Whirlpool AMB 877/G Service Manual

SERVICE
Model AMB 877/G Version 8528 877 10100 Page
Whirlpool Europe Customer Services
AMB 877/G
Service Manual
Air Conditioner Split Type AMB 877/G
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 20.03.2003 Subject to modification Document-No.: 4812 731 15432
20.03.2003 / Page 2 AMB 877/G Whirlpool Europe Doc. No: 4812 731 15432 8528 877 10100 Customer Service
Technical data
SERVICE
Factory Code AS-18HR4NR
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 1025 mm Width 313 mm Depth 203 mm
Outdoor - unit
Height 832 mm Width 702 mm Depth 380 mm
Weight
Indoor - unit 14 kg / net Outdoor - unit 54 kg / net
Cooling Capacity
5270 Watt 18000 BTU / h
Heating Capacity
5446 Watt 18600 BTU / h
Airflow / Evaporator Airvolume
750 m3 / h
Dehumidifying Capacity
2.4 l / h
Noise Level
Indoor - unit 39 - 44 dB(A) Outdoor - unit 54 dB(A)
Electrical connection
Voltage 220 - 240 V Frequency 50 Hz Rated Current (Cooling) 10.0 A Rated Current (Heating) 9.6 A
Energy Efficiency Rate (BTU/Watt hr)
Cooling 8.7 Heating 9.2
Compressor (cooling)
Type PG330X2C-4KV3 Capacity (CECOMAF) 5900 W
Refrigerant
Type R 407C Quantity 2020 g