This document is a translation of the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for internal purposes. Suggestions and comments for improving this documentation will be
gratefully received.
Source code from third-party manufacturers or open source software has been used for
some components. The relevant licence information is available on the Internet on the Pilz
homepage.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries.
SD means Secure Digital
Page 3
Contents
Section 1Introduction4
1.1Validity of documentation4
1.2Using the documentation4
1.3Definition of symbols4
Section 2Overview6
2.1Scope6
2.2Unit features6
2.3Front view6
Section 3Safety7
3.1Intended use7
3.2System requirements7
3.3Safety regulations7
3.3.1Use of qualified personnel7
3.3.2Warranty and liability7
3.3.3Disposal8
3.3.4For your safety8
Section 4Function description9
4.1Functions9
4.2Block diagram9
Section 5Installation10
5.1General installation guidelines10
5.2Dimensions in mm10
5.3Connect power supply to base unit and fieldbus module10
Section 6Commissioning11
6.1General wiring guidelines11
6.2Connection11
6.3Connection example12
Section 7Operation13
Section 8Technical details14
Section 9Order reference16
9.1Product16
9.2Accessories16
Operating Manual PNOZ mc0p
21249-EN-03
3
Page 4
Introduction
1Introduction
1.1Validity of documentation
This documentation is valid for the product PNOZ mc0p. It is valid until new documentation
is published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
1.2Using the documentation
This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future reference.
1.3Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
Operating Manual PNOZ mc0p
21249-EN-03
NOTICE
This describes a situation in which the product or devices could be damaged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular importance.
4
Page 5
Introduction
INFORMATION
This gives advice on applications and provides information on special features.
Operating Manual PNOZ mc0p
21249-EN-03
5
Page 6
Overview
2
2Overview
2.1Scope
}Expansion module PNOZ mc0p
}Jumper
2.2Unit features
Using the product PNOZ mc0p:
Power supply used to supply voltage to the fieldbus modules PNOZ mc5p or PNOZ mc5.1p
LWL.
The product has the following features:
}Interface to connect the base unit and a fieldbus module
}Galvanic isolation
}Max. 1 fieldbus module (PNOZ mc5p or PNOZ mc5.1p LWL) can be connected
}Supply voltage 24 V DC
}Status indicators
}Please refer to the document "PNOZmulti System Expansion" for the PNOZmulti base
units that can be connected.
2.3Front view
Operating Manual PNOZ mc0p
21249-EN-03
6
Page 7
Safety
3Safety
3.1Intended use
The expansion module may only be connected to a base unit from the PNOZmulti system
(please refer to the document "PNOZmulti System Expansion" for details of the base units
that can be connected).
The configurable small control systems PNOZmulti are used for the safety-related interruption of safety circuits and are designed for use in:
}E-STOP equipment
}Safety circuits in accordance with VDE0113 Part 1 and EN60204-1
The module may only be used to supply voltage to the following fieldbus modules:
}PNOZ mc5p INTERBUS
}PNOZ mc5.1p INTERBUS LWL
3.2System requirements
Please refer to the "Product Modifications PNOZmulti" document in the "Version overview"
section for details of which versions of the base unit and PNOZmulti Configurator can be
used for this product.
3.3Safety regulations
3.3.1Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.
A competent person is someone who, because of their training, experience and current professional activity, has the specialist knowledge required to test, assess and operate the
work equipment, devices, systems, plant and machinery in accordance with the general
standards and guidelines for safety technology.
It is the company’s responsibility only to employ personnel who:
}Are familiar with the basic regulations concerning health and safety / accident preven-
tion
}Have read and understood the information provided in this description under "Safety"
}And have a good knowledge of the generic and specialist standards applicable to the
specific application.
3.3.2Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended
}Damage can be attributed to not having followed the guidelines in the manual
}Operating personnel are not suitably qualified
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Operating Manual PNOZ mc0p
21249-EN-03
7
Page 8
Safety
3.3.3Disposal
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
3.3.4For your safety
The unit meets all the necessary conditions for safe operation. However, you should always
ensure that the following safety requirements are met:
}This operating manual only describes the basic functions of the unit. The expanded
functions are described in the PNOZmulti Configurator's online help. Only use these
functions once you have read and understood the documentations.
}Do not open the housing or make any unauthorised modifications.
}Please make sure you shut down the supply voltage when performing maintenance
work (e.g. exchanging contactors).
Operating Manual PNOZ mc0p
21249-EN-03
8
Page 9
Function description
Fieldbus module
Base module
4Function description
4.1Functions
The PNOZ mc0p power supply provides the fieldbus module with the necessary internal
supply voltage. This way the fieldbus module remains available even when the base unit is
switched off. The power supply is connected to the base unit and fieldbus module via jumpers. When the 24 VDC supply voltage is applied, the “POWER” LED is lit. The “BASE” LED
is lit when supply voltage is applied to the base unit.
4.2Block diagram
Operating Manual PNOZ mc0p
21249-EN-03
9
Page 10
Installation
94 (3.70")
22,5
(0.88")
114 (4.49")
5Installation
5.1General installation guidelines
}The control system should be installed in a control cabinet with a protection type of at
least IP54. Fit the control system to a horizontal mounting rail. The venting slots must
face upward and downward. Other mounting positions could destroy the control system.
}Use the notches on the rear of the unit to attach it to a mounting rail. Connect the con-
trol system to the mounting rail in an upright position, so that the earthing springs on the
control system are pressed on to the mounting rail.
}The ambient temperature of the PNOZmulti units in the control cabinet must not exceed
the figure stated in the technical details, otherwise air conditioning will be required.
}To comply with EMC requirements, the mounting rail must have a low impedance con-
nection to the control cabinet housing.
CAUTION!
Damage due to electrostatic discharge!
Electrostatic discharge can damage components. Ensure against discharge
before touching the product, e.g. by touching an earthed, conductive surface or by wearing an earthed armband.
5.2Dimensions in mm
5.3Connect power supply to base unit and fieldbus module
Connect the modules as described in the operating instructions for the base units.
}Install the power supply to the left between the base unit and fieldbus module.
Operating Manual PNOZ mc0p
21249-EN-03
10
Page 11
Commissioning
24V
+ 24 V DC
0 V
24V
0V
0V
X1/X2
24V
+ 24 V DC
0 V
24V
0V
0V
X1
24V
+ 24 V DC
0 V
24V
0V
0V
X2
6Commissioning
6.1General wiring guidelines
Please note:
}The PNOZ mc0p can be supplied by a separate power supply (see Connection
example [ 12]). The power supply must meet the regulations for extra low voltages
with protective separation (SELV, PELV).
}The torque setting of the screws on the connection terminals is specified under Tech-
nical details [ 14].
}Use copper wiring with a temperature stability of 75 °C.
}Information given in the Technical details [ 14] must be followed.
6.2Connection
Supply voltageACDC
Supply voltage from Interbus
master only:
Connect the supply voltage to X1
or X2.
The fieldbus connection is maintained if the base unit is switched
off.
When the Interbus master is restarted, the power supply to the
base unit must be reset.
Supply voltage from Interbus
master and base unit:
Example:
Connect the supply voltage from
the base unit to X1.
Connect the supply voltage from
the Interbus master to X2.
The fieldbus connection is maintained if the base unit is switched
off.
When the Interbus master is restarted, the fieldbus is available
immediately.
Operating Manual PNOZ mc0p
21249-EN-03
11
Page 12
Commissioning
I0I1I2I3I4I5I6I7I8I9I10
I11
I12
I13
I14
I15
I16
I17
I18
I19A1A1A2A2
CI+
CI-
CO-
CO+T0T1T2T3O0O1O2O3
OA0
24V
24V0V0V13142324
L+
L-
PNOZ mc0p
24V
24V0V0V
PNOZ m1p
PNOZ mc5.1p
L+
L-
24V
24V0V0V
6.3Connection example
Redundant power supply
Operating Manual PNOZ mc0p
21249-EN-03
12
Page 13
Operation
7Operation
The unit is ready for operation when the "POWER" LED is lit continuously.
Status indicators:
}"POWER" is lit: Supply voltage is applied to PNOZ mc0p.
}"BASE" is lit: Supply voltage applied to base unit.
Operating Manual PNOZ mc0p
21249-EN-03
13
Page 14
Technical details
8Technical details
General
ApprovalsCCC, CE, EAC (Eurasian), cULus Listed
Electrical data
Supply voltage
forModule supply
Voltage24,0 V
KindDC
Voltage tolerance-15 %/+20 %
Output of external power supply (DC)5,0 W
Residual ripple DC5 %
Potential isolationyes
Status indicatorLED
Times
Supply interruption before de-energisation20 ms
Environmental data
Ambient temperature
In accordance with the standardEN 60068-2-14
Temperature range0 - 55 °C
Storage temperature
In accordance with the standardEN 60068-2-1/-2
Temperature range-25 - 70 °C
Climatic suitability
In accordance with the standardEN 60068-2-30, EN 60068-2-78
Humidity93 % r. h. at 40 °C
Condensation during operationNot permitted
EMCEN 61131-2
Vibration
In accordance with the standardEN 60068-2-6
Frequency10,0 - 150,0 Hz
Acceleration1g
Shock stress
In accordance with the standardEN 60068-2-27
Acceleration15g
Duration11 ms
Max. operating height above sea level2000 m
Airgap creepage
In accordance with the standardEN 61131-2
Overvoltage categoryIII
Pollution degree2
Rated insulation voltage30 V
Operating Manual PNOZ mc0p
21249-EN-03
14
Page 15
Technical details
Environmental data
Protection type
In accordance with the standardEN 60529
Mounting area (e.g. control cabinet)IP54
HousingIP20
TerminalsIP20
Potential isolation
Potential isolation betweenModule and system voltage
Spring-loaded terminals: Terminal points per connection1
Stripping length with spring-loaded terminals9 mm
Dimensions
Height94,0 mm
Width22,5 mm
Depth121,0 mm
Weight125 g
Where standards are undated, the 2007-05 latest editions shall apply.
Operating Manual PNOZ mc0p
21249-EN-03
15
Page 16
Order reference
9Order reference
9.1Product
Product typeFeaturesOrder No.
PNOZ mc0pExpansion module, power supply for fieldbus modules773 720
9.2Accessories
Jumper
Product typeFeaturesOrder No.
KOP-XEJumper774 639
Connection terminals
Product typeFeaturesOrder No.
Set spring terminals1 set of spring-loaded terminals783 400
Set screw terminals1 set of screw terminals793 400
Operating Manual PNOZ mc0p
21249-EN-03
16
Page 17
The Best of
German
En
gineering
Partner of:
Support
Technical support is available from Pilz round the clock.
Americas
Brazil
+55 11 97569-2804
Canada
+1 888-315-PILZ (315-7459)
Mexico
+52 55 5572 1300
USA (toll-free)
+1 877-PILZUSA (745-9872)
Asia
China
+86 21 60880878-216
Japan
+81 45 471-2281
South Korea
+82 31 450 0680
Australia
+61 3 95446300
Europe
Austria
+43 1 7986263-0
Belgium, Luxembourg
+32 9 3217575
France
+33 3 88104000
Germany
+49 711 3409-444
Ireland
+353 21 4804983
Italy
+39 0362 1826711
Scandinavia
+45 74436332
Spain
+34 938497433
Switzerland
+41 62 88979-30
The Netherlands
+31 347 320477
Turkey
+90 216 5775552
United Kingdom
+44 1536 462203
You can reach our
international hotline on:
+49 711 3409-444
support@pilz.com
CMSE
®
, InduraNET p
®
, PAS4000
®
, PAScal
®
, PASconfig
®
, Pilz
®
, PIT
®
, PLID
®
, PMCprimo
®
, PMCprotego
®
, PMCtendo
®
, PMD
®
, PMI
®
, PNOZ
®
, Primo
®
, PSEN
®
, PSS
®
, PVIS
®
, SafetyBUS p
®
,
SafetyEYE
®
, SafetyNET p
®
, THE SPIRIT OF SAFETY
®
are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary
from the details stated in this document, depending on the status at the time of publication and the scope of the equipment. We accept no responsibility for the validity, accuracy
and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions.
Pilz develops environmentally-friendly products using
ecological materials and energy-saving technologies.
Oces and production facilities are ecologically designed,
environmentally-aware and energy-saving. So Pilz oers
sustainability, plus the security of using energy-ecient