Seca 710 CN, 709 CN Service Manual

Service Manual
7097021004
Variants:
7097021994 7101021004 7101021994
for seca
Description: mechanical column scale with sliding weights
709 CN / 710 CN
Content:
Operation mod. 709 17-10-07-493 b Operation mod. 710 17-10-06-298 b
Service Manual Number
17-05-01-324-a
Valid as of:
Function diagram 25-01-02-582 Calibration 30-05-00-249 spare parts beam hood 30-05-00-250 a Spare parts baseframe 30-02-00-204 a
Manual number: 17-05-01-324-a
Service Manual Calibration instructions
seca 719/720
Drawing related to calibration instructions 30-05-00-249 Page 2
1. Sensitivity
The sensitivity is changed by adjusting the height of the counterweight (A), i.e. the fixing screws for the counterweight (A) are fitted with spacer plates. Take out or increase the number of spacer plates (A1) to change the sensitivity.
- Move the counterweight (A) up: the scale’s sensitivity is increased.
- Move the counterweight (A) down: the scale’s sensitivity is reduced.
2. Large sliding weight 0-190 kg (B)
- Set all weights to zero.
- Place a certain amount of lead on the scale’s zero point.
Use the taring spindle (C) to tare out the scale. Position the large sliding weight (B) at 190 kg (400lbs /29 sts). Place 190 kg (400lbs /29 sts) on the platform. Distribute the amount of lead placed on the zero point - certain amount at 0 kg, certain amount at 190 kg - (400lbs /29 sts) until the hood has reached an equilibrium. The lead positioned at 190 kg (400lbs /29 sts) must be placed in one of the empty chambers (B1) of the large sliding weight (B). The lead positioned at 0 kg/lbs/sts is not required.
2.2 Large sliding weight (B) too heavy
- A certain amount of lead must be drilled out of the empty chamber of the large sliding weight (B).
3. Small sliding weight (E) is not correct
- Add lead or shorten the lead seal to establish the equilibrium in the existing chamber (E1). Please proceed as described for steps 2.1 and 2.2.
06.04.04/Re Page 1 (2) 30-05-00-249