Whirlpool AMB 892/G Service Manual

SERVICE
Model AMB 892/G Version 8528 892 10000 Page
Whirlpool Europe Customer Services
AMB 892/G
Service Manual
Technical data 2
Spare part list 3
Exploded view 4 - 5
Circuit and Wiring diagram 6
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 13.01.2004 (Mod. 02) Subject to modification Document-No.: 4812 731 16058
29.04.2003 / Page 2 AMB 892/G Whirlpool Europe Doc. No: 4812 731 16058 8528 892 10000 Customer Service
Technical data
SERVICE
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 890/980 mm Width 350/350 mm Depth 240/250 mm
Outdoor - unit
Height 1050 mm Width 910 mm Depth 500 mm
Weight
Indoor - unit 11 + 14 kg / net Outdoor - unit 79 kg / net
Electrical connection
Voltage 220 - 240 V Frequency 50 Hz Rated Current (Cooling) 10.7 A Rated Current (Heating) 10.5 A
Cooling Capacity
2637/3516 Watt 9000/12000 BTU / h
Heating Capacity
2812.8/3516 Watt 9600/12500 BTU / h
Airflow / Evaporator Airvolume
420/580 m3 / h
Dehumidifying Capacity
0.9/1.5 l / h
Noise Level
Indoor - unit 35 - 37 dB(A) Outdoor - unit 61 dB(A)
Energy Efficiency Rate (BTU/Watt hr)
Cooling 9.13 Heating 2.85
Compressor (cooling)
Type PG 165 X1C-4FT2 Capacity (CECOMAF) 2860 W
Type PG 225 X2C-4FT Capacity (CECOMAF) 3970 W
Refrigerant
Type R 407 C Quantity 1120/1220g
Loading...