Accessory for
SUNNY BOY 2000HF-US SUNNY BOY 2500HF-US SUNNY BOY 3000HF-US
RS485-Quick Module
Installation Guide
RS485-QM-IA-eng-IUS111610 | IMUS-485QMODULE | Version 1.0 |
CA |
US |
SMA America, LLC |
Legal Restrictions |
Copyright © 2011 SMA America, LLC. All rights reserved.
Nopartofthisdocumentmaybereproduced,storedinaretrievalsystem,ortransmitted,inanyform or by any means, electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA America, LLC.
Neither SMA America, LLC nor SMA Solar Technology Canada Inc. makes no representations, expressorimplied,withrespecttothisdocumentationoranyoftheequipmentand/orsoftwareitmay describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for anyparticularpurpose.Allsuchwarrantiesareexpresslydisclaimed.NeitherSMAAmerica, LLCnor its distributors or dealers nor SMA Solar Technology Canada Inc. nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances.
(The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.)
Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that
SMA America, LLC and SMA Solar Technology Canada Inc. reserve the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material.
All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA America, LLC and SMA Solar Technology Canada Inc. is under license.
SMA America, LLC
3801 N. Havana Street
Denver, CO 80239 U.S.A.
SMA Solar Technology Canada Inc.
2425 Matheson Blvd
8th Floor
Mississauga, ON L4W 5K5
Canada
Installation Guide |
RS485-QM-IA-eng-IUS111610 |
3 |
Important Safety Instructions |
SMA America, LLC |
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions for RS485-Quick Module
accessory, that must be followed during installation and maintenance of the inverter.
The RS485-QuickModule isdesignedandtestedaccordingtointernational safety requirements,but as with all electrical and electronic equipment, certain precautions must be observed when installing and/or operating the RS485-Quick Module. To reduce the risk of personal injury and to ensure the safe installation and operation of the RS485-Quick Module, you must carefully read and follow all instructions, cautions and warnings in this Installation Guide.
Warnings in this document
Awarningdescribesahazardtoequipmentorpersonnel.Itcallsattentiontoaprocedureorpractice, which,ifnotcorrectlyperformedoradheredto,couldresultindamagetoordestructionofpartorall of the SMA equipment and/or other equipment connected to the SMA equipment or personal injury.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNINGindicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to personal injury.
4 |
RS485-QM-IA-eng-IUS111610 |
Installation Guide |
SMA America, LLC |
Important Safety Instructions |
Other Symbols in this document
In addition to the safety and hazard symbols described on the previous pages, the following symbol is also used in this installation guide:
Information
This symbol accompanies notes that call attention to supplementary information that you should know and use to ensure optimal operation of the system.
General Warnings
General Warnings
All electrical installations must be done in accordance with the local and
National Electrical Code® ANSI/NFPA 70 or the Canadian Electrical Code®
CSA C22.1. This document does not and is not intended to replace any local, state, provincial, federal or national laws, regulation or codes applicable to the installation and use of the inverter, including without limitation applicable electrical safety codes. All installations must conform with the laws, regulations, codes and standards applicable in the jurisdiction of installation. SMA assumes no responsibility for the compliance or noncompliance with such laws or codes in connection with the installation of the inverter.
For all repair and maintenance always return the unit to an authorized SMA Service Center.
Before installing or using the RS485-Quick Module, read all of the instructions, cautions, and warnings on the RS485-Quick Module in this installation guide.
Installation Guide |
RS485-QM-IA-eng-IUS111610 |
5 |
General Warnings |
SMA America, LLC |
6 |
RS485-QM-IA-eng-IUS111610 |
Installation Guide |
SMA America, LLC |
Table of Contents |
Table of Contents
1 Information on this Manual. . . . . . . . . . . . . . . . . . . . . . . . . 9
1.1 Validity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.2 Target Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.3 Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.4 Nomenclature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1 Appropriate Usage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1.1 RS485 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.1.2 Multi-function relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2 Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 RS485-Quick Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1 Scope of Delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.2 Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 3.3 Interior View of the RS485 Quick Module. . . . . . . . . . . . . . . . 12
4 Preparations for the RS485 Quick Module . . . . . . . . . . . 13
4.1 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4.2 Checking the Country Setting via the Rotary Switches . . . . . . . 13 4.3 Configuring the RS485 Quick Module. . . . . . . . . . . . . . . . . . . 14
4.3.1 Setting the language and installation country via the rotary switch . . . . . . . 14 4.3.2 Communication via Bluetooth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.4 Terminating the RS485 Bus. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installation Guide |
RS485-QM-IA-eng-IUS111610 |
7 |
Table of Contents |
SMA America, LLC |
5 Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.1 Open SMA DC-Disconnect. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.2 Connecting the RS485 Quick Module to the RS485 bus. . . . . 20
5.2.1 Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.3 Preparing the cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.4Installing the Cable Pipe and Introducing the Cable into the
Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.5Replacing Standard Quick Modules with
RS485 Quick Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5.6 Connecting the RS485 cable to the RS485 Quick Module. . . 23 5.7 Multi-function relay connection. . . . . . . . . . . . . . . . . . . . . . . . . 26
5.7.1 Connection Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5.8Closing the SMA DC-Disconnect and
Commissioning the Inverter. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6 Decommissioning and disposal . . . . . . . . . . . . . . . . . . . . 29
6.1 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 8 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8 |
RS485-QM-IA-eng-IUS111610 |
Installation Guide |
SMA America, LLC |
Information on this Manual |
This guide applies to the RS485-Quick Module (485QMUS-10-NR) for the following SMA inverters:
•Sunny Boy 2000HFUS (SB 2000HFUS-30)
•Sunny Boy 2500HFUS (SB 2500HFUS-30)
•Sunny Boy 3000HFUS (SB 3000HFUS-30)
This manual is for qualified personnel. An qualified personnel has been sufficiently trained and has proven capabilities and knowledge relating to the construction and operation of the device. An qualified personnel is trained to deal with the dangers and hazards involved in installing electrical systems.
Detailedinformationregardinginstallation,commissioning,maintenanceandtroubleshootingcanbe found in the inverter installation guide.
Further information about SMA America, LLC equipment is available in the download section of the www.SMA-America.com website. Among other things, the download area contains the following items:
•Information on communication between devices by Bluetooth Wireless Technology by SMA America, LLC in the "SMA Bluetooth Wireless Technology" technical description
•Information on detecting a free NetID in a Bluetooth network can be found in the Sunny Explorer user manual.
In this document, SMA America, LLC, and SMA Solar Technology Canada Inc. are hereinafter referred to as SMA.
The "RS485-Quick Module 485QMUS-10-NR" is referred to in the following as "RS485-Quick Module".
Installation Guide |
RS485-QM-IA-eng-IUS111610 |
9 |
Safety |
SMA America, LLC |
The RS485-Quick Module is provided as an upgrade kit or included in the scope of delivery of the inverter.
TheRS485-QuickModule is only suitablefor usewithSMAinverters oftypeSunnyBoy 2000HF-US / 2500HF-US / 3000HF-US. Please also observe the installation guide of the respective inverter.
TheRS485-QuickModuleallowsthesetupofacable-connectedRS485communicationbetweenthe aforementioned inverters.
The RS485-Quick Module has a multi-function relay that can serve as a fault signaling contact, amongst other things. The inverter will trip the fault signaling contact as soon as an error occurs.
DANGER
Danger to life due to high voltages in the inverter.
•Only qualified personnel may perform work on the inverter.
•Disconnect the inverter on the AC and DC side as described in the inverter's installation guide.
NOTICE
Electrostatic discharges can damage the RS485-Quick Module and the inverter.
• Ground yourself before touching a component part. Touch PE or a groundedobject.
10 |
RS485-QM-IA-eng-IUS111610 |
Installation Guide |