Nascom N400W-SWSD, N400W-SWHS, N400W-SWFB, N400W-SWDD, N400W-SW2CR Specsheet

...

N400

INDUSTRIAL BAR SWITCH SET WITH JACKETED WIRE LEADS

DESCRIPTION

Nascom’s N400 4 inch industrial bar contact with jacketed leads protects steel and wood doors in commercial settings.

The N400 is the installer’s choice of contact configuration where extra wide air and side-to-side gap are required to prevent false alarms caused by shifting or warping doors. The N400 offers convenient installation with center wire leadout.

FEATURES

 

 

ENCAPSULATED HERMETICALLY SEALED CONTACTS

ABS HOUSING

 

EXTRA WIDE GAP - N35 NdFeB RARE EARTH MAGNET

SPACER FOR STEEL DOOR INSTALLS

JACKETED CENTER WIRE

LISTED TO UL634 STANDARD

ORDERING INFORMATION

 

 

 

 

OPERATE

 

CONTACT RATING

 

PART

 

(Max DC/Peak AC Resistive)

COLOR

GAP

SWITCHING

CARRY

NUMBER

 

(in inches)

 

 

V

I

V

I

 

 

 

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

 

N400B/ST

BROWN

 

 

 

 

 

N400G/ST

GREY

1.50 to 2.50

200 VDC

0.5 Amps

10vA

1.5 Amps

N400T/ST

TAN

 

 

 

 

 

N400W/ST

WHITE

 

 

 

 

 

DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

N400B/ST2CR

BROWN

 

 

 

 

 

N400G/ST2CR

GREY

1.50 to 2.50

200 VDC

0.5 Amps

10vA

1.5 Amps

N400T/ST2CR

TAN

 

 

 

 

 

N400W/ST2CR

WHITE

 

 

 

 

 

OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET:

 

 

N400B/STFB

BROWN

 

 

 

 

 

N400G/STFB

GREY

1.25 to 2.25

30 VDC

0.2 Amps

3vA

0.5 Amps

N400T/STFB

TAN

 

 

 

 

 

N400W/STFB

WHITE

 

 

 

 

 

SINGLE POLE, DOUBLE THROW SWITCH/MAGNET SET:

 

 

N400B/STSD

BROWN

 

 

 

 

 

N400G/STSD

GREY

1.25 to 2.25

30 VDC

0.2 Amps

3vA

0.5 Amps

N400T/STSD

TAN

 

 

 

 

 

N400W/STSD

WHITE

 

 

 

 

 

DOUBLE POLE, DOUBLE THROW SWITCH/MAGNET SET:

 

 

N400B/STDD

BROWN

 

 

 

 

 

N400G/STDD

GREY

1.25 to 2.25

30 VDC

0.2 Amps

3vA

0.5 Amps

N400T/STDD

TAN

 

 

 

 

 

N400W/STDD

WHITE

 

 

 

 

 

HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

 

N400B/STHS

BROWN

 

 

 

 

 

N400G/STHS

GREY

0.1875 to .050

300 VDC

0.25

10vA

0.25

N400T/STHS

TAN

Amps

Amps

 

 

 

N400W/STHS

WHITE

 

 

 

 

 

STATIC

CONTACT

RESISTANCE (50mV, 100mA)

150 mOhms

150 mOhms

150 mOhms

150 mOhms

150 mOhms

150 mOhms initial

DWG No. 130212-03 Rev. 1

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com

1

Nascom N400W-SWSD, N400W-SWHS, N400W-SWFB, N400W-SWDD, N400W-SW2CR Specsheet

N400

INDUSTRIAL BAR SWITCH SET WITH JACKETED WIRE LEADS

WIRING SCHEMATIC

 

 

 

 

 

 

SWITCH

SWITCH

CONTACT

CONTACT

 

 

 

 

 

 

 

 

 

 

 

 

CLOSED LOOP,

OPEN LOOP,

 

 

 

 

 

 

 

DUAL CLOSED LOOP,

NORMALLY OPEN CONTACT

NORMALLY CLOSED CONTACT

NORMALLY OPEN CONTACTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC, OPEN LOOP (WHITE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC, OPEN LOOP (WHITE)

 

COMMON

 

 

 

 

 

 

NO, CLOSED LOOP (RED)

 

 

 

 

 

 

 

 

 

COMMON

 

 

NO, CLOSED LOOP (RED)

 

(BROWN)

 

 

 

NC, OPEN LOOP (WHITE)

 

 

 

 

 

 

(BROWN)

 

 

 

COMMON

 

 

 

 

 

NC, OPEN LOOP (WHITE)

 

 

 

 

 

(BROWN)

 

 

 

 

 

 

SPDT, SINGLE POLE DOUBLE THROW

 

DPDT, DOUBLE POLE DOUBLE THROW

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS - IN [mm]

 

 

2X

.140

TOP

 

 

3.56

 

 

 

VIEW

 

 

.500

 

3.470

 

 

 

12.70

 

88.14

END

 

 

 

 

 

FRONT

 

VIEW

 

 

 

 

VIEW

 

 

 

 

3.950

 

.560

 

100.33

 

14.22

SWITCH

 

2X

.140

 

2X

.140

 

TOP

 

3.56

TOP

 

3.56

 

 

 

 

VIEW

 

.560

VIEW

 

.500

 

3.470

3.470

 

 

14.22

88.14

 

12.70

 

88.14

 

 

 

 

.120

 

FRONT

END

 

 

 

VIEW

FRONT

3.05

 

VIEW

 

3.950

 

 

VIEW

 

 

 

 

.560

3.950

 

100.33

 

 

14.22

 

 

 

 

 

100.33

 

 

MAGNET

 

SPACER

 

INSTALLATION INSTRUCTIONS

Note: High Security model – Dots on switch and magnet must be aligned for correct operation.

Installation on Steel Doors - Use the enclosed spacers under the switch and magnet.

Position the switch on the door frame and the magnet on the door in desired location.

Align the switch and magnet housings as close as possible on the door with ¼” gap between the housings.

Mark the mounting hole locations and drill mounting holes using a drill bit adequately sized for a #6 self-tapping screw.

Attach the switch to the door frame using two #6 Self-Tapping screws.

Attach the magnet to the door using two #6 Self-Tapping screws.

Connect an ohm meter to the switch leads and open and close the door to test switch for correct operation.

Connect the switch leads to the alarm system. Caution Hold wire leads, not the switch housing while cutting and stripping to prevent damage to switch.

Test alarm system for correct operation

DWG No. 130212-03 Rev. 1

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com

2