Rockwell Automation 1761-L10BWA, 1761-L16AWA, 1761-L10BWB, 1761-L10BXB, 1761-L16BWA Installation Instructions Manual

...
Installation Instructions
MicroLogix™ 1000 Programmable Controllers
Catalog Numbers 1761-L10BWA, -L10BWB, -L10BXB, -L16AWA, -L16BWA,
-L16BWB, -L16BBB, -L16NWA, -L16NWB, -L20AWA-5A, -L20BWA-5A,
-L20BWB-5A, -L32AAA, -L32AWA, -L32BWA, -L32BWB, -L32BBB
http://literature.rockwellautomation.com/idc/groups/literature/documents/in/ 1761-in001_-mu-p.pdf
Questa pubblicazione è disponibile in Italiano in formato PDF. Per scaricarla collegarsi al sito Web indicato sopra.
Diese Publikation ist als PDF auf Deutsch verfügbar. Gehen Sie auf die oben genannte Web-Adresse, um nach der Publikation zu suchen und sie herunterzuladen.
Esta publicación está disponible en español como PDF. Diríjase a la dirección web indicada arriba para buscar y descarga esta publicación.
Esta publicação está disponível em portugués como PDF. Vá ao endereço web que aparece acima para encontrar e fazer download da publicação.
FR
IT
DE
ES
PT
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
Installation Instructions
MicroLogix™ 1000 Programmable Controllers
Catalog Numbers 1761-L10BWA, -L10BWB, -L10BXB, -L16AWA, -L16BWA,
-L16BWB, -L16BBB, -L16NWA, -L16NWB, -L20AWA-5A, -L20BWA-5A,
-L20BWB-5A, -L32AAA, -L32AWA, -L32BWA, -L32BWB, -L32BBB
Topic Page
Important User Information 4 Overview 5 Catalog Number Detail 5 Related Publications 6 Safety Considerations 7 Physical Dimensions 9 Mounting Your Controller Horizontally 10 Wiring Your Controller 13 Grounding Your Controller 15 Surge Suppression 16 Sinking and Sourcing 19 Wiring Your Analog Channels 20 Specifications 21
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
4 MicroLogix™ 1000 Programmable Controllers
Publication 1761-IN001C-EN-P - March 2008
Important User Information
Because of the variety of uses for the products described in this publication, those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. In no event will Allen-Bradley be responsible or liable for indirect or consequential damage resulting from the use or application of these products.
Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication.
Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.
Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited.
Throughout this publication, notes may be used to make you aware of safety considerations. The following annotations and their accompanying statements help you to identify a potential hazard, avoid a potential hazard, and recognize the consequences of a potential hazard:
WARNING
!
Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
ATTENTION
!
Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
MicroLogix™ 1000 Programmable Controllers 5
Publication 1761-IN001C-EN-P - March 2008
Overview
Install your controller using these installation instructions. The only tools you require are a Flat head or Phillips head screwdriver and drill.
Catalog Number Detail
The catalog number for the controller is composed of the following:
IMPORTANT
Identifies information that is critical for successful application and understanding of the product.
1761 - L 20 A W A - 5 A
Analog I/O
Number of Analog I/O: 4 Inputs, 1 Output
Power Supply A = 120/240V ac B = 24V dc
Output Type: A = Triac B = 24V dc FET W = Relay X = Relay/24V dc FET
Bulletin Number
Controller
Number of Digital I/O
Input Type:
A = 120V ac
B = 24V dc
N = 24V ac or 24V dc
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
6 MicroLogix™ 1000 Programmable Controllers
Publication 1761-IN001C-EN-P - March 2008
For More Information
Related Publications
If you would like a manual, you can:
download a free electronic version from the internet:
http://literature.rockwellautomation.com
purchase a printed manual by contacting your local Allen-Bradley distributor
or Rockwell Automation representative
For Refer to this Document Pub. No.
A description on how to use your MicroLogix 1000 programmable controllers. This manual also contains status file data and instruction set information.
MicroLogix 1000 Programmable Controllers User Manual
1761-6.3
A procedural manual for technical personnel who use the Allen-Bradley Hand-Held Programmer (HHP) to monitor and develop control logic programs for the MicroLogix 1000 controller.
MicroLogix 1000 with Hand-Held Programmer (HHP) User Manual
1761-6.2
More information on proper wiring and grounding techniques.
Industrial Automation Wiring and Grounding Guidelines
1770-4.1
The procedures necessary to install and connect the AIC+ and DNI.
Advanced Interface Converter (AIC+) and DeviceNet Interface (DNI) Installation Instructions
1761-5.11
A more detailed description on how to install and use your AIC+ Advanced Interface Converter.
AIC+ Advanced Interface Converter User Manual
1761-6.4
A more detailed description on how to install and use your DeviceNet Interface.
DeviceNet Interface User Manual 1761-6.5
A more detailed description on how to install and use your Ethernet Interface.
Ethernet Interface User Manual 1761-UM006
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
MicroLogix™ 1000 Programmable Controllers 7
Publication 1761-IN001C-EN-P - March 2008
Safety Considerations
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only (when product or packing is marked).
Use only the following communication cables in Class I, Division 2, Hazardous Locations.
WARNING
!
Explosion Hazard:
Substitution of components may impair suitability for Class
I, Division 2.
Do not replace components or disconnect equipment
unless power has been switched off and the area is known to be non-hazardous.
Do not connect or disconnect connectors while circuit is
live unless area is known to be non-hazardous.
This product must be installed in an enclosure. All cables
connected to the product must remain in the enclosure or be protected by conduit or other means.
Environment Classification Communication Cable
Class I, Division 2, Hazardous Environment 1761-CBL-PM02 Series C
1761-CBL-HM02 Series C 1761-CBL-AM00 Series C 1761-CBL-AP00 Series C 2707-NC8 Series B 2707-NC9 Series B 2707-NC10 Series B 2707-NC11 Series B
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
8 MicroLogix™ 1000 Programmable Controllers
Publication 1761-IN001C-EN-P - March 2008
Sécurité
Cet équipement est conçu pour être utilisé dans des environnements de Classe 1, Division 2, Groupes A, B, C, D ou non dangereux (si indiqué sur le produit ou l'emballage).
N'utiliser que les câbles de communication suivants dans des environnements dangereux de Classe 1, Division 2.
AVERTISSEMENT
!
Danger d'explosion :
La substitution de composants peut rendre cet
équipement impropre à une utilisation en environnement de Classe 1, Division 2.
Ne pas remplacer de composants ou déconnecter
l'équipement sans s'être assuré que l'alimentation est coupée et que l'environnement est classé non dangereux.
Ne pas connecter ou déconnecter les connecteurs lorsque
le circuit est alimenté, à moins que l'environnement ne soit classé non dangereux.
Ce produit doit être installé dans un boîtier. Tous les
câbles qui lui sont connectés doivent rester dans le boîtier ou être protégés.
Classification d'environnement Câble de communication
Environnement dangereux Classe 1, Division 2 1761-CBL-PM02 Série C
1761-CBL-HM02 Série C 1761-CBL-AM00 Série C 1761-CBL-AP00 Série C 2707-NC8 Série B 2707-NC9 Série B 2707-NC10 Série B 2707-NC11 Série B
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
MicroLogix™ 1000 Programmable Controllers 9
Publication 1761-IN001C-EN-P - March 2008
Physical Dimensions
Controller Spacing
The following figure shows the recommended minimum spacing for the controller.
Note: The controller is shown horizontally mounted.
Controller: 1761- Length: mm (in.) Depth: mm (in.) Height: mm (in.)
L10BWA 120 (4.72) 73 (2.87) 80 (3.15) L16BWA L16NWA L16AWA 133 (5.24) L20AWA-5A 200 (7.87) L20BWA-5A L32AWA L32BWA L32AAA L10BWB 120 (4.72) 40 (1.57) L10BXB L16BBB L16BWB L16NWB L20BWB-5A 200 (7.87) L32BBB L32BWB
B
A
B
A
A. Greater than or equal to 50.8 mm (2 in.)
B. Greater than or equal to 50.8 mm (2 in.)
Top
Bottom
SideSide Side
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive
10 MicroLogix™ 1000 Programmable Controllers
Publication 1761-IN001C-EN-P - March 2008
Mounting Your Controller Horizontally
The controller should be mounted horizontally within an enclosure using either the DIN rail or mounting screw option. Use the mounting template from the front of this document to help you space and mount the controller properly.
Using a DIN Rail
To install your controller on the DIN rail:
1. Mount your DIN rail. (Make sure that the
placement of the controller on the DIN rail meets the recommended spacing requirements. Refer to the mounting template from the back of this document.)
2. Hook the top slot over the DIN rail.
3. While pressing the controller against the rail,
snap the controller into position.
4. Leave the protective wrap attached until you
are finished wiring the controller.
ATTENTION
!
Be careful of metal chips when drilling mounting holes for your controller. Drilled fragments that fall into the controller could cause damage. Do not drill holes above a mounted controller if the protective wrap is removed.
Mounting Templa te
Protective Wrap
DIN Rail
Side View
A
B
C
Call-out Dimension
A 84 mm (3.3 in.) B 33 mm (1.3 in.) maximum C 16 mm (0.63 in.)