructions........................................................

7

GAS DRYER POWER HOOKUP - U.S.A. AND CANADA...........

8

Electrical Requirements......................................................

8

Grounding Instructions........................................................

8

Gas Supply Requirements...................................................

8

Gas Type...............................................................................

8

Gas Supply Line...................................................................

8

Gas Supply Connection Requirements..............................

9

Burner Input Requirements................................................

9

Dryer Gas Pipe.....................................................................

9

INSTALL LEVELING LEGS..........................................................

9

MAKE ELECTRICAL CONNECTION - U.S.A. ONLY................

10

Electrical Connection........................................................

10

Power Supply Cord Connection.......................................

10

Direct Wire Connection.....................................................

12

MAKE GAS CONNECTION - U.S.A. AND CANADA................

16

VENTING....................................................................................

16

Venting Requirements.......................................................

16

Plan Vent System...............................................................

17

Install Vent System............................................................

18

CONNECT INLET HOSES.........................................................

18

CONNECT VENT........................................................................

20

LEVEL DRYER...........................................................................

20

COMPLETE INSTALLATION CHECKLIST................................

21

REVERSE DOOR SWING..........................................................

22

SÉCURITÉ DE LA SÉCHEUSE.........................................

26

EXIGENCES D’INSTALLATION........................................

28

Outillage et pièces..............................................................

28

EXIGENCES D’EMPLACEMENT................................................

29

Distances de dégagement à respecter pour

 

l’installation.........................................................................

 29

Dimensions de la sécheuse...............................................

29

RACCORDEMENT DE LA SÉCHEUSE

 

ÉLECTRIQUE – CANADA SEULEMENT....................................

30

Spécifications électriques..................................................

30

Instructions de liaison à la terre........................................

31

RACCORDEMENT ÉLECTRIQUE DE LA SÉCHEUSE

 

À GAZ - ÉTATS-UNIS ET CANADA............................................

31

Spécifications électriques..................................................

31

Instructions de liaison à la terre........................................

31

Spécifications de l’alimentation en gaz............................

32

Type de gaz..........................................................................

32

Canalisation de gaz............................................................

32

Spécifications du raccordement de

 

l’alimentation en gaz..........................................................

33

Spécifications de l’alimentation du brûleur......................

33

INSTALLATION DES PIEDS DE NIVELLEMENT.......................

33

RACCORDEMENT AU GAZ - ÉTATS-UNIS ET CANADA.........

34

L’EVACUATION...........................................................................

34

Exigences concernant l’evacuation..................................

34

Planification des circuits de conduits...............................

35

Installation du système d’évacuation...............................

36

RACCORDEMENT DES TUYAUX D’ALIMENTATION...............

37

RACCORDEMENT DU SYSTÈME D’ÉVACUATION..................

38

ÉTABLIR L’APLOMB DE LA SÉCHEUSE..................................

39

ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION ..........

39

INVERSION DU SENS D’OUVERTURE DE LA PORTE............

40

Para obtener acceso al “Instrucciones de instalación” en español, o para obtener información adicional acerca de su producto, visite: www.whirlpool.com

Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la puerta.

INSTALLATION NOTES

NOTES CONCERNANT L’INSTALLATION

Date of purchase: _________________________________

Date d’achat : _____________________________________

Date of installation:_ _______________________________

Date d’installation :_ ________________________________

Installer: ________________________________________

Installateur : _ _____________________________________

Model number: ___________________________________

Numéro de modèle : ________________________________

Serial number:____________________________________

Numéro de série : __________________________________

 

 

 

W11101355A W11101358A-SP

Whirlpool YWED8000DW4, YMEDB855DW3, YMEDB855DC3, MEDB835DC4, MGDB835DW4 Installation Guide

DRYER SAFETY

2

WARNING:

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building, or area of all occupants.

Immediatelyinstructions. call your gas supplier from a neighbor’s phone. Follow the gas supplier’s

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by the State of Massachusetts.

Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.

A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).

3

INSTALLATION REQUIREMENTS

TOOLS AND PARTS

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed for all installations:

 

 

 

Flat-blade screwdriver

 

Adjustable wrench that

 

 

opens to 1" (25 mm) or

 

 

hex-head socket wrench

 

 

 

 

 

 

Tools needed for gas installations:

8" (203 mm) or 10"

8" (203 mm) or 10"

(254 mm) pipe wrench

(254 mm) adjustable wrench

 

(for gas connections)

 

 

 

 

Pipe-joint compound resistant to propane gas

Parts supplied (all models):

Level

 

Vent clamps

 

 

 

 

 

 

Plastic putty knife

Caulking gun and compound

 

 

(for installing new exhaust vent)

Leveling legs (4)

Parts package is located in dryer drum. Check that all parts are included.

Parts needed (steam models):

Tin snips (new vent installations)

#2 Phillips screwdriver

Tape measure

1/4" ( 6 mm) nut driver (recommended)

Wire stripper (direct wire installations)

Pliers

“Y” connector

Short inlet hose

Rubber washer (4)

 

 

 

 

 

 

 

 

Inlet hose

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with clothes dryers. The kit should contain:

■■ A UL Listed 30-amp power supply cord, rated 120/240 volt minimum, with a temperature rating of 140°F (60°C) minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to

the dryer must end in ring terminals or spade terminals with upturned ends.

■■ A UL Listed strain relief.

4

Parts needed: (Not supplied with dryer)

Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the “Assistance or Service” section in your “Use and Care Guide.”

Enhance your new washer and dryer with the following genuine Whirlpool accessories. For more information on options and ordering, call 1-866-698-2538, or visit us at: www.whirlpool.com/accessories. In Canada, call 1-800-688-2002 or visit us at www.whirlpoolparts.ca.

LOCATION REQUIREMENTS

INSTALLATION CLEARANCES

For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

DRYER DIMENSIONS

 

561/4"

Door Opened

 

 

 

(1428 mm)

 

 

 

 

 

 

3213/16"

Door Closed

 

29"

 

 

(821 mm)

 

 

(737 mm)

 

 

 

 

 

 

 

 

 

4213/16"

 

 

 

57/8"

 

 

(1987 mm)

 

 

 

(150 mm)

 

 

 

 

 

 

41/2"

 

 

 

 

 

 

(115 mm)

1"

113/8"

35/8"

3"

13/8"

141/2"

31/2"

(25 mm)

(289 mm)(93 mm)

(77 mm)

(35 mm) (370 mm)

(93 mm)

 

Side view

 

 

Back view

 

Bottom view:

You will need:

■■ A location allowing for proper exhaust installation. See “Venting Requirements.”

■■ A separate 15or 20-amp circuit needed for gas dryers and 30-amp circuit needed for electric dryers.

■■ If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”

■■ Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance.

■■ Level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), clothes may not tumble properly and automatic sensor cycles may not operate correctly.

■■ For garage installation, place dryer at least 18" (460 mm) above floor.

■■ Steam models only: Cold water faucets located within

4 ft. (1.2 m) of the water fill valves, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use your washer’s water supply by purchasing the necessary parts noted in “Parts needed.”

IMPORTANT: Do not operate, install, or store dryer where

it will be exposed to water, weather, or at temperatures below 45°F (7°C). Lower temperatures may cause dryer not to

shut off at end of automatic sensor cycles, resulting in longer drying times.

NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.

81/2"

(218 mm)

143/8"

(365 mm)

NOTE: Most installations require a minimum of 6" (152 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”

5

Spacing for recessed area or closet installation

The dimensions shown are for the recommended spacing allowed.

■■ Additional spacing should be considered for ease of installation and servicing.

■■ Additional clearances might be required for wall, door, and floor moldings.

■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.

■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilitation openings are acceptable.

■■ Companion appliance spacing should also be considered.

14" max (356 mm)

 

3"/3"

 

(76 mm) 48"2/48"2

18"/18"*

(310 cm2)

(457 mm)

 

24"2/24"2 3"/3" (155 cm2)

(76 mm)

6"/0"

 

(152 mm/0 mm)

1"/1"

 

(25 mm)

1"/0"

 

(25 mm/0 mm)

 

*Recommended/Minimum spacing

Mobile home - Additional installation requirements:

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR,

Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

All dryers:

■■ Metal exhaust system hardware, available for purchase from your dealer. For further information, see “Assistance or Service” section in your “Use and Care Guide.”

■■ Special provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.

For gas dryers mobile home installations:

■■ Mobile Home Installation Hold-down Kit Part Number W10432680 is available to order. For further information, see “Assistance or Service” section in your “Use and Care Guide.”

ELECTRICAL REQUIREMENTS - U.S.A. ONLY (SPÉCIFICATIONS ÉLECTRIQUES – ÉTATS-UNIS SEULEMENT)

It is your responsibility:

■■ To contact a qualified electrical installer.

■■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition and all local codes and ordinances.

The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

■■ To supply the required 3- or 4-wire, single phase, 120/240 volt, 60 Hz, AC-only electrical supply (or 3- or 4-wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

■■ Do not use an extension cord.

■■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

■■ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

■■ If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.

■■ A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with clothes dryers. The kit should contain:

■■ A UL Listed 30-amp power supply cord, rated 120/240 volt minimum, with a temperature rating of 140°F (60°C) minimum. The cord should be type SRD or SRDT, and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

■■ A UL Listed strain relief.

6

If your outlet looks like this:

 

 

 

 

 

Then choose a 4-wire power supply cord with

 

 

 

 

 

ring or spade terminals and UL Listed strain

 

 

 

 

 

relief. The 4-wire power supply cord, at least

 

 

 

 

 

 

 

 

 

 

4 ft. (1.22 m) long, must have 4 10-gauge solid

 

 

 

 

 

 

 

 

 

 

copper wires and match a 4-wire receptacle of

 

4-wire

NEMA Type 14-30 R. The ground wire (ground

 

conductor) may be either green or bare. The

receptacle

neutral conductor must be identified by a

(14-30R)

white cover.

 

 

 

 

 

If your outlet looks like this:

Then choose a 3-wire power supply cord with ring or spade terminals and UL Listed strain relief. The 3-wire power supply cord, at least 4 ft. (1.22 m) long, must have 3 10-gauge solid copper wires and match a 3-wire receptacle of

NEMA Type 10-30R.

3-wire receptacle (10-30R)

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

■■ Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated.

■■ 10-gauge solid copper wire (do not use aluminum) at least 5 ft. (1.52 m) long.

ELECTRIC DRYER POWER HOOKUPCANADA ONLY

ELECTRICAL REQUIREMENTS

It is your responsibility:

■■ To contact a qualified electrical installer.

■■ To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

■■ To supply the required 4-wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

■■ This dryer is equipped with a UL listed and/or CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall receptacle

is within reach of dryer’s final location. 4-wire receptacle (14-30R)

For further information, please reference service numbers located in “Assistance or Service” section of your “Use and Care Guide.”

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.

SAVE THESE INSTRUCTIONS

7

GAS DRYER POWER HOOKUP - U.S.A. AND CANADA

ELECTRICAL REQUIREMENTS

■■ 120-Volt, 60 Hz, AC-only, 15or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.

SAVE THESE INSTRUCTIONS

GAS SUPPLY REQUIREMENTS

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line. Install a shut-off valve.

Securely tighten all gas connections.

If connected to propane, have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

GAS TYPE

Natural Gas:

This dryer is equipped for use with Natural gas. It is certified by UL for use with propane gas with appropriate conversion.

■■ Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your “Use and Care Guide.”

Propane Gas Conversion:

IMPORTANT: Conversion must be made by a qualified technician.

No attempt shall be made to convert the dryer from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.

GAS SUPPLY LINE

Option 1 (Recommended Method)

Flexible stainless steel gas connector:

■■ If local codes permit, use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer to the rigid

gas supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking.

Option 2 (Alternate Method)

Approved aluminum or copper tubing

■■ Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer.

■■ 1/2" IPS pipe is recommended.

■■ 3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.

■■ If you are using Natural gas, do not use copper tubing.

8