Pilz PNOZ 3 Data Sheet

Emergency Stop Relays, Safety Gate Monitors
Category 3, EN 954-1
PNOZ 3
Technical Details PNOZ 3
Electrical Data
Emergency stop relay and safety gate monitor in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98.
Features
Single-channel or dual-channel without the detection of shorts across the input contacts
1 N/O auxiliary contact is a fleeting contact
Approvals
Supply Voltage AC:
Tolerance 85 ... 110 % Power Consumption Approx. 4.5 W/9 VA Voltage and Current at the Input and 24 VDC, 50 mA Reset Circuits and Feedback Control Loop Switching Capability in accordance with EN 60947-4-1, 01/00 AC1: 240 V/8 A/2000 VA,
EN 60947-5-1, 08/00 (DC13: 6 cycles/min.) Output Contacts 5 safety contacts (N/O)
Contact Fuse Protection 10 A quick or 6 A slow EN 60947-5-1, 08/00
Times
Delay-on Energisation Approx. 250 ms Delay-on De-energisation Max. 50 ms Fleeting Contact 73-74 Approx. 150 ms Simultaneity channel1/2 Approx. 150 ms or ¥
Max. Supply Interruption before De-energisation Approx. 10 ms
Mechanical Data
Torque Setting on Connection Terminals 1.2 Nm (screws) Max. Cross Section of 2 x 2.5 mm External Conductors Single-core or multi-core
Dimensions (H x W x D) 75 x 135 x 111.5 mm Weight 830 g
24, 42, 48, 110, 115, 120, 230, 240 V
DC: 24 V
400 V/5 A/2000VA DC1: 24 V/8 A/200 W AC15: 230 V/5 A; DC13: 24 V/7 A
1 auxiliary contact (N/C) 1 fleeting auxiliary contact (N/O)
with crimp connectors
1
2
PNOZ 3
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-066-06/01 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Description
135 mm, P-75 housing, DIN Rail mounting
Positive-guided relay outputs: – 5 safety contacts (N/O) – 1 auxiliary contact (N/C) – 1 fleeting auxiliary contact (N/O)
Connections for – E-STOP button – safety gate limit switch – reset button
LEDs for channel 1/2 and power
Increase in the number of safety contacts available by connecting expander modules.
Operating Modes
Single-channel operation
Dual-channel operation
Automatic reset
Manual reset
1-1
Emergency Stop Relays, Safety Gate Monitors
Category 3, EN 954-1
PNOZ 3
1
Internal Wiring Diagram
UBInput circuit Feedback
A2
A1
(L-) T11 T12 T12 T22 X1 X2
(L+)
F1
~
+
G1
=
K1.1 K3 .1 K 2.1 K3.2
K2 K3
K1
T33 T34
Reset circuit
External Wiring
Example 1 Single-channel E-STOP wiring with manual reset.
T11 T12 T33
S1
X1
S3
control loop
K1.2
K2.2
Simul­taneity
X3 X4
Safety contacts
13 23 33 73
K1
K2
K3
14 24 34 74
43 53
44
54
Auxiliary contacts
61
62
Example 4
Time difference extended to infinity on a safety gate control with manual reset.
T33 X1
T12
T11
S3
Increase in safety contacts The number of output contacts can be increased by using expander modules or relays/contactors with positive-guided contacts.
1L1
K5
K4
X1 X2
1L2
X4
62
X3
13
14
K4 K5
T34T22
T12
X2
Example 2 Dual-channel E-STOP wiring with manual reset.
T11 T33
S1
T12
X1
S3
T34T22
X2
Example 3 Single-channel safety gate control with automatic reset while simultaneity is maintained.
T12 X1
T33
S1
T11
S2
61
X2
T22
T34
73
74
– Key
S1/2: E-STOP or safety gate switch
S3: Reset button
Switch operated
Gate open
Gate closed
X2T22
T34
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-066-06/01 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de