Prince Castle DHB2-20CE Parts List

Page 1
OPERATING
INSTRUCTIONS
Dedicated Holding Bin DHB2-20CE & GB Series
Prince Castle Food Holding Bins provide the capacity re­quired for large foodservice operations while performing at peak energy efficiency. Each unit features two individually controlled holding chambers. New Reli-A-Temp™ infrared heater technology holds product temperatures more consis­tent within the designated holding time than other types of heating systems. This exclusive heater design spreads the heat evenly over the entire food holding area, eliminating edge drop off. Food is kept at the desired serving tempera­ture.
TABLE OF CONTENTS PAGE
Installation..................................................................... 2
Controller Identification ................................................ 2
Operation ....................................................................... 3
Programming................................................................. 3
Calibration & Cleaning ................................................. 4
Troubleshooting Guide ................................................. 5
Exploded View & Parts List ........................................ 6
Wiring Diagram ............................................................. 8
LIMITED WARRANTY
This product is warranted to be free from defects in material and/or workmanship for a period of 1 year from date of original installation, not to exceed 18 months from the date of manufacture.
Any component which proves to be faulty in material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts and labor. This warranty covers on-location service (i.e. trip charges and/or mileage). Travel mileage is limited to 100 miles (200 Kilometers) round trip (one trip warranty) from an authorized service agency or its sub-service agency.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this warranty.
• All labor to be performed during regular work hours. Overtime premium (the incremental amount) will be charged to the customer.
• Damage caused by carelessness, neglect and/or abuse (e.g., dropping, tampering or altering parts, equipment damaged in shipment, by fire, flood or an act of God) is not covered under this warranty.
• All problems due to operation at voltages other than that specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage is the customer’s responsibility.
• This equipment must be serviced by Prince Castle Authorized Service Agency or a Prince Castle Service Technician during the warranty period.
ELECTRICAL SPECIFICATIONS
DHB2-20CE DHB2-20GB
Voltage 220-240 240
Watts 2600 2600
Hertz 50 50
Amps 10.8 18.8
355 East Kehoe Blvd. Carol Stream, IL 60188
Tel: (630) 462-8800 ! Fax: (630) 462-1460
Toll Free: 1-800-PCASTLE
54 2-5 13r evB Printed i n USA 2/06 © 2006
!
Page 2
INSTALLATION
1. After you have removed the bin from the carton, inspect the unit for signs of damage. If there is damage to the unit:
! Notify carrier within 24 hours after delivery.
TEMPERATURE MODE FUNCTIONS
UPPER SHELF LED: When lit, indicates that the
temperature displayed is for one of the upper shelf heaters, a U will appear in the display for the upper heater, a L for the lower heater.
! Save carton and packaging materials for inspec-
tion purposes.
! Contact your local dealer, or if purchased
directly,the Prince Castle Customer Sales Depart­ ment at 1-800-722-7853 to arrange for a replace­ ment to be sent.
1. Verify that all parts have been received. A rack kit should be received with bin.
2. Remove all packaging and the white protective covering from the bin.
3. Insert the racks and pan covers into the appropriate heater compartment.
LOWER SHELF LED:When lit, indicates that the temperature displayed is for one of the lower shelf heaters, a U will appear in the display for the upper heater, a L for the lower heater.ACTUAL TEMP LED: When lit, indicates that the actual temperaure for the selected heater is displayed.
SET POINT LED: When lit, indicates that the Set Point Temeparure for the selected heater is dis­played.
PROG LED: When lit, indicates the controller is in the Program Mode.
HEAT LED: When lit, indicates that the selected heater is cycling on.
UP ARROW or DOWN ARROW: Pressing either button will allow the operator to select another heater assembly for display or programming pur­poses.
ACTUAL TEMP BUTTON: When pressed, the actual temperature for the selected heater will appear in the display.
CONTROL PANEL IDENTIFICATION
Program
LED
Up & Down
Actual Temp
Upper Shelf LED
Lower Shelf LED
Arrows
Button
Actual Temp LED
Set Point LED
Heat LED
Pan Timer Buttons
Set Point Button
SET POINT BUTTON: When pressed, the set point temperature for the selected heater will appear in the display.
SET POINT BUTTON and DOWN ARROW: When pressed simultaneously, will enter the program mode for changing the set point temperature for the se­lected heater assembly.
UP ARROW and DOWN ARROW: When pressed & held simultaneously, will switch controller from Temperature Mode to Time Mode or Time Mode to Temperature Mode.
PROGRAMMING TEMPERATURES
1. Turn on power switch.
2 54 2-5 13r evBPrinted in USA 2/06 © 2006
Page 3
2. Select heater that needs to be changed by pressing either the Up or Down arrow until the appropriate shelf LED (Upper or Lower) and the appropriate heater (U=Upper, L=Lower) appears in the display.
3. Press and hold the Set Point Button and then the the down arrow until the audio alarm beeps and
the LED next to ”Prog” is lit. The current program temperature will be in the display.
3. Press the appropriate Pan Timer Button. The red LED for the Pan Timer Button will flash and the programmed holding time for that product will begin to countdown. Note: All four Pan Timer Buttons are preset for 30 minutes. The countdown time will be displayed in hours and minutes, until the time reaches 10 minutes. At that point, the display will change to minutes and seconds.
4. If more than one Pan Timer Button is activated, the active pan timer with the least amount of countdown time remaining will flash its LED indicator and the time remaining will appear in the display. The other active pan timers will have a solid red LED.
5. Remove product from the pan as necessary.
6. At the end of the countdown sequence, an audio alarm will sound and the display will flash “END”. Press the Pan Timer Button with the flashing LED to cancel the audio alarm.
7. Remove that pan and discard the remaining product in it.
4. Press the up arrow to change the temperature.
5. Press the set point button to store the tempera­ture change.
Note: Pan Timers can only be activated or de­activated when the controller is in the Time Mode.
To Cancel An Active Pan Timer When Pan Is Empty:
Press the Pan Timer Button three times. The Pan Timer LED will shut off and the display will revert back to show the Pan Timer with the least amount of countdown time remaining.
To View The Remaining Countdown Time For An Active Pan Timer:
The countdown time for the pan timer with the least amount of time remaining will appear in the display. To view the time remaining for another active pan timer, press the pan timer button. The remaining countdown time for that pan timer will appear in the display. When the button is released the display will revert back to the least remaining countdown time.
To View the Actual Or Set Point Temperature For A Selected Heater:
6. Repeat steps 2-5 for the other heaters.
OPERATION
1. Press and hold both the UP ARROW and DOWN ARROW to change the controller to the Time
Mode. “----” will appear in the display.
2. Place a pan of product into the appropriate rack location.
54 2-5 13r evB 3 Printed i n USA 2/06 © 2006
1. When in the Time Mode, press and hold both theDOWN ARROW and the UP ARROW for 5 seconds to change the controller to the Tempera­ture Mode. The display will change to show the actual temperature for the currently selected heater.
Page 4
2. Press either the UP ARROW or the DOWN AR- ROW to select the proper heater assembly.
3. Press either the ACTUAL TEMP or SET POINT BUTTON to display the desired temperature.
4. Press and hold both the UP ARROW and DOWN ARROW for 5 seconds to return to the Time Mode.
PAN TIMER #4
1. Press and hold Pan Timer Button #4 and then the DOWN ARROW for approximately 6 seconds. The program LED will light up and the display will show the current countdown time for the channel.
2. Press either the UP ARROW or DOWN ARROW to adjust the time.
PROGRAMMING TIME CHANGE
To Program A Pan Timer Change:
NOTE: To program pan timer changes, the controller must be in the Timer Mode. If the controller is in the Temperature Mode, press and hold the UP ARROW and DOWN ARROW for 5 seconds. (Times can be programmed From “0” to 9:59 Hours.)
PAN TIMER #1
1. Press and hold Pan Timer Button #1 and then the UP ARROW for approximately 6 seconds. The program LED will light up and the display will show the current countdown time for the chan­nel.2. Press either the UP ARROW or DOWN ARROW to adjust the time.
2. When the correct time is displayed, press Pan Timer Button #1 to store the new time and return to the timer mode.
PAN TIMER #2
1. Press and hold Pan Timer Button #2 and then the DOWN ARROW for approximately 6 seconds. The program LED will light up and the display will show the current countdown time for the channel.
2. Press either the UP ARROW or DOWN ARROW to adjust the time.
3 When the correct time is displayed, press Pan
Timer Button #2 to store the new time and return to the timer mode.
PAN TIMER #3
1. Press and hold Pan Timer Button #3 and then the UP ARROW for approximately 6 seconds. The program LED will light up and the display will show the current countdown time for the channel.
2. Press either the UP ARROW or DOWN ARROW to adjust the time.
3. When the correct time is displayed, press Pan Timer Button #4 to store the new time and return to the timer mode.
Calibration Mode
The calibration mode offers a method to compensate between what temperature the controller senses and the temperature that a independant surface probe reads. Calibration should be done on a monthly basis.
Note: Allow the heaters sufficient time to tempera­ture stabilize before starting the Calibration Mode. The controller must be in the Temperature Mode to do heater calibrations.
1. Press the UP ARROW or the DOWN ARROW to select the heater assembly to be calibrated.
2. Take a surface temperature reading near the center of the heater assembly. CAUTION: The surface temperatures are HOT, caution must be used when taking temperature readings.
3. Press and hold the ACTUAL TEMP Button and the UP ARROW for 6 seconds. The program mode LED will light up and the actual temperature sensed by the conroller will appear in the display.
4. Press the UP ARROW or DOWN ARROW to adjust the display temperature until it matches the surface probe temperature.
5. Press the ACTUAL TEMP Button to store the calibrated temperature and return to the Tempera­ture Mode.
NOTE: To clear the offset value for a heater, press the SET POINT Button while in the calibration mode.The action will reset the offset value back to zero.
3. When the correct time is displayed, press Pan Timer Button #3 to store the new time and return to the timer mode.
4 54 2-5 13r evBPrinted i n USA 2/06 © 2006
Page 5
TROUBLESHOOTING
The controller incorporates some diagnostic hardware and software to aid in troubleshooting problems. The display will flash the problem if detected when the heater in question is selected.
Problem Cause Solution
A. Display flashes Open relay. Replace Power Circuit Board “Opn” & “rEL” Circuit inoperable
B. Display flashes Shorted relay. Replace Power Circuit Board. “SHr” & “rEL” Circuit inoperable.
Open heater. Test heater resistance.150.2 OHMS. Unplugged ribbon cable between Verify ribbon cable connection. Power and Main Circuit Boards.
C. Display shows “LLL” Temperature is below 75° F N/A
(normal operation)
Display shows “LLL” Heater inoperable. Test heater resistance.150.2 OHMS. for an extended period Probe inoperable. Check for open thermocouple wires from of time. probe. Replace heater/probe assembly.
Display shows “LLL” and Circuit inoperable. (see A). See A above. then changes to “Opn”& “rel” and heater surface temperature is cool.
Display shows “LLL” and Circuit inoperable. (see B) See B above. then changes to “SHr”&“rEL” and heater surface temperature is cool.
D.Display shows “HHH” for Temperature is above400° F Diagnostic circuit inoperable. Replace an extended period of time (abnormal operation) Power Circuit Board.See B above. and heater surface
temperature is hot.
Display shows “HHH” for Probe is inoperable Check for pinched thermocouple
an extended period of time wires from probe. Replace heater/probe and heater surface assembly. temperature is cool.
CLEANING
1) Turn off power switch.
CAUTION: This appliance is not water tight. Do not clean with a Water Jet/ Jet Spray. Do not immerse in water.
2) Unplug power cord from receptacle.
3) Allow heaters to cool (approximately 15 minutes).
4) Wipe down with a damp cloth. DO NOT USE AN ABRASIVE PAD, UNAPPROVED CLEANING SOLU­TIONS, ICE OR WATER.
54 2-5 13r evB 5 Printed in USA 2/06 © 2006
Unplug power cord before cleaning
Page 6
EXPLODED VIEW
6 542 -51 3re vBPrinted in USA 2/06 © 200 6
23
1
7
6
7
6
2
24
20
21
5
8
4
9
10
22
4
3
11
12
PARTS LIST
1 542-112 Cover, Side 2 76-719 Pin, Heater 3 542-114 Retainer, Shelf 4 542-113 Bracket, Shelf 5 542-108 Chassis, Left 6 542-131S Lower Heater Assembly (220-240 Volt) 7 542-130S Upper Heater Assembly (220-240 Volt) 8 542-072 Base 9 542-073 Cover, Bottom 10 197-232 Rubber Foot 11 78-166S Power Switch 12 542-020S Overlay with Bracket (542-082) 13 88-653S Speaker Assembly 14 542-010S Display P.C. Board 15 542-085 Wire Tunnel 16 542-119S Main P.C.Board (220-240V) 17 72-337S Power Cord (220-240 Volt) 18 542-106 Chassis, Right 19 542-078 Panel, Outer Rear 20 542-077 Panel, Inner Rear 21 542-118 Bracket, Rear Shelf 22 542-074 Header 23 542-075 Cover, Top 24 542-097 Trim, Top Heater
19
18
4
15
15
14
17
2
16
1
Page 7
WIRING DIAGRAM