Philips NE83Q93N, NE83Q93D Datasheet

INTEGRATED CIRCUITS
NE83Q93
Enhanced coaxial Ethernet transceiver
Product specification IC19 Data Handbook
 
1995 May 01
NE83Q93Enhanced coaxial Ethernet transceiver

DESCRIPTION

The NE83Q93 is a low power coaxial transceiver interface (CTI) for Ethernet (10base5) and Thin Ethernet (10base2) local area networks. The CTI is connected between the coaxial cable and the Data Terminal Equipment (DTE) and consists of a receiver, transmitter, receive-mode collision detector, heartbeat generator and jabber timer (see Block Diagram). The transmitter output connects directly to a doubly terminated 50 cable, while the receiver output, collision detector output and transmitter input are connected to the DTE through isolation transformers. Isolation between the CTI and the DTE is an IEEE 802.3 requirement that can be met on signal lines by using a set of pulse transformers. Power isolation for the CTI is achieved using DC-to-DC conversion through a power transformer (see Figure 3, Connection Diagram).
The part is functionally the same as the NE83Q92, but with additional features such as a transmit enable input, a carrier detect output and five status LED driver outputs.
The NE83Q93 is manufactured on an advanced BiCMOS process and is available in an SOL package making it ideally suited to lap-top personal computers or systems where low power consumption, limited board space and jumperless design is required. Refer to selection flow chart for optimal application.

FEA TURES

Fully compliant with Ethernet II, IEEE 802.3 10BASE-5 and
10BASE-2, and ISO 8802/3 interface specifications
Functionally compatible with industry standard 8392 applications
Optimal implementation can use 1 Watt DC-DC converter and
reduces external parts count
High efficiency AUI drivers minimize current consumption under
idle conditions by automatically powering-down
Automatically disables AUI drivers when disconnecting coax
cable, allowing hard-wiring of AUI connector and local/integrated CTI connection
PIN CONFIGURATION
D, N Packages
1
CD+ CD– RX+
V
EE
V
EE
RX– TX+
TX–
TEN
XLED
JLED
LCOM
2 3 4 5 6 7 8
9 10 11 12
CDS
24 23
TXO RXI
22 21
V
20
RR– RR+
19
GND
18
HBE
17 16
CRS
15
RLED
14
LINK
13
CLED
SD00311
EE
Figure 1. Pin Configurations
Smart squelch on data inputs eliminates false activations
Transmit enable input and carrier sense output for repeater
applications
Five LED status drivers for transmit, receive, collision, jabber and
link fail indication
Advanced BiCMOS process for extremely low power operation
Available in 24-pin DIP and 24-pin SOL packages
Full ESD protection
Power-on reset prevents glitches on coaxial cable

ORDERING INFORMATION

DESCRIPTION TEMPERATURE RANGE ORDER CODE DWG #
24-Pin Plastic Dual In-Line Package (DIP) 24-Pin Plastic Small Outline Large (SOL) Package
1995 May 01 853-1738 15180
2
0 to +70°C 0 to +70°C
NE83Q93N SOT222–1 NE83Q93D SOT137-1
Philips Semiconductors Product specification
NE83Q93Enhanced coaxial Ethernet transceiver

PIN DESCRIPTIONS

PIN NO.
D, N PKG
1 2
3 6
7 8
9 TEN
10 XLED Transmit Indicator. Indicates a packet is being transmitted onto the coaxial cable. 11 JLED Jabber Indicator. Indicates that the jabber timer has timed out and the coaxial driver is disabled. 12 LCOM LED Common. The anodes of all status indicator LEDs are connected to this pin. It’s voltage is VEE + 5V. 13 CLED Collision Indicator . Indicates that a collision has been detected. 14 LINK Link Indicator. Indicates that a connection is present to the coaxial cable network. 15 RLED Receive Indicator . Indicates that a packet is being received from the coaxial cable.
16 CRS
17 HBE 11
12 22 RXI
23 TXO
24 CDS 18 GND Positive Supply Pin.
4 5
21
SYMBOL DESCRIPTION
CD+ CD–
RX+ RX–
TX+ TX–
RR+ RR–
V
Collision Outputs. Balanced differential line driver outputs which send a 10MHz signal to the DTE in the event of a collision, jabber interrupt or heartbeat test. External pull-down resistors are optional.
Receiver Outputs. Balanced differential line driver outputs which send the received signal to the DTE. External pull-down resistors are optional.
Transmitter Inputs. Balanced differential line receiver inputs which accept the transmission signal from the DTE and apply it to the coaxial cable at TXO, if it meets Tx squelch threshold.
Transmit Enable. A CMOS compatible input requiring an input voltage range of VEE to VEE + 5V. The transmitter and loopback functions are disabled when TEN is LOW and enabled when TEN is HIGH or left floating. TEN is normally driven through an opto-coupler.
Carrier Sense. A real time output that indicates the presence of a carrier on the coaxial cable. CRS is normally used to drive an opto-coupler.
Heartbeat Enable. The heartbeat function is disabled when this pin is connected to VEE and enabled when connected to GND or left floating.
External Resistor. A 1k (1%) resistor connected between these pins establishes the signaling current at TXO. Receiver Input. This pin is connected directly to the coaxial cable. Received signals are equalized, amplified,
and sent to the DTE through the RX± pins, if it meets Rx squelch threshold. Transmitter Output. This pin is connected directly (Thin Ethernet) or through an external isolating diode
(Ethernet) to the coaxial cable. Collision Detect Sense. Ground sense connection for the collision detection circuitry. This pin should be
connected directly to the coaxial cable shield for standard Ethernet operation.
Negative supply pins.
EE
NOTE:
1. The IEEE 802.3 name for CD is CI; for RX is DI; for TX is DO.
1995 May 01
3
Philips Semiconductors Product specification
NE83Q93Enhanced coaxial Ethernet transceiver

BLOCK DIAGRAM

COAX
CABLE
DTE
INTERFACE
RXI
TXO
CDS
TEN
HBE
BUFFER
RECEIVER
EQUALIZER
4–POLE BESSEL
LOW PASS FILTER
SENSE BUFFER
TRANSMITTER
TRANSMITTER
SQUELCH
COLLISION
COMPARATOR
& HEARTBEAT GENERATOR
JABBER
TIMER
RECEIVER
SQUELCH
LINE
DRIVER
10MHz
OSC
STATUS
CONTROL
DRIVER
LINE
RECEIVE
PAIR
(RX+, RX–)
CARRIER
SENSE
(CRS)
TRANSMIT
PAIR
(TX+, TX–)
LINK COLLISION
(CLED) JABBER (JLED)
XLED RLED
LCOM
COLLISION
PAIR
(CD+, CD–)
SD00312
Figure 2. Block Diagram

ABSOLUTE MAXIMUM RATINGS

SYMBOL PARAMETER RATING UNIT
V
EE
V
IN
T
STG
T
SOLD
T
J
θ
JA
NOTE:
1. 100% measured in production.
Supply voltage Voltage at any input
Storage temperature range –65 to +150 Lead soldering temperature (10sec.) +300 Recommended max junction temperature Thermal impedance (N and A packages) 60
2. The junction temperature is calculated from the following expression: TJ = TA + θ
where
[(VEE x 0.015 x n
JA
TA = Ambient temperature in °C.
θJA = Thermal resistance of package.
V
= Normal operating supply voltage in volts.
EE
= Percentage of duty cycle idle
n
IDL
n
= Percentage of duty cycle receiving
RX
n
= Percentage of duty cycle transmitting
TX
1
1
2
) + (VEE x 0.027 x nRX) + (VEE x 0.075 x nTX)]
IDL
–12 V
0 to –12 V
+150
°C °C °C
°C/W
1995 May 01
4
Philips Semiconductors Product specification
NE83Q93Enhanced coaxial Ethernet transceiver

ELECTRICAL CHARACTERISTICS

4
MAX
CD
1,2
. No external isolation.
Without external
pull-down resistors and
no LED loads
Measured by applying
DC voltage at RXI
(CDS = 0V)
Measured as DC
voltage at RXI
V
RXI
(CDS = 0V)
TX+
OUT
and V
are the max and min voltages at TXO with a 25 load between TXO and
MIN
.
LIMITS
–7.5 V
–80 –90 mA
= 0V –2 +25 µA
RXI
= 0V +1 +3 µA
CDS
+2.4 V
EE
+1.6 V
EE
= 0V +10 µA
HBE
HBE
= V
EE
–30 µA
–37 –45 mA ±28 ±I
= –10V –250 +250 µA
TXO
TDC
–3.7 V
–1450 –1530 –1580 mV
–3.5 V
±600 ±1100 mV
±40 mV
average DC
– V
) peak –175 –225 –275 mV
TX–
–150 –250 –350 mV
1 2 pF
6 k
= 8mA V
< VEE + 5 10 µA
OUT
+1.4 V
EE
mA
VEE = –9V ±6%; TA = 0°C to +70°C unless otherwise specified
SYMBOL PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
UVL
Under voltage lockout. Transceiver disabled for |VEE| < |V
UVL
|
Supply current idle –15 –20 mA
I
I
I
V
V
TENH
V
I
TENL
I
I
I
TX10
V
TCOM
V
V
V
V V V
V R C
R
R
R
EE
RXI
CDS
IH
V
IL
I
IH
I
IL
TENL
TDC TAC
CD
DIS
OD
OB
OC
RS
TS RXI RXI
TXO
AUIZ
TX
Supply current transmitting (without collision)
Receive input bias current V Cable sense input bias current V HBE input HIGH voltage V HBE input LOW voltage V HBE input HIGH current V HBE input LOW current V Input HIGH voltage at TEN VEE + 2 V Input LOW voltage at TEN VEE + 1 V Input LOW current at TEN –50 –100 µA Transmit output DC current level Transmit output AC current level
3 3
Transmit current V Transmitter output voltage compliance
Collision threshold
5
AUI disable voltage at RXI Differential output voltage – non idle at RX± and
6
CD± Differential output voltage imbalance – idle at
RX± and CD±
7
Output common mode voltage at RX± and CD± RXI = 0V –4.0 –5.5 –7.0 V Receiver squelch threshold Transmitter squelch threshold (V
Shunt resistance at RXI non–transmitting 100 k Input capacitance at RXI
8
Shunt resistance at TXO transmitting 7.5 10 k Differential impedance at RX± and CD± with no
coaxial cable connected Differential impedance at TX± 20 k
LED driver and CRS output
V
OL
I
OL
Output LOW voltage I Output leakage current inactive VEE < V
NOTES:
1. Currents flowing into device pins are positive. All voltages are referenced to ground unless otherwise specified. For ease of interpretation, the parameter limit that appears in the MAX column is the largest value of the parameter, irrespective of sign. Similarly, the value in the MIN column is the smallest value of the parameter, irrespective of sign.
2. All typicals are for V
3. I
is measured as (V
TDC
GND. I
4. The TXO pin shall continue to sink at least I
is measured as (V
TAC
5. Collision threshold for an AC signal is within 5% of V
= –9V and TA = 27°C.
EE
+ V
MAX
)/(2 x 25) where V
MIN
– V
MAX
)/(2 x 25).
MIN
min when the idle (no signal) voltage on this pin is –3.7V .
TDC
6. Measured on secondary side of isolation transformer (see Connection Diagram, Figure 3). The transformer has a 1:1 turns ratio with an inductance between 30 and 100µH at 5MHz.
7. Measured as the voltage difference between the RX pins or the CD pins with the transformer removed.
8. Not 100% tested in production.
1995 May 01
5
Loading...
+ 11 hidden pages