Watson-Marlow 401U User Manual

401U
401u-gb-03.pdf
Declarations
Declaration of conformity
Declaration of Incorporation
Responsible person: Christopher Gadsden, Managing Director, Watson-Marlow Limited, Falmouth, Cornwall TR11 4RU, England. Telephone +44 (0) 1326 370370. Fax +44 (0) 1326 376009.
When this pump unit is used as a stand alone pump it complies with: Machinery Directive 2006/42/EC, EMC Directive 2004/108/EC.
When this pump unit is to be installed into a machine or is to be assembled with other machines for installations, it must not be put into service until the relevant machinery has been declared in conformity with the Machinery Directive 2006/42/EC.
Two year warranty
Watson-Marlow Limited warrants, subject to the conditions below, through either Watson-Marlow Limited, its subsidiaries, or its authorised distributors, to repair or replace free of charge, including labour, any part of this product which fails within two years of delivery of the product to the end user. Such failure must have occurred because of defect in material or workmanship and not as a result of operation of the product other than in accordance with the instructions given in this manual.
Conditions of and specific exceptions to the above warranty are
Consumable items such as tubing, rollers and motor brushes are excluded.
Products must be returned by pre-arrangement carriage paid to Watson-Marlow Limited, its subsidiaries, or its authorised distributor.
All repairs or modifications must have been made by Watson-Marlow Limited, its subsidiaries, or its authorised distributors or with the express permission of Watson-Marlow Limited, its subsidiaries, or its authorised distributors.
Products which have been abused, misused, or subjected to malicious or accidental damage or electrical surge are excluded.
Warranties purporting to be on behalf of Watson-Marlow Limited made by any person, including representatives of Watson-Marlow Limited, its subsidiaries, or its distributors, which do not accord with the terms of this warranty shall not be binding upon Watson-Marlow Limited unless expressly approved in writing by a director or manager of Watson-Marlow Limited.
Information for returning pumps
Equipment which has been contaminated with, or exposed to, body fluids, toxic chemicals or any other substance hazardous to health must be decontaminated before it is returned to Watson-Marlow Limited or its distributor.
A certificate included at the rear of these operating instructions, or signed statement, must be attached to the outside of the shipping carton.
This certificate is required even if the pump is unused. If the pump has been used, the fluids that have been in contact with the pump and the cleaning procedure must be specified along with a statement that the equipment has been decontaminated.
2
Safety
In the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained personnel after they have read and understood this manual, and considered any hazard involved.
Any person who is involved in the installation or maintenance of this equipment should be fully competent to carry out the work. In the UK this person should also be familiar with the Health and Safety at Work Act 1974.
There are no user serviceable parts inside this pump. The unit should be turned to Watson-Marlow for service.
Installation
The 401U/D is suitable for single phase mains electricity supplies only via the 230VAC-15VAC mains
transformer or a 100-240VAC-18VDC mains adaptor. The CW/STOP/CCW front panel potentiometer should be set in the STOP position before the power supply is connected by inserting the mains transformer jack plug into the back panel socket.
Use only the approved 15V Mascot type 810 AC/AC adaptor or the 18VDC CMP SA07H18 AC/DC
adaptor supplied with the pump.
To ensure correct lubrication of the gearbox, the pump should be run only while its feet are standing on
a horizontal surface. The pump should be positioned to allow a free flow of air around it.
Recommended operating procedures
DO keep delivery and suction lines as short as possible using a minimum number of swept bends.
DO use suction and delivery pipelines with a bore equal to or larger than the bore of the tube fitted in the
pumphead. When pumping viscous fluids, the losses caused by increased friction can be overcome by using pipe runs with a cross sectional area several times greater than the pumping element.
DO run at a slow speed when pumping viscous fluids.
DO fit an extra length of pump tube in the system to enable tube transfer. This will extend tube life and
minimise the downtime of the pumping circuit.
DO keep the track and rollers clean.
The self-priming nature of peristaltic pumps means valves are not required. Any valves fitted must cause no restriction to flow in the pumping circuit.
When using Marprene tubing After the first 30 minutes of running, re-tension the tube in the pumphead by releasing the track latch and pulling the tubing on the delivery side a little. This is to counteract the normal stretching that occurs with Marprene which can go unnoticed and result in poor tube life.
Tube selection The chemical compatibility list published in the Watson-Marlow catalogue is only a guide. If in doubt about the compatibility of a tube material and the duty fluid, request a tube sample card for immersion trials.
Troubleshooting
If the pump fails to operate, make the following checks to determine whether or not servicing is required.
Check the mains supply is available at the pump (green LED).
Check the fuse in the mains socket (where fitted).
Check that the pump is not stalled by incorrect fitting of tubing.
3
Manual operation
cwccw cwccw cwccw
0
1
2
3
4
5
6
7
8
9
10
IP21
Insert the mains transformer jack plug into the round socket on the pump back panel.
EU US UK AU18VDC CMP SA07H18
Pumps delivered with multi-plug mains adaptor: see pictures above for how to change plugs.
Switch power on at the mains socket. Power at the pump will be signalled by the illumination of a green
LED on the pump front panel.
The manual speed control potentiometer has three positions.
Centre position (III) means that the pump rotor will be stopped
cw position (III) means the rotor will rotate clockwise at its set speed
ccw position (III) means the rotor will rotate counter-clockwise at its set speed.
0
1
2
3
10
cwccw
9
4
8
5
7
6
0
1
2
3
10
cwccw cwccw
9
4
8
5
7
6
• The speed setting dial is calibrated in proportion of maximum speed from 0-10 which represents a 10:1
speed reduction ratio from the maximum speed of the pump. Turn the control knob clockwise to increase the speed and counter-clockwise to decrease the speed.
When changing the direction of flow, turn the ccw<off>cw switch to its central off position until the
pumphead rotor stops; then turn it to the required direction of rotation which will re-start the pump.
If returning from auto control to manual control, disconnect the process signal from the pump.
In the event of a power failure, the pump will automatically re-start when the power is returned. This will occur under manual or remote control.
4
Remote control
The 401U pump can be controlled remotely via 0-10V or 4-20 mA analogue signals. 400AC1, 400AC2, 400AC3 and 400AC4 remote control cables with a 15-pin D-sub connector are available from your local Watson-Marlow dealer. Wiring diagrams for each control cable are shown at the bottom of this section.
When using the 400AC1 (0-10V) or 400AC2 (4-20mA) remote control cables for analogue speed control and switching cw/stop/ccw:
Set the front panel control potentiometer to the centre position (stop).
The manual speed control potentiometer sets the range of the remote speed signal, and it can be
adjusted during remote control use. If the manual speed is set to 5 the remote control works for speeds 0-50%. Set the manual control potentiometer to 10 for full analogue speed range control.
Start or stop the pump in either cw or ccw direction remotely as shown in the relevant wiring
diagrams. If the remote switch is set to stop, cw or ccw direction switching can be achieved using the front control potentiometer.
When using the 400AC3 cw/stop/ccw remote cable
Set the pump speed using the manual speed control potentiometer.
Start or stop the pump in either cw or ccw direction remotely as shown in the relevant wiring diagram.
If the remote switch is set to stop, cw or ccw direction switching can be achieved using the front control potentiometer.
When using the 400AC4 start/stop 3m remote cable with footswitch fitted:
Set the pump speed and direction of rotation via the manual speed control potentiometer.
Start or stop the pump remotely as shown in the relevant wiring diagram.
1
2
11
+
400AC1
4
0-10V
5
8
9
11
4
5
1
-
4-20mA
400AC2 400AC3
6
7
8
1
45
2
8
Care and maintenance
The only scheduled maintenance of the pump unit is to inspect the motor brushes and to replace them when necessary, understanding that motor brushes are not covered by the two-year warranty. It is recommended that all maintenance to this pump is carried out by a Watson-Marlow servicing agent.
The life of the brushes depends on the duty of the pump but is expected to be at least 2500 hours.
If the pump requires cleaning use a mild solution of detergent in water after removing the pumphead. Do not use strong solvents.
5
Pump spares
1
6
Number Part number Description
2
3 4 5
1 100 724-MINI, 400-S Control board 2 010041 Tube clamps D1
000107 Tube clamps DM2 000078 Tube clamps DM3
3 MRX M4x6 A4 Rotor screws 4 010014 Rotor D1
010015 Rotor DM2 010016 Rotor DM3
5 010038 Occlusion arm 6 970113 16843 75:1 Motor gearbox kit
MFX M3x8 A4 Gearbox screws D6 B 35x10 NN A542 SPTAND A4 Case screws
Specification
Maximum rotor speeds for 400D 15rpm, 40rpm, 200rpm Maximum rotor speeds for 400DM 15rpm, 40rpm, 100rpm Voltage/frequency 15VAC / 18VDC Control range 10:1 Operating temperature range 5 to 40C Storage temperature range -40C to 70C Weight 1.0kg Noise <70 dBA @ 1m Standards EN60529 (IP21)
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC
6
400D, 400DM2 and 400DM3 pumpheads
Tube life and performance against pressure
The pressure and the suction height can be increased by compressing the spring in the sprung track pin. A smaller gap between the rollers and track will give better performance against pressure but will reduce tube life.
Other application factors that will influence tube life in peristaltic pumps are pump speed and number of rollers (roller impacts/minute), temperature, chemical compatibility of the duty fluid and viscosity of the duty fluid. Several tubing materials are available offering different levels of life expectancy. The tubing’s dimensional tolerances from the manufacturing process will also influence the life of a tube.
This means that it is impossible to predict tube life in any particular application.
In perfect conditions of no suction or discharge pressure, in a clean environment at normal room temperature, and pumping water, nominal tube life may be:
Marprene and Bioprene less than 6,000 hours Silicone less than 250 hours Others less than 100 hours
The factors highlighted above will tend to reduce tube life. Users are advised to determine likely tube life in their application and make routine tube changes at suitable intervals.
Key Safety Information
Before changing the tubing in the pumphead
Ensure that there is no pressure, liquid or gas in the pipeline.
Disconnect the pump from the mains to prevent the pump from starting unexpectedly.
Always replace any protective guard after tube changeover.
If a tube failure has occurred, ensure that any product in the pumphead has been allowed to drain to
a safe area.
Ensure that protective clothing and eye protection are worn if aggressive products are being pumped.
400D pumphead setup (used on 401U/D pump)
The 400D pumphead is designed to accept 1.6mm wall standard laboratory tubing from 0.5mm bore up to
3.2mm bore. Care should be taken to establish the normal tube life experienced within a set of operating
parameters. Subsequent tubing replacement should be scheduled within the normal expected life of a tube. This will avoid unnecessary tube failure and unplanned pump maintenance.
7
Tube loading
Release the track by disengaging the sprung track pin.
Before tube loading, make sure that enough suction and delivery tubing is available to connect into
the remaining pipeline or to reach the suction reservoir and delivery point.
Locate the tubing into the suction side tube clamp. Feed the tubing in around the rotor, maintaining
reasonable tube tension so that the tube sits around the rotor, and locate into the delivery side tube clamp. Make sure that there are no twists or kinks in the tubing after loading as this will reduce tube life.
Ensure the tube is lined up centrally in the track and correctly secured at each clamp.
Reposition the track over the rotor and fix by slotting the track pin back into the track slot.
Tube re-tensioning
· When using Marprene tubing After the first 30 minutes of running, re-tension the tube in the pumphead
by releasing the sprung track pin and pulling the tubing on the delivery side a little. This is to counteract the normal stretching that occurs with Marprene which can go unnoticed and result in poor tube life.
Tube removal
· Release the track by disengaging the sprung track pin and withdraw the tubing from the sprung clamps.
8
400DM2 and 400DM3 pumpheads setup (used on 401U/D pump)
The 400DM2 and 400DM3 pumpheads are designed to accept three-bridge manifold tubing only. Each piece of three-bridge manifold tubing has two pumping sections. When flow performance falls with one section this is a sign of tube wear and should be used as an indicator to switch over to using the second section. When the switch to the second section is made, check the first section of tubing is not adversely affected by normal line pressure. If this is the case then the complete section of tubing will need to be replaced.
Tube loading
Release the track by disengaging the sprung track pin.
Locate the first tube bridge into the appropriate tube bridge holder slot. Feed the tubing in around the
rotor. Locate the centre tube bridge into the bridge holder slot immediately opposite the first tube bridge. Repeat for the remaining one (400DM2) or two (400DM3) channels. Make sure that there are no twists or kinks in the tubing after loading as this will adversely affect tube life.
Tube removal
Release the track by disengaging the sprung track pin.
Remove both tubing bridges from their location slots and remove the tubing from the pumphead.
Pumphead spares
Description 400D1 400DM2 400DM3
Track 940418 940418 940920 Track latch (occlusion) arm 010038 010038 010038 Rotor 010014 010015 010016 Tube clamps 010041 000107 000078 Rotor screw MRX M4X6 A4 MRX M4X6 A4 MRX M4X6 A4
9
Flow rates
The tables below list the approximate water-flow rate per revolution for the 400D pumpheads. The flow rate will depend on the duty fluid (viscosity, density etc.), pressure, temperature, speed, tubing and the installation. For accurate flow rates and repeatability calibrate the pump for your application.
400D1
Tubing I.D. (mm) 0.5 0.8 1.6 3.2 Flowrate (ml/rev) 0.012 0.056 0.087 0.425
1.2 - 12rpm 0.02-0.2 0.04-0.4 0.14-1.4 0.49-4.9 4 - 40rpm 0.07-0.7 0.14-1.4 0.48-4.8 1.6-16 20 - 200rpm 0.34-3.4 0.68-6.8 0.24-24 8.2-82
400DM2 & 400DM3
Colour Orange/Black Orange/Red Orange/Blue Orange/Green Orange/Yellow Bore 0.13mm 0.005" 0.19mm 0.007" 0.25mm 0.010" 0.38mm 0.015" 0.50mm 0.020"
1-12rpm 0.002- 0.02 0.003-0.03 0.004-0.04 0.01-0.1 0.02-0.2 4-40 rpm 0.008- 0.08 0.011-0.11 0.015-1.5 0.04-0.4 0.05-0.5 10-100 rpm 0.019- 0.19 0.028-0.28 0.037-0.37 0.10-1.0 0.13-1.3
Colour Orange/White Black/Black Orange/Orange White/White Red/Red Bore 0.63mm 0.025" 0.76mm 0.030" 0.88mm 0.035" 1.02mm 0.040" 1.14mm 0.045"
1-12rpm 0.03-0.3 0.04-0.4 0.05-0.5 0.07-0.7 0.09-0.9 4-40 rpm 0.10-1.0 0.15-1.5 0.18-1.8 0.25-2.5 0.29-2.9 10-100 rpm 0.25-2.5 0.37-3.7 0.46-4.6 0.62-6.2 0.74-7.4
Colour Grey/Grey Yellow/Yellow Yellow/Blue Blue/Blue Green/Green Bore 1.29mm 0.050" 1.42mm 0.055" 1.52mm 0.060" 1.65mm 0.065" 1.85mm 0.07
1-12rpm 0.10-1.0 0.14-1.4 0.14-1.4 0.17-1.7 0.21-2.1 4-40 rpm 0.34-3.4 0.46-4.6 0.47-4.7 0.56-5.6 0.70-7.0 10-100 rpm 0.85-8.5 1.1-11 1.2-12 1.4-14 1.7-17
Colour Purple/Purple Purple/Black Purple/Orange Purple/White Bore 2.05mm 0.080" 2.38mm 0.090" 2.54mm 0.100" 2.79mm 0.110"
1-12rpm 0.25-2.5 0.29-2.9 0.39-3.9 0.44-4.4 4-40 rpm 0.84-8.4 0.98-9.8 1.3-13 1.5-15 10-100 rpm 2.1-21 2.5-25 3.2-32 3.6-36
10
Outline dimensions
401U/D1
401U/DM2
401U/DM3
Watson-Marlow, Bioprene and Marprene are trademarks of Watson-Marlow Limited. Tygon is a trademark of the Saint Gobain Performance Plastics Company. STA-PURE is a trademark of W.L.Gore & Associates.
Warning, These products are not designed for use in, and should not be used for patient connected applications. The information contained in this document is believed to be correct but Watson-Marlow Limited accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
11
Product Use and Decontamination Certificate
In compliance with the UK Health & Safety at Work Act and the Control of Substances Hazardous to Health Regulations you, the user are required to declare the substances which have been in contact with the product(s) you are returning to Watson-Marlow or any of its subsidiaries or distributors. Failure to do so will cause delays in servicing the product. Therefore, please complete this form to ensure that we have the information before receipt of the product(s) being returned. A FURTHER COPY MUST BE ATTACHED TO THE OUTSIDE OF THE PACKAGING CONTAINING THE PRODUCT(S).
You, the user, are responsible for cleaning and decontaminating the product(s) before returning them.
Please complete a separate Decontamination Certificate for each pump returned.
RGA No: ...................................................................
1. Company ........................................................................................................................................................................................
Address ........................................................................................................................................................................................
............................................................................................ Postcode ...........................................................
Telephone ............................................................................................ Fax number ...........................................................
2. Product ....................................................
2.1 Serial number ....................................................
2.2 Has the product been used?
YES NO If yes, please complete all the following Sections. If no, please complete Section 5 only
3. Details of substances pumped
3.1 Chemical names
(a) ..................................................................................
(b) ..................................................................................
(c) ..................................................................................
3.3 Action to be taken in the event of human contact
(a) ..................................................................................
(b) ..................................................................................
(c) ..................................................................................
(d) ..................................................................................
(d) ..................................................................................
3.4 Cleaning fluid to be used if residue of chemical is
3.2 Precautions to be taken in handling these substances
(a) ..................................................................................
(b) ..................................................................................
(c) ..................................................................................
(d) ..................................................................................
found during servicing
(a) ..................................................................................
(b) ..................................................................................
(c) ..................................................................................
(d) ..................................................................................
Note: Please describe current faults ...............................................................................................................................................
............................................................................................................................................................................................................
............................................................................................................................................................................................................
............................................................................................................................................................................................................
4. I hereby confirm that the only substances(s) that the
5. Signed ...................................................................
equipment specified has pumped or come into contact with are those named, that the information given is correct, and the carrier has been informed if the consignment is of a hazardous nature.
Name ...................................................................
Position ...................................................................
Date ...................................................................
Watson-Marlow Bredel Pumps Falmouth Cornwall TR11 4RU England Tel:+44 (0) 1326 370370 Fax: +44 (0) 1326 376009
12