McIntosh MR-7083 Owners manual

IMPORTANT SAFETY INSTRUCTIONS
THESE INSTRUCTIONS ARE TO
PROTECT YOU AND THE MclNTOSH INSTRUMENT. BE SURE TO FAMILIARIZE YOURSELF WITH THEM.
1. Read all instructions - Read the safety and operating instructions before operating the instrument.
2. Retain Instructions - Retain the safety and operating instructions for future reference.
3. Heed warnings - Adhere to warnings and operating instructions.
4. Follow Instructions - Follow all operating and use instructions.
WARNING: TO REDUCE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT EXPOSE THIS INSTRUMENT TO RAIN OR MOISTURE.
5. Power Sources - Connect the power supply only to the type described in the operating instructions or as marked on the unit.
6. Power-Cord Protection - Route power-supply cords so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the instrument.
7. Ventilation - Locate the instrument for proper ventilation. For example, the instrument should not be placed on a bed, sofa, rug, or similar surface that may block ventilation openings; or, placed in a built-in installation, such as a bookcase or cabinet, that may impede the flow of air through the ventilation openings.
8. Heat - Locate the instrument away from heat sources such as radiators, heat registers, stoves, or
other appliance (including amplifiers) that produce
heat.
9. Wall or Cabinet Mounting - Mount the instrument
in a wall or cabinet only as described in the owners manual.
10. Water and Moisture - Do not use the instrument near water - for example, near a bathtub,
washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc.
11. Cleaning - Clean the instrument by dusting with a
dry cloth. Clean the panel with a cloth moistened with a window cleaner.
12. Object and Liquid Entry - Do not permit objects to
fall and liquids to spill into the instrument through enclosure openings.
13. Nonuse Periods - Unplug the power cord from the AC power outlet when left unused for a long
period of time.
14. Damage Requiring Service - Service must be performed by qualified service personnel when: A. The power supply cord or the plug has been damaged; or
B. Objects have fallen, or liquid has been spilled into the instrument; or
C. The instrument has been exposed to rain; or
D. The instrument does not appear to operate nor­mally or exhibits a marked change in performance;
or
E. The instrument has been dropped, or the enclosure damaged.
15. Servicing - Do not attempt to service beyond that described in the operating instructions. All other
service should be referred to qualified service
personnel.
16. Grounding or Polarization - Do not defeat the
inherent design features of the polarized plug. Non-polarized line cord adaptors will defeat the safety provided by the polarized AC plug.
17. CAUTION: TO PREVENT ELECTRICAL SHOCK DO
NOT USE THIS (POLARIZED) PLUG WITH AN
EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
ATTENTION: POUR PREVENIR LES CHOCS ELECTRIQUES PAS UTILISER CETTE FICHE POLARISEE AVEC UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER AUCUNE PAR­TIE A DECOUVERT.
The lightning flash with arrowhead, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The serial number, purchase date, and Mclntosh
Laboratory Service Contract number are important to
you for possible insurance claim or future service.
Record this information here.
Serial Number
CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
The exclamation point within an equilateral triangle
is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Purchase Date
Service Contract Number
Upon application, Mclntosh Laboratory provides a Service Contract to the original purchaser. Your Mclntosh Authorized Service Agency can expedite repairs when
you provide the Service Contract with the
instrument for repair.
Contents
INTRODUCTION 3
INSTALLATION 4, 5
HOW TO CONNECT 6, 7
CONNECTING DIAGRAM 8
FRONT PANEL CONTROLS 9, 10
PERFORMANCE LIMITS 11
PERFORMANCE CHARTS 12
TECHNICAL DESCRIPTION 13, 14
BLOCK DIAGRAM 15
Take Advantage of 3 Years of
Contract Service. . . Fill in the Application NOW.
Your MR 7083 AM/FM Digital Tuner will give you
many years of satisfactory performance. If you have
any questions, please contact,
CUSTOMER SERVICE
Mclntosh Laboratory Inc. 2 Chambers Street
Binghamton, New York 13903-9990 Phone: 607-723-3512
MclNTOSH THREE YEAR SERVICE CONTRACT
An
application
The terms of the contract are:
1. If the instrument covered by this contract becomes defective, Mclntosh will provide all parts, materials, and labor needed to return the measured performance of the instrument to the
original performance limits free of any charge. The service contract does not cover any shipping costs to and from the authorized service agency or the factory.
2. Any Mclntosh authorized service agency will repair all Mclntosh instruments at normal service rates. To receive the free service under the terms
of the service contract, the service contract certificate must accompany the instrument when taken to the service agency.
3. Always have service done by a Mclntosh
authorized service agency. If the instrument is
for A
THREE
YEAR SERVICE
CONTRACT
4. The service contract is issued to you as the
5. Units in operation outside the United States and
is
included
modified or damaged as a result of unauthorized repair the service contract will be cancelled.
Damage by improper use or mishandling is not covered by the service contract.
original purchaser. To protect you from misrepresentation this contract cannot be
transferred to a second owner.
Canada are not covered by the Mclntosh Factory
Service Contract, irrespective of the place of
purchase. Nor are units acquired outside the USA and Canada, the purchasers of which should consult with their dealer to ascertain what, if any,
service contract or warranty may be available
locally.
with
this manual.
Copyright 1991 © by Mclntosh Laboratory Inc.
2
The Mclntosh MR 7083 is a high quality AM/FM Tuner whose design has been governed by insistence on high performance with long life, great flexibility and sensitivity.
You will derive the greatest enjoyment and most satisfaction from your MR 7083 when you understand its operations and functions. Your time invested now
will return added value to you because you will get the best results from your MR 7083.
Mclntosh has earned world renown for its techno­logical contributions for improved sound. When you bought Mclntosh, you bought not only high techno­logy, you bought technological integrity proven by
time. The Mclntosh MR 7083 Tuner is continuing evidence of Mclntosh technological superiority and
integrity.
Music reproducing instruments that carry the
Mclntosh name have always been designed for technological leadership and to maintain the Mclntosh reputation for durability, long life, and best sound. Mclntosh has had to earn the foremost
reputation for quality performance. Mclntosh has provided user-oriented facilities and appearance, and
Mclntosh design provides for ease of maintenance or
repair. These fundamental elements are incorporated in the Mclntosh MR 7083 AM/FM Tuner, the easiest
to operate yet with extensive useful features.
Your Mclntosh MR 7083, above all others, will
deliver the best sound and the greatest ease of use with a high degree of flexibility.
Some of the features that set the MR 7083 apart
from the ordinary are:
The advanced AM/FM tuner design of the MR 7083 displays the station frequencies digitally. Stations are selected easily in any one of these ways: A. use the
manual tuning knob, B. use the SCAN up or down touchbuttons, C. use the preset station touchbuttons or, D. use the SEARCH which will preview the preset stations for 5 seconds each.
The sound enhancing SPATIAL audio processor provides in quality and dimension. On noisy, weak FM sta-
tions or AM stations, SPATIAL provides reduced
noise and retains a broad stereo-like sound.
High quality tape recordings of FM broadcasts can be made without the interference that stereo trans­missions can cause. Carefully designed suppression
circuits eliminate the potential for stereo carrier
noise when making "off the air" tape recordings.
A unique Phase Locked Loop Multiplex decoder
an
aural
picture that
is
more "stereo
like"
delivers noise, and better separation.
will suit your particular installation. A low-impedance
loopstick will, in most local areas, provide AM
signals while rejecting noise and interference. In
noisy AM locations, an external noise reducing, noise canceling, shielded loop will provide ideal input signal. In a remote location, a conventional 'long wire' antenna can be used.
Mclntosh IR Remote Control system.
reinforced by your day-to-day use of this superb
instrument. Good listening.
STEREO
The most useful and flexible AM antenna system
The MR 7083 can be remote controlled from a All in all, your selection of the MR 7083 will be
FM
with
lower distortion, lower
INTRODUCTION 3
The trouble-free life of an electronic instrument is
greatly extended by providing sufficient ventilation to
prevent the build-up of high internal temperatures that cause deterioration. Allow enough clearance so that cool air can enter at the bottom of the cabinet and be vented from the top. With adequate ventilation the instrument can be mounted in any
position. The recommended minimum space for installation is 15 inches (38.1 cm) deep, 17 inches
(43.2 cm) wide, and 6 inches (15.2 cm) high.
The MR 7083 may be installed in a Mclntosh cabinet or custom installed in furniture of your choice. Always provide adequate ventilation. Never place it above heat generating components such as high powered amplifiers. Provide 1½ inches (3 cm) of space above the preamplifier so as not to interfere with a cooling air flow.
CUSTOM INSTALLATION
The PANLOC system of installing equipment conveniently and securely is a product of Mclntosh research. The PANLOC buttons on the front panel will lock the unit firmly in place when they are turned approximately one quarter turn clockwise. A counterclockwise turn of the PANLOC buttons
unlocks the chassis from its mounting.
To install the instrument in a Mclntosh cabinet, follow the instructions that are enclosed with the cabinet. For any other type of installation, follow these instructions:
1. Unpack from Carton Open the carton and remove the PANLOC brackets,
hardware package, and mounting template. Remove
the instrument from its plastic bag and place it
upside down on the shipping pallet. Unscrew the
four plastic feet from the bottom of the chassis.
2. Mark the Cabinet Panel Tape the mounting template in position on the cabinet panel where the instrument is to be
installed. The broken lines that represent the outline of the rectangular cutout also represent the outside dimensions of the chassis. Make sure these lines clear shelves, partitions, or any equipment. With the
template in place, first mark the six A and B holes
and the four small holes that locate the corners of
the cutout. Then, join the four corner markings with
pencil lines, using the edge of the template as a straightedge.
3. Drill Holes Use a drill with a 3/16 inch (5 mm) bit held perpendicular to the panel and drill the six A and B holes. Then, using a drill bit slightly larger than the
tip of your saw blade, drill one hole at each of two diagonally opposite corners. The holes should barely touch the inside edge of the penciled outline. Before taking the next step, make sure that the six A and B
holes have been drilled.
MOUNTING TEMPLATE
4 INSTALLATION
Loading...
+ 14 hidden pages