Whirlpool AMD 030 - 034 User Manual

501932602028:Layout 1 1-12-2008 16:58 Pagina 1
Gebrauchsanweisung
Instructions for use
Mode d’emploi
Gebruiksaanwijzing
Istruzioni per l’uso
Brugsanvisning
Bruksanvisning
Käyttöohje
Instrucciones para el uso
Instrukcje użytkowania
Használati utasítás
Инструкци
Я за употреба
Návod k použití
Návod na použitie
Instruc∑iuni de utilizare
Инструкции по эксплуатации
501932602028:Layout 1 1-12-2008 16:58 Pagina 2
3
ENGLISH Instructions for use Page 4
РУCCКИЙ
Инcтpyкции по экcплyaтaции Cтpaницa
27
501932602028:Layout 1 1-12-2008 16:58 Pagina 3
4
INSTRUCTIONS FOR USE
Page
BEFORE USING THE APPLIANCE 5
SAFETY PRECAUTIONS 5
AIR CONDITIONER PRECAUTIONS 6
SAFEGUARDING THE ENVIRONMENT 6
PRODUCT DESCRIPTION 7
CONTROL PANEL DISPLAY INDICATORS 8 DESCRIPTION
REMOTE CONTROL FUNCTIONS AND 9 INDICATORS
INDICATOR SYMBOLS ON RC DISPLAY 9
STORAGE AND TIPS FOR USING THE RC 10
OPERATING MODE DESCRIPTION 11
AIRFLOW DIRECTION CONTROL 12
MODE AND FUNCTION DESCRIPTIONS 13
MAINTENANCE 16
PROTECTION 16
TROUBLESHOOTING 17
INSTALLATION INSTRUCTIONS 18
INDOOR UNIT INSTALLATION 20
WIRING DIAGRAM 23
OUTDOOR UNIT INSTALLATION 25
AMD 030 - 031 - 032 - 033 - 034
501932602028:Layout 1 1-12-2008 16:58 Pagina 4
5
BEFORE USING THE APPLIANCE
To make the most out of your new appliance, please read the user instructions carefully and keep them handy for future consultation.
Before using the appliance please follow and set according to the below indications: Remote Control (RC) presetting:
Each time the batteries are replaced in the remote control, the RC is pre-set on Heat pump. If the air conditioner that you purchased is a cooling only, then the pre-set on Heat pump will not bring any changes.
Auto-Restart presetting Function:
To set the auto-restart function, press the Emergency button (ON/OFF) on the indoor unit for at least 5 seconds A buzz sound will signal that the auto-restart function is set and the air conditioner is in standby. To cancel the auto-restart function, repeat the above steps.
SAFETY PRECAUTIONS
• Do not install the appliance if it is connected to the power supply.
• The Installation and service/repair must be performed by a qualified technician, in compliance with the producer's instructions and following local safety norms. Do not repair or replace any parts of the appliance unless it is specifically written in the user instructions.
• The grounding of this appliance is compulsory.
• Make sure that the power supply cord is long enough to allow the right connection. Do not use any extension cord for power supply.
• Do not pull the power supply cord to remove it from the socket.
• Do not twist or press the power supply cord, and make sure it is not broken.
• Once installation is completed, the electric components must not be accessible to the users.
• Do not touch the operation buttons when your hands are wet and don't use the appliance when you are barefoot.
• Physically or mentally disabled people, children and people without any experience with the product are only allowed to use the appliance if they have had specific training on how to operate the appliance by a person responsible for their security and well-being. The appliance is not intended for use by disabled people and very young children without supervision.
501932602028:Layout 1 1-12-2008 16:58 Pagina 5
6
• This appliance has been made of recyclable or re-usable material. Scrapping must be carried out in compliance with local waste disposal regulations. Before scrapping it, make sure to cut off the mains cord so that the appliance cannot be re-used.
• For more detailed information on handling and recycling of this product, contact your local authorities who deal with the separate collection of rubbish or the shop where you bought the appliance.
SCRAPPING OF PACKAGING
• The packaging can be 100% recycled as confirmed by the recycling symbol . The various parts of the packaging must not be dispersed in the environment, but must be scrapped in line with local authority regulations.
SCRAPPING OF APPLIANCE
• This appliance is marked according to the European Directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE).
• By ensuring that this product is disposed of correctly, you will help to prevent potentially negative consequences for the environment and for human health.
• The symbol on the product or on the documents accompanying the product indicates that this appliance should not be treated as household waste, but must be given to the appropriate local gathering place where electric and electronic appliances are stored and recycled.
SAFEGUARDING THE ENVIRONMENT
AIR CONDITIONER PRECAUTIONS
Please strictly follow the below instructions:
• Long and direct exposure to cool air might be harmful to health. It is advisable to set the louvers in order to avoid direct cool air and deflect it within the room.
• Prevent the air flow from reaching the gas burners and stoves.
• Upon malfunctioning first turn the appliance off by pressing the ON/OFF button on the remote control, then disconnect it from the mains.
• Do not place any objects on the outdoor unit.
• This product contains Fluorinated Greenhouse Gases covered by the Kyoto Protocol, the refrigerant gas being in a hermetically sealed system. Refrigerant gas: R410a has a GlobalWarming Potential (GWP) 1975.
501932602028:Layout 1 1-12-2008 16:59 Pagina 6
7
PRODUCT DESCRIPTION
Indoor unit
1. Air Intake
2. Front Panel
3. Display panel
4. Air Outlet
5. Electrical box
6. Filter monitor reset button
7. Vertical Adjustment Louver
8. Horizontal Adjustment Louver
9. Air Filter
10. Remote Control
Outdoor unit
11. Air Intake
12. Pipes and Power Connection Cord
13. Drain Hose
Note: Condensate water drains at COOLING
or DRY operation.
14. Air Outlet
Images in the user instructions are based on external views of standard models, shape and design vary according to the model.
501932602028:Layout 1 1-12-2008 16:59 Pagina 7
ON
OFF
8
CONTROL PANEL DISPLAY INDICATORS DESCRIPTION
Temperature indicator (1)
Displays set or room temperature.
Running indicator (2)
It lights up during operation. It flashes during outside unit defrosting.
Timer indicator (3)
It lights up during the set time. It goes off when timer operation ends.
Sleep indicator (4)
It lights up during sleep mode.
Filter monitor indicator (5)
It flashes when the filter needs to be cleaned. Filter monitor indicator flashes after 240 hours of usage as reminder to clean the filter. After filter cleaning press the reset button located on the indoor unit behind the front panel in order to interrupt the flashing of the filter monitor indicator.
Emergency ON/OFF button (6)
Used to control the unit by pressing the button, when the RC is out of work. Used to set or cancel auto-restart function.
501932602028:Layout 1 1-12-2008 16:59 Pagina 8
9
REMOTE CONTROL FUNCTIONS AND INDICATORS
1. ON/OFF BUTTON
Starts and/or Stops the appliance by pressing this button.
2. MODE BUTTON
Used to select the operation mode.
3. FAN BUTTON
Used to select fan speed in sequence auto, high, medium or low.
4-5. MODE BUTTON
Used to select the room temperature. Used to set time in timer mode and real time clock.
6. BUTTON
Sets or cancels 6th sense operation, also during stand-by.
7. SWING BUTTON
Stops or starts vertical adjustment louver swinging and sets the desired up/down airflow direction.
8. SLEEP BUTTON
Sets or cancels Sleep Mode operation.
9. BUTTON
When you press this button, the remote control transmit signal of the actual room temperature around it to the indoor unit every 10 minutes. Therefore please keep the remote controller in a location where it can transmit the signal to the indoor unit properly. Press once to set and press again to cancel.
10. CLOCK BUTTON
Used to set the current time.
11-12. TIMER BUTTON
Used to set or cancel the timer operation.
13. JET BUTTON
Used to start or stop the fast cooling. (Fast cooling operates at high fan speed with 18°C set temp. automatically).
U
INDICATOR SYMBOLS ON RC DISPLAY
Cooling indicator
Dry indicator
Fan only indicator
Heating indicator
Auto fan speed
High fan speed
Medium fan speed
Low fan speed
indicator
Sleep indicator
indicator
Jet indicator
Signal transmission
Display set timer Display current time
Display set temperature
U
501932602028:Layout 1 1-12-2008 17:00 Pagina 9
U
ON
OFF
4
3
13
12
11
10
1
2
6
7
5
8
9
U
OON
OFF
10
STORAGE AND TIPS FOR USING THE RC
How to Insert the Batteries
Remove the battery cover in the direction of the arrow. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Refit the cover by sliding it back into position.
Note:
• Use 2 LR03 AAA (1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the display becomes dim.
• If the replacement is done within 1 minute, the remote control will keep original presetting. However, if you replace batteries taking more than 3 minutes, all presetting will be cancelled and timer will display Zero.
The remote control may be stored in its holder (when available) mountable on the wall. To operate the air conditioner, point the remote control at the signal receptor. The remote control will operate the air conditioner at a distance of up to 7m.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Signal receptor
501932602028:Layout 1 1-12-2008 17:00 Pagina 10
ON
OF F
11
OPERATING MODE DESCRIPTION
Operation Modes:
1. Selecting mode
Each time MODE button is pressed, the operation mode is changed in sequence:
COOLING DRY FAN ONLY HEATING
Heating mode is not available for cooling only air conditioners.
2. FAN mode
Each time the "FAN" button is pressed, the fan speed is changed in sequence:
Auto High Medium Low
At "FAN ONLY" mode, only "High","Medium" and "Low" are available. At "DRY" mode, Fan speed is set at "Low" automatically, "FAN" button is ineffective in this case.
3. Setting temperature
Press once to raise temperature setting by 1 raise °C Press once to lower temperature setting by 1 lower °C
*Note: Heating mode is NOT available for cooling only models.
4. Turning on
Press button, when the appliance receives the signal, the RUNNING indicator of the indoor unit lights up.
During mode changes wait a few seconds and repeat the operation if the unit does not respond at once. When selection the heating operation, air flow will start after 2-5 minutes.
Range of available set temperature
*HEATING, COOLING 18°C~32°C
DRY unable to set
FAN ONLY unable to set
501932602028:Layout 1 1-12-2008 17:01 Pagina 11
2
ON
OFF
4
1
3
12
AIRFLOW DIRECTION CONTROL
5. Airflow direction control
Vertical airflow is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. The direction of airflow can be also adjusted to your own requirement by pressing the "SWING" button of the remote control.
*Heating mode is only available for heat pump models.
Vertical airflow control (using the remote control)
Use the remote control to set the flow angles.
Swinging airflow
Pressing "SWING" button once, the vertical adjustment louver will swing up and down automatically.
Desired direction airflow
Pressing the "SWING" button again when the louvers swing to a suitable angle as desired.
Horizontal airflow control (with hands) Turn the control rods of the horizontal adjustment louvers to change horizontal air flow as shown.
Note: The shape of the unit may look different from that of the air conditioner you have selected.
A - Do not turn the vertical adjustment louvers
manually, otherwise malfunction may occur. If that happens, turn off the unit first and cut off the power supply, then restore power supply again.
B - It is better not to let the vertical adjustment
louver tilt downward for a long time at COOLING or DRY mode to prevent condensed water from dripping.
Operation mode Direction of airflow
COOLING, DRY horizontal
*HEATING, FAN ONLY downward
control rod of horizontal adjustment louvers
501932602028:Layout 1 1-12-2008 17:01 Pagina 12
ON
OFF
5
13
MODE AND FUNCTION DESCRIPTIONS
6th SENSE MODE
Press the button, the unit enters 6th sense mode directly regardless of the unit is on or off. In this mode, temperature and fan speed are automatically set based on the actual room temperature.
Operation mode and temperature are determined by indoor temperature.
Heat pump models
Cooling only models
Button is ineffective in Jet mode.
Note: Temperature, airflow and direction are controlled automatically in 6th sense mode. However, a decrease or rise of up to 2°C can be set with the remote control if you still feel uncomfortable.
What you can do in 6th sense mode
Indoor
temperature
Operation
mode
Target
temperature
21°C or below HEATING 22°C
21°C-23°C FAN ONLY
23°C-26°C DRY
Room
temperature
decrease 1.5°C
after operating
for 3 minutes
Over 26°C COOLING 26°C
Indoor
temperature
Operation
mode
Target
temperature
26°C or below DRY
Room
temperature
decrease 1.5°C
after operating
for 3 minutes
Over 26°C COOLING 26°C
Your feeling button adjustment procedure
Uncomfortable because of unsuitable air flow volume.
Indoor fan speed alternates among High, Medium and Low each time this button is pressed.
Uncomfortable because of unsuitable flow direction.
Swing
Press it once, the vertical adjustment louver swings to change vertical airflow direction. Press it again, swings stops. For horizontal airflow direction please refer to the chapter "Airflow direction control".
501932602028:Layout 1 1-12-2008 17:01 Pagina 13
ON
OFF
FAN
14
Clock function
You can adjust the real time by pressing CLOCK button, then using and buttons to get the correct time, press CLOCK button again: the real time is set.
SLEEP mode SLEEP mode can be set in COOLING or HEATING operation mode.
This function gives you a more comfortable environment for sleep. In SLEEP mode,
• The appliance will stop operation automatically after operating for 8 hours.
• Fan speed is automatically set at low speed.
• Set temperature will rise by max 1°C if the appliance operates in cooling mode for 2 hours.
• Set temperature will decrease by 3°C at most if the appliance operates in heating mode for 3 hours.
*Note: In cooling mode, if room temperature is 26°C or above, set temperature will not change. Note: Heating is NOT available for cooling only air conditioner.
JET mode
• JET mode is used to start or stop fast cooling. Fast cooling operates at high fan speed, changing the set temperature automatically to 18°C.
JET mode can be set when the appliance is in operation.
•In JET mode, you can set airflow direction or timer. If you want to quit from JET mode, press any - JET , MODE, FAN, ON/OFF or TEMPERATURE SETTING button, the display will return to the original mode.
Note:
• SLEEP and 6th Sense buttons are not available in JET mode.
• JET button is ineffective in HEATING mode.
• The appliance will continue working in JET mode with set temperature of 18°C if you don't quit from it by pressing any of the buttons mentioned above.
501932602028:Layout 1 1-12-2008 17:02 Pagina 14
ON
15
Timer function
It is convenient to set the timer on by pressing the TIMER ON/OFF buttons to achieve a comfortable room temperature at the time you get home. You can also set timer off automatically to enjoy a good sleep at night.
How to set TIMER ON
TIMER ON button can be used to set the timer programming as wished in order to switch on the appliance at your desired time.
i) Press TIMER ON button, "ON 12:00" flashes on the LCD, then you can press the or buttons to select your desired time for appliance on.
Press the or button once to increase or decrease the time setting by 1 minute. Press the or button one and a half seconds to increase or decrease the time setting by 10 minutes. Press the or button for a longer time to increase or decrease the time by 1 hour. Note: If you don't see the time in 10 seconds after you press TIMER ON button, the remote control will exit the TIMER ON mode automatically.
ii) When your desired time displayed on LCD, press the TIMER ON button and confirm it. A "beep" can be heard". "ON" stops flashing. The TIMER indicator on the indoor unit lights up.
iii) After the time set displayed for 5 seconds the clock will be displayed on the LCD of the remote control instead of set timer.
How to cancel TIMER ON
Press the TIMER ON button again, a "beep" can be heard and the indicator disappears, the TIMER ON mode has been canceled. Note: It is similar to set the TIMER OFF, you can make the appliance switch off automatically at your desired time.
Increase
Decrease
501932602028:Layout 1 1-12-2008 17:02 Pagina 15
ON
16
MAINTENANCE
Unit
1. Unplug from the power supply
Turn off the appliance first before disconnecting from power supply.
2. To remove the front panel pull it outwards (Fig. A).
3. Wipe with a soft and dry cloth.
Use lukewarm water (below 40°C) to clean if the appliance is very dirty.
4. Never use substances such as gasoline or polishing powder to clean the appliance.
5. Never sprinkle water onto the indoor unit
Dangerous! Electric shock!
6. Refit and close the front panel (Fig. B).
Refit and close the front panel by pushing it downward.
Air filter
It is necessary to clean the air filter after using it for about 100 hours. Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment.
1. Unplug from the power supply
Turn off the appliance first before disconnecting from power supply and remove the air filter.
1. Open the front panel.
2. Press the handle of the filter gently.
3. Slide out the filter.
2. Cleaning and refitting the air filter.
If the filter is very dirty, clean it with a solution of lukewarm water and neutral detergent. After cleaning let it dry.
3. Close the front panel.
Fig. A
Fig. B
PROTECTION
Operating condition
The protective device maybe trip and stop the appliance in the cases listed below.
*For Tropical (T3) Climate condition models, the temperature point is 52°C instead of 43°C. If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80%, dew may drip down from the outlet.
Noise pollution
• Install the air conditioner at a place that can bear its weight in order to operate more quietly.
HEATING
Outdoor air temperature is over 24°C Outdoor air temperature is below -7°C Room temperature is over 27°C
COOLING
Outdoor air temperature is over *43°C Room temperature is below 21°C
DRY Room temperature is below 18°C
501932602028:Layout 1 1-12-2008 17:02 Pagina 16