3.5 - 90
OM7500SM
3.5
ELECTRICAL CHARACTERISTICS +5 Volt V
IN
= 10V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 4.92 5.08 V
V
IN
= 7.5V to 20V • 4.85 5.15 V
Line Regulation V
RLINE
VIN= 7.5V to 20V 5 mV
(Note 1)
• 12 mV
V
IN
= 8.0V to 12V 4 mV
• 10 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 12 mV
(Note 1)
• 25 mV
I
O
= 250mA to 750 mA 6 mV
• 15 mV
Standby Current Drain I
SCD
6 mA
• 6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 7.5V to 20V • 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA • 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
TA= 25°C, ∆V
OUT
= 100mV, I
O
=1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= 35V 1.2 A
(Note 2)
• 2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 66 dB
∆V
OUT
(Note 3) • 60dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) ∆t
INDIVIDUAL POSITIVE REGULATORS
ELECTRICAL CHARACTERISTICS +12 Volt V
IN
= 19V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 11.88 12.12 V
V
IN
= 14.5V to 27V • 11.64 12.36 V
Line Regulation V
RLINE
VIN= 14.5V to 27V 18 mV
(Note 1)
• 50 mV
V
IN
= 16V to 22V 9 mV
• 30 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 32 mV
(Note 1)
• 60mV
I
O
= 250mA to 750 mA 20 mV
• 40 mV
Standby Current Drain I
SCD
6.0 mA
• 6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 15V to 30V • 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA • 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
∆V
OUT
= 100mV, I
O
=1.0A • 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= 35V 1.2 A
(Note 2)
• 2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 61 dB
∆V
OUT
(Note 3) • 54 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 120 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.