Draining climate control system
318 045
1
2
3
4
5
SUC
DIS
Components of the AC system:
1. Compressor
2. Condenser
3. Dehydrator
4. Expansion valve
5. Evaporator
6. Maintenance valve, High pressure DIS
General
Applies to refrigerant R134a
Wear protective gloves and goggles.
Welding, smoking or heating are not allowed if there is refrigerant present in the air.
Refrigerant generates a very toxic gas when heated.
Tools
Examples of suitable tools from Scania:
Part number Designation
588 431 Recycling station
General
Work description
1. Remove the protective caps from the maintenance valves and connect recycling
station 588 431 to the high pressure and low pressure sides. The maintenance
valves for the high and low pressure sides are of different dimensions and require
different size quick release couplings.
2. Drain the refrigerant (R134a) slowly.
Refrigerant must not be released into the atmosphere but must be recycled according
to local regulations.