INTRODUCTION:
time and outdoor temperature reading. With only two easy to use keys, this
innovative product is ideal for use in the home or office.
wireless transmission technology, exclusively designed and developed by LA CROSSE TECHNOLOGY. “IT +” offers you an immediate update of all your outdoor data measured from the transmitters: follow your climatic variations in real-time!
23
hole
THE TEMPERATURE STATION
LCD display
FEATURES: The Temperature Station
DCF-77 Radio Controlled time with manual settings
Time display (hour, minutes, seconds)
Time reception ON/OFF
12/24 hour time format
Calendar display (month, date, weekday)
Time zone option ±12 hours
Temperature display in Celsius (°C) or Fahrenheit (°F) selectable
Indoor and outdoor temperature display with MIN/MAX records
All MIN/MAX recordings can be reset
Wireless transmission at 868 MHz
Signal reception intervals at 4-second
MIN/MAX/+ key
24
Hanging
Battery compartment
SET key
Stand
Low battery indicator
Table standing or wall mountable
THE OUTDOOR TEMPERATURE TRANSMITTER
SETTING UP:
Note: This temperature station receives only one outdoor transmitter.
1. First, insert the batteries into the Temperature transmitter. (see “Install and replace batteries in the Temperature transmitter“).
2. Immediately after and within 30 seconds, insert the batteries into Temperature station (see “Install and replace batteries in the Temperature station”). Once the batteries are in place, all segments of the LCD will light up briefly. Following the time as 0:00 will be displayed and indoor temperature. If these are not displayed after 60 seconds, remove the batteries and wait for at least 10 seconds before reinserting them.
3. After inserting the batteries, the Temperature station will start receiving data from the transmitter. The outdoor temperature and the signal reception icon should then be displayed on the Temperature station. If this does not happen
Remote transmission of outdoor temperature to temperature station by 868MHz
Weather-resistant casing
Wall mounting case
Mount in a sheltered place. Avoid direct rain and
sunshine
25
after 3 minutes, the batteries will need to be removed from both units and reset from step 1.
4. In order to ensure sufficient 868 MHz transmission however, this should under good conditions be a distance no more than 100 meters between the final position of the Temperature station and the transmitter (see notes on “Mounting” and “868 MHz Reception”).
5. Once the remote temperature has been received and displayed on the Temperature station, the DCF time (radio controlled time) code reception is automatically started. This takes typically between 3-5 minutes in good conditions. If after 10 minutes, the DCF time has not been received, press the SET key to manually enter a time initially.
Note:
Daily DCF reception is done at two hours interval until a reception is successful for the day. If the reception is still not successful, then the next try takes place at 00:00 the next day.
If reception is successful, the received time will override the manually set time. The date is also updated with the received time. (Please refer also to notes on “DCF-77
Radio Controlled Time” and “Manual Time Setting”)
INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION
The Temperature station uses 2 x AAA, IEC
LR3, 1.5V batteries. To install and replace the
batteries, please follow the steps below:
1. Remove the cover at the back of the temperature station.
26
2. Insert batteries observing the correct polarity (see marking).
3. Replace compartment cover.
INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE TRANSMITTER
Note:
In the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. This is because a security code is assigned by the transmitter at start-up and this code must be received and stored by the Temperature station in the first 3 minutes of power being supplied to it.
BATTERY CHANGE:
It is recommended to replace the batteries in all units regularly to ensure optimum accuracy of these units (Battery life see Specifications below).
The Temperature Transmitter uses 2 x AA, IEC LR6, 1.5V battery. To install and replace the batteries, please follow the steps below:
1. Remove the battery compartment cover at the back of the transmitter.
2. Insert the batteries, observing the correct polarity (see marking).
3. Replace the battery compartment cover on the unit.
Please participate in the preservation of the environment. Return used batteries to an authorized depot.
27
FUNCTION KEYS: Temperature Station:
There are two easy-to-use function keys in the Temperature Station
MIN/MAX/+ key
SET key
Press and hold for about 3 seconds to enter the Manual setting modes:
manual time, year, date, month, weekday, 12/24 hour time format, time zone, time reception ON/OFF, and temperature settings.
Press and hold to reset the indoor and outdoor MIN/MAX temperature records
MIN/MAX/+ key
To make adjustments for various settings in manual setting modes
To toggle between the MIN/MAX readings of indoor/ outdoor temperature
SET key