Occupancy Sensors |
Wall Switch Occupancy Sensors
MSB Series
SPECIFICATIONS
Standards UL and cUL Lis ted; FCC part 15 (Class B) for Home a nd Oce Use
Input 120 or 277 Vac±10% 60 Hz
Output
Temperature 0 to 50 °C (32 to 122 °F)
Humidity Max. 90% RH non-condensing
Limited Warranty 1 year
Coverage Patterns
120 Vac, 1000 W max. tu ngsten incande scent load; 1000 VA
max. balla st load; ¼ HP max. motor l oad; 277 Vac; 1800 VA max.
ballast load
Top View
35 ft
(10.7m)
MSBP
EMPLOYS A LOW-ENERGY SWITCH CIRCUIT TO
MAXIMIZE CONTACT LIFE
FEATURES
• Adjustable time delay
• Bypass button for “always on” operability...simpilies commissioning
• 180-degree motion detection
• Line powered...no separate supply needed
• Compatible with magnetic and electronic ballasts...provides ultimate
exibility
• No minimum loading requirement
• Automatic ON/Automatic OFF or manual ON/Automatic OFF versions
• 300 square feet minor motion detection...improves
sensor accuracy
• Decorative faceplate
• Zero-voltage switching
• LED indication...provides visual sensor status
• Single-gang box mount...simplies installation
10 ft (3.1m)
15 ft (4.6m)
25 ft (7.6m)
Minor Motion
Major Motion
Side View
4 ft
(1.2m)
35 ft
(10.7m)
DESCRIPTION
The MSB Series employs the latest passive infrared (PIR) technology to
automatically control lighting for areas up to 1000 square feet, achieving
energy savings and convenience.
Each sensor employs a special 180° multi-segmented lens and PIR motion
detector circuit to sense when a person enters the area and automatically
activate the lights. The sensor will automatically switch the lights o after a
preset delay if motion is no longer detected.
The MSB Series ts in place of existing wall switches, connecting to existing
wiring, similar to a typical wall switch. The MSB Series is the simplest way to
achieve energy saving lighting control with minimal installation time.
To assure long relay life, the MSB Series employs a low energy switch
circuit to assure maximum contact life. These sensors are compatible with
electronic and magnectic ballast loads.
APPLICATIONS
• ighting control for LEED* programs and reduced energy usage
• Use in oces, copy rooms, common building areas, storage closets,
small conference rooms, and more
• Fits in place of existing wall switches connecting to the
existing active line and ground wiring...great for
retrot installations
*Leadership in Energy and Environmental Design (LEED) is a registered mark of the US
Green Building Council
TM
HQ0001802.E 0116
Occupancy Sensors | MSB Series
WIRING DIAGRAMS
Single Level Lighting
Neutral (WHT)
Ground (GRN)
Hot (BLK)
Bi-Level Lighting
Neutral (WHT)
Ground (GRN)
Hot (BLK)
LOAD
(RED)
(RED)
LOAD
LOAD
DIMENSIONAL DRAWING
4.2”
(107 mm)
1.8”
(46 mm)
1.3”
(33 mm)
4.5”
(114 mm)
2.8”
(69 mm)
ORDERING INFORMATION
Sensing Technology
P
MSB
= Passi ve Infr ared (P IR)
Turn On
A = Autom atic
M = Manua l
# of circuits
1
Color
W = White
V = Ivory
Example:
MSB P A 1 V