Velleman DVM8861 User Manual [en, de, es, fr]

DVM8861
INFRARED THERMOMETER WITH DUAL LASER TARGETING INFRAROODTHERMOMETER MET DUBBELE LASERPOINTER THERMOMÈTRE INFRAROUGE À DOUBLE VISÉE LASER TERMÓMETRO INFRARROJO CON DOBLE PUNTERO LÁSER INFRAROTTHERMOMETER MIT DOPPELTEM LASERPOINTER
USER MANUAL 3 GEBRUIKERSHANDLEIDING 9 NOTICE D’EMPLOI 15 MANUAL DEL USUARIO 21 BEDIENUNGSANLEITUNG 27
DVM8861
User manual
1. Introduction
To all residents of the European Union Important environmental information about this product
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer.
2. Safety Instructions
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service.
Use extreme caution when the laser beam is turned on. When device is in use, do NOT look directly or indirectly (reflectance) into the laser beam. NEVER point the laser beam directly or via a reflecting surface towards other people’s or animals’ eyes. Permanent eye damage will result. Do not point the laser beam towards highly explosive gases. Keep out of reach of all children.
Keep this device away from rain and moisture
CLASS II
Damage caused by disregard of certain guidelines in this manual is not covered by the
warranty and the dealer will not accept responsibility for any ensuing defects or problems.
Keep the device away from splashing and dripping liquids.
Note that damage caused by user modifications to the device is not covered by the
warranty.
Keep the device away from children and unauthorised users.
00 (16/10/2008)
Visible laser radiation. Do not stare into the beam as eye damage may occur. This device contains a class 2 laser. Output power does not exceed 1 mW, wavelength 635~660nm.
3
.
DVM8861
3. General Guidelines
This device is battery-operated, using one 9V battery (incl.).
Protect this device from shocks and abuse. Avoid brute force when operating the
device.
Protected the device against extreme heat (see “Technical Specifications”), dust
and moisture.
Familiarise yourself with the functions of the device before actually using it.
All modifications of the device are forbidden for safety reasons.
Only use the device for its intended purpose. Using the device in an unauthorised way
will void the warranty.
4. Features
This non-contact Infrared Thermometer can be used to measure the temperature of surfaces that are difficult or dangerous to be measured with a traditional (contact) thermometer (e.g. moving object, food…)
Rapid detection function
Precise non-contact measurements
Dual laser sighting
Unique flat surface, modern housing design
Automatic Data Hold
°C/°F switch
Emissivity Digitally adjustable from 0.10 to 1.0
MAX temperature display
Backlit LCD display
Automatic range selection and Display Resolution 0.1ºC (0.1ºF)
Trigger lock
Set high and low alarms
Comes with soft carrying case
5. Use
1. IR sensor + laser beam
2. LCD Display
3. up button
4. down button
5. mode button
6. measurement trigger
7. battery cover
8.
handle grip
Configure the thermometer by pulling the measurement trigger (6) once. The display
lights up.
00 (16/10/2008)
4
DVM8861
A. data hold B. laser ‘on’ C. lock D. high/low alarm E. °C/°F indication F. battery indication G. emissivity value H. max. temperature value I. current temperature
Use the mode button (5) to scroll through the setup of the device. Use up (3) or down
(4) button to adjust the value and press the mode button (5) again to save the value and go to the next item. To cancel setup, pull the measurement trigger (6). Pushing the mode button (5) after setting the lower alarm limit will start the set-up cycle again.
Push # Function Range
1 Emissivity adjustment 0.10~1.00 2 Lock mode on / off 3 Enable alarm upper limit on / off 4 Set value upper limit -50~+550°C (-58~+1022°F) 5 Enable alarm lower limit on / off 6 Set value lower limit -50~+550°C (-58~+1022°F)
To switch between measurements in °C and °F, open the battery cover (7). Just
below the measurement trigger (6), a small switch is located. Move this switch gently to the left (for °F reading) or right (for °C reading) without touching any other internal parts of the thermometer. Close the battery cover (7). The setting is shown in the display (F).
Hold the meter by the handle grip (8) and point the IR sensor (1) towards the surface
of which the temperature needs to be measured.
Pull and hold the measurement trigger (6). The display (2) lights up and shows the
current temperature (I) and the maximum temperature (H).
During measurement, the word ‘SCAN’ is visible in the LED display. When the
measurement stops, the word ‘HOLD’ is shown. The last measured value will remain on the display until the measurement trigger (6) is pulled again, or when the thermometer powers-off automatically (after ± 7 seconds).
The maximum measured value of the current measurement is always shown in the
display (H).
00 (16/10/2008)
5
When a preset alarm limit is exceeded, an audible alarm signal will be produced, and
the according alarm icon in the display (D) will flash.
When the lock mode is enabled a small icon is shown in the display (C). The
thermometer will continuously measure the temperature until the measurement trigger (6) is pulled a second time.
During lock measurement, the emissivity can be changed with the up (3) and down
(4) button.
Push the down button (4) once to switch on the backlight. Push again to switch it off.
Push the up button (3) once to switch on the laser beam. Push again to switch it off.
The laser beam is only an aiming aid, be careful when using it. Refer to the safety instructions.
Notes:
The unit will not measure correctly through transparent surfaces (e.g. glass), as it will
measure the surface temperature of the transparent surface.
Steam, dust, smoke etc. will have a negative impact on the measurements accuracy.
Measurements on shiny and/or polished surfaces will be inaccurate.
DVM8861
6. Background information
Working principle
The Infra Red sensor of the unit detects energy that is emitted, reflected and transmitted by a surface. This energy is focussed onto a detector that converts this information into a temperature reading. The laser beam is only used for aiming purposes.
Ambient temperature
The thermometer automatically compensates ambient temperature conditions. Allow the thermometer to stabilise to ambient temperature for at least 30 minutes for accurate measurements. Surface temperature When going from low temperature to high temperature measurements or vice versa, the IR sensor of the thermometer needs a few minutes to adjust.
Distance and spot size
As the distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. The focal point for each unit is 914mm (36”).
D:S=12:1
150mm12.5mm @
25mm @
300mm
S
6in.
0.5in @
Emissivity
Emissivity describes the energy-emitting characteristics of materials. Most organic or oxidized surfaces have an emissivity of ±0.95 (default setting). Measuring shiny or
00 (16/10/2008)
6
1in @
D
12in.
polished surfaces will be inaccurate. Use some masking tape or paint to compensate, allow sufficient time for the tape or paint to reach the surface temperature.
Substance Emissivity Substance Emissivity
DVM8861
Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Leather 0.95 to 1.00 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matt) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium oxides 0.81 Plaster 0.80 to 0.90 Copper oxides 0.78 Mortar 0.89 to 0.91 Iron oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90
Field of view
The target must be larger than the spot size to ensure correct measurement. This means that for smaller targets, the thermometer must be held closer to the target. For best accuracy, make sure the target is at least twice as large as the spot size.
7. Troubleshooting
LCD display doesn’t light up when the measurements trigger is pulled.
The measured temperature changes very quickly and the shown value seems unlikely.
Display shows
Repairs or service should only be carried out by qualified and trained technicians.
Possibly a battery problem. Check and replace the battery.
Check the emissivity value. When set too low, inaccurate readings will result.
Over range indication, measured temperature is too high or too low. See specifications for temperature range.
8. Cleaning and storage
The IR sensor (1) is the most delicate part of the thermometer and should be kept clean at all times.
To do this, only use a soft cloth or cotton bud. Do not use excessive pressure on the sensor.
Wipe the other parts of the thermometer regularly with a dry cloth. Do not use abrasive solutions or solvents.
Do not submerge the thermometer in water or any other liquid.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
The device must be stored in a place with temperature conditions between 10°C and +60°C (+14°F and +140°F) and relative humidity lower than 80%.
00 (16/10/2008)
7
DVM8861
9. Battery
To replace the battery, wait until the device powers off
automatically (after ± 7 seconds). When the lock mode is on, switch it off first by pulling the measurement trigger (6) once.
Open the battery cover (7). The battery cover has a hinge at
the bottom of the device. Hold the battery cover at the top (next to the measurement trigger (6)) and gently pull away from the device.
Remove/insert the new 9V battery. Make sure the polarity is as
indicated in the casing.
Push the cover back towards the device until it snaps into
WARNING: A malfunction may occur if the power is on when the battery is replaced. Dispose of batteries in accordance with local regulations. Keep the battery away from children.
place.
10. Technical specifications
Temperature Overall range -50°C ~ +550°C (-58°F ~ +1.022°F) Temperature accuracy
T
=23~25°C
amb
(T
=73~77°F)
amb
Repeatability -50~+20°C (-58~+68°F)
Display resolution 0,1°C (0,1°F) <1.000
distance-to-spot ratio D:S = 12:1 Response time 150ms
Spectral response 8~14µm Emissivity Adjustable from 0.10 to 1.00, steps 0.01 Over range indication Display shows Operating temperature 0°C ~ +50 °C (+32°F ~ +122°F) Storage temperature -10°C ~ +60°C (+14°F ~ +140°F) Relative humidity 10%~90% operating, < 80% storage Diode laser Output <1mW, wavelength 630~670nm, Class II laser product Battery type 1x 9V battery dimensions 146mm x 104mm x 43mm weight 163 gr. (5.75 oz) (battery incl.)
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice.
00 (16/10/2008)
-50~+20°C (-58~+68°F) +20~+300°C (+68~+572°F) +300~+550°C (+572~+1.022°F)
+20~+550°C (+68~+1.022°F)
1°F > 1.000
8
±2,5°C (±4,5°F) ±1,0% ±1,0°C (±1,8°F) ±1,5%
±1,3°C (±2,3°F) ±0,5% or ±0,5°C (±0,9°F)
DVM8861
Gebruikershandleiding
1. Inleiding
Aan alle ingezetenen van de Europese Unie Belangrijke milieu-informatie betreffende dit product
Hebt u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.
Dank u voor uw aankoop! Lees deze handleiding grondig voor u het toestel in gebruik neemt. Werd het toestel beschadigd tijdens het transport, installeer het dan niet en raadpleeg uw dealer.
2. Veiligheidsinstructies
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt weggeworpen, dit toestel schade kan toebrengen aan het milieu. Gooi dit toestel (en eventuele batterijen) niet bij het gewone huishoudelijke afval; het moet bij een gespecialiseerd bedrijf terechtkomen voor recyclage. U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt brengen. Respecteer de plaatselijke milieuwetgeving.
Neem de grootst mogelijke voorzichtigheid in acht bij het gebruik van dit toestel. Kijk niet rechtstreeks in de laserstraal tijdens het gebruik van dit toestel om permanente oogletsels te voorkomen. Richt dit toestel NOOIT in de richting van de ogen of ontplofbare gassen. Houd buiten het bereik van kinderen.
Bescherm dit toestel tegen regen en vochtigheid
CLASS II
De garantie geldt niet voor schade door het negeren van bepaalde richtlijnen in
deze handleiding en uw dealer zal de verantwoordelijkheid afwijzen voor defecten of problemen die hier rechtstreeks verband mee houden.
Houd dit toestel uit de buurt van opspattende en druppelende vloeistoffen.
Schade door wijzigingen die de gebruiker heeft aangebracht aan het toestel vallen
niet onder de garantie.
Houd dit toestel uit de buurt van kinderen en onbevoegden.
00 (16/10/2008)
Zichtbare laserstraal. Kijk niet in de laserstraal om oogletsels te voorkomen. Dit toestel is een laserproduct klasse 2. Uitgangsvermogen < 1 mW, golflengte 635 ~ 660 nm.
9
.
DVM8861
3. Algemene richtlijnen
Dit toestel wordt gevoed door 1 x 9 V-batterij (meegeleverd).
Bescherm dit toestel tegen schokken. Vermijd brute kracht tijdens de bediening
van dit toestel.
Bescherm dit toestel tegen extreme temperaturen (zie ‘Technische specificaties’),
stof en vochtigheid.
Leer eerst de functies van het toestel kennen voor u het gaat gebruiken.
Om veiligheidsredenen mag de gebruiker geen wijzigingen aanbrengen aan het toestel.
Gebruik het toestel enkel waarvoor het gemaakt is. Andere toepassingen kunnen
leiden tot kortsluitingen, brandwonden, elektrische schokken, enz. Bij onoordeelkundig gebruik vervalt de garantie.
4. Eigenschappen
Deze infraroodthermometer is uiterst geschikt voor contactloze metingen van de oppervlaktetemperatuur die moeilijk te meten zijn met een gebruikelijke thermometer (bv. een bewegend voorwerp, voedsel…)
Snelle en precieze meting zonder contact
Dubbele laserpointer
Slank en modern design
Automatische bevriezing van de weergave
°C/°F keuzeschakelaar
Digitale instelling van de emissiviteit van 0,10 tot 1,0
Weergave van de maximumtemperatuur
Lcd-scherm met achtergrondverlichting
automatische instelling van het bereik en de schermresolutie – 0,1°C/0,1°F
vergrendeling van de meetknop
high- en lowalarm
geleverd met zachte draagtas
5. Gebruik
1. IR-sensor + laserstraal
2. lcd-scherm
3. ‘omhoog’-knop
4. ‘omlaag’-knop
5. ‘MODE’-knop
6. meetknop
7. batterijvak
8.
handvat
Configureer de thermometer door de meetknop (6) eenmaal in te drukken. De display
licht op.
00 (16/10/2008)
10
Loading...
+ 22 hidden pages