OLYMPUS C-3000 Zoom, С-3030 Zoom Adjustment Method V3R4

Page 1
C. ADJUSTMENT METHOD
C-3030ZOOM/C-3000ZOOM
C. ADJUSTMENT METHOD
C-3030ZOOM/C-3000ZOOM
[1] TABLE FOR SERVICING TOOLS .......................................................................... C-2
[2] EQUIPMENT ........................................................................................................... C-2
[3] ADJUSTMENT ITEMS AND ORDER ..................................................................... C-2
[4] SETUP ....................................................................................................................C-2
[6] ADJUSTMENT ........................................................................................................C-4
1. IC501 OSCILLATION FREQUENCY ADJUSTMENT ........................................ C-4
2. 5.1 V (A) VOLTAGE ADJUSTMENT................................................................... C-4
3. 13.0 V (L) VOLTAGE ADJUSTMENT .................................................................C-4
4. LENS ADJUSTMENT ........................................................................................ C-4
5. AWB ADJUSTMENT ....................................................................................... C-4,5
6. COLOR MATRIX ADJUSTMENT .......................................................................C-5
7. CCD DEFECT DETECT ADJUSTMENT ...........................................................C-5
8. LCD PANEL ADJUSTMENT.............................................................................. C-5
8-1. LCD H AFC ADJUSTMENT .......................................................................C-5
8-2. LCD GAIN ADJUSTMENT ......................................................................... C-5
8-3. LCD RGB OFFSET ADJUSTMENT ...........................................................C-6
8-4. LCD RED BRIGHTNESS ADJUSTMENT ................................................C-6
8-5. LCD BLUE BRIGHTNESS ADJUSTMENT ...............................................C-6
8-6. LCD TINT ADJUSTMENT (FOR PAL) ....................................................... C-6
[7] ADJUSTMENT VALUES ......................................................................................... C-7
[8] ADJUSTMENT ITEMS .............................................................................................C-8
SIEMENS STAR CHART .............................................................................................. C-9
CHECKING OF LENS UNIT ....................................................................................... C-17
SERVER_DIS
C-1-1
Ver.3/Rev.4
Page 2
C. ADJUSTMENT METHOD
C-3000ZOOM2
C. ADJUSTMENT METHOD
C-3000ZOOM2
[1] TABLE FOR SERVICING TOOLS ........................................................................ C-10
[2] EQUIPMENT ......................................................................................................... C-10
[3] ADJUSTMENT ITEMS AND ORDER ...................................................................C-10
[4] SETUP ..................................................................................................................C-10
[5] CONNECTING THE CAMERA TO THE COMPUTER .......................................... C-11
[6] ADJUSTMENT ......................................................................................................C-12
1. IC501 OSCILLATION FREQUENCY ADJUSTMENT ...................................... C-12
2. 5.1 V (A) VOLTAGE ADJUSTMENT................................................................. C-12
3. 13.0 V (L) VOLTAGE ADJUSTMENT ...............................................................C-12
4. LENS ADJUSTMENT ...................................................................................... C-12
5. AWB ADJUSTMENT ................................................................................... C-12,13
6. COLOR MATRIX ADJUSTMENT ..................................................................... C-13
7. CCD DEFECT DETECT ADJUSTMENT .........................................................C-13
8. LCD PANEL ADJUSTMENT............................................................................ C-13
8-1. LCD H AFC ADJUSTMENT .....................................................................C-13
8-2. LCD GAIN ADJUSTMENT ....................................................................... C-13
8-3. LCD RGB OFFSET ADJUSTMENT .........................................................C-14
8-4. LCD RED BRIGHTNESS ADJUSTMENT ..............................................C-14
8-5. LCD BLUE BRIGHTNESS ADJUSTMENT .............................................C-14
8-6. LCD TINT ADJUSTMENT (FOR PAL) ..................................................... C-14
[7] ADJUSTMENT VALUES .......................................................................................C-15
[8] ADJUSTMENT ITEMS ...........................................................................................C-16
SIEMENS STAR CHART .............................................................................................. C-9
CHECKING OF LENS UNIT ....................................................................................... C-17
SERVER_DIS
C-1-2
Ver.3/Rev.4
Page 3
[1] Table for Servicing Tools
Ref. No. Name
J-1 J-2
J-3 J-4 J-5 Extension cord J-6
Note: J-1 color viewer is 100 - 110 VAC only.
Color viewer 5,100 K Siemens star chart Calibration software Extension cord
Chart for color adjustment
Qt’y
1 1 1
1 1
1
J-1 J-2
J-3
J-4/J-5
C. ADJUSTMENT METHOD
[2] Equipment
1. Oscilloscope
Part code
VJ8-0007
VJ8-0169
VJ8-0162
VJ8-0165 VJ8-0155
2. Digital voltmeter
3. AC adaptor
4. IBM R -compatible PC
5. DC regulated power supply
[3] Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment
2. 5.1 V (A) Voltage Adjustment
3. 13.0 V (L) Voltage Adjustment
4. Lens Adjustment
5. AWB Adjustment
6. Color matrix Adjustment
7. CCD Defect Detect Adjustment
8. LCD Panel Adjustment 8-1. LCD H AFC Adjustment 8-2. LCD Gain Adjustment 8-3. LCD RGB Offset Adjustment 8-4. LCD Red Brightness Adjustment 8-5. LCD Blue Brightness Adjustment 8-6. LCD Tint Adjustment (for PAL) Note:
1. If the lens, CCD, board and changing the part in item 4-7 replace, it is necessary to adjust again. Item 5-7 adjust ments should be carried out in sequence.
C-3030ZOOM/C-3000ZOOM
J-6
[4] Setup
1. System requirements
Windows 95 or 98 IBM R -compatible PC with 486 or higher processor CD-ROM drive
3.5-inch high-density diskette drive Serial port with standard RS-232C interface 8 MB RAM Hard disk drive with at least 15 MB available VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into your
diskette drive.
2. Open Explorer.
3. Copy the DSC Cal folder on the floppy disk in the FD drive
to a folder on the hard disk.
C-2 Ver.3SERVER_DIS
Page 4
C-3030ZOOM/C-3000ZOOM
C. ADJUSTMENT METHOD
[5] Connecting the camera to the computer
1. Turn off both camera and computer.
2. Locate the port cover on the side of the camera. Press on the arrows and slide the cover down to open it.
3. Line up the arrow on the cable connector with the notch on the camera's serial port. Insert the connector.
4. Locate a serial port on the back of your computer. You may have two serial ports labeled COM1 and COM2, or the ports may be labeled with icons. If you have two serial ports available, use port 1 to connect your camera.
5. Line up the serial connector on the cable with one of the serial ports on your computer, and insert the connector.
6. Turn on the camera and your computer system.
Serial cable
To COM1 serial port
AC adaptor
C-3Ver.3 SERVER_DIS
Page 5
[6] Adjust Specifications
[ST1 board (Side B)]
C. ADJUSTMENT METHOD
Adjustment method:
1.Adjust with VR504 to 13.00
4. Lens Adjustment
C-3030ZOOM/C-3000ZOOM
± 0.05 V.
VR501
CL524
(Side A)
VR504
VR502
CL522
CL501
(Side A)
Q5001
Collector
(Side A)
Note:
1. Voltage adjustment is necessary to repair in the ST1 board and replace the parts.
2. Carry out adjustment with disconnect wires for storbe.
Preparation:
1. Connect the SY1 board (CN301) and the CA2 board (CN106) with extension cord. (VJ8-0165)
2. Connect the ST1 board (CN501) and the CA2 board (CN104) with extension cord. (VJ8-0162)
3. Connect LCD panel.
4. Insert the card.
5. Turn on the power switch, and then set the camera mode.
1. IC501 Oscillation Frequency Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR501 to 200 ± 1 kHz.
Q5001 Collector or CL501 Frequency counter VR501 200 ± 1 kHz
Serial cable
Camera
150 cm ± 3 cm
Siemens
star chart
Preparation:
POWER switch: ON
Adjustment condition:
Siemens star chart (A3) Fluorescent light illumination with no flicker (incandescent light cannot be used.)
Illumination above the subject should be 400 lux
± 10%.
Adjustment method:
1. Set the siemens star chart 150 cm ± 3 cm so that it be­comes center of the screen.
2. Double-click on the DscCalDi124.
3. Click the “Focus”, and Click the “Yes”.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
5. AWB Adjustment
2. 5.1 V (A) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR502 to 5.10
CL524 Digital voltmeter VR502
5.10
± 0.05 V
± 0.05 V.
3. 13.0 V (L) V oltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
CL522 Digital voltmeter VR504
13.00
± 0.05 V
Serial cable
Camera
All white pattern
Color viewer (5,100K)
C-4 Ver.3SERVER_DIS
Page 6
C-3030ZOOM/C-3000ZOOM
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. (Do not enter any light.)
2. Double-click on the DscCalDi124.
3. Click the “AWB”, and click the “Yes”.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
C. ADJUSTMENT METHOD
6. Color Matrix Adjustment
8. LCD Panel Adjustment
[CA2 board (Side A)]
CL413
CL414
CL415
Serial cable
Camera
Preparation:
POWER switch: ON
Adjustment method:
1. Set the color adjustment chart to the color viewer. (Do not enter any light.)
2. Set the color adjustment chart so that it becomes center of the screen.
3. Double-click on the DscCalDi124.
4. Click the “UV Matrix”, and Click the “Yes”.
5. Adjustment values will appear on the screen.
6. Click the OK.
15 cm ± 1 cm
All white pattern color
viewer (5,100K) and
color matrix adjustment chart
7. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi124.
2. Select CCD Defect Detection on the LCD “Type”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
8-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON Card switch: ON
Adjusting method:
1. Double-click on the DscCalDi124.
2. Select 0 on the LCD “H AFC”.
3. While watching the LCD monitor, adjust ”H AFC” so that the edge of the LCD adjustment frame are the same dis­tance from the left and right edge of the LCD screen. (A = B)
LCD
LCD screen
A
FPC
adjustment frame
B
8-2. LCD Gain Adjustment
Adjusting method:
1. Adjust LCD “Gain” so that the amplitude of the CL415 wave­form is 1.0 Vp-p ± 0.1 V.
1.0V
±0.1Vp-p
CL415 waveform
C-5Ver.3 SERVER_DIS
Page 7
C. ADJUSTMENT METHOD
8-3. LCD RGB Offset Adjustment
Adjusting method:
1. Adjust LCD “RGB Offset” so that the amplitude of the CL415 waveform is 5.1 Vp-p
Note:
8-2. LCD Gain adjustment should always be carried out first.
± 0.1 V.
5.1V
±0.1Vp-p
CL415 waveform
C-3030ZOOM/C-3000ZOOM
8-5. LCD Blue Brightness Adjustment
Adjusting method:
1. Adjust LCD “B Bright” so that the amplitude of the CL413 waveform is VG
waveform.
Note:
8-2. LCD Gain adjustment and 8-3. LCD RGB Offset adjust­ment have done.
± 0.1 V with respect to the CL415 (VG)
VG
8-4. LCD Red Brightness Adjustment
Adjusting method:
1. Adjust LCD “R Bright” so that the amplitude of the CL414 waveform is VG
waveform.
Note:
8-2. LCD Gain adjustment and 8-3. LCD RGB Offset adjust­ment should always be carried out first.
± 0.1 V with respect to the CL415 (VG)
VG
CL415 waveform
CL415 waveform
VG±
0.1Vp-p
CL413 waveform
8-6. LCD Tint Adjustment (for P AL)
Adjusting method:
1. Adjust “Tint” so that the amplitude of CL415 waveform is minimum.
Note:
8-6. LCD TINT adjustment should always be carried out last.
a
CL414 waveform
VG±
0.1Vp-p a
a
a
C-6 Ver.3SERVER_DIS
Page 8
C-3030ZOOM/C-3000ZOOM
C. ADJUSTMENT METHOD
[ 7 ] Adjustment Values
Explanation of adjustment values
Adjustment values are values which have been estimated statistically from the distribution of adjustment values ob­tained from similar machine models and prototypes. Accord­ingly these values should be used as a guide only. Because these values are guides, equipment which is in good working order may still produce values which are out­side the adjustment value ranges, so that the equipment should be operated in order to determine whether it is in fact operational or defective.
Range of adjustment values
(1) Lens adjustment ranges
(2) AWB adjustment ranges
[How to read a dialog of adjustment value] “WD=WD1,WD2,WD3”
[Adjustment value] WD1: 200 to 400 WD2: 128(fixed value) WD3: 200 to 400
[Adjustment value] STD_AFPOS : Within 15 and 120
Note :STD_AFPOS = “ 0 “ means NG.
(3) Color matrix adjustment ranges
[How to read a dialog of adjustment value] “UD=UD0,UD1,UD2,UD3” “UC=UC0,UC1,UC2,UC3”
[Adjustment value] UD0: 40 to 160 UD1: 180 to 256, 0 to 60 UD2: 180 to 256, 0 to 60 UD3: 40 to 160
Adjustment values are normal except following cases. It does not detect any signal from CCD. In this case, adjustment values are all “1”. UD0: 1 UD1: 1 UD2: 1 UD3: 1
C-7Ver.3 SERVER_DIS
Page 9
C. ADJUSTMENT METHOD
C-3030ZOOM/C-3000ZOOM
[8] Adjustment Items
Changed repair parts
Adjustment items
CCD 1 IC501 Oscillation Frequency Adjustment *1 2 5.1V(A) Voltage Adjustment *1 3 13.0V(L) Voltage Adjustment *1 4 Lens Adjustment 5 AWB Adjustment 6 Color Matrix Adjustmen 7 CCD Defect Detect Adjustment
{{{ { {{{ { {{{ { {{{ {
8-1 LCD H AFC Adjustment 8-2 LCD Gain Adjustment 8-3 LCD RGB Offset Adjustment 8-4 LCD Red Brightness Adjustment 8-5 LCD Blue Brightness Adjustment 8-6 LCD Tint Adjustment (For PAL)
*1)There is no need that you adjust the provided ST1when changing it without changing the parts of component level.
LENS CA1 ST1
{ { {
CA2
{ { { { { {
C-8 Ver.3SERVER_DIS
Page 10
C. ADJUSTMENT METHOD
C-3030ZOOM/C-3000ZOOM
C-9 Ver. 3
Page 11
C. ADJUSTMENT METHOD C-3000ZOOM2
[1] Table for Servicing Tools
Ref. No. Name
J-1 J-2 J-3 J-4
J-5 Extension cord J-6
Note: J-1 color viewer is 100 - 110 VAC only.
Color viewer 5,100 K Siemens star chart Calibration software Extension cord
Chart for color adjustment
Number
1 1 1 1 1 1
J-1 J-2
J-3
J-4/J-5
Part code
VJ8-0007
VJ8-0173
VJ8-0162 VJ8-0165 VJ8-0155
[2] Equipment
1. Oscilloscope
2. Digital voltmeter
3. AC adaptor
4. IBM R -compatible PC
5. DC regulated power supply
[3] Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment
2. 5.1 V (A) Voltage Adjustment
3. 13.0 V (L) Voltage Adjustment
4. Lens Adjustment
5. AWB Adjustment
6. Color matrix Adjustment
7. CCD Defect Detect Adjustment
8. LCD Panel Adjustment 8-1. LCD H AFC Adjustment 8-2. LCD Gain Adjustment 8-3. LCD RGB Offset Adjustment 8-4. LCD Red Brightness Adjustment 8-5. LCD Blue Brightness Adjustment 8-6. LCD Tint Adjustment (for PAL) Note:
1. If the lens, CCD, board and changing the part in item 4­7 replace, it is necessary to adjust again. Item 5-7 ad­justments should be carried out in sequence.
J-6
[4] Setup
1. System requirements
Windows 95 or 98 IBM R -compatible PC with 486 or higher processor CD-ROM drive
3.5-inch high-density diskette drive Serial port with standard RS-232C interface or USB port 8 MB RAM Hard disk drive with at least 15 MB available VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into
your diskette drive.
2. Open Explorer.
3. Copy the DSC Cal folder on the floppy disk in the FD
drive to a folder on the hard disk.
3. Installing USB drive
Install the USB drive with camera or connection kit for PC.
C-10 Ver.3SERVER_DIS
Page 12
C. ADJUSTMENT METHODC-3000ZOOM2
[5] Connecting the camera to the computer
1. Turn off both camera and computer.
2. Line up the arrow on the serial cable connector with the notch on the camera's serial port. Insert the connector. In case of USB cable, line up the arrow on the USB cable connector with the notch on the camera's USB port. Insert the connector.
3. Line up the serial connector on the serial cable with the serial port on your computer, and insert the connector. In case of USB cable, line up the USB connector on the USB cable with the USB port on your computer, and insert the connector.
4. Turn on the camera and your computer system.
USB cable
Serial cable
To serial port or USB port
AC adaptor
C-11Ver.3 SERVER_DIS
Page 13
[6] Adjust Specifications
[ST1 board (Side B)]
C. ADJUSTMENT METHOD C-3000ZOOM2
Adjustment method:
1.Adjust with VR504 to 13.00 ± 0.05 V.
4. Lens Adjustment
VR501
CL524
(Side A)
VR504
VR502
CL522
CL501
(Side A)
Q5001
Collector
(Side A)
Note:
1. Voltage adjustment is necessary to repair in the ST1 board and replace the parts.
2. Carry out adjustment with disconnect wires for storbe.
Preparation:
1. Connect the SY1 board (CN301) and the CA2 board (CN106) with extension cord. (VJ8-0165)
2. Connect the ST1 board (CN501) and the CA2 board (CN104) with extension cord. (VJ8-0162)
3. Connect LCD panel.
4. Insert the card.
5. Turn on the power switch, and then set the camera mode.
1. IC501 Oscillation Frequency Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR501 to 200 ± 1 kHz.
Q5001 Collector or CL501 Frequency counter VR501 200 ± 1 kHz
Serial cable
Camera
150 cm ± 3 cm
Siemens
star chart
Preparation:
POWER switch: ON
Adjustment condition:
Siemens star chart (A3) Fluorescent light illumination with no flicker (incandescent light cannot be used.) Illumination above the subject should be 400 lux ± 10%.
Adjustment method:
1. Set the siemens star chart 150 cm ± 3 cm so that it be­comes center of the screen.
2. Double-click on the DscCalDi125.
3. Click the “Focus”, and Click the “Yes”.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
5. AWB Adjustment
2. 5.1 V (A) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR502 to 5.10 ± 0.05 V.
CL524 Digital voltmeter VR502
5.10
± 0.05 V
3. 13.0 V (L) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
CL522 Digital voltmeter VR504
13.00
± 0.05 V
Serial cable
Camera
All white pattern
Color viewer (5,100K)
C-12 Ver.3SERVER_DIS
Page 14
C. ADJUSTMENT METHODC-3000ZOOM2
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer ex­cept the white section. (Do not enter any light.)
2. Double-click on the DscCalDi125.
3. Click the “AWB”, and click the “Yes”.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
6. Color Matrix Adjustment
8. LCD Panel Adjustment
[CA2 board (Side A)]
CL413
CL414
CL417
Serial cable
Camera
Preparation:
POWER switch: ON
Adjustment method:
1. Set the color adjustment chart to the color viewer. (Do not enter any light.)
2. Set the color adjustment chart so that it becomes center of the screen.
3. Double-click on the DscCalDi125.
4. Click the “UV Matrix”, and Click the “Yes”.
5. Adjustment values will appear on the screen.
6. Click the OK.
15 cm ± 1 cm
All white pattern color
viewer (5,100K) and
color matrix adjustment chart
7. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi125.
2. Select CCD Defect Detection on the LCD “Type”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
8-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi125.
2. Select 0 on the LCD “H AFC”.
3. While watching the LCD monitor, adjust “H AFC” so that the edge of the LCD adjustment frame are the same dis­tance from the left and right edge of the LCD screen. (A = B)
LCD
LCD screen
A
FPC
adjustment
B
frame
8-2. LCD Gain Adjustment
Adjusting method:
1. Adjust LCD “Gain” so that the amplitude of the CL415 waveform is 1.0 Vp-p ± 0.1 V.
1.0V
±0.1Vp-p
CL415 waveform
C-13Ver.3 SERVER_DIS
Page 15
C. ADJUSTMENT METHOD C-3000ZOOM2
8-3. LCD RGB Offset Adjustment
Adjusting method:
1. Adjust LCD “RGB Offset” so that the amplitude of the
CL415 waveform is 5.1 Vp-p
Note:
8-2. LCD Gain adjustment should always be carried out first.
± 0.1 V.
5.1V
±0.1Vp-p
CL415 waveform
8-5. LCD Blue Brightness Adjustment
Adjusting method:
1. Adjust LCD “B Bright” so that the amplitude of the CL413
waveform is VG waveform.
Note:
8-2. LCD Gain adjustment and 8-3. LCD RGB Offset adjust­ment have done.
± 0.1 V with respect to the CL415 (VG)
VG
8-4. LCD Red Brightness Adjustment
Adjusting method:
1. Adjust LCD “R Bright” so that the amplitude of the CL414
waveform is VG waveform.
Note:
8-2. LCD Gain adjustment and 8-3. LCD RGB Offset adjust­ment should always be carried out first.
± 0.1 V with respect to the CL415 (VG)
VG
CL415 waveform
CL415 waveform
VG±
0.1Vp-p
CL413 waveform
8-6. LCD Tint Adjustment (for PAL)
Adjusting method:
1. Adjust “Tint” so that the amplitude of CL415 waveform
is minimum.
Note:
8-6. LCD TINT adjustment should always be carried out last.
a
CL414 waveform
VG±
0.1Vp-p
a
a
a
C-14 Ver.3SERVER_DIS
Page 16
C. ADJUSTMENT METHODC-3000ZOOM2
[ 7 ] Adjustment Values
Explanation of adjustment values
Adjustment values are values which have been estimated sta­tistically from the distribution of adjustment values obtained from similar machine models and prototypes. Accordingly these values should be used as a guide only. Because these values are guides, equipment which is in good working order may still produce values which are outside the adjustment value ranges, so that the equipment should be operated in order to determine whether it is in fact opera­tional or defective.
Range of adjustment values
(1) Lens adjustment ranges
(2) AWB adjustment ranges
[How to read a dialog of adjustment value] “WD=WD1,WD2,WD3”
[Adjustment value] WD1: 200 to 400 WD2: 128(fixed value) WD3: 200 to 400
[Adjustment value] STD_AFPOS : Within 15 and 120
Note :STD_AFPOS = “ 0 “ means NG.
(3) Color matrix adjustment ranges
[How to read a dialog of adjustment value] “UD=UD0,UD1,UD2,UD3” “UC=UC0,UC1,UC2,UC3”
[Adjustment value] UD0: 40 to 160 UD1: 180 to 256, 0 to 60 UD2: 180 to 256, 0 to 60 UD3: 40 to 160
Adjustment values are normal except following cases. It does not detect any signal from CCD. In this case, adjustment values are all “1”. UD0: 1 UD1: 1 UD2: 1 UD3: 1
C-15Ver.3 SERVER_DIS
Page 17
C. ADJUSTMENT METHOD C-3000ZOOM2
[8] Adjustment Items
Changed repair parts
Adjustment items
CCD 1 IC501 Oscillation Frequency Adjustment *1 2 5.1V(A) Voltage Adjustment *1 3 13.0V(L) Voltage Adjustment *1 4 Lens Adjustment 5 AWB Adjustment 6 Color Matrix Adjustmen 7 CCD Defect Detect Adjustment
{{{ { {{{ { {{{ { {{{ {
8-1 LCD H AFC Adjustment 8-2 LCD Gain Adjustment 8-3 LCD RGB Offset Adjustment 8-4 LCD Red Brightness Adjustment 8-5 LCD Blue Brightness Adjustment 8-6 LCD Tint Adjustment (For PAL)
*1)There is no need that you adjust the provided ST1when changing it without changing the parts of component level.
LENS CA1 ST1
{ { {
CA2
{ { { { { {
C-16 Ver.3SERVER_DIS
Page 18
CHECKING OF LENS UNIT
1. Check Item
1)Backlash Pulse of LD
2)LD ERROR Pulse
3)Basklash Pulse of ZOOM
4)ZOOM ERROR Pulse
2. Tools
Part No.
1
2
3
4
5
KC0331
KC0334
KC0338
FPC-Adaptor
FPC-Adaptor
C.ADJUSTMENT METHOD
Description
Lens Checker LCK1
Connector Cable P5
Clip Connector 17
12-PINS for K-FPC
14-PINS for S-FPC
Q’ty
1
1
2
1
1
FPC-Adaptor 12
PINS for K-FPC
FPC-Adaptor 14
PINS for S-FPC
The last 2 digits are mean-
ing the number of Pin.
080-10
3. Checking Prosedure
Fi x 2 FPC-Adaptors (12 and 14 PINS) to ClipConnector
17.
Connect Connector Cable P5, Clip Connector 17
and Lens Checker LCK-1
1) AUTO
I. Tum on Lens Checker LCK-1
Ex.) 080-12 :12PINS
Lens Checker LCK-1
Connector Cable P5
Initial Setting
II. Set AUTO / MANU SW at AUTO
III.Set Dial SW at 4
IV. Set CW / CCW SW at CW
LCK-1 Ver.1 0 Auto
PUSH START SW
(0 : Number of Dial SW 0-5)
V. Connect the both FPCs (K-FPC and S-FPC) to
Clip Connectors. Hold a lens unit by hand, and keep
it horizontally.
VI. Push START SW. (More than 0.2 sec.)
LCK-1 Ver.1 0 Auto
ZOOM RESET
Clip Connector 17
C-17Ver. 3/Rev.4
Page 19
C.ADJUSTMENT METHOD
When an error occurs, an error is indicated, and it stops.
LCK-1 Ver.1 0 Auto
LD RESET
LCK-1 Ver.1 0 Auto
LD BACKLASH CHK
LB*
* is BACKLASH PULSE of LD
LCK-1 Ver.1 0 Auto
LD D CHK
LB1 D *
* is LD ERROR PULSE
LCK-1 Ver.1 0 Auto
ZOOM BACKLASH CHK
LB1 D1 ZB *
* is BACKLASH PLUSE of ZOOM
In case of GOOD
LCK-1 Ver.1 0 Auto
PUSH START SW
LB1 D1 ZB1 D12
GOOD
In case of NG :
LCK-1 Ver.1 0 Auto
PUSH START SW
LB D6
NO GOOD ZM D Err
ERROR is indicated
(The indication which isn’t being explained is the condition
of PR and PI.)
When CW/CCW SW is set at CCW, the automatic check of
the motor chosen with a LD/ZOOM SW is done.
2) Manual
I. Set AUTO/MANU SW at MANU
LCK-1 Ver.1 0 Manu
LD CW
LCK-1 Ver.1 0 Auto
ZOOM D CHK
LB1 D1 ZB1 D * *
* * is ZOOM ERROR PULSE (ZOOM AREA : SET-UP AREA)
The contents chosen with the LD/ZOOM SW and the CW/
CCW SW indicated in LCD.
II. Push START SW (More than 0.2 sec.)
LCK- Ver.1 0 Manu
LD CW
MOVE
When a motor works, “MOVE” is indicated in LCD.
C-18 Ver.3/Rev.4
Page 20
C.ADJUSTMENT METHOD
LD Motor
When PI signal 500 pulses (500pps) are changed,LD motor
stops
CW : Turn Out CCW : Tum In
ZOOM Motor
When PI signal 2200 pulses (300pps) are changed, ZOOM
motor stops
CW : W to T CCW : T to W
4. Others
Turn off LCK-1 promptly if something is wrong.
5, ERROR Indication
PI, PR Err : PI or PR Pulse does not change.
LD BK Err : LD BACKLASH PULSE is out of standard.
LD D Err : LD Pulse Error
ZD BK Err : ZOOM BACKLASH PULSE is out of
standard
ZD D Err : ZOOM Pulse Error
C-19Ver. 3/Rev.4