RISCO Group LightSYS 2 User Manual

up to 50 zones
Installation Supplement
Firmware Version 3.0x and above
Live IP Video Verification Solution for LightSYS 2
LightSYS 2 supports VUpoint – RISCO’s revolutionary, live video verification solution for residential and commercial installations that seamlessly integrates an unlimited number of IP cameras for providing an unprecedented level of security and live video monitoring capabilities to alarm receiving centres and end-users alike.
VUpoint offers seamless integration of LightSYS 2 with IP cameras
A unique solution, offering live video verification of alarms for alarm receiving
centres, business & home owners
Live video on-demand for business & home owners
Note: VUpoint may be added to any LightSYS 2 system connected to the RISCO Cloud, and is not dependant on the firmware version installed.
VUpoint Indoor Cube IP Camera VUpoint Outdoor Bullet IP Camera
Powered by the RISCO Cloud, VUpoint enables live video streaming from IP cameras to be viewed “on-demand” using the iRISCO Smartphone or Web application. VUpoint can be configured so that any event—intrusion, safety or panic—can activate the IP camera.
For verification purposes, live viewing of video of events can greatly assist alarm receiving centres in identifying costly false alarms, and enable a greater operational efficiency.
Download the iRISCO app from the Apple Store for iOS devices and the Play Store for Android devices. For more information contact your RISCO Distributor or go to
www.riscogroup.com/uk
Summary of Version 3.0x Enhancements
This section describes the product enhancements available for LightSYS 2, firmware version
3.0 and above.
LightSYS 2 version changes were made in consideration of market requirements and improvements to the product.
NOTE: The changes pertain only to expanded system capabilities, and do not entail changes to the instructional procedures contained in the manuals
.
Table of Expanded System Capabilities
LightSYS 2
Capability
Firmware versions lower
than 3.0
Total Maximum Zones
Any combination of wired, wireless or bus zones as specified below:
Wired Zones Up to 32
Wireless Zones
(1-way or 2-way)
Bus Zones Up to 32 Up to 32
User codes & tags Up to 16 user codes & tags Up to 30 user codes & tags
Programmable outputs Up to 14 outputs Up to 32 outputs
Zone expander modules
Output expander modules
(either 4 or 8 outputs each)
32
Up to 32 Up to 50
Up to 3 modules
(8 zones each)
Up to 4 modules
LightSYS 2
Firmware versions 3.0
and above
50
Up to 50
Up to 5 modules
(8 zones each)
Up to 6 modules
(either 4 or 8 outputs each)
*
* To connect 50 relay detectors, use single zone expanders (RP128EZ01) on zones 9 & 10, and
then add five 8 zone expanders (RP432EZ08) to reach 50 zones
Enhanced Features above Grade 2 Requirements
By default, LightSYS 2 is configured to Grade 2. In order to invoke enhanced security features above Grade 2, go to:
Installer MenuProgramming1)System5)Settings4)Standard4)EN 50131
NOTE: This will invoke a default of the system parameters.
The following table details the parameter configurations to invoke enhanced security features above Grade 2:
Item Grade 2 Enhanced
Features
USER CODES 4 digits 6 digits
ANTI CODE RESET 4 digits 6 digits
NOTE: changing the number of code digits will
require re-defining all current user codes.
EVENT LOG 250 events 500 events LightSYS2 always supports 512 events
For enhanced mode, the system control bit “ENGR. TAMPER” shall be defined as YES.
Menu = [Programming][System][Controls][Advanced]
INSTALLER TAMPER
Not required
YES: A Tamper event causes a Lockout condition
which can only be reset by the Installer code or by Anti-Code.
NO: A Tamper event does not cause a Lockout
condition
For enhanced mode, the system control bit “Rest Trouble” shall be defined as YES.
Menu = [Programming][System][Controls][EN50131]
YES: A System Trouble condition must be
acknowledged by the user
NO: A System Trouble condition will reset
automatically when clear
TROUBLE RESET
Not required
For enhanced mode, triple end-of-line termination is supported to identify detector masking and trouble (trouble for all Grades).
DETECTOR MASK AND TROUBLE
Not required
For enhanced mode, 10 invalid code entry attempts
INHIBIT KEYPAD
DUAL PATH ARMING PREVENTION
Not required
Required
will lock the keypad for 90 seconds (relevant for all user codes and operations – arming, disarming, etc.)
If there is a communication fault with the monitoring station (by PSTN, TCP/IP, GSM, or STU) the panel will not be ready to arm.
Explanation
TRIPLE EOL ZONE INPUT
© RISCO Group, 12/2014. All rights reserved. 5IN2164 C