SIEMENS STAR CHART .............................................................................................. C-9
CHECKING OF LENS UNIT ....................................................................................... C-17
SERVER_DIS
C-1-2
Ver.3/Rev.4
[1] Table for Servicing Tools
Ref. No.Name
J-1
J-2
J-3
J-4
J-5Extension cord
J-6
Note: J-1 color viewer is 100 - 110 VAC only.
Color viewer 5,100 K
Siemens star chart
Calibration software
Extension cord
Chart for color adjustment
Qt’y
1
1
1
1
1
1
J-1J-2
J-3
J-4/J-5
C. ADJUSTMENT METHOD
[2] Equipment
1. Oscilloscope
Part code
VJ8-0007
VJ8-0169
VJ8-0162
VJ8-0165
VJ8-0155
2. Digital voltmeter
3. AC adaptor
4. IBM R -compatible PC
5. DC regulated power supply
[3] Adjustment Items and Order
1. IC501 Oscillation Frequency Adjustment
2. 5.1 V (A) Voltage Adjustment
3. 13.0 V (L) Voltage Adjustment
4. Lens Adjustment
5. AWB Adjustment
6. Color matrix Adjustment
7. CCD Defect Detect Adjustment
8. LCD Panel Adjustment
8-1. LCD H AFC Adjustment
8-2. LCD Gain Adjustment
8-3. LCD RGB Offset Adjustment
8-4. LCD Red Brightness Adjustment
8-5. LCD Blue Brightness Adjustment
8-6. LCD Tint Adjustment (for PAL)
Note:
1. If the lens, CCD, board and changing the part in item 4-7
replace, it is necessary to adjust again. Item 5-7 adjust
ments should be carried out in sequence.
C-3030ZOOM/C-3000ZOOM
J-6
[4] Setup
1. System requirements
Windows 95 or 98
IBM R -compatible PC with 486 or higher processor
CD-ROM drive
3.5-inch high-density diskette drive
Serial port with standard RS-232C interface
8 MB RAM
Hard disk drive with at least 15 MB available
VGA or SVGA monitor with at least 256-color display
2. Installing calibration software
1. Insert the calibration software installation diskette into your
diskette drive.
2. Open Explorer.
3. Copy the DSC Cal folder on the floppy disk in the FD drive
to a folder on the hard disk.
C-2Ver.3SERVER_DIS
C-3030ZOOM/C-3000ZOOM
C. ADJUSTMENT METHOD
[5] Connecting the camera to the computer
1. Turn off both camera and computer.
2. Locate the port cover on the side of the camera. Press on the arrows and slide the cover down to open it.
3. Line up the arrow on the cable connector with the notch on the camera's serial port. Insert the connector.
4. Locate a serial port on the back of your computer. You may have two serial ports labeled COM1 and COM2, or the ports
may be labeled with icons. If you have two serial ports available, use port 1 to connect your camera.
5. Line up the serial connector on the cable with one of the serial ports on your computer, and insert the connector.
6. Turn on the camera and your computer system.
Serial cable
To COM1 serial port
AC adaptor
C-3Ver.3SERVER_DIS
[6] Adjust Specifications
[ST1 board (Side B)]
C. ADJUSTMENT METHOD
Adjustment method:
1.Adjust with VR504 to 13.00
4. Lens Adjustment
C-3030ZOOM/C-3000ZOOM
± 0.05 V.
VR501
CL524
(Side A)
VR504
VR502
CL522
CL501
(Side A)
Q5001
Collector
(Side A)
Note:
1. Voltage adjustment is necessary to repair in the ST1 board
and replace the parts.
2. Carry out adjustment with disconnect wires for storbe.
Preparation:
1. Connect the SY1 board (CN301) and the CA2 board
(CN106) with extension cord. (VJ8-0165)
2. Connect the ST1 board (CN501) and the CA2 board (CN104)
with extension cord. (VJ8-0162)
3. Connect LCD panel.
4. Insert the card.
5. Turn on the power switch, and then set the camera mode.
1. IC501 Oscillation Frequency Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR501 to 200 ± 1 kHz.
Q5001 Collector or CL501
Frequency counter
VR501
200 ± 1 kHz
Serial cable
Camera
150 cm ± 3 cm
Siemens
star chart
Preparation:
POWER switch: ON
Adjustment condition:
Siemens star chart (A3)
Fluorescent light illumination with no flicker (incandescent
light cannot be used.)
Illumination above the subject should be 400 lux
± 10%.
Adjustment method:
1. Set the siemens star chart 150 cm ± 3 cm so that it becomes center of the screen.
2. Double-click on the DscCalDi124.
3. Click the “Focus”, and Click the “Yes”.
4. Lens adjustment value will appear on the screen.
5. Click the OK.
5. AWB Adjustment
2. 5.1 V (A) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Adjust with VR502 to 5.10
CL524
Digital voltmeter
VR502
5.10
± 0.05 V
± 0.05 V.
3. 13.0 V (L) V oltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
CL522
Digital voltmeter
VR504
13.00
± 0.05 V
Serial cable
Camera
All white pattern
Color viewer (5,100K)
C-4Ver.3SERVER_DIS
C-3030ZOOM/C-3000ZOOM
Preparation:
POWER switch: ON
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi124.
3. Click the “AWB”, and click the “Yes”.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
C. ADJUSTMENT METHOD
6. Color Matrix Adjustment
8. LCD Panel Adjustment
[CA2 board (Side A)]
CL413
CL414
CL415
Serial cable
Camera
Preparation:
POWER switch: ON
Adjustment method:
1. Set the color adjustment chart to the color viewer.
(Do not enter any light.)
2. Set the color adjustment chart so that it becomes center of
the screen.
3. Double-click on the DscCalDi124.
4. Click the “UV Matrix”, and Click the “Yes”.
5. Adjustment values will appear on the screen.
6. Click the OK.
15 cm ± 1 cm
All white pattern color
viewer (5,100K) and
color matrix adjustment chart
7. CCD Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi124.
2. Select CCD Defect Detection on the LCD “Type”, and click
the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
8-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Card switch: ON
Adjusting method:
1. Double-click on the DscCalDi124.
2. Select 0 on the LCD “H AFC”.
3. While watching the LCD monitor, adjust ”H AFC” so that
the edge of the LCD adjustment frame are the same distance from the left and right edge of the LCD screen. (A = B)
LCD
LCD screen
A
FPC
adjustment
frame
B
8-2. LCD Gain Adjustment
Adjusting method:
1. Adjust LCD “Gain” so that the amplitude of the CL415 waveform is 1.0 Vp-p ± 0.1 V.
1.0V
±0.1Vp-p
CL415 waveform
C-5Ver.3SERVER_DIS
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.