Quadra-Fire QV32-A, QV36-A User Manual

Models: QV32-A QV36-A
WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS­ING PROPERTY DAMAGE, PER­SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam­mable vapors and liquids in the vicinity of this or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Installers Guide
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA­TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM­AGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFOR­MATION CONSULT A QUALIFIED IN­STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.
1. This appliance may be installed in an af­termarket, permanently located, manufac­tured (mobile) home, where not prohibited by local codes.
2. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Aladdin Hearth Products 1445 N. Hwy. 395 Colville, WA 99114
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Printed in U.S.A. Copyright 2002
Please contact your Aladdin Hearth Products dealer with any questions or concerns. For the number of your nearest Aladdin Hearth Products dealer, please call 1-800-234-2508.
291-982E 9/02
1
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND all instructions carefully
!
before starting the installation. FAILURE TO FOLLOW these installation instructions may result
in a possible fire hazard and will void the warranty.
Prior to the first firing of the fireplace, READ the
!
Using Your Fireplace section of the Owners Guide.
DO NOT USE this appliance if any part has been
!
under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
!
Installation and repair should be PERFORMED by a qualified service person. The appliance and venting
!
system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.
These units MUST use one of the vent systems described in the Installing the Fireplace section of
!
the Installers Guide. NO OTHER vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be
!
vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to
!
make sure that no debris is interfering with the air flow.
The glass door assembly MUST be in place and
!
sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass
!
door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.
Always KEEP the appliance clear and free from
!
combustible materials, gasoline, and other flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and
!
ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.
Due to the high temperature, the appliance should be LOCATED out of traffic areas and away from
!
furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the
!
hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.
The glass door assembly SHALL ONLY be
!
replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.
DO NOT USE abrasive cleaners on the glass door
!
assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qualified service technician
!
perform an appliance check-up at the beginning of each heating season.
Any safety screen or guard removed for servicing
!
must be replaced before operating this appliance.
DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace
!
front.
2

TABLE OF CONTENTS

Safety and Warning Information ..........................................................2
Service Parts Lists ..................................................................................4
u
Section 1: Approvals and Codes ...........................................................8
Appliance Certification...............................................................................8
Installation Codes ......................................................................................8
High Altitude Installations ..........................................................................8
Section 2: Getting Started .....................................................................9
Introducing the Village Collection Gas Fireplaces .....................................9
u
Pre-installation Preparation .......................................................................9
Section 3: Installing the Fireplace......................................................12
Constructing the Fireplace Chase ...........................................................12
u
Step 1 Locating the Fireplace ............................................................12
Step 2 Framing the Fireplace ............................................................13
Step 3 Installing the Vent System .....................................................16
A. Vent System Approvals ....................................................16
B. Installing Vent Components ..............................................26
C. Vent Termination ...............................................................29
u
Step 4 Positioning, Leveling, and
Securing the Fireplace ...........................................................32
Step 5 The Gas Control Systems ......................................................32
Step 6 The Gas Supply Line.............................................................. 33
Step 7 Gas Pressure Requirements ..................................................33
Step 8 Wiring the Fireplace ...............................................................34
Step 9 Finishing.................................................................................35
Refractory Kit Placement ....................................................... 35
Step 10 Installing Trim, Logs, and Ember Material.............................. 36
Installing the Trim ...................................................................36
Shutter Settings .....................................................................36
Placing the Ember Material.................................................... 36
Step 11 Before Lighting the Fireplace..................................................37
Step 12 Lighting the Appliance ............................................................38
After the Installation.................................................................................38
Section 4: Maintaining and Servicing Your Fireplace.....................39
Section 5: Troubleshooting.................................................................40
Limited Lifetime Warranty........................................................................42
u = Contains updated information.
3
Service Parts
u
QV32-A (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces
4
1
5
2
7
16
6
8 Log Set Assembly
3
12
9
Part number list on following page.
*
La liste des numéros de pièce se trouve
* à la page suivante.
13
10
15
4
11
14
QV32-A (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM / PIÈCE
STANDING PILOT IGNITION / D’ALLUMAGE PAR VEILLEUSE
On/Off Rock Switch / Interupter a bascule marche/arret 060-511 Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle 302-320A Piezo Ignitor / Allumage Piézo 291-513 Burner Tube / Tube de brûleur 567-301A
Burner Orifice NG (#38C) / Orifice de brûleur GN (#38C) 582-838 Burner Orifice LP (1.55mmC) / Orifice de brûleur PL (1.55mmC) 582-8155
1 Andirons, Cast / Andirons, le Moule 80784 2 Burner NG / Brûleur GN 544-142A 2 Burner LP / Brûleur PL 557-132A 3 Glass Door Assembly / Porte en verre GLA-550TRS
4 Log Grate / Grille de Bûche 293-360A 5 Base Refractory NG, LP / Réfractaire Base NG, PL 296-124
6 Refractory Kit (Sold as set only) / Réfractaire Kit (A vendu comme régler seulement) BRICK-293 7 Junction Box / Boîtier de raccordement 100-250A 8 Log Set Assembly / Module de Jeu de Bûches LOGS-296 9 Log 1 / Bûche 1 SRV545-710
10 Log 2 / Bûche 2 SRV536-705
11 Log 3 / Bûche 3 SRV536-706 12 Log 4 / Bûche 4 SRV536-704 13 Log 5 / Bûche 5 SRV536-718 14 Log 6 / Bûche 6 SRV446-715 15 Log 7 / Bûche 7 SRV484-705 16
Valve Assembly NG / Module de valve GN
16
Valve Assembly LP / Module de valve PL Valve NG / Valve GN 060-522
Valve LP / Valve PL 060-523 Pilot Assembly NG / Module de veilleuse GN 485-510A Pilot Assembly LP / Module de veilleuse PL 485-511A Pilot Orifice NG / Orifice de veilleuse GN 446-505 Pilot Orifice LP / Orifice de veilleuse PL 446-517
Thermocouple / Thermocouple 446-511 Thermopile / Thermopile 060-512
Pilot Control Knob / Piloter le Bouton de Contrôle 291-530 Flame Control Knob / Flamber le Bouton de Contrôle 291-531
ACCESSORIES / ACCESSOIRES
Fan Kit / Module de ventilateur GFK-160A Wall Switch Kit, Off-white / Module d'interrupteur mural, Blanc Cassé WSK-21-HTI Wall Switch Kit, White / Module d'interrupteur mural, Blanc WSK-21-W-HTI Conversion Kit NG / Module de conversion GN NGK-293 Conversion Kit LP / Module de conversion PL LPK-293 Door Front - Remington Ave. DF-32RA-BK Door Front - Remington Ave. DF-32RA-HP Door Front - Sun Prairie DF-32SP-BK Door Front - Sun Prairie DF-32SP-HP Door Front - Town Square DF-32TS-BK Door Front - Town Square DF-32TS-HP
Hood, Black / Hotte, Noir SRV550-175 Hood, Hammered Pewter / Hotte, Pewter SRV550-175-HP
PART NUMBER
/ N° DE PIÈCE
291-106A 291-105A
5
Service Parts
u
QV36-A (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
4
1
2
5
7
3
Part number list on following page.
*
La liste des numéros de pièce se trouve à la
* page suivante.
6
8 Log Set Assembly
15
14
11
16
9
12
13
10
6
QV36-A (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DA TED INFORMATION. The most current information is located on your dealers VIP site. When order-
ing, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM / PIÈCE
STANDING PILOT IGNITION / D’ALLUMAGE PAR VEILLEUSE
PART NUMBER
/ N° DE PIÈCE
On/Off Rocker Switch / Interrupteur a bascule marche/arret 060-511 Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle 302-320A Piezo Ignitor / Allumage Piézo 291-513 Burner Tube / Tube de brûleur 567-301A Burner Orifice NG (#36C) / Orifice de brûleur GN (#36C) 582-836 Burner Orifice LP (#52C) / Orifice de brûleur PL (#52C) 582-852
1 Andirons, Cast / Andirons, le Moule 80784 2 Burner NG / Brûleur GN 537-142A 2 Burner LP / Brûleur PL 537-132A 3 Glass Door Assembly / Porte en verre GLA-750TRS 4 Log Grate / Grille de Bûche 293-360A 5 Base Refractory NG, LP / Réfractaire Base NG, PL 294-124 6 Refractory Kit (Sold as set only) / Réfractaire Kit (A vendu comme régler seulement) BRICK-291 7 Valve Assembly NG / Module de valve GN 291-106A 7 Valve Assembly LP / Module de valve PL 291-105A 8 Log Set Assembly / Module de Jeu de Bûches LOGS-291 9 Log 1 / Bûche 1 SRV537-134
10 Log 2 / Bûche 2 SRV537-135
11 Log 3 / Bûche 3 SRV544-707 12 Log 4 / Bûche 4 SRV544-704 13 Log 5 / Bûche 5 SRV446-715 14 Log 6 / Bûche 6 SRV537-718 15 Log 7 / Bûche 7 SRV537-705 16 Junction Box / Boîtier de raccordement 100-250A
Valve NG / Valve GN 060-522
Valve LP / Valve PL 060-523 Pilot Assembly NG / Module de veilleuse GN 485-510A Pilot Assembly LP / Module de veilleuse PL 485-511A Pilot Control Knob / Piloter le Bouton de Contrôle 291-530 Flame Control Knob / Flamber le Bouton de Contrôle 291-531 Pilot Orifice NG / Orifice de veilleuse GN 446-505 Pilot Orifice LP / Orifice de veilleuse PL 446-517
Thermocouple / Thermocouple 446-511
Thermopile / Thermopile 060-512
ACCESSORIES / ACCESSOIRES
Fan Kit / Module de ventilateur GFK-160A
Wall Switch Kit, Off-white / Module d'interrupteur mural, Blanc Cassé WSK-21-HTI
Wall Switch Kit, White / Module d'interrupteur mural, Blanc WSK-21-W-HTI
Conversion Kit NG / Module de conversion GN NGK-291
Conversion Kit LP / Module de conversion PL LPK-291 Door Front - Town Square DF-36TS-BK Door Front - Town Square DF-36TS-HP Door Front - Sun Prairie DF-36SP-BK Door Front - Sun Prairie DF-36SP-HP Door Front - Remington Avenue DF-36RA-BK Door Front - Remington Avenue DF-36RA-HP Door Front - Remington Place DF-36RP-BK Door Front - Remington Place DF-36RP-HP Door Front - Chapel Hill DF-36CH-BK Door Front - Chapel Hill DF-36CH-HP Hood, Black / Hotte, Noir SRV60-143-BK Hood, Hammered Pewter / Hotte, Pewter SRV60-143-HP
7
Approvals and Codes
Appliance Certification
The Village Collection fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
Certification
MODELS: QV32-A, QV36-A LABORATORY: Underwriters Laboratories TYPE: Vented Gas Fireplace Heater STANDARD: ANSI Z21.88•CSA2.33•UL307B
NOTE: THESE MODELS ARE UL LISTED TO UL307B, THE STANDARD FOR GAS-BURNING HEATING APPLI­ANCES FOR MANUFACTURED HOMES AND RECRE-
ATIONAL VEHICLES.
Installation Codes
The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.
High Altitude Installations
U.L. Listed gas fireplaces are tested and approved for elevations from 0 to 2,000 feet in the U.S.A. and from 0 to 4,500 feet in Canada.
When installing this fireplace at an elevation above 2,000 feet (in the United States), it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should be reduced four percent (4%) for each 1,000 feet above sea level, unless the heating value of the gas has been reduced, in which case this general rule will not apply. To identify the proper orifice size, check with the local gas utility.
When installing this fireplace at an elevation between 2,000 and 4,500 feet (in Canada), the input rating must be reduced by ten percent (10%).
When installing this fireplace at an elevation above 4,500 feet (in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper orifice for your location.
In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA-B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada).
These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.
8
Getting Started
Introducing the Village Collection Gas Fireplaces
The Village Collection direct vent gas fireplaces are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas control systems. Gas fireplace diagrams, including the dimensions, are shown in this section.
Pre-install Preparation
This gas fireplace and its components are tested and safe when installed in accordance with this Installers Guide. Report to your dealer any parts damaged in shipment, particularly the condition of the glass. Do not install any
unit with damaged, incomplete, or substitute parts.
The vent system components and trim doors are shipped in separate packages. The gas logs are packaged separately and must be field installed.
Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. Failure to follow these instructions will void the owner’s warranty and may present a fire hazard.
The Aladdin Hearth Products Warranty will be voided by, and Aladdin Hearth Products disclaims any responsibility for, the following actions:
Installation of any damaged fireplace or vent system component.
Modification of the fireplace or direct vent system.
Installation other than as instructed by Aladdin Hearth Products.
Improper positioning of the gas logs or the glass door.
Installation and/or use of any component part not manu­factured and approved by Aladdin Hearth Products, not withstanding any independent testing laboratory or other party approval of such component part or accessory.
ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD.
When planning a fireplace installation, it’s necessary to determine:
Where the unit is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical wiring.
Framing and finishing details.
Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
If the fireplace is to be installed on carpeting or tile, or on any combustible material other than wood flooring, the fireplace should be installed on a metal or wood panel that extends the full width and depth of the fireplace.
9
GAS
ACCESS
22
(560mm)
34 1/2
(876mm)
3 1/2
(90mm)
8 (203mm)
26 7/8
(683mm)
8 5/8
(219mm)
COLLARS
DIAMETER
ELECTRICAL
15 3/8 (390mm)
30 3/4 (781mm)
16 1/4 (413mm)
GAS
LINE
ACCESS
2 1/4 (56mm)
5 3/8 (138mm)
6 5/8 (168mm)
VENT COLLARS
37 3/4
(960mm)
DIAMETER
36
(913mm)
41 (1040mm)
8 3/4 (222mm)
VENT
ACCESS
TOP
STANDOFFS
u
GAS
RATING PLATE/
LABELS
Figure 1. Diagram of the QV36-A
CONTROLS
ELECTRICAL
ACCESS
10
8
(203mm)
23 3/8
(594mm)
(219mm)
COLLARS
DIAMETER
ELECTRICAL
(913mm)
(788mm)
(468mm)
(786mm)
(826mm)
12 7/8
GAS
ELECTRICAL
(327mm)
25 3/4 (653mm)
16 1/4 (413mm)
GAS LINE
ACCESS
2 1/4
(56mm)
5 3/8
(138mm)
6 5/8 (168mm)
32 1/2
DIAMETER
VENT COLLARS
31
36
8 3/4 (222mm)
TOP
STANDOFFS
18 3/8
8 5/8
VENT
ACCESS
31
3 1/2
(90mm)
u
GAS
ACCESS
RATING PLATE/
LABELS
Figure 2. Diagram of the QV-32-A
CONTROLS
ACCESS
11
Installing the Fireplace
C
3” MIN. (76mm)
BDE
Constructing the Fireplace Chase
A chase is a vertical box-like structure built to enclose the gas fireplace and/or its vent system. Vertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase.
CAUTION: TREA TMENT OF FIRESTOP SPACERS AND CONSTRUCTION OF THE CHASE MA Y VARY WITH THE TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL BUILDING CODES. THEREFORE, YOUR LOCAL BUILD­ING CODES MUST BE CHECKED TO DETERMINE THE REQUIREMENTS FOR THESE STEPS.
A
1/2 “ MIN. (13mm)
A B C D E
QV36-A 42” 16 1/4” 31 7/8” 45” 63 3/4” QV32-A 37” 16 1/4” 29 3/8” 41 1/2” 58 3/4”
Factory-built fireplace chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner.
This means that the walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltra­tion barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, Aladdin Hearth Products recommends that the inside surfaces be sheet­rocked and taped for maximum air tightness.
To further prevent drafts, the firestops should be caulked to seal gaps. Gas line holes and other openings should be caulked or stuffed with insulation. If the unit is being in­stalled on a cement slab, we recommend that a layer of plywood be placed underneath to prevent conducting cold up into the room. Be sure to include spark arrestors for woodburning units if they are required.
THE CHASE SHOULD BE CONSTRUCTED SO THA T ALL CLEARANCES TO THE FIREPLACE ARE MAINT AINED AS SPECIFIED WITHIN THIS INSTALLERS GUIDE.
Step 1. Locating the Fireplace
The following diagram shows space and clearance require­ments for locating a fireplace within a room.
Clearance Requirements
The top and back of the fireplace are defined by stand-offs. The minimum clearance to a perpendicular wall extending past the face of the fireplace is 3 inches (76mm). The back of the fireplace may be recessed 16 1/4 inches (413mm) into combustible construction.
Figure 4. Fireplace Dimensions, Locations, and Space Requirements
Minimum Clearances
from the Fireplace to Combustible Materials
Inches mm
Glass Front ......................................36 ........ 914
Floor ..................................................0........... 0
Rear ................................................. 1/2 ........ 13
Sides ............................................... 1/2 ........ 13
Top (QV-36)....................................3 1/4....... 83
(QV-32) ...................................1 1/2....... 38
Ceiling* .............................................31 ........ 787
* The clearance to the ceiling is measured from the top
of the unit, excluding the standoffs (see Figure 38).
The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the com­bustible construction, NOT from the screw heads that se­cure the unit together.
Minimum Clearances
from the Vent Pipe to Combustible Materials
Inches mm
Vertical Sections...............1................. 25
Horizontal Sections
Top ......................................3................. 75
Bottom................................ 1................. 25
Sides .................................. 1................. 25
At Wall Firestops
Top ...................................2 1/2.............63.7
Bottom.............................. 1/2 ............... 13
Sides .................................. 1................. 25
For minimum clearances, see the direct vent termination clearance in Figures 30 and 31.
12
ABC
Step 2. Framing the Fireplace
NON-COMBUSTIBLE ZONE
3
Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommo­date wall coverings and fireplace facing material. The dia­gram below shows framing reference dimensions.
IS DEFINED BY 3” ABOVE THE
ELBOW FOR THE ENTIRE
WIDTH AND DEPTH (BEHIND THE
FRONT HEADER) OF THE FIREBOX.
WALL STUD
3 1/2”
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING.
WARNING:
To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame.
VENT
Framing should be constructed of 2 X 4 lumber or heavier.
The framing headers may rest on the fireplace stand-offs.
*The center of the framing hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe.
Model A B C D E *
QV36-A 42” 38 1/4” 16 1/4” 41” 27 7/8” QV32-A 37” 33” 16 1/4” 36 1/2” 24 3/8”
FRAMING
HOLE
E
D
Figure 5. Framing Dimensions
u
13
Loading...
+ 29 hidden pages