Watson-Marlow 323Du User Manual

Watson-Marlow 323E, 323S, 323U and 323Du User Manual 1
WATSON-MARLOW BREDEL MANUALS
Watson-Marlow 323E, 323S, 323U and 323Du pumps
m-323e-s-u-du-gb-06
Contents
1 Declaration of conformity 2 2 Declaration of incorporation 2 3 Two-year warranty 3 4 When you unpack your pump 4 5 Information for returning pumps 5 6 Peristaltic pumps: an overview 6 7 Safety notes 7 8 Pump specifications 9
8.1 Pump features 9
8.2 Dimensions 14
9 Good pump installation practice 15
9.1 General recommendations 15
9.2 Do’s and do not’s 16
10 Connecting this product to a
power supply 17 11 Start-up check list 18 12 Switching the pump on 18 13 Auto-restart facility 19 14 Manual operation 20 15 Keypad lock 21 16 MemoDose 22 17 Automatic operation with
analogue signals, remote
control or RS232 link 23
17.1 Analogue signals and remote control 24
17.2 Automatic control wiring using the 720N module 26
18 Care and maintenance 28 19 Troubleshooting 28
19.1 Error messages 29
20 Drive maintenance 30 21 Drive part numbers 30 22 Drive spares 31 23 Pumpheads 32
23.1 Pumpheads: key safety information 32
23.2 313D and 314D pumpheads 32
23.3 313D and 314D pumphead order codes 34
23.4 313D and 314D flow rates 35
23.5 313D and 314D: maximum number of pumpheads 36
23.6 313D and 314D: tubing part numbers 37
23.7 314MC and 318MC microcassette pumpheads 38
23.8 314MC and 318MC microcassette pumphead spares 40
23.9 314MC and 318MC flow rates 41
23.10 314MC and 318MC tubing part numbers 42
23.11 501RL pumphead 43
23.12 501RL and 501RL2 installation 43
23.13 501RL and 501RL2 tube loading 43
23.14 501RL and 501RL2 rotor settings 44
23.15 501RL and 501RL2 pumphead spares 45
23.16 501RL and 501RL2 flow rates 46
23.17 501RL and 501RL2 tubing part numbers 46
24 Trademarks 47 25 Warning not to use pumps in
patient-connected applications 47 26 Publication history 47 27 Decontamination certificate 48
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 2
1 Declaration of conformity
This declaration was issued for Watson-Marlow 323E, 323S, 323U and 323Du pumps on November 1, 2007. When this pump unit is used as a stand-alone pump it complies with: Machinery Directive 2006/42/EC, EMC Directive 2004/108/EC.
This pump is ETL listed: ETL control number 3050250. Cert to CAN/CSAstd C22.2 No 61010-1. Conforms to UL std 61010A-1.
See 8 Pump specifications.
2 Declaration of incorporation
When this pump unit is to be installed into a machine or is to be assembled with other machines for installations, it must not be put into service until the relevant machin­ery has been declared in conformity with the Machinery Directive 2006/42/EC.
Responsible person: Christopher Gadsden, Managing Director, Watson-Marlow Lim­ited, Falmouth, Cornwall TR11 4RU, England. Telephone +44 (0) 1326 370370 Fax +44 (0) 1326 376009.
The information in this user guide is believed to be correct at the time of publication. However, Watson-Marlow Limited accepts no liability for errors or omissions. Watson­Marlow Bredel has a policy of continuous product improvement, and reserves the right to alter specifications without notice. This manual is intended for use only with the pump it was issued with. Earlier or later models may differ. The most up-to-date manuals appear on the Watson-Marlow website: http://www.watson-marlow.com
E, S, U, Du
E, S, U, Du
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 3
E, S, U, Du 3 Two-year warranty
Watson-Marlow Limited ("Watson-Marlow") warrants, subject to the conditions and exceptions below, through either Watson-Marlow, its subsidiaries, or its authorised distributors, to repair or replace free of charge, any part of the product which fails within two years of the day of manufacture of the product. Such failure must have oc­curred because of defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in this pump manual.
Watson-Marlow shall not be liable for any loss, damage, or expense directly or indi­rectly related to or arising out of the use of its products, including damage or injury caused to other products, machinery, buildings, or property, and Watson-Marlow shall not be liable for consequential damages, including, without limitation, lost profits, loss of time, inconvenience, loss of product being pumped, and loss of production. This warranty does not obligate Watson-Marlow to bear any costs of removal, instal­lation, transportation, or other charges which may arise in connection with a war­ranty claim.
Conditions of and specific exceptions to the above warranty are:
Conditions
Products must be returned by pre-arrangement, carriage-paid, to Watson-Mar-
low, or a Watson-Marlow approved service centre.
All repairs or modifications must have been made by Watson-Marlow Limited, or
a Watson-Marlow approved service centre or with the express permission of Watson-Marlow.
Warranties purporting to be on behalf of Watson-Marlow made by any person,
including representatives of Watson-Marlow, its subsidiaries, or its distributors, which do not accord with the terms of this warranty shall not be binding upon Watson-Marlow unless expressly approved in writing by a Director or Manager of Watson-Marlow.
Exceptions
The warranty shall not apply to repairs or service necessitated by normal wear
and tear or for lack of reasonable and proper maintenance.
All tubing and pumping elements as consumable items are excluded.Products which, in the judgment of Watson-Marlow, have been abused, misused,
or subjected to malicious or accidental damage or neglect are excluded.
Electrical surge as a cause of failure is excluded.Chemical attack is excludedAll pumphead rollers are excluded.Pumpheads from the 313/314 retain their one-year standard pumphead war-
ranty. The drive they are attached to is subject to the two-year warranty as set out here.
Ancillaries such as leak detectors are excluded.
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 4
E, S, U, Du 4 When you unpack your pump
Unpack all parts carefully, retaining the packaging until you are sure all components are present and in good order. Check against the components supplied list, below.
Packaging disposal
Dispose of packaging materials safely, and in accordance with regulations in your area. The outer carton is made of corrugated cardboard and can be recycled.
Inspection
Check that all components are present. Inspect components for damage in transit. If anything is missing or damaged, contact your distributor immediately.
Components supplied
Watson-Marlow 323E, 323S, 323U and 323Du pumps are supplied as:
Dedicated 323E, 323S, 323U or 323Du pump drive unit fitted with one or more
313 or 314 pumpheads (see 8 Pump specifications).
The designated mains power lead for your pump PC-readable CDROM containing these operating instructions Quick Start manual
Note: Some versions of this product will include components different from those listed above. Check against your purchase order.
Storage
This product has an extended shelf life. However, care should be taken after storage to ensure that all parts function correctly. Users should be aware that the pump con­tains a battery with an unused life of seven years. Long-term storage is not recom­mended for peristaltic pump tubing. Please observe the storage recommendations and use-by dates which apply to tubing you may wish to bring into service after stor­age.
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 5
E, S, U, Du 5 Information for returning pumps
Equipment which has been contaminated with, or exposed to, body fluids, toxic chem­icals or any other substance hazardous to health must be decontaminated before it is returned to Watson-Marlow or its distributor.
A certificate included at the rear of these operating instructions, or signed statement, must be attached to the outside of the shipping carton. This certificate is required even if the pump is unused. See 27 Decontamination certificate.
If the pump has been used, the fluids that have been in contact with the pump and the cleaning procedure must be specified along with a statement that the equipment has been decontaminated.
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 6
E, S, U, Du 6 Peristaltic pumps - an overview
Peristaltic pumps are the simplest pump, with no valves, seals or glands to clog or corrode. The fluid contacts only the bore of a tube, eliminating the risk of the pump contaminating the fluid, or the fluid contaminating the pump. Peristaltic pumps can run dry.
How they work
A compressible tube is squeezed between a roller and a track on an arc of a circle, creating a seal at the point of contact. As the roller advances along the tube, the seal also advances. After the roller has passed, the tube returns to its original shape, cre­ating a partial vacuum which is filled by fluid drawn from the inlet port.
Before the roller reaches the end of the track, a second roller compresses the tube at the start of the track, isolating a packet of fluid between the compression points. As the first roller leaves the track, the second continues to advance, expelling the packet of fluid through the pump’s discharge port. At the same time, a new partial vacuum is created behind the second roller into which more fluid is drawn from the inlet port.
Backflow and siphoning do not occur, and the pump effectively seals the tube when it is inactive. No valves are needed.
The principle may be demonstrated by squeezing a soft tube between thumb and fin­ger and sliding it along: fluid is expelled from one end of the tube while more is drawn in at the other.
Animal digestive tracts function in a similar way.
Suitable applications
Peristaltic pumping is ideal for most fluids, including viscous, shear-sensitive, corro­sive and abrasive fluids, and those containing suspended solids. They are especially useful for pumping operations where hygiene is important.
Peristaltic pumps operate on the positive displacement principle. They are particularly suitable for metering, dosing and dispensing applications. Pumps are easy to install, simple to operate and inexpensive to maintain.
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 7
E, S, U, Du 7 Safety notes
In the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained personnel after they have read and understood this man­ual, and considered any hazard involved. If the pump is used in a manner not spec­ified by Watson-Marlow Limited, the protection provided by the pump may be impaired.
This symbol, used on the pump and in this manual, means: Caution, refer to accompanying documents.
This symbol, used on the pump and in this manual, means: Do not allow fingers to contact moving parts.
This symbol, used on the pump and in this manual, means: Recycle this product under the terms of the EU Waste Electrical and Electronic Equipment (WEEE) Di­rective.
Fundamental work with regard to lifting, trans­portation, installation, starting-up, maintenance
and repair should be performed by qualified per­sonnel only. The unit must be isolated from mains power while work is being carried out.
Any person who is involved in the installation or periodic maintenance of this equip­ment should be suitably skilled or instructed and supervised using a safe system of work. In the UK this person should also be familiar with the Health and Safety at Work Act 1974.
There is a user-replaceable type T1.0AH 250V fuse
in the fuse drawer of the IEC mains connector at
the back of the pump, which also contains a spare
fuse. In some countries, the mains power plug contains an additional replaceable fuse. There are no user-ser­viceable fuses or parts inside this pump.
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 8
There are moving parts inside the pumphead. Before opening the track, en­sure that the following safety directions are followed.
Ensure that the pump is isolated from the mains power. Ensure that there is no pressure in the pipeline. If a tube failure has occurred, ensure that any fluid in the pumphead has been
allowed to drain to a suitable vessel, container or drain.
Ensure that protective clothing and eye protection are worn if hazardous fluids
are pumped.
Primary operator protection from rotating parts of the pump is provided by the
pumphead track. See 23 Pumpheads.
This product does not comply with the ATEX directive and must not be used in explosive atmospheres.
This pump must be used only for its intended purpose. The pump must be accessible at all times to facilitate operation and maintenance. Access points must not be ob­structed or blocked. The pump’s mains plug is the disconnecting device (for isolating the motor drive from the mains supply in an emergency). Do not position the pump so that it is difficult to disconnect the mains plug. Do not fit any devices to the drive unit other than those tested and approved by Watson-Marlow. Doing so could lead to injury to persons or damage to property for which no liability can be accepted.
If hazardous fluids are to be pumped, safety procedures specific to the particular fluid and application must be put in place to protect against injury to persons.
The exterior surfaces of the pump may get hot during operation. Do not take hold of the pump while it is running. Let it cool after use before handling it.
No attempt should be made to run the drive without a pumphead fitted.
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 9
E, S, U, Du 8 Pump specifications
Labels fixed to the rear of the pump contain manufacturer and contact details, product reference number, serial number and model details.
Features 323E 323S 323U 323Du
Manual control • Backlight • Beeper • Manual screen: rpm • 15-400 rpm 27:1 speed control • 3-400 rpm 133:1 speed control
1.5-220 rpm 147:1 speed control • 5 rpm scrolling increment • 1 rpm scrolling increment • Auto-restart • Keypad lock • MemoDose • Analogue input: 4-20mA, 0-10V • Remote stop/start control • Remote direction control • RS232 control • 313D and 314D pumpheads • 501RL and 501RL2 pumpheads • 314MC and 318MC pumpheads • ~100-120V/~220-240V operation • IP31 wipe-down case
8.1 Pump features
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 10
15-400 rpm 3-400 rpm
Four models of 323 drives are documented in this manual: 323E, 323S, 323U and 323Du, with varying functionality, as described earlier in this section. The 323E is fit­ted with a short-nosed gearbox, offers 15-400 rpm, and can be fitted with a 313 or 314 pumphead. The 323S, 323U and 323Du are available with a choice of gearboxes: a short-nosed gearbox, which offers 3-400 rpm and can be fitted with a 313 or 314 pumphead, or a 314MC or a 318MC pumphead; and a long-nosed gearbox, which of­fers 1.5-220 rpm and can be fitted with a 501RL or a 501RL2 pumphead. See 23 Pumpheads.
323S, 323U, 323Du
1.5-220 rpm
323E
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 11
IP
NEMA
1st Digit 2nd Digit
3
Protected against ingress of solid objects with a diameter of more than 2.5mm. Tools, wires etc with a thickness of more than
2.5mm are prevented from approach
1
Protection against dripping water falling vertically. No harmful effect must be produced
2
Indoor use to provide a degree of protection against limited amounts of falling water and dirt
5
Protected against harmful dust deposits. Ingress of dust is not totally prevented but the dust must not enter in sufficient quantity to interfere with satisfactory operation of the equipment. Complete protection against contact
5
Protection against water projected from a nozzle against the equipment (enclosure) from any direction. There must be no harmful effect (water jet)
12
Indoor use to provide a degree of protection against dust, falling dirt and dripping, non­corrosive liquids
13
Indoor use to provide a degree of protection against dust and spray­ing of water, oil and non-corrosive coolants
6
Protection against ingress of dust (dust­tight). Complete protection against contact
6
Protection against heavy seas or powerful water jets. Water must not enter the equipment (enclosure) in harmful quantities (splashing over)
4X
Indoor or outdoor use* to provide a degree of protection against splashing water, wind­blown dust and rain, hose-directed water; undamaged by the formation of ice on the enclosure. (Resist corrosion: 200-hour salt spray)
IP (Ingress Protection) and NEMA definitions
* Protect from prolonged UV exposure.
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 12
Supply voltage/frequency 100-120V/200-240V 50/60Hz 1ph
Maximum voltage fluctuation
±10% of nominal voltage. A well
regulated electrical mains supply is re-
quired along with cable connections con-
forming to the best practice of noise
immunity
Installation category (overvoltage category)
II
Power consumption 100VA
Full load current <0.43A at 230V; <0.86A at 115V
Eprom version Accessible through pump software
Enclosure rating
IP31 to BS EN 60529; Equivalent to
NEMA 2. Suitable for indoor use. Pro-
tected against dripping water and falling
dirt. May be wiped with a damp cloth but
should not be immersed
Operating temperature range 4C to 40C, 40F to 104F
Storage temperature range -40C to 70C, -40F to 158F
Maximum altitude 2,000m, 6,560ft
Humidity (non-condensing)
80% up to 31C, 88F, decreasing
linearly to 50% at 40C, 104F
Weight See 8.2 Dimensions
Noise <70dB(A) at 1m
Pump specifications
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 13
EC harmonised standards
Safety of machinery—electrical equipment of machines:
BS EN 60204-1
Safety requirements for electrical equipment for
measurement, control and laboratory use:
BS EN 61010-1 incorporating A2 Category 2, Pollution degree 2
Degrees of protection provided by enclosures (IP code):
BS EN 60529 amendments 1 and 2
Conducted emissions:
BS EN 55011 A1 and A2, Class A, called by BS EN 61000-6-4
Radiated emissions:
BS EN 55011 A1 and A2, Class A, called by BS EN 61000-6-4
Electrostatic discharge: BS EN 61000-4-2
Radiated RF immunity:
BS EN 61000-4-3 A1 and A2, called by BS EN 61000-6-2
Fast transient burst:
BS EN 61000-4-4 A1 and A2, Level 3 (2kV),
called by BS EN 61000-6-2
Surge immunity:
BS EN 61000-4-5 A1 and A2, called by BS EN 61000-6-2
Conducted RF immunity:
BS EN 61000-4-6, called by BS EN 61000-6-2
Voltage dips and interruptions:
BS EN 61000-4-11, called by BS EN 61000-6-2
Mains harmonics: BS EN 61000-3-2 A2
Pumps and pump units for liquids—common safety
requirements: BS EN 809
Other standards
UL 61010A-1
CAN/CSA-C22.2 No 61010-1
Conducted emissions FCC 47CFR, Part 15.107
Radiated emissions FCC 47CFR, Part 15
NEMA 2
Standards
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 14
8.2 Dimensions in millimetres
323E/D, 323S/D, 323U/D, 323Du/D
323S/MC, 323U/MC, 323Du/MC
323S/RL, 323U/RL, 323Du/RL
Drive only + 313 + 501RL
323 4.2kg, 9lb 4oz 4.5kg, 9lb 14oz 5.5kg, 12lb 2oz
Unit weights
Watson-Marlow 323E, 323S, 323U and 323Du User Manual 15
E, S, U, Du 9 Good pump installation practice
9.1 General recommendations
Position
A correctly engineered installation will promote long tube life. Site the pump on a flat, horizontal, rigid surface, free from excessive vibration. Allow a flow of air around the pump to ensure that heat can be dissipated. Ensure that the temperature around the pump does not exceed 40C.
Emergency disconnection
The pump’s mains plug is the disconnecting device (for isolating the motor drive from the mains supply in an emergency). Do not position the pump so that it is difficult to disconnect the mains plug. The STOP key on the keypad will always stop the pump. However, it is recommended that a suitable local emergency stop device is fitted into the mains supply to the pump.
Valves
Peristaltic pumps are self-priming and self-sealing against backflow. No valves are required in inlet or discharge lines. Valves in the process flow must be opened before the pump operates. Users are advised to fit a pressure relief device between the pump and any valve on the discharge side of the pump to protect against damage caused by accidental operation with the discharge valve closed.
The pump may be set up so that the direction of rotor rotation is clockwise or counter-clockwise, whichever is convenient.
Tubing materials: run-in advice
Sta-Pure and Marprene tubing are hard to compress when new. When using tubing made of these materials, the first 30 seconds should be at a speed of 10 rpm or greater. If the pump is run slower, the safety system built into pump drive’s soft­ware may cause it to stop and display an over-current error message.