Scotsman SCN60PA1SS, SCN60PA1SU, SCN60GA1SS, SCN60GA1SU User Manual

0 (0)
Installation and User's Manual for
Residential Nugget Ice Machine
Model SCN60
Introduction
This manual includes information for the
installation, operation and maintenance of the
SCN60 residential ice machine.
The SCN60 was developed to offer fans of
ice in their homes. Previously Nugget Ice was only
available in commercial establishments, where it
developed a strong following because of the
chewable nature of the ice. This machine makes
authentic Nugget ice, using the same process as
the larger commercial machines.
May 2011
Page 1
SCN60
User's Manual
Table of Contents
Product Description: ...........................................Page 2
Cabinet Dimensions ...........................................Page 3
Location Recommendations: .......................................Page 4
Decorating Features: ...........................................Page 5
Door Panel Attachment ..........................................Page 6
Door Swing ................................................Page 7
Plumbing - Pump Model .........................................Page 8
Plumbing: Gravity Drain Model ......................................Page 9
Electrical and Start Up ..........................................Page 10
Use....................................................Page 11
Maintenance ...............................................Page 12
How to remove scale from the ice making system. ...........................Page 13
Outdoor Use Notice:
Keep from freezing. Severe damage will occur to the unit if left in or operated in temperatures beyond
the limits listed in this manual. That damage is NOT covered by warranty.
Keep dry
. Do not locate in low lying areas where puddles will accumulate.
Provide Shade
: Heat gain from the sun will reduce the unit's ability to make and store ice, and
ultraviolet radiation from the sun can potentially damage the unit's plastic components.
Water Supply
: Avoid a long run of hose or tubing exposed to the sun. Plastic water supply tubing
should be rated for potable water and include UV protection. Copper tubing is recommended.
Back Flow Prevention
: The unit includes back flow prevention, no additional check valve is required.
Drainage
: Do Not drain into swimming pool or onto grounds.
Product Description:
This ice machine is designed to be used indoors, in
a controlled environment or outdoors within certain
limits.
The SCN60 is made up of two major systems: the
ice making system and the ice storage system. The
ice making system is a continuous flow type ice
machine, it makes ice when the ice level becomes
low and stops when it is full.
The ice storage system is an insulated chest with a
drain at the bottom for melting ice. It is not
refrigerated, insuring that the bin contains fresh ice.
Installation Information
Dimensions:
The cabinet is fourteen and seven eighths inches
wide by thirty three and three eighths to thirty four
and three eighths inches high.
Utility and Operational Requirements
The SCN60 must be connected to a potable
water supply.
The water supply must have a conductivity of
at least 10 microSiemens/cm.
Minimum water pressure: 20 psi
Maximum water pressure: 80 psi
Minimum water temperature: 40 degrees F.
Maximum water temperature: 90 degrees F.
It is designed to operate in wide range of air
temperatures:
Minimum air temperature: 50 degrees F.
Maximum air temperature: 100 degrees F.
Although the machine will function within the listed
ranges, it works best at water temperatures
between 50 and 60 and air temperatures between
60 and 80.
Note: Ice making capacity goes down as the
environmental temperatures go up, and will be
severely reduced at temperatures over 90
o
F.
Operating a unit outside of the limits can cause
problems that are not covered by the warranty and,
if extreme, cause damage to the unit.
Water Quality
The water to the machine must be potable, or fit for
human consumption. Beyond that, water supplies
vary in the degree of mineral content. As this ice
machine makes ice, all the water that flows into the
machine is changed into ice. That includes any
minerals that might be in the water. However,
during ice making some minerals will stick to the
ice making components. The higher the mineral
content, the more mineral build up will occur. Water
filters are a partial help, as they will remove the
suspended solids, but water treatment is needed
for the dissolved solids, which are part of the water
and cannot be filtered out.
RO Water
This machine can be supplied with Reverse
Osmosis water, but the water conductivity must be
no less than 10 microSiemens/cm. A reverse
osmosis system should include post treatment or
blending to satisfy the R.O. water’s potential
aggressiveness.
Deionized water is not recommended and could
damage the machine.
Because water softeners exchange one mineral for
another, softened water may not improve water
conditions when used with ice machines
Electrical power
The unit must be on its own 115 volt, 60 Hz, 15
amp circuit. It is equipped with a power cord and
can be plugged into a nearby outlet. Extension
cords are not allowed by most codes. Follow all
applicable codes.
Warranty Information
Warranty information is supplied separately from
this manual. Refer to it for coverage. In general, the
warranty covers defects in materials or
workmanship and does not cover corrections of
installation errors or maintenance.
May 2011
Page 2
SCN60
User's Manual
Cabinet Dimensions
May 2011
Page 3
SCN60
User's Manual
14 7/8"
AIR IN
AIR OUT
3/4"
SHEET METAL DOOR FRONT - IF DOOR KIT INSTALLED
.63 MIN. CABINET DOOR
22"
29 1/4"
1"
LEG ADJUSTMENT
(4) PLACES
2 3/4"
2 3/8"
DOOR KIT
AND HANDLE
3/4"
4"
33 3/8" MIN.
34 3/8" MAX.
LEFT SIDE SVC.
ACCESS PANEL
2 1/2"
7 1/2"
3 1/4"
2 3/4"
5 1/8"
11 5/8"
115V
POWER CORD
DRAIN ACCESS - FLEXIBLE TUBING
3/8" I.D. PUMP MODEL (INCLUDED)
5/8" I.D. GRAVITY MODEL (NOT INCLUDED)
1/4" O.D. COPPER
WATER INLET
COMPRESSION
FITTING PROVIDED
3 7/8"
20 3/8"
FLOOR DRAIN
ACCESS HOLE
Scotsman Ice Systems are designed and manufactured with the highest regard for safety and
performance. They meet or exceed the standards of agencies like ETL.
Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that
have been altered in any way, including the use of any parts and/or other components not specifically
approved by Scotsman.
Scotsman reserves the right to make design changes and/or improvements at any time. Specifications
and designs are subject to change without notice.
Location Recommendations:
The machine can be built into a cabinet. It is an air
cooled refrigeration system and so air flows in and
out of it through the grill at the bottom front. The
grill must not be blocked by any covering door or
other obstruction.
There are two models, one is a gravity drain type
and it must have a building drain connection below
the level of the drain tube at the back of the
cabinet; the other is a pump drain model which can
force drain water up a maximum of 10 feet,
allowing it to be located where a gravity drain isn’t
available.
Kickplate Extension: In some situations the leg
levelers will be extended enough to become visible.
A kit to extend the kickplate over the legs is KKPF.
Cabinet Stability: In some free standing
installations it may be prudent to add a bracket that
secures the back of the cabinet to a wall. That kit
number is KATB.
Drain Conversion: A gravity drain model can be
converted to a drain pump model by installing a
drain pump kit. The drain pump kit consists of a
drain pump, wiring harness and associated tubing.
The part number is A39462-021.
Installation Notes
Built In Situations: If a finished floor is to be
installed in the area after the ice machine has been
built in, shims the expected thickness of the floor
should be installed under the unit to keep the
machine level with the planned floor level.
Note: The water connection is at the back and adds
a few inches to the cabinet depth.
Installations on a slab: Use a pump model and
pump the water to the point of drainage. Pump
models will pump 1 story (10 feet) high.
Installations over a crawl space or basement:
Either gravity drain or pump model units may be
used, if there is not enough room behind the
machine for a drain/waste receptacle, the drain will
have to be below the floor.
Note: When installed in a corner, the door swing
may be limited due to handle contact with the wall
or cabinet face.
All models require a water supply. Water supplies
vary in the degree of mineral content. High mineral
content water will require more frequent
maintenance. Water filtration may improve the
taste of the ice as well as cut down on some of the
mineral build up.
May 2011
Page 4
SCN60
User's Manual
Air Intake
Warm Air Out
Decorating Features:
The machine ships unfinished, allowing the
attachment of a decorator door panel or a metal
panel from Scotsman.
Door Panel
The ice machine is supplied without a conventional
door covering so it can be decorated to the user’s
preference. Scotsman offers several coverings
including white, black and stainless steel. In
addition, a custom built panel can be placed onto
the door.
Door Panels
: Finished door panels are available
from Scotsman for attachment to the machine, or a
custom panel can be made. The panel kits are:
Kit Number Panel Finish Handle Finish
KDFW White White
KDFWS White Stainless Steel
KDFB Black Black
KDFBS Black Stainless Steel
KDFS Stainless Steel Stainless Steel
Door Panel Attachment
To attach a Scotsman supplied panel:
Note: If door swing is to be changed, it must be
done before panel is attached.
The panel will be held on by 6 sheet
metal screws and 2 machine screws.
1. Remove the gasket and retain for
later use.
2. If the door panel is stainless steel,
remove any plastic covering the
stainless steel panel.
3. Place the panel onto the outside
of the door, and secure it to the door
using two machine screws, located
at the left center and right center.
4. Fasten the panel to the door using
the 6 sheet metal screws. In the
hinge area, use the outermost screw
holes.
5. Place the covers over the hinge areas, and
secure each cover to the door using a sheet metal
screw.
6. Insert hole plug over screw installed in step 5.
7. Return the gasket to its original position.
Custom Panel
A custom panel of wood or other material not
exceeding 15 lb can be attached to the door.
Attachment is from the ice side of the door. Holes
are provided in the door for this purpose.
See instructions in information packet to create and
attach a custom panel
May 2011
Page 5
SCN60
User's Manual
Hole Plug
Cover
Gasket
Loading...