NHK–1/3/4 SERVICE SOFTWARE INSTRUCTIONS Contents
Introduction Page 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Page 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Minimum Required Servicing Equipment Page 6. . . . . . . . . . . . . . . . .
Mechanical Connections Page 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Start Up Procedure Page 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction to Service Software Package User Interface Page 9. . . . .
Service Software/Hardware Enviroment Page 9. . . . . . . . . . . . . . . . .
Service Software Enviroment Page 9. . . . . . . . . . . . . . . . . . . . . . . . . .
Service Software Executables Page 10. . . . . . . . . . . . . . . . . . . . . . .
Command Line Parameters Page 10. . . . . . . . . . . . . . . . . . . . . . . . .
Common Properties of the User Interface Page 11. . . . . . . . . . . . . . . . . .
Login Dialog Page 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Main Window Page 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Bar Page 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Page 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure Page 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tuning Page 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing Page 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Software Page 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dealer Page 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
View Page 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone Identity Window Page 18. . . . . . . . . . . . . . . . . . . . . . . . . . .
Help Page 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mouse Cursors Page 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reserved Keys Page 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Short Cut Function Keys Page 19. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alt Hot Keys Page 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ctrl Hot Keys Page 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shift Hot Keys Page 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Key Strokes Page 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Help Functions Page 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dialog boxes Page 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Common Dialog boxes Page 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note Message Box Page 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Query Message Box Page 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error Message Box Page 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Custom Dialog boxes Page 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Buttons Page 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reporting Status Page 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Original 12/97
Page 3
Service Software Instructions
PAMS
NHK–1/3/4 Specific Features Page 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Bar Page 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Page 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
New command Page 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Open... command Page 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Close command Page 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initialize command Page 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Normal Mode Page 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local Mode Page 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Faultlog Page 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exit command Page 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure Page 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options... command Page 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Directories... command Page 29. . . . . . . . . . . . . . . . . . . . . . . . . . .
Faultlog... command Page 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tuning Page 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AFC... command (NHK–4) Page 32. . . . . . . . . . . . . . . . . . . . . . . .
RSSI (AGC)... command (NHK–4) Page 34. . . . . . . . . . . . . . . . .
RSSI (AGC)... command (NHK–1) Page 36. . . . . . . . . . . . . . . . .
TX Power... command Page 38. . . . . . . . . . . . . . . . . . . . . . . . . . . .
TX I/Q... command Page 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery A/D... command Page 43. . . . . . . . . . . . . . . . . . . . . . . . . .
Charger A/D... command Page 44. . . . . . . . . . . . . . . . . . . . . . . . .
Testing Page 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Testing (RF)... command (NHK–4) Page 45. . . . . . . . . . . .
Self Tests... command Page 50. . . . . . . . . . . . . . . . . . . . . . . . . . . .
MCU Powerup Self–tests Page 51. . . . . . . . . . . . . . . . . . . . . . . . .
MCU Self Tests Page 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADC Readings... command (NHK–4) Page 55. . . . . . . . . . . . . . .
Audio... command Page 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display... command Page 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Call Simulation.. command Page 59. . . . . . . . . . . . . . . . . . . . . . . .
Noise Sensitivity... command Page 60. . . . . . . . . . . . . . . . . . . . . .
Software Page 62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone Identity... command Page 62. . . . . . . . . . . . . . . . . . . . . . . .
Serial Number Transfer... command Page 63. . . . . . . . . . . . . . . .
Product Profile... command (NHK–4) Page 64. . . . . . . . . . . . . . .
Start Up Self–tests... command Page 65. . . . . . . . . . . . . . . . . . . .
Set Default Values... command Page 66. . . . . . . . . . . . . . . . . . . .
Dealer Page 67. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Short Code Memory... command Page 67. . . . . . . . . . . . . . . . . . .
User Settings... command Page 69. . . . . . . . . . . . . . . . . . . . . . . . .
Set UI Default Values... command Page 70. . . . . . . . . . . . . . . . . .
View Page 71. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Documentation
Page 4
Original 12/97
PAMS
Technical Documentation
Quick/RF Info... command (NHK–4) Page 71. . . . . . . . . . . . . . . .
Phone Identity... command Page 71. . . . . . . . . . . . . . . . . . . . . . . .
Help Page 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index command Page 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General help command Page 72. . . . . . . . . . . . . . . . . . . . . . . . . . .
Using Help command Page 72. . . . . . . . . . . . . . . . . . . . . . . . . . . .
About... command Page 72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initialization File Page 73. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix 1, Vocabulary Page 74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Software
Original 12/97
Page 5
Service Software Instructions
PAMS

Introduction

General

The NHK–1/3/4 Service Software is specially designed to facilitate the servicing of PCN cellular telephones.
The software can be used to control the phone according to the user’s require­ments merely by entering commands via the keyboard or mouse of a PC con­nected to the phone.
This section refers to the Service Software Version 2.3. NMP After Sales will notify service personnel about future upgrades via Technical Bulletins. Software upgrades will be available from your local NMP outlet.

Minimum Required Servicing Equipment

– Computer: Intel 386/33 MHz or compatible with one unused serial port
(COM1 or COM2*), one parallel port (LPT1), hard disk recommended.
Technical Documentation
– Memory: 4 MB or more – Operating System: DOS Version 5 or later & Microsoft Windows 3.11 – Display: VGA based display (640 x 480) – WinTesla Service Software: SWSA1 for 3.5” disk (product code: 0774046) – Software Protection Key PKD–1 (product code 0750018) – M2BUS interface cable DAU–2 (product code 0750006) – RS–232 adapter, 9 to 25 pins (product code 4626170) – Service cable SCS–1 (product code 0770010)
Page 6
*)
Note: A number of PC’s of an older generation use the Intel, National Semiconductor, or
United Microelectronics IC 8250 as the serial port UART. This is a comparatively inefficient circuit for current purposes and does not necessarily support the M2BUS adapter at 9600 baud. The newer UART’s NS16450 and NS16550AF of National Semiconductor offer solutions for these problems.
Original 12/97
PAMS
Technical Documentation

Mechanical Connections

Caution: Ensure that you have switched off the PC and the printer before
making connections !
Caution: Do not connect the PKD–1 to the serial port. This could damage
the PKD–1 !
The software controls the phone via a separate adapter connected to the serial port of the PC and to the telephone’s M2BUS (DAU–2 and SCS–1).
Attach the protection key PKD–1 to parallel port one (25–pin female D–connec­tor) of the PC. When connecting the PKD–1 to the parallel port be sure that you insert the PC end of the PKD–1 to the PC (male side). If you use a printer on parallel port one, place the PKD–1 between the PC and your printer cable.
The PKD–1 should not effect devices working with it. If some errors occur (er­rors in printing are possible) please try printing without the PKD–1. If printing is OK without the PKD–1 please contact your dealer. We will offer you a new PKD–1 in exchange for your old one.
Service Software
Original 12/97
Page 7
Service Software Instructions
PAMS
Technical Documentation
Attach first the RS–232 adapter cable to the PC’s 9–pin serial port. Connect the M2BUS adapter (DAU–2) to the RS–232 cable. Connect the service cable SCS–1 to the M2BUS adapter (DAU–2) and attach the other end of the cable to the bottom connector of the phone.

Start Up Procedure

Start the phone by pressing the power–on button of the handset. Switch PC power on.
To installing software, proceed as follows:
1. Insert Service Software disk into drive A of your PC
2. Start Windows: type
3. Start Installing program: select
4. Follow Installation Software instructions
WIN
and press
File –> Run
menu, then type press OK button
Enter
from Program Manager
A:INSTALL
and
Page 8
Original 12/97
PAMS
Technical Documentation
Service Software

Introduction to Service Software Package User Interface

This chapter gives a short description of the Service Software properties.

Service Software/Hardware Enviroment

To run the Service Software, a parallel port software protection device (PKD–1) has to be connected. The user can use the Service Software functions for test­ing all supported Phone Types. The functions send messages from the PC to the phone, receive results and show them on the PC display. The messages are sent via a low level NMP proprietary bus protocol. An example bus is an M2BUS interface, which needs M2BUS adapter (DAU–2) connected to the PC RS–232 port and special M2BUS cable.
The recommended minimum hardware standard to run the Service Software package is any computer which is 386 33Mhz or greater with at least 4 MB of memory and VGA type display (640x480). This assumes that only the Service Software package is active, i.e. other Windows packages are not running in the background.
Note: if the Service Software is to be run on a laptop, the power saving feature MUST be switched off.

Service Software Enviroment

Service Software user interface is intended for Microsoft Windows 3.11 environ­ment running in enhanced mode. For those who are familiar with Windows en­vironment this application will be easy to use. Detailed information about Win­dows and application usage can be found from Ref 3– Microsoft Windows Version 3.11 Users Guide chapter one (Windows Basics) and chapter two (Ap­plication Basics).
As an ordinary Windows application, the main idea in the user interface is that selections are made with menus, push buttons and shortcut keys. Selections can be done by using keyboard and/or mouse. When messages from phone
Original 12/97
Page 9
Service Software Instructions
PAMS
are received, they cause display updating in special display windows. There is always a status bar displayed at the bottom of the main window which contains information about current actions.
Service Software Executables
Only one executable is needed – WinTesla. For NHK–1/3/4 there are two DLL’s: – Functionality DLL is NH134.DLL – User Interface DLL is NH134EN.DLL
Command Line Parameters
There are NO command line parameters.
Technical Documentation
Page 10
Original 12/97
PAMS
Technical Documentation

Common Properties of the User Interface

This chapter describes how the User Interface CLF must appear to the user. The User Interface MUST be capable of being driven without the use of a
mouse, as the service engineer rarely has space on the bench to use a mouse.

Login Dialog

When the Service Software application is invoked, by checking on the Service Software icon, the Login dialog box will be displayed on the screen.
Nokia logo and application name
Service Software
Nokia logo and application name bitmap (–)
Displays Nokia logo and name of the application.
Application version static text (–)
Contains the name and version of the application.
Copyright notice static text (–)
Copyright is informed as: “Nokia Mobile Phones (c) 1996. All Rights Reserved”.
Application version
Copyright version
Login box
Login Box edit box (–)
OK button (default key)
Original 12/97
The user Login ID edit box, where the user enters his faultlog user name. (See Faultlog User Guide)
Page 11
Service Software Instructions
PAMS
Cancel button (ESC)
Help button (F1)

Main Window

The application supports a service software interface will present a pearance.
Note: MDI is to allow for future expansion, e.g. R&D features.
Technical Documentation
The user name is stored in memory and the dialog box is closed. When the dialog box is closed, the application starts.
The Dialog box is closed and application is started, but the Faultlog feature is disabled.
Activates the Windows Help application and displays context sensi­tive Help.
Multiple Document Interface (MDI).
Single Document Interface (SDI)
However, the
ap-
Title bar
The
title bar
A title bar contains the following elements:
Application Control–menu button
Maximise button
Minimise button
Name of the application
Restore button
The properties of these elements and their usage is described in Ref 3– Micro­soft Windows Version 3.11 Users Guide chapter one (Windows Basics) and chapter two (Application Basics).
Menu bar
menu bar
The The menu bar is a dynamic element and is dependent on the dongle type fitted, and whether a phone is connected.
is located at the top of the window.
is below the title bar and contains all available menu selections.
Page 12
Original 12/97
PAMS
Technical Documentation
Underlined characters in menu names and options indicates that the menu selection can be done by pressing be selected by activating menu bar with row–keys to highlight the desired menu. In that case, selection is done by pressing
Menus can also be selected by using the mouse as described in Ref 3–Micro­soft Windows Version 3.11 Users Guide
Status bar
The The status bar contains information about the menu selections and events.
The left area of the status bar describes the actions of menu items as the user uses the arrow keys to navigate through menus.
The status bar texts are explained in detailed in each of command’s descrip­tion.
The right areas of the status bar indicate which of the following keys are latched down:
Indicator Description
Enter
status bar
Service Software
Alt+ underlined character
Alt
– key ( or
.
is displayed at the bottom of the Service Software main window.
F10
. Options can also
key ) and using ar-
USER Entered Login ID. CAP The Caps Lock key is latched down. NUM The Num Lock key is latched down. SCRL The Scroll Lock key is latched down.
Tool bar
The
tool bar
document.
is NOT defined and will not be implemented until specified by this
Original 12/97
Page 13
Service Software Instructions
PAMS

Menu Bar

The Service Software package will have two menu bar configurations. The first, is an abbreviated version that contains the minimum number of menus that al­lows package configurations when a phone is NOT connected. The second is described below:
The menu bar contains the following menus for the Service Software package when a phone is connected:
P
C
T
Te
S
D
V
H
Technical Documentation
roduct* onfigure*
uning
sting oftware ealer iew elp*
Product
* – always displayed, even if no phone is connected. A menu is broken down into sections that are indicated with menu separators.
Each sections identifies a logical difference from itself and other sections, i.e. between transmitter and receiver. Any items that are required to be added to a menu lists will be added on the bottom of the appropriate menu section list. If a new item is to be added which is common to two or more phone types, then that menu item will become a common menu item.
The menu lists will use the Microsoft [...] symbol after an item name to indicate that selecting that item will NOT initiate an operation immediately, i.e. a dialog box will be displayed for the user to select options or type in data and press the OK button before the operation is performed.
The Product menu contains the following menu items:
N
ew Ctrl+R
O
pen...
lose
C
I
nitialize
Normal Mode F5
Local Mode Shift+F5
aultlog
F
Activate Faultlog... F9
Edit Faultlog...
Page 14
Ex
it Alt+F4
Original 12/97
PAMS
Technical Documentation
Configure
The Configure menu contains the following menu items:
O
ptions...
D
irectories...
F
aultlog...
Phone Type Specific configuration items (where applicable)
Tuning
The Tuning menu contains the following menu sections:
Receiver
Transmitter
Voltages
Phone Type Specific tuning items (where applicable)
An example T
AFC...
Service Software
uning menu is shown below:
Testing
R
SSI (AGC)...
Tx
Power...
Tx I/Q
B
Charger A/D...
Additional menu items may be added within the sections according to the phone type being tuned, e.g. a Charger tuning menu item will be added after the Battery tuning item, but not in the Transmitter tuning section.
The Testing menu contains the following menu sections:
Quick Tests
Digital
User Interface Flexi
Transmitter
Receiver
...
attery A/D
Automatic Tests
Phone Type Specific testing items (where applicable)
Original 12/97
Page 15
Service Software Instructions
PAMS
Technical Documentation
An example Te
Q
uick Testing (RF)...
S
elf Tests
A
DC Readings
Au
dio
D
isplay
C
all Simulation...
N
oise Sensitivity...
Additional menu items may be added within the sections according to the phone type being tested.
Where a menu item consists of more than one test, a pop–up menu may be added to identify the appropriate sub–tests, e.g. there may be two receiver tests required for a particular phone type (Bit Error Rate and RSSI Monitoring). These will be shown as a popup from the Receiver menu item.
sting menu is shown below:
Software
The Software menu contains the following menu sections:
Phone Identity/Numbers
Flashing
Phone Type Specific software items (where applicable)
An example S
roduct Profile...
P
S
tart Up Self–tests...
Set Default V
oftware menu is shown below:
alues
Page 16
Original 12/97
PAMS
Technical Documentation
Dealer
The Dealer menu contains the following menu sections:
Phone UI Data Editors
Phone UI Data Transfer
Phone Re–Initialization Functions
Subscriber Data
Phone Type Specific dealer items (where applicable)
An example D
Short C
U
ser Settings
Set UI/DEV Default V
ode Memory
View
Service Software
ealer menu is shown below:
alues ...
The View menu contains the following sections:
Service Windows
Production Windows (where applicable)
R&D Windows (where applicable)
An example V
Q
uick/RF Info...
P
hone Information...
iew menu is shown below:
Original 12/97
Page 17
Service Software Instructions
PAMS
hone Information Window
P
The Phone Identity window should contain, as a minimum, the following data:
Software Version(s)
Hardware Version(s)
Serial Number(s)
Product Code
This window will only be used as a display window and therefore will not allow editing of the displayed data. This window will not contain any controls other than a scroll bar.
Help
The Help menu contains the following menu items:
I
ndex
Technical Documentation
G
eneral Help
U
sing Help
A
bout WinTesla
Page 18
Original 12/97
PAMS
Technical Documentation

Mouse Cursors

The standards Windows pointer will be used as the mouse cursor. During time consuming tasks e.g. communication to phone, an hour glass will
be shown informing the user that a task is in progress. The application uses the hour glass cursor to inform user that the application has taken the control and any actions from user will be ignored.
When a function is initiated, the hour glass will be displayed and when the func­tion has finished the mouse pointer will return to normal.

Reserved Keys

The following Hot keys and Short Cut keys are reserved either as Microsoft standard keys or as part of the Common Look and Feel specified by this docu­ment.
Short Cut Function Keys
Service Software
Key Description Defined by F1 Context Sensitive Help Microsoft
F5 Normal Mode NMP Shift+F5 Local Mode NMP F9 Activate Faultlog NMP F10 Goto Menu Bar Microsoft Ctrl+F4 Close Active Window Microsoft
Alt Hot Keys
Key Description Defined by Alt+F4 Exit Active Application Microsoft
Alt+H Help Microsoft
Ctrl Hot Keys
Key Description Defined by Ctrl+N File – New Microsoft
Ctrl+O F Ctrl+P F Ctrl+R P
Original 12/97
ile – Open Microsoft ile – Print Microsoft roduct – New NMP
Page 19
Service Software Instructions
PAMS
Shift Hot Keys
Key Description Defined by Shift+F5 Local Mode NMP
Key Strokes
Key Description Defined by Alt+P Product Menu NMP
Alt+P,N N Alt+P,O O Alt+P,C C Alt+P,I I Alt+P,I,N N Alt+P,I,L L
Technical Documentation
ew NMP
pen NMP
lose NMP
nitialize Pop–up NMP
ormal Mode NMP
ocal Mode NMP Alt+P,F F Alt+P,F,A A Alt+P,F,E E Alt+P,E E Alt+C C Alt+C,O O Alt+C,D D Alt+C,F F Alt+T T Alt+T,A A Alt+T,R R Alt+T,X Tx Alt+T,Q Tx I/Q Alt+T,B B Alt+T,C C
aultlog Pop–up NMP ctivate Faultlog NMP dit Faultlog NMP xit Application NMP
onfigure NMP
ption NMP
irectories NMP
aultlog NMP
uning Menu NMP
FC NMP
SSI(AGC) NMP
Power NMP
attery NMP
harger NMP
NMP
Page 20
Alt+E Te Alt+E,Q Q Alt+E,S S Alt+E,A A Alt+E,U Au
sting Menu NMP
uick Testing RF NMP elf Tests NMP DC Readings NMP
dio NMP
Original 12/97
PAMS
Technical Documentation
Alt+E,D D Alt+E,C C Alt+E,N N Alt+S S Alt+S,P P Alt+S,S S Alt+S,V Set Default V Alt+D D Alt+D,C Short C Alt+D,U U Alt+D,V Set UI Default V Alt+V V Alt+V,Q Q Alt+V,P P
Service Software
isplay NMP all Simulation NMP
oise Sensitivity NMP oftware Menu NMP roduct Profile NMP tart–Up Self Tests NMP
alues NMP
ealer Menu NMP
ode Memory NMP
ser Settings NMP
alues NMP
iew Menu NMP
uick/RF Info NMP
hone Information NMP
Alt+H H Alt+H,I I Alt+H,G G Alt+H,U U Alt+H,A A

Help Functions

The Help User Interface will be the standard Windows help tool called WinHelp. The context sensitive help is activated with F1–key. Help contains also Using
Help which describes how to use help facility. Refer to the Windows manual for detailed description on the Windows Help.

Dialog boxes

The Service Software application uses many different dialog boxes. Dialog boxes are used to display data and prompt the user for input.
Dialog boxes are opened from menus or with shortcut keys. Dialog boxes have different properties but some features are common.
elp Menu Microsoft
ndex Microsoft
eneral Help Microsoft
sing Help Microsoft bout WinTesla Microsoft
All service dialog boxes must be modal, that is, the user will not be able to start another operation without first closing the present dialog box.
All dialog boxes will contain the following entities: – Help button – Title bar
Original 12/97
Page 21
Service Software Instructions
PAMS
– At least one button other than Help – Application Control–menu Button
Common Dialog boxes
This sections describes the common dialog boxes used in the Service Soft­ware package, and the context in which they will be used.
Note Message Box
When the user has made an illegal selection, a opened and message text is displayed. The message box is also opened when the program has some information for the user. The size of the dialog box may vary. An information dialog box is recognized by the !–icon.
The dialog box will also contain an OK button and a Help button. OK button (default key):
Technical Documentation
note message box
dialog will be
Help button (Alt+H):
Query Message Box
Confirmations and questions are asked in box is recognized by the ?–icon.
The dialog box will also contain a Yes button, a No button, and a Help button.
Yes button (Alt+Y or Y) (default key):
No button (Alt+N or N):
Help button (Alt+H):
Acknowledge displayed information and continue. The dialog box is closed after selection.
Opens context sensitive help as F1–key does.
a query message box
Accepts confirmation or question.
Denies confirmation or question.
. A query dialog
Page 22
Opens context sensitive help as F1–key does.
The buttons may also be OK and Cancel. The operation of these buttons are the same as in the Note dialog box.
Original 12/97
PAMS
Technical Documentation
Error Message Box
Error message dialog boxes use the Stop–icon. When a “Stop”–dialog box is shown, the current operation is terminated.
The dialog box has a description about the failed operation and reason. Press­ing F1 (Help) application opens the appropriate help topic that gives information about recommended actions.
The dialog box will also contain an OK button and a Help button. OK button (default key):
Acknowledges displayed information and terminate current opera­tion. The dialog box is closed after selection.
Help button (Alt+H):
Open context sensitive help as F1–key does.
Service Software
Original 12/97
Page 23
Service Software Instructions
PAMS
Custom Dialog boxes
All custom dialog boxes will contain the predefined buttons as defined below in the section – tional button types, but the addition of these non–standard buttons should be carefully considered to minimise any inconsistencies between implementations.
The buttons will be positioned down the right–hand side of the dialog boxes. The default action will be OK, except where that default action could result in an irretrievable failure.
All tuning dialogs that contain tuning results, will display the old tuned data read from the phone before the tuning was performed, as well as the newly tuned data.
List boxes will be used to display lists of data, such as tuning data, test results etc.
The use of Radio buttons should be limited and carefully considered. The use of radio buttons defines the number of possible choices available to the user, which may be acceptable for one project, but not for another.
Buttons.
Technical Documentation
However, it is recognised that features may require addi-

Buttons

All buttons must be the Microsoft style of buttons. In general, the default button will be the OK button, the Close button or the Yes
button, but this will depend on the context of the dialog box that the button is associated with.
OK button:
Accepts and validates entered settings and values and closes the dialog. If the values have not been changed, then no action will be taken. The status bar will reflect the status. The user should only be queried, if the settings or values accepted will over–write data that CAN NOT be reproduced.
A greyed OK button indicates that settings selected by the user are not acceptable.
Close button:
Closes the current dialog box. Does not send or store anything and closes the dialog. The Close button is only used for dialogs that do not set or change any data.
Cancel button (Esc):
Page 24
Cancel operation. Does not send or store anything and closes the dialog box.
A greyed Cancel button indicates that it is not possible to quit from this dialog box.
Original 12/97
PAMS
Technical Documentation
Yes button (ALT+Y or Y):
Replies Yes to a question asked of the user.
No button (ALT+N or N):
Replies No to a question asked of the user.
Help button (ALT+H):
Opens context sensitive help as F1–key does.

Reporting Status

The status bar will be used to report the present status to the user. When a fea­ture is initiated, the status bar will be updated with a brief description of the function. The status bar will also be updated at key points in a time consuming function.
If an error is to be reported to the user, it will be displayed in the status bar as well as displayed in a common error dialog box. This will mean the user is not delayed from progressing on to the next operation unless an error occurs, in which case, the user will have to acknowledge the error by pressing the OK button.
Service Software
Original 12/97
Page 25
Service Software Instructions
PAMS
NHK–1/3/4 Specific Features

Menu Bar

The Service Software’s menus adopts the menu structure specified by CLF.
Product
New command
Activation Status Bar Text Alt, P, N Rescan a new phone
Ctrl+R This command scans a new product. When phone is found a product specific
functionality module is loaded. If no phone or wrong phone/cellular type is de­tected, functionality is unloaded and user is informed.
Technical Documentation
This function is also started automatically when the application is started. The user can also specify a regular poll which enables the WinTesla application to scan the new phone periodically. If the phone is still the same, no changes are done. If the phone is changed (with same phone type only the serial number is changed), the phone will be initialized to a normal mode. If the phone is changed to a different phone type, the current dlls are unloaded and new ones are loaded for that phone.
The initialization routine checks the phone’s cellular type (GSM/PCN), and if an unsupported phone is detected, the WinTesla application does not load the dlls.
If quick info view is open, the window will be automatically updated. If phone identification view is open, the window will be automatically updated.
pen... command
O
Activation Status Bar Text Alt, P, O Force load phone specific functionality
Enables the user to force load specific phone’s WinTesla dll’s. It also disables further phone type detection with New command.
Page 26
Note: This selection is for applications that has reflashing functionality. Reflash­ing is not implemented for NH–1 phones.
Original 12/97
PAMS
Technical Documentation
C
lose command
Activation Status Bar Text Alt, P, C Close loaded functionality
Closes loaded functionality and sends reset to phone if dlls are loaded by Open command.
Initialize command
Activation Status Bar Text Alt, P, I
Opens a submenu which contains the following options:
Normal Mode
Activation Status Bar Text
Service Software
Alt, P, I, N Initializes phone to normal mode F5
When normal mode has been activated or program has been started, self–test results will be asked from MCU. If any fault was found in the tests, an error message is shown. If normal mode has been set successfully (no self test error has been found), and paging listening has been started, the used AFC value is requested from MS.
The Initialization routine checks the phone’s cellular type (GSM/PCN) and if an unsupported phone is detected, the application unloads the dlls.
If phone identification view is open, the window will be automatically updated. Also if RF Information Window is open it will be updated to quick info view.
ocal Mode
L
Activation Status Bar Text Alt, P, I, L Initialises phone to local mode
Shift+F5 Selection will change the MS state to
phone is controlled to the local mode so that special actions can be made (for example RF tunings).
local
. When local mode is selected the
aultlog
F
Activation Status Bar Text Alt, P, F
Original 12/97
Page 27
Service Software Instructions
PAMS
it command
Ex
Opens a submenu which contains following options:
ctivate Faultlog...
A
Activation Status Bar Text Alt, P, F, A Activates faultlogging
F9
dit Faultlog...
E
Activation Status Bar Text Alt, P, F, E Activates faultlog editing
Activation Status Bar Text Alt, P, X Exit application
Alt + F4
Technical Documentation
Double click the application’s Control menu button:
This command ends the Service Software session.
Page 28
Original 12/97
PAMS
Technical Documentation
Configure
Options... command
Activation Status Bar Text Alt, C, O Edit Service Software configuration options
Service Software
The Options dialog box contains the following items:
O
K button (Alt+O):
Cancel button (Esc):
irectories... command
D
Activation Status Bar Text Alt, C, D Edit directory settings
Language drop down list. User ID edit box. M2BUS Com Port drop down list. Automatic Rescan edit box. Units in seconds (eg. value10 checks
the phone every 10 seconds in case it has been replaced).
The dialog box is closed, and
The dialog box is closed and changes
values are saved
are not saved
to phone.
to phone.
Original 12/97
Page 29
Service Software Instructions
PAMS
Technical Documentation
The Directories dialog box contains the following items:
ID D
ata edit box:
L
ogs edit box:
F
ault log file(s) edit box:
Data V Flash I B
O
K button (Alt+O):
The dialog box is closed, and
Cancel button (Esc):
The dialog box is closed and changes
alidation file(s) edit box:
mages edit box:
low failures edit box:
values are saved
are not saved
to phone.
to phone.
Page 30
Original 12/97
PAMS
Technical Documentation
F
aultlog... command
Activation Status Bar Text Alt, C, F Edit faultlog settings
The Faultlog dialog box contains the following items:
Service Software
Fault log enabled/disabled: A
utomatic fault log prompting enabled/disabled:
Allow M Country of R S
tation identity edit box:
P
roduct Code edit box:
W
arranty period months edit box:
Maximum T
anual Entry enabled/disabled:
epair edit box:
ime to repair edit box:
Original 12/97
Page 31
Service Software Instructions
PAMS
Tuning
The tuning menu offers functions for ME adjustments.
FC... command (NHK–4)
A
Activation Status Bar Text Alt, T, A Open an AFC diagram dialog box
Starts AFC tuning. The following are automatically selected when this tuning function is activated:
Active Unit = RX Operation mode = Continuous Update RF Information window
Before tuning is started, the user is requested to set the signal generator to the specified input level (read from .INI file). (Sample screen)
Technical Documentation
The AFC Diagram dialog box will open when the user accepts request:
The AFC Diagram dialog box contains the following items:
R
epeat button (Alt+R):
The measurement can be started again by pressing Repeat button.
O
K button (Alt+O):
The dialog box is closed, and tuning
is saved
to phone.
Page 32
Original 12/97
PAMS
Technical Documentation
Cancel button (Esc):
Dialog is closed and tuning
The D/A converter range (DAC) is from +1023 to –1024 and voltage range is from 0.25 V to 4.45 V (voltage precision is 0.01 V).
The frequency error range is from –134 kHz to +134 kHz with the precision 0.1 kHz. The rounding is made to the closest value.
After exiting with the Cancel button, the following are reset to the values which were selected before this adjustment.
Active Unit Operation mode Update RF Information window
The AFC is also reset to its previous value after exiting with the Cancel button.
is not saved
Service Software
to phone.
Original 12/97
Page 33
Service Software Instructions
PAMS
SSI (AGC)... command (NHK–4)
R
Activation Status Bar Text Alt, T, R Open RSSI Calibration dialog box
Starts RSSI calibration. The following are automatically selected when this tuning function is activated:
Active Unit = RX Operation Mode = Continuous Update RF Information window
The measurement is started automatically when RSSI calibration is entered. The measurement is done in five steps:
1. The user is requested to set signal generator to low input level (read from .INI file). (Sample screen)
Technical Documentation
2. Measurement with low input level is executed.
3. The user is requested to set signal generator to high input level (read from .INI file). (Sample screen)
4. Measurement with high input level is executed.
Page 34
Original 12/97
PAMS
Technical Documentation
5. The RSSI Calibration dialog box will be updated when previous steps are done. (Sample screen)
Service Software
The RSSI Calibration dialog box contains the following items:
AGC List box :
Gain code DAC can have values from 0 to 1023 and voltage from
0.25 V to 4.45 V (voltage precision is 0.01 V). Note that the needed input signal level is also shown.
The difference column shows the difference between tuned DAC val­ues and mean straight line calculated from part slopes in dBs (see /1/). This can be calculated when all measurement results have been received from phone.
R
epeat button (Alt+R):
The measurement can be started again by pressing this button.
O
K button (Alt+O):
The dialog box is closed, and tuning
Cancel button (Esc):
The dialog box is closed and tuning
is saved
to phone.
is not saved
to phone.
Original 12/97
Page 35
Service Software Instructions
PAMS
(Sample screen)When calibration is ended, the DAC value check is made, and if it is unsuccessful, an error message is shown. The test checks if all DAC val­ues are in the same order as AGC values in the table.
After exiting with the Cancel button, the following are reset to the values which were selected before this adjustment.
Active Unit Operation Mode Update RF Information window
The exit and the use of AGC–control values is done the same way as exit from power level tuning and power coefficient use.
SSI (AGC)... command (NHK–1)
R
Activation Status Bar Text
Technical Documentation
Alt, T, R Open RSSI Calibration dialog box Starts RSSI calibration. The following are automatically selected when this tuning function is activated:
Active Unit = RX Operation Mode = Continuous Update RF Information window
The measurement is started automatically when RSSI calibration is entered. The measurement is done in three steps:
1. The user is requested to set signal generator to low input level (read from .INI file). (Sample screen)
Page 36
2. Measurement with low input level is executed.
3. The RSSI Calibration dialog box will be updated when previous steps are done. (Sample screen, next page)
Original 12/97
PAMS
Technical Documentation
Service Software
The RSSI Calibration dialog box contains the following items:
RSSI Offset value:
RSSI offset value has the 0.1 dB precision.
A
GC List box (Alt+A):
AGC list box shows gain code values and correspondence com­pensation term values. AGC compensation terms have the 0.1 dB precision.
epeat button (Alt+R):
R
The measurement can be started again by pressing this button.
O
K button (Alt+O):
The dialog box is closed, and tuning
Cancel button (Esc):
The dialog box is closed and tuning
After exiting with the Cancel button, the following are reset to the values which were selected before this adjustment.
Active Unit
is saved
to phone.
is not saved
to phone.
The exit and the use of AGC–control values is done the same way as exit from power level tuning and power coefficient use.
Original 12/97
Operation Mode Update RF Information window
Page 37
Service Software Instructions
PAMS
Power... command
TX
Activation Status Bar Text Alt, T, X Open TX Power Tuning dialog box
Starts TX power tuning.
The user is first requested to select with which values tuning is started in the Start Tuning dialog box.
Technical Documentation
The Start Tuning dialog box contains the following items:
Start Tuning With list box (Alt+S): Current Values in PC memory
Tuning values are loaded from the program’s internal memory.
EEPROM Values
Tuning values are loaded from ME’s EEPROM.
The following are automatically selected when this tuning function is activated:
– Active Unit = TX – the BASE power level is selected – Operation mode = Burst
Page 38
Original 12/97
PAMS
Technical Documentation
The TX Power Tuning dialog box will be activated automatically after value selection.
NHK–4 dialog box: (Sample screen)
Service Software
NHK–1 dialog box: (Sample screen)
The TX Power Tuning dialog box contains the following items:
P
ower Level & Coefficients list box (Alt+P):
Original 12/97
The power is presented in PCN values (0...10). The base power is selected automatically when the dialog box is opened. The test value is reset to 0.035 when the program is started. The test value is not saved to the EEPROM. The test value can be changed during tuning
Page 39
Service Software Instructions
PAMS
as other power coefficients and the program remembers its value when tuning function is activated later again.
If there are more power levels in the phone than can fit into the win­dow, the window is scrollable. When the phone is initialized, the pro­gram asks the number of power levels used in the phone.
Only three power coefficients (biggest, third smallest and smallest) are needed to tune and the rest of them are calculated.
The tuning position is highlighted and can be tuned with +/– keys or left/right cursor keys.
alculate button (Alt+C):
C
The calculation is activated with this button. The power coefficients which are calculated from the tuned coefficients are displayed on the different columns than the others. All values can be tuned if needed.
+/– buttons (+/–):
The + and – buttons will cause power changing by 0.25dB steps. When these keys are used, the coefficient value is updated on the tuning window.
Technical Documentation
OK button (Enter):
The dialog box is closed, and tuning
Cancel button (Esc):
The dialog box is closed, and tuning
When selections are used, the power value checking is made and if it is unsuc­cessful, an error message is shown. The test checks that all power coefficients are in descending order (same order as power levels).
If the power tuning function is ended and EEPROM values are not received or EEPROM fault is noticed, an error message is shown.
When all power coefficients have such values that they don’t cause any error messages, the dialog box will close. The last selected tuning power will be used after exit.
Because the stored power level range is larger than the number of used power levels, the unused levels should be set to nearest possible power level. In the same way PCN levels after 10 are set to same value than level 10.
When this tuning function is ended, the following is automatically selected:
Active Unit = RX
is saved
is not saved
to phone.
to phone.
Page 40
Original 12/97
PAMS
Technical Documentation
TX I/Q
... command
Activation Status Bar Text Alt, T, Q Open the TX I/Q Tuning dialog box
This function is used for tuning TX I and Q branch DC offset, amplitude differ­ence and phase difference.
The function opens the same Start Tuning dialog box as with TX Power Tun- ing.
When this function is activated the following are automatically selected:
Active Unit = TX Operation Mode = Burst TX Power Level = 5 If TX Data Type = RANDOM => TX Data Type = 1 Update RF Information window
Service Software
Original 12/97
Page 41
Service Software Instructions
PAMS
Technical Documentation
The TX I/Q Tuning dialog box is opened. (Sample screen)
The TX I/Q Tuning dialog box contains the following items:
Tune TX I
DC Offset scroll bar (Alt+I):
The DC Offset is shown in percent (%) from the ± maximum value. 0% means that there is no DC. The value range is –100%...100%. The value is rounded to the nearest integer value.
Tune TX Q
Tune A
Tune P
OK button (Enter):
Cancel button (Esc):
After each value change, the new value is sent to the phone.
DC Offset scroll bar (Alt+Q):
The operation of this function is the same as one above, except with this selection the Q branch DC Offset is tuned. The value range is –100%...100%. The value is rounded to the nearest integer value.
mplitude Difference scroll bar (Alt+A):
When this selection is made, the user can increase or decrease the amplitude difference in 0.1 dB steps. The value range is –1...1.
hase Difference scroll bar (Alt+P):
When this selection is made, the user can increase or decrease the phase difference in 0.5° steps. The current phase difference is shown in the tuning window with numbers and bar figure. The value range is 85...95.
The dialog box is closed, and tuning
The dialog box is closed, and tuning
is saved
is not saved
to phone.
to phone.
Page 42
The following will be automatically selected when the TX I / Q tuning function is ended:
Active Unit = RX Update RF Information window
Original 12/97
PAMS
Technical Documentation
B
attery A/D... command
Activation Status Bar Text Alt, T, B Calibrate battery voltage
This function is for battery a/d tuning. Before battery a/d tuning is started, a voltage setting request is shown to the
user:
When an external power is connected, and the user selects OK to continue, the application measures a/d converter and displays the Battery A/D Calibration dialog box. (Sample screen)
Service Software
The Battery A/D Calibration dialog box contains the following items:
R
epeat button (Alt+R):
Makes measurement again.
OK button (Enter):
The dialog box is closed, and tuning
Cancel button (Esc):
The dialog box is closed, and tuning
is saved
to phone.
is not saved
to phone.
Original 12/97
Page 43
Service Software Instructions
PAMS
harger A/D... command
C
Activation Status Bar Text Alt, T, C Calibrate charger voltage
Works in the same way as the previous Battery A/D calibration.
Technical Documentation
Page 44
Original 12/97
PAMS
Technical Documentation
Testing
The Testing sub menu offers functions for ME testing.
uick Testing (RF)... command (NHK–4)
Q
Activation Status Bar Text Alt, E, Q Open the Quick Testing dialog box
This function is used for quick RF testing. The command opens the Quick Testing dialog box, which contains data for
testing and adjustments. (Sample screen)
Service Software
The Quick Testing dialog box contains the following items:
Active Unit group: RX radio button (Alt+R):
When
Original 12/97
RX
is selected, the next functions are made:
Data transmission is deactivated TX power is deactivated If operation mode is continuous,
– AGC is controlled – RX continuous mode channel is activated
If operation mode is burst,
Page 45
Service Software Instructions
PAMS
Technical Documentation
– RX and Monitoring channels are activated
RF Information window is updated The RX value is always given as default. Note! The function is activated immediately, Apply is not needed.
TX radio button (Alt+T): When
Note! The function is activated immediately, Apply is not needed.
Operation Mode group: C
TX
is selected, the next functions are made:
Data transmission is activated
Operation mode is set to burst, TX power is activated
RF Information window is updated
ontinuous radio button (Alt+C):
When
Note! The function is activated immediately, Apply is not needed.
B
Note! The function is activated immediately, Apply is not needed.
continuous
Synthesiser is set to constant frequency
Synthesiser channel number is as given with Continuous Mode
Channel selection
Transmitter power is not connected
urst radio button (Alt+B):
When
GSM/PCN receiving/transmission/measuring synthesiser.
Control sequence synthesiser channel numbers are as given with
Channel/Monitoring Channel selections.
If Active Unit is TX, data (selected with TX Data Type) is sent, and
the TX power is connected
selection is used,
burst
selection is used, the synthesiser is controlled by using
Page 46
TX D
ata Type drop list (Alt+D):
This list changes the transmission data type. The list consists of the
following options: 0, 1, and Random. After Random, data selection 0
is used. If Operating Mode is
causes different data sending than in burst mode.
TX
Power Level edit box (Alt+X):
continuous
, TX Data Type Random
Original 12/97
PAMS
Technical Documentation
With this value it is possible to change the transmission power. The
user can give the needed GSM/PCN power value (5..15/0...10) or
select the TEST or BASE. These values is found at the end of the
list.
Chan
M
Co
nel edit box (Alt+N):
The user can enter here the channel number that is used for both
transmission and receiving. The frequency of the selected channel is
shown after selection.
onitoring Channel edit box (Alt+M):
This field selects neighbouring monitoring channel. The frequency of
the selected channel is shown after selection.
ntinuous Mode Channel edit box (Alt+O):
To this edit box the user can type the continuous mode channel
which may have all PCN channel numbers (512...885).
The used frequency depends on the Active Unit. If the Active Unit is
RX, then RX frequency is used, else TX frequency. The frequency of
the selected channel is shown after selection.
Service Software
C edit box (Alt+G):
AG
This selection allows user to edit the AGC absolute value (value from
A/D converter). The AGC can have values from 0dB to 93dB in 3dB
steps in GSM, and from 0dB to 81dB in PCN. The AGC value is shown only when its value is controlled by the PC. When the
Active Unit has value RX and Operation Mode is continuous, AGC is controlled by the PC except when next adjustment functions are activated:
RSSI Calibration
AFC Diagram
AF
C edit box (Alt+F):
This selection allows the user to edit the AFC D/A converter value.
The AFC can have values from –1024 to 1023. The AFC value is the last measured AFC D/A converter value (11 bit 2–comple-
ment value is used with decimal digits). If the AFC results are not received, no text is shown.
Apply button (Alt+A):
Original 12/97
Accepts entered values and validates them. After validation, the ap-
plication sends corresponding messages to ME. Closes the dialog
box, and updates Info Window.
Page 47
Service Software Instructions
PAMS
Technical Documentation
Note: Active Unit and Operation mode command do not use the Apply button, as they are activated immediately.
Following automatic selections are made when Quick testing function is ended.
Active Unit = RX
Update RF Information window
S
et Defaults button (ALT+S):
Sets current values as default Quick Test values.
Ge
t Defaults button (ALT+E):
Gets default Quick Test values as current values.
The next table shows the dialog box’s properties in different situations: ACTIVE UNIT = TX:
TX Data Type: Updated
AGC values: Greyed
Monitoring Channel: Greyed
OPERATION MODE = BURST:
OPERATION MODE = CONT.:
ACTIVE UNIT = RX:
TX Data Type: Greyed
TX Power Level: Updated Continuous Mode Channel: Greyed Channel: Updated
TX Power Level: OFF, Greyed Continuous Mode Channel: Updated Channel: Greyed
Page 48
TX Power Level: OFF, Greyed
OPERATION MODE = BURST:
AGC values: Greyed AFC values: Greyed Continuous Mode Channel: Greyed
Original 12/97
PAMS
Technical Documentation
OPERATION MODE = CONT:
Service Software
Channel: Updated Monitoring Channel: Updated
AGC values: Updated AFC values: Updated Continuous Mode Channel: Updated Channel: Greyed Monitoring Channel: Greyed
Original 12/97
Page 49
Service Software Instructions
PAMS
elf Tests... command
S
Activation Status Bar Text Alt, E, S Open MCU Self–tests dialog box
The command is used for reading self test results and running self tests. User is first requested to run self–tests in minimum mode, or to look powerup
self–tests results with Test Type Selection dialog.
The Test Type Selection dialog has following items:
Technical Documentation
Test Type list box (ALT+S): Power up self–test results
Shows power up self–test results in MCU Powerup Self–tests dia-
log. Run Self–tests in minimum mode
Sets phone to minimum mode and opens MCU Self–tests dialog.
Page 50
Original 12/97
PAMS
Technical Documentation
MCU Powerup Self–tests
When powerup self–tests are selected the test results are read from the phone and displayed in MCU Powerup Self–tests dialog. (Sample screen)
Service Software
The MCU Powerup Self–tests dialog has following items: When powerup self–tests are selected test results are read from phone and
displayed in MCU Self–tests dialog. Tests list box (ALT+T):
Test states are updated according to the results received from the
phone. Possible test states will be one of the next:
Passed
Failed
No response
Not executed
Note that DSP test results can be asked from DSP only when all MCU tests have been passed. Possible DSP error texts are:
RAM BUS Fault,
ASIC BUS Fault,
RFI BUS Fault,
Unknown and
Original 12/97
Download Error.
Page 51
Service Software Instructions
PAMS
Technical Documentation
Bus Errors... button (ALT+B): When this selection is made Bus Test dialog is displayed. In this dialog are
shown results from the first failed MCU BUS test. When none of MCU BUS tests has been failed this selection is disabled (greyed).
The field “(s)” means that this test is selectable one. The following tests are available:
MCU Internal Test................:
MCU RAM BUS Test.................:
MCU IMEI Test....................:
MCU ROM BUS Test.................:
MCU ROM Data Test................:
MCU ASIC BUS Test.............(s):
MCU ASIC Timer and IRQX Test..(s):
MCU ASIC Timer and NMI Test...(s):
MCU Audio Codec Test..........(s):
MCU DSP Code Download Test.......:
MCU EEPROM Checksum Test.........:
Sim–Lock Checksum Test...........:
DSP Tests........................:
Page 52
Original 12/97
PAMS
Technical Documentation
MCU Self Tests
When the selection is made, the test result is read from ME. The test result will be shown to the user within the MCU Self–test dialog box. (Sample screen)
Service Software
The MCU Self–test dialog box contains the following items:
T
ests list box (Alt+T):
The field ”(p)” in the screen example means that the test is also run
in power up.
The field “/s)” means that this test is selectable one.
Test states are updated according to the results received from the
phone. Possible test states will be one of the following:
Passed
Failed
No response
Not executed
RUNNING....
Run button (Alt+R):
The user can select desired test from list and hit Run button. When
user selects test to be run, the text
state field, and test is run. When results are received, the test state
field is updated according to the result.
If no response was received in the defined time, a
will be shown and the test state is changed to
box
RUNNING...
is shown in the test
error message No response
.
Original 12/97
Page 53
Service Software Instructions
PAMS
Technical Documentation
Bus Errors... button (ALT+B): When this selection is made Bus Test dialog is displayed. In this dialog are
shown results from the first failed MCU BUS test. When none of MCU BUS tests has been failed this selection is disabled (greyed).
The following tests are available:
MCU Internal Test................(p):
RAM BUS Test......................(p):
ROM BUS Test......................(p):
ROM Data Test.....................(p):
ASIC BUS Test...................(p/s):
ASIC Timer and IRQX Test........(p/s):
ASIC Timer and NMI Test.........(p/s):
Audio Codec Test................(p/s):
RAM Component Test...................:
Ext. ROM Checksum Test...............:
Display Driver Test..................:
ASIC Type Test.......................:
EEPROM Component Test................:
EEPROM Bus Test......................:
Software Reset Test..................:
Power Off Test
Page 54
BUS Errors dialog has following items:
Failed BUS Test static text:
Name of the first failed MCU BUS test.
Address Bin Hex static text:
This static text shows, what data was written and what was read
from three different addresses. Values are given in binary and hexa-
decimal formats.
Original 12/97
PAMS
Technical Documentation
A
DC Readings... command (NHK–4)
Activation Status Bar Text Alt, E, A Open the ADC Readings dialog box
The command is used to read and show A/D values from phone. The command opens the ADC Readings dialog box: (Sample screen)
Service Software
The ADC Readings dialog box has static text fields where measurements are updated each second.
A/D Readings
The following a/d readings are measured:
Battery Voltage...................:
Charge Voltage.................:
Battery Temperature.........:
Board Temperature..........:
Junction Box Connected..:
Battery Size.........................:
HOOK Information.............:
Original 12/97
Page 55
Service Software Instructions
PAMS
dio... command
Au
Activation Status Bar Text Alt, E, U Open Audio Tests dialog box
The command is used for making audio tests in the Audio Tests dialog box. The Audio Tests dialog box contains following items:
Technical Documentation
Page 56
Audio Tests dialog has following items: Buzzer Volume group:
Next three different values can be selected for Buzzer volume:
O
ff radio button (ALT+O):
Turns buzzer off.
L
ow radio button (ALT+L):
Turns buzzer low. The frequency used in buzzer control is 1600 Hz.
Hig
h radio button (ALT+G):
Turns buzzer high. The frequency used in buzzer control is 1600 Hz.
Original 12/97
PAMS
Technical Documentation
Internal Audio Loop group: Input group:
Next two different values can be selected for input:
I
nternal radio button (ALT+I):
Turns internal input.
E
xternal radio button (ALT+I):
Turns external input. Output group:
Next two different values can be selected for output:
Int
ernal radio button (ALT+T):
Turns internal output.
Ex
ternal radio button (ALT+X):
Turns external output. Loop group:
Service Software
Next two different values can be selected for loop:
Off
radio button (ALT+F):
Turns audio loop off.
On
radio button (ALT+N):
Turns audio loop on.
External Audio Loop group: Interface group:
Next three different values can be selected for interface:
Hs
radio button:
Selects handset interface for external audio loop and makes mea-
surement. After measurement Off button is checked automatically.
Hf
radio button (ALT+N):
Selects hands–free interface for external audio loop and makes
measurement. After measurement Off button is checked automati-
cally.
button (ALT+F):
Off
Original 12/97
Check box showing that external audio loop is not on.
Note: User does not have to end external audio loop with this button.
Note: When a button is checked in this group, application first checks
if internal audio loop is on. If internal audio loop was on, it is ended
and Off button is checked Loop group.
Page 57
Service Software Instructions
PAMS
Measurements group:
When dialog box is closed, the Buzzer Volume is always switched off. Also In­ternal Audio Loop is turned off.
D
isplay... command
Technical Documentation
Line ”Frequency/Hz” shows three frequencies, that are used in mea-
surements. Lines ”OUT OF RANGE” and ”Received level” will be
shown only after actual measurement. Received level values have
scale from 0 to 256. Received signal strength is square of the re-
ceived value. ”OUT OF RANGE” text is only shown, when measure-
ment values are not in acceptable range. Acceptable ranges are:
Frequency f/Hz
300 1000 3000
HS Interface
value
15...35
22...42
22...42
HF Interface
value
53...73
58...78
58...78
Activation Status Bar Text Alt, E, D Open Display Tests dialog box
This command is used for making display tests in the Display Tests dialog box.
The Display Tests dialog box contains the following items:
1
. Test Pattern radio button (Alt+1):
In test display 1 all indicators are displayed, and the display is filled
with chessboard letters.
2
. Test Pattern radio button (Alt+2):
In test display 2 the remainder (from test 1) of the indicators are dis-
played, and the display is filled with inverse chessboard letters.
Page 58
When the dialog box is closed, the phone LCD display is cleared.
Original 12/97
PAMS
Technical Documentation
C
all Simulation.. command
Activation Status Bar Text Alt, E, C Open Call Simulation dialog box
The command is used for making call simulation. The function opens the Call Simulation dialog box. (Sample screen)
Service Software
The Call Simulation dialog box contains the following items:
T
X Power Level edit box (Alt+T):
All power levels can be selected. This updates same parameter as
TX Power Level in the RF–Controls dialog box. Note that TEST
value cannot be selected. If TEST or BASE value was in use when
Call simulation menu selected, power level is changed to smallest
value.
hannel edit box (Alt+C):
C
This tells the normal operating RF channel number. Normal GSM/
PCN channel numbers can be selected. Same channel is used both
for transmission and receiving. This updates same parameter as
Channel in the RF–Controls dialog box. Monitoring Channels group: Channel 1,2,3,4,5,6 edit box (Alt+1,2,...):
Channels for monitoring are specified with these six selections. All
GSM/PCN channel numbers can be used. If more than one selection
has same number, the monitoring channel list (neighbour list) will
have less than 6 selected channels. The minimum number of moni-
toring channels is one (all channels have same value). The monitor-
ing channel can also have same value as normal operating channel.
Original 12/97
Page 59
Service Software Instructions
PAMS
The first monitoring channel updates the same parameters as Moni-
toring Channel in the RF–Controls dialog box.
pply button (Alt+A):
A
Validates and sends entered data to ME.
Noise Sensitivity... command
Activation Status Bar Text Alt, E, N Opens Noise Sensitivity dialog box
The command is used for noise sensitivity measurement. The following are automatically selected when this tuning function is activated: – Active Unit = RX – Operation mode = Continuous – AGC = 81 dB The function opens information dialog box, telling the user to use signal gener-
ator when measuring signal and not to use signal generator when measuring noise. When the user has accepted information, the application then opens the Noise Sensitivity dialog box. (Sample screen)
Technical Documentation
Page 60
The Noise Sensitivity dialog box contains the following items: Measurements group:
Clipping distance is the difference to the signal clipping value. SNR
is measured in the AD converter.
Clipping distance = clipping level (66) – signal value + comp_factor1
SNR = signal value – noise value + comp_factor1
Original 12/97
PAMS
Technical Documentation
Sensitivity = –92 dBm + 8 dB + comp_factor2 – SNR (for GSM)
Sensitivity = –90 dBm + 8 dB + comp_factor2 – SNR (for PCN)
The last value on the display is signal power difference between I
and Q branch. The numbers are shown in 0.1 dB accuracy. The error
messages, ”OUT OF RANGE”, are shown only if the SNR and/or
amplitude difference values are not acceptable (SNR <= 18 dB +
comp_factor2 – 0.5 dB(= accuracy) ; Sensitivity >= –100 dBm + 0.5
dB ; |Si – Sq| > 1 dB).
ignal/Noise radio button (Alt+S/Alt+N):
S
When buttons are pressed, the RX I and Q burst data is asked. The
signal level value should be –90 dBm for PCN during signal mea-
surement.
When signal data is received, distance to clipping signal level is
shown as dBs on the display. When either signal or noise measure-
ment results are received, measurements are updated to screen.
When both measurements (signal and noise) are done at least once,
the signal to noise relation and difference are also shown on the dis-
play.
Service Software
After exiting the dialog box, the following are set to the values which were se­lected before this adjustment.
– Active Unit
– Operation mode
– AGC value Compensation factors: comp_factor1 = 4.64 dB (Compensation factor for 67.71 kHz signal, because
ASIC filter attenuates 67.71 kHz signal 4.64 dB) comp_factor2 = 2.27 dB (Compensation factor for real and calculated noise
bandwidth difference. Real noise bandwidth is 80 kHz and calculated band­width is 135 kHz)
Original 12/97
Page 61
Service Software Instructions
PAMS
Software
The settings sub menu offers functions for Mobile Equipment mode and memory settings.
roduct Profile... command (NHK–4)
P
Activation Status Bar Text Alt, S, P Open Product Profile Settings dialog box
The function is used for making product profile settings.
When the command is activated, the product profile information is read from the EEPROM and the Product Profile dialog box is opened.
Technical Documentation
Page 62
Note: This is only a screen example, actual settings are explained in more de­tail in the following section.
The Product Profile dialog box contains the following items:
S
ettings list box (Alt+S):
A list where the user can select desired setting.
The user can toggle settings with following Options drop list, or by
double clicking the desired setting in list box.
O
ptions drop list (Alt+O):
List allows user to set options to each setting listed in the Settings
list box. OK button (ENTER)
Original 12/97
PAMS
Technical Documentation
Selections are accepted and saved to EEPROM. Cancel button (ESC)
Selections are ignored and control is returned back to main menu.
S
ave File... button
Allows the user to save settings to file. Opens a standard windows
File Save dialog box. L
oad File... button
Allows the user to load the settings from a file. Opens a standard
windows File Open dialog box.
tart Up Self–tests... command
S
Activation Status Bar Text
Service Software
Alt, S, S Open MCU Start Up Self–tests dialog box The function is used for changing the state of the EEPROM selectable tests in
the MCU Start Up Self–tests dialog box.
The MCU Start Up Self–tests dialog box contains the following items:
T
ests list box (Alt+T):
When dialog box is opened, the previous values will be read from the
MCU EEPROM and shown on the list box.
Status group:
OK button (Enter)
Original 12/97
When radio button On is selected, the test will be run every time
when automatic start up self–tests are activated (e.g. in power up).
Selections are accepted and saved to EEPROM.
Page 63
Service Software Instructions
PAMS
Cancel button (Esc)
Set Default V
Activation Status Bar Text Alt, S, V Set factory default values
The command is used for resetting default values to phone’s EEPROM. After selection application asks confirmation: “Are you really sure you want
make factory settings to phone?”. If Yes is answered, default settings are made to phone and phone must be tuned !
Technical Documentation
Selections are ignored and control is returned back to main menu.
alues... command
Page 64
Original 12/97
PAMS
Technical Documentation
Dealer
The dealer sub menu offers functions for Mobile Equipment settings for deal­ers.
Short C
ode Memory... command
Activation Status Bar Text Alt, D, C Opens the Edit SCM dialog box.
This command is used for reading, storing and modifying the SCM values. Short code memory data is read only from the internal memory of the phone
(not from SIM card). After menu selection program makes
phone?”. If user answers Yes, all needed SCM entries will be read from the ME. During all reading, writing, loading and storing operations program shows
message
1..N and N is the number of SCM entries in the phone. With this dialog user can cancel the current operation with Cancel button. If a reading error happens, an
error
(Sample screen)
dialog: ”Please be patient reading entry n of N entries.” Where n is
dialog is shown. If reading succeed, Edit SCM dialog is opened.
query
Service Software
dialog: “Read SCM entries from
Original 12/97
Page 65
Service Software Instructions
PAMS
The Edit SCM dialog box contains the following items: Loc static text:
Index of active SCM entry and is read only.
me edit box (ALT+A):
Na
Edit name part of the active entry in SCM list box. Maximum length is
20 and valid characters in name field are 0AH..0FFH (in ME charac-
ter codes).
N
umber edit box (ALT+N):
Edit number part of the active entry in SCM list box. Maximum length
is 30 and valid characters in number field are all digits 0..9, ”*”, ”#”,
”p”, ”P”, ”w”, ”W” and ”+”.
M list box (ALT+C):
SC
User can select one of SCM entries to edit. Editing is done in Num-
ber and Name edit boxes. If there is more entries than can be
shown, list box can be scrolled.
Technical Documentation
rite Phone... button (ALT+W):
W
Writes all SCM entries to phone. If there are invalid characters in
name or number fields they are converted to ‘?’ and user is informed
after operation. Opens Message box informing user which entry is
being written to phone and how many entries there are altogether.
User can cancel operation with Cancel button.
ead Phone... button (ALT+R):
R
Reads all SCM entries from phone. Opens Message box informing
user which entry is being read from phone and how many entries
there are altogether. User can cancel operation with Cancel button.
S
ave File... button (ALT+S):
Opens a default Windows File Save As dialog box and asks file-
name where to save SCM entries. If there are invalid characters in
the name or number fields they are converted to ‘?’ and user is in-
formed after operation.
oad File... button (ALT+L):
L
Opens a default Windows File Open dialog and asks filename where
from load SCM entries. If there are invalid characters in name or
number fields they are converted to ‘?’ and user is informed after op-
eration.
Page 66
Original 12/97
PAMS
Technical Documentation
U
ser Settings... command
Activation Status Bar Text Alt, D, U Open User Settings and Values dialog box
This command is used to read, store, and modify the user settings and values. After menu selection, the program responds with a
user settings from phone?”. If user answers Yes, all needed user settings will be read from the ME, including menu settings. If a reading error happens, an
error
dialog box is shown. If reading is successful, the User Settings and Val-
ues dialog box is opened: (Sample screen)
query
Service Software
dialog box: “Read
The User Settings and Values dialog box contains the following items:
Se
curity ID edit box (Alt+E):
Edit the security code which is saved to the ME memory together
with other user settings and values. Only digits are accepted for Se-
curity code. Length must be 5 digits. Master Code static:
Code is 10 digits length and it is read only.
Wake up M
S
ave File... button (Alt+S):
oad File... button (Alt+L):
L
essage edit box (Alt+M):
Edit Wake up message. The wake up message name can have up to
30 characters.
Opens a default Windows File Save As dialog box and asks file-
name where to save user settings and values.
Opens a default Windows File Open dialog box and asks filename
where from load user settings and values.
Original 12/97
Page 67
Service Software Instructions
PAMS
Data entered in the dialog box is checked validity before it is sent to the phone. If the application finds wrong characters from Wake up message, application will inform the user and requests correction.
Both save file and load file function have default name which is previously used name. For instance, if user data was saved to file USERA.USR and read func­tion is activated the default value is USERA.USR.
Set UI Default V
Activation Status Bar Text Alt, D, V Reset phone to UI and SCM factory settings
After selection, the application asks confirmation: “Are you sure you want make UI and SCM factory settings to phone?”. If Yes is answered, default settings are made to phone.
Technical Documentation
alues... command
Page 68
Original 12/97
PAMS
Technical Documentation
View
Quick/RF Info... command (NHK–4)
Activation Status Bar Text Alt, V, R View Quick/RF information
Opens a Quick/RF Info dialog which shows RF–information. Information is shown in a modeless dialog which may be left open during other operations. It is also updated when ever needed. (Sample screen)
Service Software
Phone Identity... command
Activation Status Bar Text Alt, V, P View phone identity information
The command opens the Phone Identity Information dialog box, which shows identification information. Information is shown in a modeless dialog box, which may be left open during other operations. It is also updated when ever needed. (Sample screen)
Original 12/97
Page 69
Service Software Instructions
PAMS
Help
The Help menu offers commands which provide assistance with this applica­tion:.
ndex command
I
Activation Status Bar Text Alt, H, I Provide general instructions on using help
The command displays the opening screen of Help. From the opening screen, the user can jump to step–by–step instructions for using Service Software and various types of reference information.
Once Help is opened, the user can click the Contents button whenever he wants to return to the opening screen.
eneral help command
G
Activation Status Bar Text
Technical Documentation
Alt, H, G General help
sing Help command
U
Item Activation Status Bar Text Using Help Alt, H, U Display using help system
bout... command
A
Activation Status Bar Text Alt, H, A Displays the version number of this application
See Login Dialog.
information
SHIFT F1
Page 70
Original 12/97
PAMS
Technical Documentation

Initialization File

The service software has its own initialization file which has the extension .INI. The Initialization file is TESLA.INI and includes all the following selections (in mentioned menus or dialog boxes) and parameters:
RF Controls dialog box ([RF Controls])
Active Unit (Active Unit =)
TX Power Level (TX Power Level =)
Operation Mode (Operation Mode =)
TX Data Type (TX Data Type =)
Continuous Mode Channel (Cont Mode Channel =)
Channel (Channel =)
Monitoring Channel 1 (Monitoring Channel 1 =)
AGC dB value (AGC =)
AFC (AFC =)
Service Software
Call Simulation dialog ([Call Simulation])
Monitoring Channel 2 (Monitoring Channel 2 =)
Monitoring Channel 3 (Monitoring Channel 3 =)
Monitoring Channel 4 (Monitoring Channel 4 =)
Monitoring Channel 5 (Monitoring Channel 5 =)
Monitoring Channel 6 (Monitoring Channel 6 =) All selections and parameters which are not the same as in the RF Controls
menu.
TX Power Tuning dialog ([TX Power Tuning])
TX power coefficients
TX I/Q Tuning dialog ([TX I/Q Tuning])
TX I/Q
Original 12/97
Page 71
Service Software Instructions
PAMS

Appendix 1, Vocabulary

Appreviation Description AFC Automatic Frequency Control
AGC Automatic Gain Control API Application Programming Interface ASIC Custom circuit which for instance controls communication
between MCU and DSP CLF Common Look and Field DATA DATA interface module DAU–4S M2BUS – RS–232 adapter DCT2 Digital Core Technology Second Generation DLL Dynamic Link Library DSP Digital signal processor which controls radio interface and
speech coding/decoding
Technical Documentation
EEPROM Memory for adjustment parameters (Electrically Erasable
and Programmable Read Only Memory) IMEI International Mobile Equipment Identification code M2BUS Serial communication bus which can be connected to
accessory devices and test PC MCU Master Control Unit processor MDI MCU DSP Interface; message interface via ASIC registers ME Mobile Equipment MFC Microsoft Foundation Class library MS Mobile Station MTI Message Transfer Interface PC IBM PS/AT or compatible personal computer PCBOX Local Net driver SW for PC PCI Phone Controlling Interface SW for PC PKD Parallel Port Software Protection Device RF Radio Frequency parts
Page 72
RFI Radio Frequency Interface circuit RSSI Received Signal Strength Indication SW Software UI User Interface
Original 12/97