Liquid Controls E1615, E1616, E1617, E1618 User Manual

5 (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LectroCount® XL LED Remote Display

 

Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E1615/E1616/E1617/E1618

 

& Parts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid Controls Group An IDEX Fluid & Metering Business

Operation: EM300-55

 

 

Table of Contents

Introduction

 

Safety Procedures....................................................

3

General Information..................................................

4

Specifications............................................................

5

Dimensions...............................................................

5

Installation

 

Installation Overview.................................................

6

Installation Guidelines...............................................

6

Mounting...................................................................

7

Wiring - Model E1615...............................................

8

Wiring - Model E1616...............................................

9

Wiring - Model E1617..............................................

10

Wiring - Model E1618..............................................

11

Wiring - Automatic Shut-off......................................

13

Dual Display Kit........................................................

14

Rate of Flow Switch Kit............................................

15

Reset Switch Kit.......................................................

16

Decimal Place Jumper Settings...............................

17

Torque Specifications...............................................

18

Bill of Materials

 

Exploded View.........................................................

19

Bill of Materials.........................................................

19

NOTICE

This manual provides warnings and procedures that are intended to inform the owner and/or operator of the hazards present when using the Liquid Controls Meter on LPGas and other products. The reading of these warnings and the avoidance of such hazards is strictly in the hands of the owner-operators of the equipment. Neglect of that responsibility is not within the control of the manufacturer of the meter.

Publication Updates and Translations

The most current English versions of all Liquid Controls publications are available on our web site, www.lcmeter.com. It is the responsibility of the local distributor to provide the most current version of LC manuals, instructions, and specification sheets in the required language of the country, or the language of the end user to which the products are shipping. If there are questions about the language of any LC manuals, instructions, or specification sheets, please contact your local distributor.

2

Safety Procedures

Be Prepared

! WARNING

• Before using this product, read and understand the instructions.

• All work must be performed by qualified personnel trained in the proper application, installation, and maintenance of equipment and/or systems in accordance with all applicable codes and ordinances.

• When handling electronic components and boards, always use proper Electrostatic Discharge (ESD) equipment and follow the proper procedures

• Make sure that all necessary safety precautions have been taken.

• Provide for proper ventilation, temperature control, fire prevention, evacuation, and fire management.

• Provide easy access to the appropriate fire extinguishers for your product.

• Consult with your local fire department, state, and local codes to ensure adequate preparation.

• Read this manual as well as all the literature provided in your owner’s packet.

• Save these instructions for future reference.

• Failure to follow the instructions set forth in this publication could result in property damage, personal injury, or death from fire and/or explosion, or other hazards that may be associated with this type of equipment.

Observe National and

 

Local Codes

! WARNING

 

North America - Installations must be in full accordance with the National Electrical Code (US) or the Canadian Electrical Code respectively to maintain the hazardous location ratings on the product.

WARNING: Explosion Hazard -

Substitution of components may impair suitability for hazardous area applications.

WARNING: Explosion Hazard -

When in hazardous locations, turn power OFF before replacing or wiring modules.

WARNING: Explosion Hazard -

Do NOT disconnect equipment unless power has been switched OFF or the area is known to be Non-Hazardous.

Safely Evacuate

 

Piping System

! WARNING

 

Before disassembly of any meter or accessory component:

All internal pressures must be relieved and all liquid drained from the system in accordance with all applicable procedures.

Pressure must be 0 (zero) psi.

Close all liquid and vapor lines between the meter and liquid source.

Failure to follow this warning could result in property damage, personal injury, or death from fire and/or explosion, or other hazards that may be associated with this type of equipment.

3

Overview

General Information

This manual provides instructions for the installation, operation, and maintenance of the LectroCount XL LED Remote

Display. LectroCount XL LED Remote Displays display the volume of metered product in a six-digit configuration of high-intensity LED lights. The 2¼" high digits are viewable at up to 250 feet from the display.

Features

6-digit, high-intensity LED display with 2¼" high display characters

30', 4-wire, shielded cable

Weatherproof NEMA 4X enclosure

Viewable from up to 250 feet

Model Numbers & Device Compatibility

The four models of the LectroCount XL LED Remote Display are compatible with all current and legacy LectroCount registers, solid state quadrature pulsers, solid state single channel pulsers, and the LCMag™ HML210 converter.

LectroCount XL LED Remote Display Compatibility

E1615 LectroCount LCR® 600 and LectroCount LCR-II

E1616 LectroCount LCR, LectroCount3

E1616 Quadrature pulsers (solid state and calibrated)

E1616 LCMag HML210 and single channel pulsers (solid state and calibrated)

Prior to installation, make sure that the model number of the LectroCount XL LED Remote Display is compatible with the intended device. If the display model is not compatible, the display will not work and damage could occur when power is applied.

To ensure that the LectroCount XL LED Remote Display

 

 

 

 

 

 

 

 

 

 

 

 

with the intended, check the model number printed on

 

Remote Display Serial Number Tag

the display’s serial number tag. The serial number tag

 

 

 

 

 

 

 

can be found on the top of display.

 

 

 

 

 

 

Models E1615, E1616, E1617, E1618 of the LectroCount XL LED Remote Display render LectroCount LCD Remote Display models E1610, E1611, E1612, and E1613 obsolete.

Remote Display Label

Each shipment of the LectroCount XL LED Remote Display includes a set of four (4) additional unit of display labels. At the factory, all displays are assembled with the “Gallons” label. To change the “Gallons” label designation, simply remove the desired unit of display label from the backing and place it over the “Gallons” label.

Check Each Shipment

Before installation, check your shipment against the packing list and ensure that no parts are missing. The packing list is include in the same red information packet as this manual.

4

Liquid Controls E1615, E1616, E1617, E1618 User Manual

 

Specifications & Dimensions

Specifications

 

 

Temperature Range

Input Signal Levels

• -40 to 158 ºF (-40 to 70 ºC)

• High ≥ 2.50 VDC

Environmental Rating

• Lo ≤ 2.0 VDC

 

 

• NEMA 4X

Maximum Frequency Input

 

N/A

LectroCount LCR 600

Input Voltage

N/A

LectroCount LCR-II

• 9 to 28 VDC, 500 mA maximum

5 kHz LectroCount LCR

 

5 kHz LectroCount LC3

Dimensions

Front

18.125" 17.25"

16"

1.5"

3"

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.875" hole for ½" NPT cable gland or conduit fitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.125"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.25"

 

 

8.625"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Installation Overview & Guidelines

Installation Overview

The LectroCount XL LED Remote Display is shipped with a 30 foot, 4-wire, shielded cable threaded through a cord grip at the bottom of the display housing and a selection of unit of display labels twist-tied to the display.

Installation overview for the LectroCount XL LED Remote Display:

1.Check contents of the shipment and ensure that the correct model is included. page 4

2.Determine which accessories and settings are required and incorporate them into installation. pages 13-17

3.Mount the LectroCount XL LED Remote Display. page 7

4.Wire the LectroCount XL LED Remote Display. pages 8-12

Installation Guidelines

Read this manual prior to start of installation

If you have any questions, consult with your full service distributor or call the Service Department at Liquid Controls.

Avoid excessive vibration or shock

Ensure that the display does not sustain any excessive vibration or shock. The display should always be securely mounted to a platform or supportive member.

Match LectroCount XL LED Remote Display with the proper Device

The four models of the LectroCount XL LED Remote Display are designed for use with the devices specified No attempt should be made to connect the display to an input other than the specified device. Model numbers and compatibility are specified on the display’s serial number tag. page 4 Model Number and Device Compatibility

Use Proper Cabling and Wires

The LectroCount XL LED Remote Display is supplied with a 30 foot 4-wire shielded cable with 22 gauge wire. The shielded cable should be adequate for most installations. If alternate cabling is required, Liquid Controls recommends a 4-wire shielded cable with 22 gauge wire or larger and a maximum cable length of 30 feet.

Secure Cable and Tighten Cover Upon Reassembly

LectroCount XL LED Remote Displays are assembled and shipped ready for final cable termination. If the display’s preinstalled shielded cable is removed during installation, be sure to secure the cable and tighten the cover screws in the correct torque pattern so the vapor seal is maintained. page18TorqueSpecifications

! WARNING

The LectroCount XL LED Remote Display and accessories (whether supplied by Liquid Controls or other) must be installed and operated in accordance with all applicable federal, state, and local construction, electrical, environmental and safety codes. Failure to do so could result in serious injury or death.