Welch Allyn RPM-Scale100 Directions For Use Manual

Welch Allyn Remote Monitoring Scale RPM-Scale100
Directions for use
901077 Weight scale, Software Version 1.0
© 2015 Welch Allyn. All rights are reserved. To support the intended use of the product described in this publication, the purchaser of the product is permitted to copy this publication, for internal distribution only, from the media provided byWelch Allyn. No other use, reproduction, or distribution of this publication, or any part of it, is permitted without written permission from Welch Allyn.
Welch Allyn Remote Monitoring Scale is a trademark of Welch Allyn. Welch Allyn assumes no responsibility for any injury to anyone, or for any illegal or improper use of the
product, that may result from failure to use this product in accordance with the instructions, cautions, warnings, or statement of intended use published in this manual.
The
Bluetooth
®
word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc. and any
use of such marks by Welch Allyn is under license. Software in this product is Copyright 2015 Welch Allyn or its vendors. All rights are reserved. The
software is protected by United States of America copyright laws and international treaty provisions applicable worldwide. Under such laws, the licensee is entitled to use the copy of the software incorporated with this instrument as intended in the operation of the product in which it is embedded. The software may not be copied, decompiled, reverse-engineered, disassembled, or otherwise reduced to human-perceivable form. This is not a sale of the software or any copy of the software; all right, title, and ownership of the software remain with Welch Allyn or its vendors.
For information about any Welch Allyn product, contact your local Welch Allyn representative:
www.welchallyn.com/about/company/locations.htm.
723809
DIR 80020550 Ver. A Revised 2016–01
This manual applies to
901077 Weight scale.
Manufactured for Welch Allyn, Inc. 4341 State Street Road Skaneateles Falls, NY 13153-0220 USA
Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No. 105, Dongli Road Torch Development District Zhongshan, 528437, Guangdong, China
www.welchallyn.com
Contents
Introductory information ........................................................................ 1
Use the scale ............................................................................................ 7
iii
Introduction .......................................................................................................... 1
Symbols ............................................................................................................... 1
About warnings and cautions ............................................................................... 3
Ensure accurate measurements .......................................................................... 4
Content list ........................................................................................................... 4
Controls and indicators ........................................................................................ 4
Screen elements .................................................................................................. 5
Startup ................................................................................................................. 7
Insert or replace the batteries .............................................................................. 7
Pair a connection hub with the scale ................................................................... 7
Select the measurement unit .............................................................................. 8
Obtain measurement ........................................................................................... 8
Stop a measurement ........................................................................................... 8
Maintain the scale ................................................................................................ 8
Troubleshooting .................................................................................................. 9
Appendices ............................................................................................ 11
Specifications ..................................................................................................... 11
General radio compliance ................................................................................... 12
Complied standards list ...................................................................................... 13
Emissions and immunity information ................................................................. 14
Warranty ............................................................................................................ 17
Approved accessories ........................................................................................ 18
iv Contents Welch Allyn Remote Monitoring Scale RPM-Scale100
Introductory information
Introduction
The Welch Allyn Remote Monitoring Scale is intended for adults and children (10-17 years old) to measure weight in a home environment.
Directions for use contains important safety and care information and provides step
This by step instructions for using the scale. Read the manual thoroughly before using the scale.
1
For information about any Welch Allyn product, contact your local Welch Allyn representative at www.welchallyn.com/about/company/locations.htm.
Indications for use
The Welch Allyn Remote Monitoring Scale is intended for adults and children (10–17 years old) to measure weight in home.
Contraindications
This device is contraindicated for any person who is connected to a wearable or implantable electronic device or instrument, such as a pacemaker or defibrillator.
Symbols
Documentation symbols
Warning: The warning statements in this manual identify conditions or practices that could lead to illness, injury, or death. Warning symbols will appear with a grey background in a black and white document.
Caution: The caution statements in this manual identify conditions or practices that could result in damage to the equipment or other property, or loss of data.
Mandatory - Consult Directions for Use
2 Introductory information Welch Allyn Remote Monitoring Scale RPM-Scale100
Power symbols
Direct current (DC)
Shipping, storing, and environment symbols
Humidity limitation Separate collection of
Electrical and Electronic Equipment. Do not dispose as unsorted municipal waste.
Temperature limit Atmospheric pressure
limitation
Recycle Stacking limit by number
Connectivity symbols
Bluetooth® wireless technology enabled
Miscellaneous symbols
Serial number Manufacturer
Product identifier, product family catalogue number Non-ionizing electromagnetic
Reorder number, Model number Global Trade Item Number
IP22
The ingress protection: the device could protected against solid foreign objects of 12.5mm and greater, and against vertically falling water drops when ENCLOSURE tilted up to 15°
radiation
Type BF applied parts
Directions for use Introductory information
About warnings and cautions
Caution statements can appear on the Welch Allyn weight scale device, the packaging, the shipping container, or in this
The Welch Allyn weight scale is safe for patients and clinicians when used in accordance with the instructions and caution statements presented in this Directions for use.
Before using the device, you must familiarize yourself with all cautions, with the steps to power up the device, and with the sections of this Directions for use that pertain to your use of the device. In addition to reviewing the general cautions presented in the next section, you must also review the more specific cautions that appear throughout the manual in conjunction with setup/startup, operation, and maintenance tasks.
Failure to understand and observe any warning statement in this manual could lead to patient injury or illness.
Failure to understand and observe any caution statement in this manual could lead to damage to the equipment or other property, or loss of patient data.
General warnings and cautions
Directions for use.
3
Warning Patient injury risk. Do not use the scale on a slippery floor, such as tile.
Warning Patient injury risk. Do not jump onto the platform immediately after bathing or with wet hands.
Warning Patient injury risk. Keep the device clean. Patient contact with contaminated equipment can spread infection. Clean the device after each patient use.
Warning Patient injury risk. Dispose of accessories, detachable parts, and the ME equipment according to the local guidelines.
Warning Patient injury risk. The device is not suitable for use in the presence of flammable anesthetic mixtures with air or with oxygen or nitrous oxide.
Warning Patient injury risk. No modification of this equipment is allowed. Modifying the equipment could cause patient injury.
Warning Patient injury risk. Do not touch output of the batteries and the patient simultaneously.
Warning Patient injury risk. Before use, make sure the device functions safely and is in proper working condition.
Warning Patient injury risk. When the scale is in use, there should not be any electrical appliances nearby, such as high voltage cables, X-ray machines, or ultrasound equipment.
Warning Possible injury risk. The device contains small parts. Keep the equipment away from children and pets.
CAUTION Avoid storing the device where the device may be exposed to extreme temperatures, humidity, moisture, direct sunlight, dust, or salt air.
Loading...
+ 16 hidden pages