When troubleshooting the receiver, first check the RX_AGC PDM value. The AGC value
should be close to the typical values in the tables. Since the RX AGC will try to keep a
constant amplitude at the output of the receiver chain, if the AGC value indicates an
AGC gain that is substantially higher than normal, then the AGC is compensating for
extra loss in another component. If the AGC PDM values are normal, but there is still a
problem, check the actual AGC voltages. RF probing at specific locations in the chain can
then help to pinpoint the source of the problem.
Likewise, when troubleshooting the transmitter, first check the measured output power
and AGC values, which will give an indication of where to start probing.
Although the tables list power levels for many combinations of AGC values, it is generally
only necessary to check one combination. The extra information is provided in case it
may be useful in an unexpected situation. Likewise, although probing points and signallevel information are given for each point in the receiver and transmitter chains, the
troubleshooter is not expected to probe each point on every phone — only the suspected
trouble spots.
Absolute power measurements were made with an Agilent (HP) 85024A active highimpedance probe. Other probes can be used (but should be high-impedance so that the
measurement does not load the circuit) but may very well have a different gain; therefore, adjust the absolute measurements accordingly. Also, adjust if using a probe attenuator.
Where a range is given for loss, typically the higher loss occurs at the band edges. Probing is not a very accurate method to measure absolute power; therefore, you cannot
expect measured results to exactly match the numbers listed here.
Power depends on the impedance of the circuit. For example, if a filter has a nominal loss
of 5 dB, then straightforward probing on the input and output, then subtracting, might
not result in 5 dB because the input impedance might be different from the output
impedance. Most components in the RF section have the same input and output impedance (50 ohms), but where this is not the case, absolute power is noted in the tables in
dBm, rather than loss or gain in dB.
When testing the CDMA receiver, it is easier to inject a CW tone into the receiver. The
gains and losses will be the same for a CW signal as for CDMA.
Note: After opening the shield lids, allways replace them with new lids.
Conditions of Phone
TX Power Low
If TX power is low, turn on transmitter in local mode using Phoenix. Check:
1Current (0.7 - 1 A for max power, mode, and channel dependent).
2Perform visual inspection of PWB under microscope to check proper placement,
rotation, and soldering of components.
3Look for presence of TX signal on spectrum analyser at the correct frequency. If
signal is not on frequency, check in 100 MHz span. If signal is present but offfrequency, check synthesizer. If signal is not present, or present but low in amplitude, use probing tables to determine where in the chain the fault occurs, with
AGC PDMs set for known transmit power as listed in the tables.
4Check that AGC PDMs are set for desired TX power and ensure AGC voltages are
correct.
5Check the LOs for proper frequency and amplitude.
6Ensure power supplies to transmitter have correct voltage.
Receiver Not Working Properly
If Receiver is not working properly, turn on receiver in local mode and check:
1Turn on receiver with Phoenix, inject a signal into the receiver.
2Check the AGC PDM.
3Perform a visual inspection of the PWB under a microscope to check proper
placement, rotation, and soldering of components.
4Measure signal levels at various points in the chain and determine where in the
chain the fault lies.
5Check the LOs for proper frequency and amplitude.
6Ensure power supplies to receiver have correct voltage.
Phone Cannot Make a Call
If phone won't make a call:
1Ensure phone is in normal mode (i.e., ensure the phone is searching for a signal,
net server is on).
2Ensure Preferred Roaming List (PRL) is loaded into phone.
3Ensure phone is tuned (read tuning parameters using Batch Tune component in
Phoenix, an untuned phone will have all zeros in tuning file), and has passed tuning.
4Ensure call box channel is set for a channel in PRL, and ensure SID is correct.
5Ensure MIN, MDN, and SID are entered into the phone.
6Ensure VCTCXO is centered, as described in VCTCXO tuning description.
7Ensure transmitter and receiver are working properly by checking them in local
mode.
Transmitter Troubleshooting
Cell Transmitter
Cell Transmitter Path
The following table indicates the test points to probe when troubleshooting the cell
transmitter path. The steps shown are the recommended but do not have to be followed
in that order. Refer to the Appendix for a reference diagram that illustrates the test
points on the circuit board. An HP high frequency probe is used to make the frequency
and output power measurements.
11Z802Pin 1Iso Out=Dup Inpin 11-Z803dBm/30kHzThis test point
is inaccessible
12Z803Pin 8Dup-Antpin 8-19dBm/30kHzThis point is
only accessible if the CELL
duplexer can
shield is
removed
13Z800Pin 3Diplexerleft-L802-19
Cell Power Amplifier
The table above is the path that one would take to determine where the problem is in the
transmitter path. There are other circuits that affect the operation of the transmitter
path; for example, the power amplifier (PA) has the DC/DC converter (PMIC device)
which controls it. The following tables illustrate the circuits that have an effect on the
transmitter path and how to troubleshoot them.
The following table illustrates the PA troubleshooting information.
The following table illustrates the PDM values and their typical values for the IF AGC, RF
AGC Jedi Pout, Gain steps, and the PA VCC levels. It also shows the typical power output
at the RF connector.
The following table indicates the test points to probe when troubleshooting the PCS
transmitter path. The steps shown are the recommended but do not have to be followed
in order. Refer to the Appendix for a reference diagram that illustrates the test points on
the circuit board. An HP high-frequency probe is used to make the frequency and output
power measurements.
the transmitter path. There are other circuits that affect the operation of the transmitter
path; for example, the power amplifier (PA) has the DC/DC converter (PMIC device) that
controls it. The following tables illustrate the circuits that have an affect on the transmitter path and how to troubleshoot them.
The table below illustrates the PA troubleshooting information.
PA Power and Gain Measurements
Power Amplifier Input
Test Point
right C640* left R803** right C804
* inaccessible unless shield can is removed (no lid)
** This is the coupled power. You must 30 dB to get correct value