OLYMPUS C-3040 Zoom Repair Procedure v1

D. REPAIR PROCEDURE
C-3040 Zoom
D. REPAIR PROCEDURE
[1] TROUBLESHOOTING GUIDE .................................................................................. D-2
POWER LOSS INOPERATIVE ................................................................................ D-2
NO PICTURE ...........................................................................................................D-2
SERVER_DIS
D-1
Ver. 1
[1] TROUBLESHOOTING GUIDE
D. REPAIR PROCEDURE
C-3040 Zoom
POWER LOSS INOPERTIVE
CHECK PFC include
IC301-91 (SCAN IN 0)
PULSE INPUT
YES
IC302-7 (UNREG)
HIGH
IC301-81
(VDD)
HIGH
IC301-84
(RESET)
HIGH
IC301-85
(BAT OFF)
HIGH
IC301-80
OSCILLATION
YES
IC301-82
OSCILLATION
YES
NO
POWER SW, CN301,
LOW
LOW
LOW
LOW
CHECK ST1, CA2
CHECK IC302
CHECK IC302, R3051
CHECK R3052
NO
NO
CHECK X3001
CHECK X3002, R3004, C3001,
R3021
C3002
TAKING INOPERATIVE
PUSH SHUTTER
BUTTON
IC301-3, 7
(SCAN IN 3)
PULSE INPUT
YES
CN301-7, 8
(P ON, P(A) ON)
HIGH
CN301-6, 12, 13
HIGH
YES
SERIAL
COMMUNICATION
OK
CHECK CA2
CHECK PFC include
NO
POWER SW, CN301,
LOW
NO
NG
R3023, R3024
CHECK IC301,
Q3005, Q3006, ST1
CHECK
IC301, CA2, ST1
CHECK IC301, CA2
CHECK IC301
NO PICTURE
CLK (72MHz)
INPUT TO
IC102-280 (CLK IN 1)
NO
CLK (36 MHz)
INPUT TO
IC101-132 (CLK IN 1)
OK
IC101-61 (ZAS)
OK
IC101-52 (ZBREQ)
OK
IC101-56
(ZBGRNT)
OK
IC101-118, 119
(IRL1, 2)
OK
CHECK SOLDERING OF
EACH CPU AND
MEMORY PIN
MAIN CLOCK FOR SYSTEM OPERATION
YES
NO OPERATION IF ABSENT CHECK X1101 OSCILLATOR AND IC111
NG
BASIC CPU BLOCK CHECK IC102-278
ALWAYS APPEARS WHEN CPU, ETC. IS ACCESSED
NG
CHECK IF CPU IS READKING PROGRAM, AND CHECK ADDRESS AND DATA BUS OF IC121
REQUEST FOR USE OF DATA BUS FROM
NG
ASIC TO CPU NO DMA TRANSMISSION IF ABSENT
RECEIVES ZBREQ SIGNAL AND GIVES PERMISSION
NG
TO ASIC FOR USE OF DATA BUS NO DMA TRANSMISSION IF ABSENT
INCORRECT HANDSHAKING BETWEEN 8-BIT
NG
CPU AND RS-232C CHECK EACH INTERFACE
SERVER_DIS
D-2
Ver. 1
Loading...