This document is a translation of the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for internal purposes.
Suggestions and comments for improving this documentation will be gratefully received.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®,
SafetyNET p®, the spirit of safety® are registered and protected trademarks of
Pilz GmbH & Co. KG in some countries.
SD means Secure Digital.
Preface
Contents
Contents
ContentsPage
Chapter 1 Introduction
1.1Validity of the documentation1-1
1.1.1Retaining the documentation1-1
1.2Overview of documentation1-2
1.3Definition of symbols1-3
Chapter 2 Overview
2.1Unit structure2-1
2.1.1Scope of supply2-1
2.1.2Unit features2-1
2.2Front view2-2
Chapter 3 Safety
3.1Intended use3-1
3.1.1System requirements3-1
3.2Safety regulations3-2
3.2.1Use of qualified personnel3-2
3.2.2Warranty and liability3-2
3.2.3Disposal3-2
3.2.4For your safety3-3
Chapter 4 Function description
4.1Unit description4-1
4.1.1Operation4-1
4.1.2Input and output data4-1
4.1.3Assigning the inputs/outputs in the PNOZmulti Configurator to the EtherCAT inputs/
outputs
4.1.4Block diagram4-2
Chapter 5 Installation
5.1General installation guidelines5-1
5.1.1Dimensions5-1
5.2Connecting the base unit and expansion
modules
4-2
5-2
Chapter 6 Commissioning
6.1General wiring guidelines6-1
6.2Interface assignment6-2
6.3Preparing for operation6-3
6.3.1Download modified project to the PNOZmulti safety system
1.3Definition of symbols1300Definition of symbols1-Einfhrung Zeichen
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation
that poses an immediate threat of serious injury and death and
indicates preventive measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation
that could lead to serious injury and death and indicates preventive measures that can be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor
injury plus material damage, and also provides information on
preventive measures that can be taken.
NOTICE
This describes a situation in which the unit(s) could be damaged
and also provides information on preventive measures that can
be taken. It also highlights areas within the text that are of particular importance.
INFORMATION
This gives advice on applications and provides information on
special features.
Scope of supply2-Lieferumfang_Brck_774639_modul_BA
2.1.2Unit features
Unit features2-Gerätemerkmale_Verwendung
Expansion modulePNOZ mc2.1p
Jumper 774 639
Verwendung/Bildunterschrift_multi_Modul
Geraetemerkmale_Zusatz BA Einleitung
Gertemerkmale_Feldbus_EtherCAT_neu
Gertemerkmale
Gertemerkmale_Feldbusmodule allg
Gerätemerkmal_multi_Modul_Anschluss_Basis
Using the product PNOZ mc2.1p:
Expansion module for connection to a base unit from the configurable
control system PNOZmulti
The product has the following features:
Can be configured in the PNOZmulti Configurator
Network protocols: EtherCAT
supports CANopen over EtherCAT (DS301 V4.02-compliant)
Status indicators for communication with EtherCAT and for errors
The data length and the content of the PDOs can be freely configured
from EtherCAT-Master (max. 148 Bytes TxPDO and 20 Bytes RxPDO). The data are described in the document entitled "Communication Interfaces".
24 virtual outputs on the control system PNOZmulti can be defined in
the PNOZmulti Configurator for communication with the fieldbus
EtherCAT. The number of inputs and outputs can be extended to
128. Please note that when the extended inputs and outputs 24 - 127
are used they have different properties (see document entitled "Communication Interfaces").
Max. 1 PNOZ mc2.1p can be connected to the base unit
Please refer to the document "PNOZmulti System Expansion" for the