Nascom N78CWSHK-STHS, N78CW-STSD, N78CG-SWSD, N78CG-STFB, N78CWSHK-STSD Specsheet

...
Nascom N78CWSHK-STHS, N78CW-STSD, N78CG-SWSD, N78CG-STFB, N78CWSHK-STSD Specsheet

N78C

3/4” RECESSED WIDE GAP STANDARD DOOR CONTACT SET

DESCRIPTION

Nascom’s N78C Series is a 3/4” recessed wide gap door contact designed for residential, commercial and industrial steel and wood door applications.

The N78C is the installer’s choice of contact configuration because the contact set is designed to cut installation times and helps to prevent false alarms caused by shifting or warping doors.

The N78C Series is designed for installation in every type of hinged door including wood doors.

FEATURES

SNAP FIT ON STEEL - NO GLUE REQUIRED

ENCAPSULATED HERMETICALLY SEALED CONTACTS

12” 22AWG WIRE LEADS

POLYPROPYLENE HOUSINGS

WIDE GAP - N35 NdFeB RARE EARTH MAGNET

LISTED TO UL634 STANDARD

ORDERING INFORMATION

 

 

OPERATE

 

CONTACT RATING

 

STATIC

 

 

 

(Max DC/Peak AC Resistive)

 

PART

 

CONTACT

 

COLOR

GAP

 

 

 

 

 

NUMBER

SWITCHING

CARRY

RESISTANCE

 

 

(in inches)

 

 

 

V

I

V

I

(50mV, 100mA)

 

 

 

 

 

 

 

 

 

 

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

 

 

N78CB/ST

BROWN

 

 

 

 

 

 

 

N78CG/ST

GREY

1.00 to 2.00

200 VDC

0.5 Amps

10vA

1.5 Amps

150 mOhms

 

N78CT/ST

TAN

 

 

 

 

 

 

 

 

N78CW/ST

WHIITE

 

 

 

 

 

 

 

DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

 

 

N78CB/ST2CR

BROWN

 

 

 

 

 

 

 

N78CG/ST2CR

GREY

1.00 to 2.00

200 VDC

0.5 Amps

10vA

1.5 Amps

150 mOhms

 

N78CT/ST2CR

TAN

 

 

 

 

 

 

 

 

N78CW/ST2CR

WHIITE

 

 

 

 

 

 

 

OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET:

 

 

 

 

N78CB/STFB

BROWN

 

 

 

 

 

 

 

N78CG/STFB

GREY

0.75 to 1.25

30 VDC

0.2 Amps

3vA

0.5 Amps

150 mOhms

 

N78CT/STFB

TAN

 

 

 

 

 

 

 

 

N78CW/STFB

WHIITE

 

 

 

 

 

 

 

SINGLE POLE DOUBLE THROW, SWITCH/MAGNET SET:

 

 

 

 

N78CB/STSD

BROWN

 

 

 

 

 

 

 

N78CG/STSD

GREY

0.75 to 1.25

30 VDC

0.2 Amps

3vA

0.5 Amps

150 mOhms

 

N78CT/STSD

TAN

 

 

 

 

 

 

 

 

N78CW/STSD

WHIITE

 

 

 

 

 

 

 

DOUBLE POLE DOUBLE THROW, SWITCH/MAGNET SET:

 

 

 

 

N78CB/STDD

BROWN

 

 

 

 

 

 

 

N78CG/STDD

GREY

0.75 to 1.25

30 VDC

0.2 Amps

3vA

0.5 Amps

150 mOhms

 

N78CT/STDD

TAN

 

 

 

 

 

 

 

 

N78CW/STDD

WHIITE

 

 

 

 

 

 

 

HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

 

 

N78CB/STHS

BROWN

 

 

 

 

 

 

 

N78CG/STHS

GREY

0.1875 to

300 VDC

0.25

10vA

0.25

150 mOhms

 

N78CT/STHS

TAN

0.5000

Amps

Amps

initial

 

 

 

 

N78CW/STHS

WHIITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DWG No. 140204-02 Rev. 1

 

 

 

 

 

Royne Industries LLC, dba NASCOM |

P: 800.843.5530 |

F: 800.727.4041

| www.nascominc.com

38

N78C

3/4” RECESSED WIDE GAP STANDARD DOOR CONTACT SET

WIRING SCHEMATIC

 

 

 

 

 

 

SWITCH

SWITCH

CONTACT

CONTACT

 

 

 

 

 

 

 

 

 

 

 

 

CLOSED LOOP,

 

OPEN LOOP,

 

DUAL CLOSED LOOP,

NORMALLY OPEN CONTACT

NORMALLY CLOSED CONTACT

NORMALLY OPEN CONTACTS

 

 

NC, OPEN LOOP (WHITE)

 

 

 

COMMON

 

NO, CLOSED LOOP (RED)

 

 

NC, OPEN LOOP (WHITE)

(BROWN)

 

NC, OPEN LOOP (WHITE)

COMMON

 

NO, CLOSED LOOP (RED)

 

 

 

 

COMMON

 

NC, OPEN LOOP (RED)

(BROWN)

 

 

(BROWN)

 

 

 

 

 

DPDT, DOUBLE POLE DOUBLE THROW

SPDT, SINGLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

 

 

 

 

 

.910

.730

 

.910

.730

 

 

23.11

18.54

 

23.11

18.54

 

TOP

 

 

TOP

 

 

VIEW

 

 

 

 

.490

 

VIEW

 

 

 

 

 

 

 

12.45

 

 

.490

 

 

 

 

 

 

 

 

 

 

12.45

 

 

1.100

.375

 

1.100

.375

FRONT VIEW

9.53

FRONT VIEW

9.53

27.94

 

27.94

 

 

 

 

 

 

 

 

 

.060

 

 

 

.060

 

1.52

 

 

 

1.52

 

 

 

 

 

 

SWITCH

 

 

MAGNET

 

INSTALLATION INSTRUCTIONS

Mark location for the switch on the door frame and mark the location for the magnet on the door.

Make sure switch and magnet hole locations are aligned.

Drill holes for the switch and magnet using a 3/4” Hole Saw for steel doors or a Forstner bit for wood doors.

Press the magnet into the hole in the door until seated firmly against the head. Silicone may be used to secure the magnet in wood doors.

Connect the switch leads to the alarm circuit conductors. Hold the wire leads (not the switch housing) when cutting and stripping to prevent damage to the switch.

Feed the switch conductors into the hole and insert the switch housing pressing firmly until seated. Silicone may be used to secure the switch in wood doors.

Test switch for correct operation and make sure gap performance is acceptable.

DWG No. 140204-02 Rev. 1

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com

39

Loading...