Nascom N75W-SWHS, N75W-SWFB, N75W-SW2CR, N75W-SW, N75W-STHS Specsheet

...
Nascom N75W-SWHS, N75W-SWFB, N75W-SW2CR, N75W-SW, N75W-STHS Specsheet

N75

3/8” RECESSED STANDARD DOOR CONTACT SET

DESCRIPTION

Nascom’s N75 Series standard length 3/8” recessed contact protects all nonferrous (e.g. wood, aluminum and vinyl) doors and windows in both residential and commercial settings.

The N75 is the installer’s choice of contact configuration where drill depth is not a concern and maximum air and side-to-side gaps are required to prevent false alarms caused by shifting or warping doors and windows.

FEATURES

PRESS FIT - NO GLUE REQUIRED

ENCAPSULATED HERMETICALLY SEALED CONTACTS

12” 22AWG WIRE LEAD

POLYPROPYLENE HOUSINGS

WIDE GAP - N35 NdFeB RARE EARTH MAGNET

LISTED TO UL634 STANDARD

ORDERING INFORMATION

 

 

OPERATE

 

CONTACT RATING

 

PART

 

(Max DC/Peak AC Resistive)

COLOR

GAP

SWITCHING

CARRY

NUMBER

 

(in inches)

 

 

V

I

V

I

 

 

 

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

 

N75B/ST

BROWN

 

 

 

 

 

N75G/ST

GREY

0.80 to 1.25

200 VDC

0.5 Amps

10vA

1.5 Amps

N75W/ST

WHIITE

 

 

 

 

 

DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

N75B/ST2CR

BROWN

 

 

 

 

 

N75G/ST2CR

GREY

0.80 to 1.25

200 VDC

0.5 Amps

10vA

1.5 Amps

N75W/ST2CR

WHIITE

 

 

 

 

 

OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET:

 

 

N75B/STFB

BROWN

 

 

 

 

 

N75G/STFB

GREY

0.65 to 0.90

30 VDC

0.2 Amps

3vA

0.5 Amps

N75W/STFB

WHIITE

 

 

 

 

 

SINGLE POLE, DOUBLE THROW SWITCH/MAGNET SET:

 

 

N75B/STSD

BROWN

 

 

 

 

 

N75G/STSD

GREY

0.65 to 0.90

30 VDC

0.2 Amps

3vA

0.5 Amps

N75W/STSD

WHIITE

 

 

 

 

 

DOUBLE POLE, DOUBLE THROW SWITCH/MAGNET SET:

 

 

N75B/STDD

BROWN

 

 

 

 

 

N75G/STDD

GREY

0.65 to 0.90

30 VDC

0.2 Amps

3vA

0.5 Amps

N75W/STDD

WHIITE

 

 

 

 

 

HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:

 

 

N75B/STHS

BROWN

 

 

0.25

 

0.25

N75G/STHS

GREY

0.27 to 0.70

300 VDC

10vA

Amps

Amps

N75W/STHS

WHIITE

 

 

 

 

 

 

 

 

STATIC

CONTACT

RESISTANCE (50mV, 100mA)

150 mOhms

150 mOhms

150 mOhms

150 mOhms

150 mOhms

150 mOhms initial

DWG No. 120524-03 Rev. 2

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com

1

N75

3/8” RECESSED STUBBY DOOR CONTACT SET

WIRING SCHEMATIC

 

 

 

 

 

 

SWITCH

SWITCH

CONTACT

CONTACT

 

 

 

 

 

 

 

 

 

 

 

 

CLOSED LOOP,

OPEN LOOP,

 

 

 

 

 

 

DUAL CLOSED LOOP,

NORMALLY OPEN CONTACT

NORMALLY CLOSED CONTACT

NORMALLY OPEN CONTACTS

 

 

 

 

 

 

 

 

 

 

 

NC, OPEN LOOP (WHITE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC, OPEN LOOP (WHITE)

COMMON

 

 

 

 

 

 

NO, CLOSED LOOP (RED)

 

 

 

 

 

 

 

 

COMMON

 

 

NO, CLOSED LOOP (RED)

(BROWN)

 

 

 

NC, OPEN LOOP (WHITE)

(BROWN)

 

COMMON

 

 

 

NC, OPEN LOOP (WHITE)

 

 

 

 

(BROWN)

 

 

SPDT, SINGLE POLE DOUBLE THROW

DPDT, DOUBLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

1.295

12.00

 

1.295

32.89

304.80

.450

32.89

.450

.375

 

11.43

11.43

 

9.53

 

 

 

 

 

 

 

.375

 

2X

.050

9.53

 

 

 

 

1.27

 

END VIEW

FRONT VIEW

END VIEW

FRONT VIEW

SWITCH MAGNET

INSTALLATION INSTRUCTIONS

Mark location for the switch on the door frame and mark the location for the magnet on the top edge of the door.

Make sure switch and magnet hole locations are aligned.

Using a square, transfer the marks on to the top edge of the door and the opposing door frame.

Using a tape measure or graduations on the square, locate the center of the door edge and place an intersecting line with the first mark. Drill a 3/8” hole at the location where the marks intersect.

Repeat the above step to locate the hole position for the switch in the door frame. Drill a 3/8” hole in the door frame.

Press the magnet into the hole you drilled in the door until flush with top edge of door.

Connect the switch leads to the alarm system. Caution! Hold wire leads, not the switch housing while cutting and stripping to prevent damage to switch.

Insert wire leads into hole followed by the switch and press the switch into the hole until the head is flush with the door frame

Test switch for correct operation and make sure gap performance is acceptable.

DWG No. 120524-06 Rev. 2

Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com

2

Loading...