Olympus is about life. About photographic innovations that capture precious moments of life. About advanced 
medical technology that saves lives. About information- and industry-related products that make possible a better living. 
About adding to the richness and quality of life for everyone. Olympus. Quality products with a
UNIVERSAL 
INFINITY SYSTEM
CX2 SERIES
Optics and performance outstanding in its class
 

1
Advanced optical and system performance 
with excellent cost-efficiency
The evolution of this bestselling microscope delivers new, 
cost-efficient improvements in both optics and system performance.  
Newly equipped with Olympus' leading-edge UIS optical system, 
it provides significantly enhanced image clarity in a variety of 
observation methods, from brightfield to reflected light fluorescence.  
For all inspection and training applications in the fields of biology 
and medicine, the CX41 sets the pace for its class in both 
basic and system performance.
 

Outstanding flat images from Plan C objectives
The CX41 provides images of outstanding brightness and clarity in a variety of observation 
modes. As well as Olympus' renowned UIS optics infinity system, it employs the newly 
developed PLC series of Plan Achromat objectives, which are made from carefully selected 
top quality glass and manufactured with the most rigorous precision. The result is a major 
improvement in image flatness, with the 10x and 40x objectives in particular providing images 
that are among the very best in this class of microscope. Transmitted light illumination is 
from a 6V, 30W high-intensity halogen light source.
F.N. 20 F.N. 20
PLC40xPLC10x
Conventional
objective
Conventional
objective
40x10x
Flatness area comparison
 

3
Excellent cost-performance in reflected light fluorescence 
and other observation methods
Dry darkfield condenser / CX-DCD
This dry-type darkfield condenser gives a 
superior darkfield effect without the need for 
immersion in oil. 
Suitable for use 
at 10x and 40x 
magnifications.
Darkfield central stop / CH2-DS
For darkfield observations from 4x to 40x.
* Separate filter holder (CH2-FH) or attachment lens (CX-AL) 
required.
Low magnification adapter /CX-LA
Use of the 2x low magnification objective allows 
macro observation. 
Simple phase contrast attachment / 
CX-PH1, 2, 3
For phase-contrast observations at 10x, 
40x and 100x. 
Slide condenser / CX-SLC 
Brightfield condenser / CH3-CD
These Abbe type condensers allow 
brightfield observations from 4x to 
100x. Accurate centering is provided 
by the attachment lens (CX-AL) and the 
iris diaphragm, to exclude unnecessary 
light and obtain bright Koehler 
illumination right across the 
magnification range. These highly 
economical condensers enable phasecontrast and darkfield observations by 
simply adding basic accessories.
Reflected light fluorescence 
attachment / CX-RFL-2
Users can swap between blue or green 
excitation and transmitted light 
observations. UIS optics provide bright 
fluorescence images, with no intermediate 
magnifications when changing from 
transmitted light to fluorescence 
observation. Standard PLC objectives can 
be used without replacement.
Simple polarizing condenser / 
CH3-CDP
With the optional plate adapter U-TAD, 
polarizing observations from 4x to 100x 
using a tint plate can be performed.  
A U-GAN analyzer is provided for gout 
inspection. Polarizing objectives from 
4x to 100x are 
available. 
* Separate polarizer 
U-POT and analyzer 
U-ANT required.
 

4
Phase-contrast condenser / CX-PCD
The multi-purpose CX-PCD condenser 
allows observation of brightfield, phasecontrast and darkfield images without 
exchanging condensers. Phase-contrast 
observation from 
10x to 100x and 
darkfield 
observation from 
10x to 40x is 
allowed.
Dependable basic performance assures 
outstanding operational convenience
Easy transportation and installation
The CX41 is eminently portable, with 
convenient handgrips at the front and back 
of the frame and no sudden, inconvenient 
protrusion of the stage guide.
Move the specimen with just one finger
Rubber grips are provided for the stage 
handles, allowing the specimen to be moved 
smoothly with just one finger. The slim body 
and conveniently positioned controls ensure 
that everything is within easy reach, so 
operators can maintain a natural posture.
Tilting binocular tube
The tilting binocular tube lets each operator 
select the most suitable and comfortable 
eyepoint — a valuable contribution to 
reducing fatigue in extended observation 
sessions.
Inward-facing quintuple revolving 
nosepiece
The quintuple revolving nosepiece enables a 
wide range of magnification observations 
and various combinations of objectives. 
Unrestricted access to the space in front of 
the objective allows specimens to be 
exchanged quickly and easily.
Torque adjustable focusing knob
The torque of the coarse focusing knob can 
be adjusted, to suit different operators' needs 
and to make focusing smooth and easy while 
keeping the hands on the desk. A stage 
upper limit stopper is also provided.
Rackless stage with enhanced operability
To keep the work area clear, and to avoid 
interference with observation operations, 
the X-direction travel guide does not extend 
out from the side of the stage. The main and 
sub scale displays are designed for easy 
read-out.
Anti-fungus treatment
The treatment applied to the 
observation tubes, eyepieces and 
objectives, protects quality of optical 
parts even in high humidity regions.
 

Trinocular tube / U-CTR30-2
Still digital (DP11) or video cameras can 
be attached for on-site/remote illustration 
of educational/discussion meetings. 
Trinocular intermediate attachment / 
U-TRU
A binocular tube on its own allows 
photomicrography. Combination with 
this intermediate attachment type 
trinocular tube makes it possible to attach 
photographic equipment and a video 
camera at the same time.
Drawing attachment / U-DA
The drawing attachment projects an image 
of the pencil and drawing surface into the 
visual field.
More accessories, more observation versatility
Easy digital imaging
A simple eyepiece adapter enables an 
Olympus digital camera to be attached to 
binocular tube U-CBI30-2 — an easy, 
practical and cost-efficient means of 
obtaining digital images.
Arrow pointer / U-APT
Enables insertion of an LED arrow for 
display in a photomicrograph.
2x magnification changer / U-ECA
Magnification is doubled by engaging the 
auxiliary 2x lens.
Eyepoint adjuster / U-EPA2
Allows the eyepoint position to be raised by 
30mm. Up to two eyepoint adjusters can 
be attached between the frame arm and 
observation tube.
U-DA
U-DAL10x
CX41+DP11
Dual observation attachment / U-DO3
Enables dual, simultaneous observation of 
a single specimen from the same direction 
with equal magnification and brightness for 
both operators. A pointer can be used to 
indicate specific sections of the specimen to 
simplify the training process and promote 
discussion.
5
 

San-Ei building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku, Tokyo, Japan 
Postfach 10 49 08, 20034, Hamburg, Germany 
2 Corporate Center Drive, Melville, NY 11747-3157, U.S.A. 
491B River Valley Road, #12-01/04 Valley Point Office Tower, Singapore 248373 
2-8 Honduras Street, London EC1Y OTX, United Kingdom. 
104 Ferntree Gully Road, Oakleigh, Victoria, 3166, Australia
Specifications are subject to change without any obligation on the part of the manufacturer.
ISO9001
Certificate No.69372
Certification
Design and production
 adheres to ISO9001
 international quality standard .
ISO 9001
Accredited by the 
Dutch Council for 
Accreditation
ISO14001
ISO 14001
Design and production at the Olympus 
Optical Co. Ltd. Ina Plant conforms with 
ISO14001 specifications for 
environmental management systems.
Certification
Certificate No. 961049
Web site address: http://www.olympus.com
Specifications
Dimensions
Item CX41 
Optical system UIS (Universal Infinity-corrected) optical system 
Illumination Built-in transmitted Koehler illuminator
6V30W halogen bulb 
100-120V/220-240Vg 0.85/0.45A 50/60Hz
Focusing •Stage height movement by roller guide (rack & pinion)   •Stroke per rotation: 36.8mm   
•Full stroke range: 25mm   •Upper limit stopper   •Tension adjustment on coarse focus adjustment knob 
Revolving nosepiece Fixed quintuple nosepiece with inward tilt 
Observation tube Type U-CBI30-2, Binocular U-CTR30-2, Trinocular
Field number 20 20 
Tube inclination 30º 30º 
Interpupillary distance adjustment range 48-75mm 48-75mm 
Light path selector None None (Bi 50%, Video/Photo 50% fixed)
Stage Size 188(W)x134(D)mm
Movement range 76mm X-direction x 50mm Y-direction 
Specimen holder Double slide holder 
Rubber grip Equipped as standard
Condenser Type Abbe condenser, with built-in daylight filter
N.A. 1.25 with oil immersion 
Aperture iris diaphragm Built-in
Dimensions & weight 233(W)x432(H)x367.5(D)mm, approximately 8.5kg (approximately 18.7 lb.) 
(Unit: mm) Objectives, Plan Achromat
Eyepiece
PLC Numerical Aperture Working Distance
(N.A.) (W.D.) 
4x 0.10 22.0mm 
10x 0.25 10.5mm 
40x 0.65 0.56mm 
100xOil 1.25 0.13mm
Field Number (F.N.)
WHB10x 20
423
160
233
* The length marked with an asterisk (*) may vary accoding to interpupillary distance. Distance for figure shown is 62mm.
*420
212
245
327