INSTRUCTION
MANUAL
LED Display・Digital Pressure Sensor
DP2 Series
For use outside Japan
Thank you very much for purchasing Panasinic products.
Read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
MJE-DP2 No.0048-50V
WARNING
Never use this product as a sensing device for personnel protection.
●
In case of using sensing devices for personnel protection, use products which meet laws and standards, such as
●
OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
In case this sensor is used within Japan, SI unit must be used since use of pressure units in Japan is restricted to SI units.
●
1
SPECIFICATIONS
Vacuum pressure
Type
Asian
North American (Note)
Model No.
European
Item
Type of pressure
Rated pressure range
Set pressure range -0.050 to 1.000MPa-5.0 to 100.0kPa5.1 to -101.3kPa
Pressure withstandability
Applicable fluid Non-corrosive gas
Selectable units kgf/cm2, bar, psikgf/cm2, bar, psi, mmHg, inHg
Supply voltage
Current consumption
Comparative outputs
Comparative Output 1
Comparative Output 2
Output modes
Short-circuit protection
Analog voltage
output
Displayable pressure range
Comparative Output 1
Operation
indicators
Comparative Output 2
Ambient temperature
Overvoltage category
Temperature characteristics
Asian Standard ・ Flat ・ IP67 types: Rc (PT)
Pressure
North American
port
European Flat ・ IP67 types: G (PF)
Material
Note:
Model Nos. of North American standard type having the suffix '-P' are PNP output type.
2
CAUTIONS
Standard Flat
DP2-20
DP2-20F(-P)
-
Asian
North American (Standard NPN output, Flat, IP67 types)
NPN open-collector transistor
・Maximum sink current: 100mA
Applied voltage: 30V DC or less (between comparative output and 0V)
・
・Residual voltage: 1V or less (at 100mA sink current)
Equipped with 4 types of modes: hysteresis mode, window comparator mode, dual output mode, automatic sensitivity
setting mode (selectable by key operation)
Front case: ABS, Rear case: PPS (glass fiber reinforced), Display surface: Acrylic
Pressure port attachment: Die-cast zinc alloy [Light weight type: POM (glass fiber reinforced), pressure port is brass (nickel plated)]
Front cover (IP67 type only): Polycarbonate
Standard type: 95g approx., Flat type: 120g approx., IP67 type: 370g approx., Light weight type: 70g approx.Weight
DP2 series is designed for use with non-corrosive gas.
It cannot be used for liquid or corrosive gas.
T
his product has been developed / produced for
●
industrial use only.
●
Use within the rated pressure range.
Do not apply pressure exceeding the pressure
●
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
Make sure to carry out the wiring in the power supply
●
off condition.
●
Take care that wrong wiring will damage the sensor.
●
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching
●
regulator, ensure that the frame ground (F.G.) terminal
of the power supply is connected to an actual ground.
●
In case noise generating equipment (switching
regulator, inverter motor, etc.) is used in the vicinity of
this sensor, connect the frame ground (F.G.) terminal
of the equipment to an actual ground
-101kPa type
-
DP2-40N DP2-60N
DP2-40E DP2-60E
0.4V or less (at 16mA sink current)
1 digit (However, variable in hysteresis mode and 2 digits when using psi unit)Hysteresis
Output voltage: 1 to 5V (over rated pressure range)
Zero-point: within 1V ±5% F.S.
Span: within 4V ±5% F.S.
Linearity: within ±1% F.S.
Output impedance: 1kΩ approx.
Standard ・ Flat ・ Light weight types: IP40 (IEC), IP67 type: IP67 (IEC)Protection
-10 to +50℃ (No dew condensation or icing allowed), Storage: -10 to +60℃
Over ambient temperature range -10 to +50℃: within ±1% F.S. of detected pressure at 20℃
Standard type: NPTF 1/8female thread, Flat ・ IP67 types: NPT 1/8 female thread
0.15mm2 5-core oil resistant cabtyre cable, 2m long (IP67 type: 5m long)Cable
Hexagon-socket-head plug for pressure port: 1 No. (Standard type only), Pressure unit label: 1 No.Accessories
Light weight
IP67 Standard StandardFlat IP67 Flat IP67
DP2-60 DP2-80 DP2-21 DP2-41 DP2-61 DP2-22 DP2-42 DP2-62
3
-
DP2-21F(-P)
- -
12 to 24V DC % Ripple P-P 10% or less
Within ±0.2% F.S. ±1 digitRepeatability
1
/2 digit red LED display (Sampling rate: 4 times/sec. approx.)Display
LED bar display in steps of 10% F.S. approx.Analog bar display
Orange LED (lights up when Comparative Output 1 is ON)
Green LED (lights up when Comparative Output 2 is ON)
35 to 85% RH, Storage: 35 to 85% RHAmbient humidity
DP2-41N DP2-61N
DP2-41E DP2-61E
Gauge pressure
+10
-15
50mA or less
2.5ms or lessResponse time
Incorporated
Output voltage (V)
2Pollution degree
II
2,000m or lessUsable altitude
1
/8 female thread, Light weight type: M5 female thread
Do not use during the initial transient time (0.5 sec.)
●
after the power supply is switched on.
Do not run the wires together with high-voltage lines or
●
power lines or put them in the same raceway. This can
cause malfunction due to induction.
●
This product is suitable for indoor use only.
Avoid use of standard type, flat type and light weight type
●
of sensor in places where steam and dust is excessive.
Take care that the sensor does not come in contact
●
with water, oil, grease, or organic solvents, such as,
thinner, etc.
Do not insert wires, etc, into the pressure port. The
●
diaphragm will get damaged and correct operation
shall not be maintained.
●
Do not operate the keys with pointed or sharp objects.
●
Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
●
Extension up to total 100m is possible with 0.3mm
more, cable. However, in case of using this product as
a CE Marking conformity product, the power wire
connected to this product must be within 10m.
Positive pressure
DP2-22F(-P)
<
North American (Standard PNP output type), European
PNP open-collector transistor
・Maximum source current: 100mA
・Applied voltage: 30V DC or less
・
Residual voltage: 2V or less (at 100mA source current)
5
1
Pressure
1
/8 female thread
(between comparative output and +V)
1MPa type100kPa type
DP2-42N DP2-62N
-
DP2-42E DP2-62E
0 to 1.000MPa0 to 100.0kPa0 to -101.3kPa
1.47MPa490kPa
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
-0.050 to 1.000MPa-5.0 to 100.0kPa5.1 to -101.3kPa
2
>
, or
3
SETTING OF PRESSURE LEAD
DIRECTION AND PIPING
Standard type
●
Setting of pressure lead direction
・
The pressure lead
direction can be changed
by dismantling the
pressure port attachment
and changing the
mounting direction. The
tightening torque of the
hexagon-socket-head
bolt (length 9mm or less)
should be 0.29N・m or
less.
Please make sure to close any unused pressure port with
Note:
Pressure port
attachment
Hexagon-sockethead plug
the hexagon-socket-head plug supplied as accessory.
●
Piping
・
When connecting a
hexagon-socket-head plug
or coupling to the pressure
port, hold the hexagonal
part of the pressure port
with a 12mm spanner and
make sure that the
tightening torque is 9.8N・m or less. Also, in order to
prevent any leakage, wind a sealing tape on the
coupling when connecting.
However, sealing tape is not required for North
American type using NPTF
is required if NPT
1
/8 coupling is used.)
Flat type, Light weight type
●
Setting of pressure lead direction
・
The pressure lead direction can be changed by dismantling
the pressure port attachment and changing the mounting
direction. The tightening torque of the hexagon-socket-head
bolt (length 9mm or less) should be 0.29N・m or less.
Pressure port attachment
Main body
Pressure port
●
Piping
・
When connecting a coupling
to the pressure port, hold the
pressure port attachment
with a 16mm (Light weight
type: 10mm) spanner and
make sure that the tightening
torque is 9.8N・m or less
(Light weight type: 1.47N・m
or less). Also, in order to prevent any leakage, wind a
sealing tape on the coupling when connecting.
IP67 type
●
Piping for pressure measurement inlet port
・
When connecting a coupling to the pressure measurement
inlet port, hold the pressure port attachment with a spanner
and make sure that the tightening torque is 9.8N・m or less.
Also, in order to prevent any leakage, wind a sealing
tape on the coupling when connecting.
●
Piping for atmospheric pressure inlet port
・
If there is a possibility of
water entering into the
sensor enclosure through
the atmospheric pressure
inlet port, connect a tube
to the atmospheric
pressure inlet port through
a M5 coupling and extend
the other end of the tube
to a safe place. In this
case, ensure that this end
of the tube does not get
clogged.
●
Fitting of front cover
・
Insert the bosses on the front cover into the guide
holes at the bottom of the pressure port attachment,
and push in the
direction of the
Hook
arrow to fit the
hook.
When removing
the front cover,
release the hook
first.
Main body
Hexagonsockethead bolts
Pressure
ports
12mm spanner
1
/8 coupling. (Sealing tape
Hexagon-sockethead bolts
2-φ4.3mm mounting holes
16mm
(light weight type: 10mm)
spanner
Safe place,
where there is no
exposure to water
Atmospheric
pressure inlet port
M5 coupling
Tube
Pressure measurement
inlet port
Guide holes
DP2-20
-101.3kPa
OUT2OUT1
MODE
0-ADJ
4
MOUNTING OF STANDARD
TYPE SENSOR
●
A sensor mounting bracket MS-DPX and MS-DPX-4
(optional) may be used.
When mounting the sensor with the sensor mounting
bracket, etc., the tightening torque should be 1.2N・m
or less.
<MS-DPX>
<MS-DPX-4>
Sensor mounting
bracket
MS-DPX-4 (optional)
Note: In case mounting brackets or screws other than the
Note:
Note:
M4 (length 6mm) pan head screw
(attached with MS-DPX)
Spring washer
(attached with MS-DPX)
Sensor mounting bracket
MS-DPX (optional)
Spring washer
(attached with MS-DPX-4)
M4 (length 6mm) pan head screw
(attached with MS-DPX-4)
sensor mounting bracket shown in the figure above
are used, the length of the screws inserted into the
pressure port attachment should be 5mm or less. If
the length of the screws is longer than 5mm, the
sensor may be damaged.
●
Panel mounting bracket MS-DPX-2 (optional) and a front
protection cover DPX-04 (optional) are also available.
Front protection cover
DPX-04 (optional)
5
I/O CIRCUIT DIAGRAM
●
NPN output type
D
1kΩ
ZD1
Tr1
ZD2
Sensor circuit
ZD3
Tr2
DP2-20
–101.3kPa
OUT2OUT1
0-ADJ
MODE
Panel mounting bracket
MS-DPX-2 (optional)
(Suitable for 1 to 3.2mm thick panel)
Color code
(Brown) +V
(Gray) Analog
voltage output
(Note)
(Black) Comparative Output 1
(White) Comparative Output 2
(Blue) 0V
100mA max.
100mA max.
Load
Load
Users’ circuitInternal circuit
+
-
12 to 24V
+10
%
-15
The analog voltage output is not incorporated with a
short-circuit protection circuit. Do not directly connect
a power supply or a capacitive load. When using the
analog voltage output, take care to connect external
equipment of proper input impedance.
Also, when a cable extension is used, voltage drop
due to cable resistance should be taken into account.
Symbols...D: Reverse supply polarity protection diode
●
D1, ZD2, ZD3: Surge absorption zener diode
Z
r1, Tr2: NPN output transistor
T
PNP output type
Color code
D
Tr1
ZD1
Tr2
1kΩ
Sensor circuit
(Brown) +V
(Black) Comparative Output 1
ZD2
(White) Comparative Output 2
(Gray) Analog
voltage output (Note)
ZD3
(Blue) 0V
Users’ circuitInternal circuit
100mA max.
100mA max.
Load
Load
+
-
12 to 24V
+10
%
-15
The analog voltage output is not incorporated with a
short-circuit protection circuit. Do not directly connect
a power supply or a capacitive load. When using the
analog voltage output, take care to connect external
equipment of proper input impedance.
Also, when a cable extension is used, voltage drop
due to cable resistance should be taken into account.
Symbols...D: Reverse supply polarity protection diode
D1, ZD2, ZD3: Surge absorption zener diode
Z
r1, Tr2: PNP output transistor
T
6
FUNCTIONAL DESCRIPTION
①
DP2-20
-101.3kPa
②
OUT2OUT1
0-ADJ
MODE
④
⑤
Description Function
DC
DC
1
/2 digit LED
3
①
display (Red)
Comparative Output 1
②
operation indicator
(Orange)
Comparative Output 2
③
operation indicator
(Green)
Increment key
④
( )
Decrement key
⑤
( )
Mode selection key
⑥
MODE
( )
7
ERROR MESSAGES
When an error occurs, take the following corrective action.
●
Error message
8
ANALOG BAR DISPLAY
Pressure changes are displayed in an analog fashion by using LED bars.
●
Hence, any sudden changes in pressure can be detected at a glance.
The analog bar display shows the measured pressure,
●
irrespective of the pressure unit, in steps of 10% F.S. approx.
Please refer to ' SETTING ② Initial setting' for the
Displays measured pressure, settings,
error messages and key-protect status.
Lights up when Comparative Output 1 is ON.
Lights up when Comparative Output 2 is ON.
In the initial setting mode, pressing
・
the key changes the settable digit.
In the Set Value 1, 2 modes,
・
pressing the key changes the set
value to the high pressure side in
case of positive pressure type sensor
and to the high vacuum side in case
of vacuum pressure type sensor.
In the sensing mode, if the key is
・
pressed continuously for 4 sec. or more,
the display shows peak hold value.
In the initial setting mode, pressing
・
the key changes the set conditions.
In the Set Value 1, 2 modes,
・
pressing the key changes the set
value to the low pressure side in
case of positive pressure type sensor
and to the low vacuum side in case
of vacuum pressure type sensor.
In the sensing mode, if the key is
・
pressed continuously for 4 sec. or more,
the display shows bottom hold value.
Pressing the key changes the selected
・
mode to sensing mode, Set Value 1 (P1)
set mode and Set Value 2 (P2) set mode.
In the sensing mode, if the key is
・
pressed continuously for about 3 sec.,
key-protect can be set/released.
In the sensing mode, if the mode selection
・
key is pressed while pressing the increment
key ( ), the initial setting mode is obtained.
Cause
Overcurrent due to
short-circuit.
Pressure is being
applied during
zero-point adjustment.
Applied pressure exceeds
the upper limit of
displayable pressure range.
Positive
pressure
type
Applied pressure exceeds
the lower limit of
displayable pressure range.
Vacuum
pressure
type
Applied pressure exceeds
the lower limit of
displayable pressure range.
Positive
pressure
type
Applied pressure exceeds
the upper limit of
displayable pressure range.
pressure
type
Vacuum
11
procedure to change to analog bar display.
Analog bar display for positive pressure type sensor
Atm. pressure condition
DP2-21
100kPa
OUT2OUT1
MODE
0-ADJ
DP2-21
High pressure condition
100kPa
OUT2OUT1
MODE
0-ADJ
Analog bar display for vacuum pressure type sensor
Atm. pressure condition
DP2-20
-101.3kPa
OUT2OUT1
MODE
0-ADJ
DP2-20
High vacuum condition
-101.3kPa
OUT2OUT1
MODE
0-ADJ
③
⑥
In the sensing mode, if both the keys are pressed
simultaneously, zero-point adjustment is done.
Corrective action
Switch off the power
supply and check the
load.
Applied pressure at the pressure
port should be brought to
atmospheric pressure and zero-point
adjustment should be done again.
Applied pressure should
be brought within the
rated pressure range.
DP2-21
100kPa
OUT2OUT1
MODE
0-ADJ
DP2-20
-101.3kPa
OUT2OUT1
MODE
0-ADJ
9
OUTPUT MODES & THEIR
CHARACTERISTICS
Hysteresis mode ( )
● The common hysteresis of the comparative outputs
can be set, as desired, with the set values.
ON
Comparative
Output 1
OFF
ON
Comparative
Output 2
OFF
0
Set Value 1 (P1) Set Value 2 (P2)
Window comparator mode ( )
The comparative outputs can be turned ON or OFF by a pressure
●
which is within the pressure range set by Set Value 1 and Set Value 2.
ON
Comparative
Output 1
OFF
ON
Comparative
Output 2
OFF
0
Set Value 1 (P1)
When operating in window comparator mode ( ) Set
Value 1 (P1) and Set Value 2 (P2) should be set with a
difference of 3 digits or more. However, when the
pressure unit is set to 'psi' ( ), the difference should be 6
digits or more.
Dual output mode ( )
The outputs can be put to different use such as detection of
●
different kinds of objects, control function, alarm function etc.
Hysteresis
ON
Comparative
Output 1
OFF
ON
Comparative
Output 2
OFF
0
Set Value 1 (P1) Set Value 2 (P2)
Automatic sensitivity setting mode ( )
Using actual objects, if the pressure values for OK objects
●
and NG objects are input, then the sensor is automatically
set to the optimum pressure value (mid-value).
ON
Comparative
Output 1
OFF
ON
Comparative
Output 2
OFF
0
Set Value 1 (P1) Set Value 2 (P2)
10
PRESSURE UNITS
The pressure unit can be selected as per customer's requirement.
●
In case of positive pressure type, the pressure unit can be
●
changed from International System of Units (SI) 'kPa' or 'MPa'
2
', 'bar' or 'psi'. In case of vacuum pressure type, the
to 'kgf/cm
pressure unit can be changed from International System of
Units (SI) 'kPa' to 'kgf/cm
When the pressure unit is changed, the set values
・
and the measured value are automatically converted.
Please refer to ' SETTING ② Initial setting' for
・
the procedure to change the pressure unit.
inHg
mmHg psi bar
Note:
'MPa' in case of DP2-22□, DP2-42□ and DP2-62□.
Hysteresis
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
Hysteresis Hysteresis
Set Value 2 (P2)
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
Hysteresis: 1 digit
2 digits when using
psi unit
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
Hysteresis
Set Value 3 (P3)
2
', 'bar', 'psi', 'mmHg' or 'inHg'.
High pressure
(Positive pressure type)
High vacuum
(Vacuum pressure type)
11
International System
of Units (SI)
kPa (Note)
: Positive pressure type: Vacuum pressure type
Hysteresis:
1 digit or more
2 digits or more
when using psi unit
Hysteresis: 1 digit
2 digits when using
psi unit
Hysteresis: 1 digit
2 digits when using
psi unit
kgf/cm
2