Schneider Electric ATV212 User Manual

Quick Start Guide - ATV212
ENGLISH
S1A5382502
1
8B0915316127
ATV212HU15N4
1.5KW - 2HP - 380 / 480V
2
3
(a) 50 mm (2 in.) (b) 100 mm (4 in.)
(c) 10 mm (0.4 in.)
(c)
ATV212H
ATV212W
(a)
(a)
(a)
(a)
(b) (b)
(a) (a)
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Read and understand this quick start guide before performing any procedure with this drive.
• The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all equipment.
• Many parts of this drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools.
• DO NOT touch unshielded components or terminal strip screw connections with voltage present.
• DO NOT short across terminals PA/+ and PC/- or across the DC bus capacitors.
• Before servicing the drive:
- Disconnect all power, including external control power that may be present.
- Place a "DO NOT TURN ON" label on all power disconnects.
- Lock all power disconnects in the open position.
- WAIT 15 MINUTES to allow the DC bus capacitors to discharge.
- Measure the voltage of the DC bus between the PA/+ and PC/- terminals to ensure that the voltage is less than 42 Vdc.
- If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate the drive.
• Install and close all covers before applying power or starting and stopping the drive.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this product.
Information below is designed to use single drive connected to single motor with a motor cable length less than 50 meters (164 ft). In any other case, consult the ATV212 installation manual (S1A53832) and programming manual (S1A53838) on www.schneider-electric.com. Check your cables before connecting the drive with motor (length, power, shielded or unshielded). Motor cable length is _______(< 50 meters, 164 ft).
• Remove ATV212 from the packaging and check that it has not been damaged.
WARNING
DAMAGED DRIVE EQUIPMENT
Do not operate or install any drive or drive accessory that appears damaged.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
• Check that the drive reference printed on the label is the same as that on the delivery note corresponding to the purchase order.
Write the drive Model Reference: _____________ ___________and Serial Number: ____________________________

Check the line voltage compatibility

• Check that the line voltage is compatible with the supply range of the drive. Line voltage _______ Volts Drive voltage range _______ Volts Drive range: ATV212 pppp M3X = 200 ... 240 V three-phase / ATV212 pppp N4p = 380 ... 480 V three-phase.

Mount the drive vertically

For a surrounding air temperature up to 40 °C (104 °F).
See installation manual (S1A53832) on www.schneider-electric.com for other thermal conditions.
www.schneider-electric.com 1/4 S1A53825 - 04/2011
4
RUN
PRG
MON
%
Hz
MODE
Loc Rem
ENT
RUN STOP
ATV 212 M3X
ATV 212 N4
380...400 V
200...240 V
or
Note: for ATV212H075ppp, ATV212HU15ppp, ATV212HU22ppp, to connect power, open the door, remove the terminal board, connect R/L1, S/L2 ,T/L3 and fix again the terminal board.
5
5.1
2.2 to 10 k
Ω
PP
CC
ATV 2 12
VIA
PP: Internal supply for
VIA: Analog/ logic input CC: Common
analogue inputs
F
ATV 212
RES
R
P24
F: Run forward R: Run reverse
F: Run forward
Control command 2-wire:
Control command 3-wire:
R: Stop RES: Run reverse P24: internal supply
P24: Internal supply
for logic inputs
for logic inputs
Do: + + +
9.1
5.2
Loc Rem
Do: + + +
6
Do: + + +
6
9.1
6
7
Run
mode
Hz
0..0

Connect the drive: Power

• Wire the drive to the ground.
• Check circuit breaker rating or fuse rating.
• Check that the motor voltage is compatible with the drive voltage. Motor voltage ______Volts.
• Wire the drive to the motor.
• Wire the drive to the line supply.
Connect the drive:
Control choice
[REMOTE configuration]
(Control by external reference)
• Wire the speed reference:
Wire the command:
0,6 N.m
5.3 lb.in

Apply power to the drive

• Check that used Logic Inputs are not active (see F, R, RES, P24, open circuit).
• Apply power to the drive.
• At each power on , drive displays HELLOmessage, then run mode :
ATV 2 12
F
P24
R
[LOCAL configuration]
(control by internal reference)
687
87
87
.
9.2

Set motor parameters

• See on the motor Nameplate to set the following parameters.
Menu Code Description Factory setting
Pt [Mot cont. mode sel.]: Motor control mode
AUF
[QUICK MENU]
uL
[EXTENDED MENU]
www.schneider-electric.com 2/4 S1A53825 - 04/2011
F---
uLu
F415
F417
F601
0[Constant V/Hz]: Constant V/Hz 1
[Variable Torque]: Variable torque
2[Cst V/Hz+Boost]: Constant V/Hz with automatic torque boost 3[SVC]: Sensorless vector control 4[Economy]: Energy saving
[Motor rated Freq.]:
Nominal motor frequency on motor nameplate (Hz)
[Motor Rated Voltage]:
Nominal motor voltage on motor nameplate (V)
[Motor rated current]:
Nominal motor current on motor nameplate (A)
[Motor rated speed]:
Nominal motor speed on motor nameplate (rpm)
[Motor Current Limit]:
Limit current during motoring or braking (%)
1
50.0
drive rating
drive rating
drive rating
110
Customer setting
Loading...