Olympus CX41 User Manual

Page 1
Olympus is about life. About photographic innovations that capture precious moments of life. About advanced medical technology that saves lives. About information- and industry-related products that make possible a better living. About adding to the richness and quality of life for everyone. Olympus. Quality products with a
SYSTEM MICROSCOPE
UNIVERSAL
CX2 SERIES
Optics and performance outstanding in its class
Page 2
1
Advanced optical and system performance with excellent cost-efficiency
The evolution of this bestselling microscope delivers new, cost-efficient improvements in both optics and system performance. Newly equipped with Olympus' leading-edge UIS optical system, it provides significantly enhanced image clarity in a variety of observation methods, from brightfield to reflected light fluorescence. For all inspection and training applications in the fields of biology and medicine, the CX41 sets the pace for its class in both basic and system performance.
Page 3
Outstanding flat images from Plan C objectives
The CX41 provides images of outstanding brightness and clarity in a variety of observation modes. As well as Olympus' renowned UIS optics infinity system, it employs the newly developed PLC series of Plan Achromat objectives, which are made from carefully selected top quality glass and manufactured with the most rigorous precision. The result is a major improvement in image flatness, with the 10x and 40x objectives in particular providing images that are among the very best in this class of microscope. Transmitted light illumination is from a 6V, 30W high-intensity halogen light source.
F.N. 20 F.N. 20
PLC40xPLC10x
Conventional
objective
Conventional
objective
40x10x
Flatness area comparison
Page 4
3
Excellent cost-performance in reflected light fluorescence and other observation methods
Dry darkfield condenser / CX-DCD
This dry-type darkfield condenser gives a superior darkfield effect without the need for immersion in oil. Suitable for use at 10x and 40x magnifications.
Darkfield central stop / CH2-DS
For darkfield observations from 4x to 40x.
* Separate filter holder (CH2-FH) or attachment lens (CX-AL) required.
Low magnification adapter /CX-LA
Use of the 2x low magnification objective allows macro observation.
Simple phase contrast attachment / CX-PH1, 2, 3
For phase-contrast observations at 10x, 40x and 100x.
Slide condenser / CX-SLC Brightfield condenser / CH3-CD
These Abbe type condensers allow brightfield observations from 4x to 100x. Accurate centering is provided by the attachment lens (CX-AL) and the iris diaphragm, to exclude unnecessary light and obtain bright Koehler illumination right across the magnification range. These highly economical condensers enable phase­contrast and darkfield observations by simply adding basic accessories.
Reflected light fluorescence attachment / CX-RFL-2
Users can swap between blue or green excitation and transmitted light observations. UIS optics provide bright fluorescence images, with no intermediate magnifications when changing from transmitted light to fluorescence observation. Standard PLC objectives can be used without replacement.
Simple polarizing condenser / CH3-CDP
With the optional plate adapter U-TAD, polarizing observations from 4x to 100x using a tint plate can be performed. A U-GAN analyzer is provided for gout inspection. Polarizing objectives from 4x to 100x are available.
* Separate polarizer U-POT and analyzer U-ANT required.
Page 5
4
Phase-contrast condenser / CX-PCD
The multi-purpose CX-PCD condenser allows observation of brightfield, phase­contrast and darkfield images without exchanging condensers. Phase-contrast observation from 10x to 100x and darkfield observation from 10x to 40x is allowed.
Dependable basic performance assures outstanding operational convenience
Easy transportation and installation
The CX41 is eminently portable, with convenient handgrips at the front and back of the frame and no sudden, inconvenient protrusion of the stage guide.
Move the specimen with just one finger
Rubber grips are provided for the stage handles, allowing the specimen to be moved smoothly with just one finger. The slim body and conveniently positioned controls ensure that everything is within easy reach, so operators can maintain a natural posture.
Tilting binocular tube
The tilting binocular tube lets each operator select the most suitable and comfortable eyepoint a valuable contribution to reducing fatigue in extended observation sessions.
Inward-facing quintuple revolving nosepiece
The quintuple revolving nosepiece enables a wide range of magnification observations and various combinations of objectives. Unrestricted access to the space in front of the objective allows specimens to be exchanged quickly and easily.
Torque adjustable focusing knob
The torque of the coarse focusing knob can be adjusted, to suit different operators' needs and to make focusing smooth and easy while keeping the hands on the desk. A stage upper limit stopper is also provided.
Rackless stage with enhanced operability
To keep the work area clear, and to avoid interference with observation operations, the X-direction travel guide does not extend out from the side of the stage. The main and sub scale displays are designed for easy read-out.
Anti-fungus treatment
The treatment applied to the observation tubes, eyepieces and objectives, protects quality of optical parts even in high humidity regions.
Page 6
Trinocular tube / U-CTR30-2
Still digital (DP11) or video cameras can be attached for on-site/remote illustration of educational/discussion meetings.
Trinocular intermediate attachment / U-TRU
A binocular tube on its own allows photomicrography. Combination with this intermediate attachment type trinocular tube makes it possible to attach photographic equipment and a video camera at the same time.
Drawing attachment / U-DA
The drawing attachment projects an image of the pencil and drawing surface into the visual field.
More accessories, more observation versatility
Easy digital imaging
A simple eyepiece adapter enables an Olympus digital camera to be attached to binocular tube U-CBI30-2 an easy, practical and cost-efficient means of obtaining digital images.
Arrow pointer / U-APT
Enables insertion of an LED arrow for display in a photomicrograph.
2x magnification changer / U-ECA
Magnification is doubled by engaging the auxiliary 2x lens.
Eyepoint adjuster / U-EPA2
Allows the eyepoint position to be raised by 30mm. Up to two eyepoint adjusters can be attached between the frame arm and observation tube.
U-DA
U-DAL10x
CX41+DP11
Dual observation attachment / U-DO3
Enables dual, simultaneous observation of a single specimen from the same direction with equal magnification and brightness for both operators. A pointer can be used to indicate specific sections of the specimen to simplify the training process and promote discussion.
5
Page 7
San-Ei building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku, Tokyo, Japan Postfach 10 49 08, 20034, Hamburg, Germany 2 Corporate Center Drive, Melville, NY 11747-3157, U.S.A. 491B River Valley Road, #12-01/04 Valley Point Office Tower, Singapore 248373 2-8 Honduras Street, London EC1Y OTX, United Kingdom. 104 Ferntree Gully Road, Oakleigh, Victoria, 3166, Australia
Specifications are subject to change without any obligation on the part of the manufacturer.
ISO9001
Certificate No.69372
Certification
Design and production
adheres to ISO9001
international quality standard .
ISO 9001
Accredited by the Dutch Council for
Accreditation
ISO14001
ISO 14001
Design and production at the Olympus
Optical Co. Ltd. Ina Plant conforms with
ISO14001 specifications for
environmental management systems.
Certification
Certificate No. 961049
Web site address: http://www.olympus.com
Specifications
Dimensions
Item CX41 Optical system UIS (Universal Infinity-corrected) optical system Illumination Built-in transmitted Koehler illuminator
6V30W halogen bulb 100-120V/220-240Vg 0.85/0.45A 50/60Hz
Focusing Stage height movement by roller guide (rack & pinion) Stroke per rotation: 36.8mm
Full stroke range: 25mm Upper limit stopper Tension adjustment on coarse focus adjustment knob Revolving nosepiece Fixed quintuple nosepiece with inward tilt Observation tube Type U-CBI30-2, Binocular U-CTR30-2, Trinocular
Field number 20 20 Tube inclination 30º 30º Interpupillary distance adjustment range 48-75mm 48-75mm Light path selector None None (Bi 50%, Video/Photo 50% fixed)
Stage Size 188(W)x134(D)mm
Movement range 76mm X-direction x 50mm Y-direction Specimen holder Double slide holder Rubber grip Equipped as standard
Condenser Type Abbe condenser, with built-in daylight filter
N.A. 1.25 with oil immersion Aperture iris diaphragm Built-in
Dimensions & weight 233(W)x432(H)x367.5(D)mm, approximately 8.5kg (approximately 18.7 lb.)
(Unit: mm) Objectives, Plan Achromat
Eyepiece
PLC Numerical Aperture Working Distance
(N.A.) (W.D.) 4x 0.10 22.0mm 10x 0.25 10.5mm 40x 0.65 0.56mm 100xOil 1.25 0.13mm
Field Number (F.N.)
WHB10x 20
423
160
233
* The length marked with an asterisk (*) may vary accoding to interpupillary distance. Distance for figure shown is 62mm.
*420
212
245
327
Loading...